Evaluation of Adhesive Performance of Surface Finishing Material with Primer Based on Silane (실란계 프라이머를 활용한 바닥 마감재 부착성능 평가)

  • Jeong, Gwon-Young;Youn, Da Ae;Jang, Seok-Joon;Kil, Bae-Su;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.39-46
    • /
    • 2017
  • The experimental research was conducted to evaluate the adhesive performance of surface finishing material with primer based on silane(primer). For this purpose, concrete specimens with compressive strength of 18, 30, 50 MPa were made and cured in water condition ($20{\pm}2^{\circ}C$) for 28 days. A primer was applied on the age of 28 days and evaluated according to based on the curing age of the surface finishing material. Moreover, the mortar specimen also made and tested as per KS F 4937 for compared with concrete-based test results. Test results indicated that the adhesive strength of specimens with primer exhibit similar than that of specimens without primer. Also, the adhesive performance improved with increasing in curing age and compressive strength. The correlation between compressive and adhesive strength of mortar and concrete specimens showed similar trend. It was noted that there is no significant effects of primer on adhesive performance of surface finishing material, thus use of primer has superior potential for solving durability problem of concrete slab surface.

A Study on Improving Concrete Techniques to Enhance the Performance of Concrete Floor (콘크리트 바닥 마감재의 성능 향상을 위한 시공법 개선 연구)

  • Jeong, Hojeong;Yu, Chaeyeon;Kim, Jaeyoung;Son, Seongwon;Ihm, Jongtae;Kim, Sungjin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.5
    • /
    • pp.529-540
    • /
    • 2024
  • This research aimed to refine the concrete floor finishing for enhancing its performance compared to the traditional way. The new method involved the removing the deteriorated mortar layer and reinforcing the surface to augment the durability and bond strength of the floor surface. This study performed the experience to evaluate the bond strength, drop depth, rebound hammer hardness, and the surface hardness of the surface by adopting traditional and refined method. The results showed the proposed method enhanced the performance on all the metrics. Based on the experiment, the bond strength increased about 2.79 times before installing the finishing material, and the strength also improved about 1.67 times and 1.44 times at the painted finishing and non-painted finishing, respectively. In addition, the drop depth decreased about 4.42 times when adopting the proposed method, which shows the enhanced resistance to declamination compared with applying the traditional way. Lastly, the surface hardness measured by scratch thickness significantly improved about 505% in this experiment. The finding of this study indicates that the proposed method can substantially enhance in bond strendth and durability of floor finishing, reduce the defects of the concrete-based floor, and extend the life of the products.

The Application of Color Asphalt Pavement on Parking Lot (칼라아스팔트콘크리트의 주차장 마감 적용 연구)

  • Jo, Shin-Haeng;Ryu, Deug-Hyun;Jeun, Jun-Young;Jun, Soon-Je;Lee, Seung-Woo
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.121-124
    • /
    • 2007
  • Strengths and weakness of preexistence materials were researched for applying color asphalt to pave on parking lot, then it was conducted mix-design so that to use on parking lot. If color asphalt is used on parking lot it makes skid resistance increase and noise reduction.

  • PDF

An Experimental Study on Material Property of Parking Zone Flooring Occupancy Surface Finishing Used to Environment-friendly.High-liquidity Ceramic Resin Mortar (친환경.고유동 세라믹 수지 모르타르를 이용한 주차장 바닥용 표면 마감의 재료적 특성에 관한 실험적 연구)

  • Lee, Sun-Gyu;Moon, You-Seok;Lee, Hyung-Jun;Lee, Wan-Hwi;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.829-832
    • /
    • 2008
  • Since the early 1980s, the building is dramatically higher increases. Therefore, the shortage of parking spaces as a social problem has been pointed out. The parking lot utilization of underground space is increasing by like this problem solving countermeasure. However, Most of the organic material is used for construction in the parking lot on the floor. The existing parking zone flooring occupancy surface finishing is harmful gases and environmental hormones cause of the worker. The study on the safety of the worker consider using environment-friendly?high-liquidity ceramic resin mortar materials to evaluate the characteristics and physical properties.

  • PDF

Effect on the Physical Performance of Functionalized Silane Coupling Agent on Epoxy-Based Concrete Surface Finishing Material for Parking Floor (기능성 실란 커플링제가 에폭시계 콘크리트 주차장 바닥용 마감재의 물리적 성능에 미치는 영향)

  • Chae, Woo-Byung;Seong, Dong-Yun;Seo, Sang-Kyo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.279-282
    • /
    • 2012
  • This study attempted to the effect on the physical performance of silane coupling agent on solventless epoxy-based concrete surface finishing material for parking floor. Tests were carried out in accordance with KS F 4041 and KS F 4937. The results of compressive strength, flexural compressive are 95.6N/㎟, 25.4N/㎟ and after wheel moving load testing, average abrasive depth is 0.96mm, these results satisfied the quality standard of KS F 4041, KS F 4937. As conclusion, this study confirmed that the silane coupling agent greatly effected on the physical performance of solventless epoxy resin.

  • PDF

Thermal Bridge and Heat Transfer Analysis for Each Part in Residential Building According to Construction of Wood-based Finishing Material (목질 마감재 구성에 따른 주거용 건축물 부위별 열교 및 전열성능 분석)

  • Seo, Jungki;Jeong, Su-Gwang;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.343-359
    • /
    • 2017
  • Many researches and policies have been carried out for saving energy in buildings. However, there are a few studies of thermal characteristics of wood-based materials that have been widely used as structural materials and finishing materials in buildings. In this study, thermal bridging areas were found to investigate thermal performance of residential building using non wood-based materials and wood-based materials. And heat transfer analysis of 16 case studies according to composition of structural materials and finishing materials was conducted. Also in this experiment, Physibel Trisco was used as the heat transfer analysis simulation tool, which conforms to the calculation method of ISO 10211. Analytical modeling was also carried out according to the ISO 10211, and the boundary temperature conditions were set at room temperature $20^{\circ}C$ and outdoor temperature $-11.3^{\circ}C$ (Seoul standard) according to the energy saving design standard in South Korea. Applied structures are classified according to the cases of concrete structure with non wood-based finishing materials, concrete structure with wood-based finishing materials and wood structure. Analyzed building elements were divided into a wall, a roof, an interlayer floor and a bottom floor. As a result, it can be confirmed that the thermal bridge of the concrete structure and wood structure were caused by the geometrical and material causes. In addition, the structural thermal bridge was caused in the discontinuity of the insulation in the concrete structure. Also it was confirmed that the linear heat transfer coefficient of the wall decreases when the wood-based materials are applied to the concrete structure.

An experimental study on the evaluation of abrasion resistance for concrete surface coating materials by cruising vehicle (차량 주행에 따른 콘크리트용 바닥 마감재의 마모저항성 평가방법)

  • Choi, Eun-Su;Kim, Young-Kun;Seo, Sang-Kyo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.849-852
    • /
    • 2008
  • In the wheel tracking test to evaluate abrasion resistance for concrete surface coating materials applied parking lot, weight of the wheel, test temperature, scattered sand amount, wheel speed, etc. various test condition is used for reliable evaluating the abrasion resistance performance of surface coating materials and the results depends on the test condition. In this paper, we carried experimental study as following on abrasion resistance with 2kinds of different environmental conditions. - Commons : real car tire with 300kg of load, 5km/h of speed, 80,000 cycle. - Control A : no other deterioration condition - Control B : scattering 1.0g of sand per every 30rounds from 1m height.

  • PDF

Vibration Analysis for the Living Room Slab of Apartment (아파트 거실 바닥판에 대한 진동해석)

  • Kim, Yong-Tae;Park, Kang-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.3 s.21
    • /
    • pp.93-101
    • /
    • 2006
  • Recently the floor vibration of apartment is often beginning to make its appearance of the environmental dispute, the standard floor system of housing are suggested for the settlement of this issue by government. For the slab vibration analysis on the laminated floor system of apartment, it is required the effectively analytical method of the floor system considering laminated theory. In this paper, more effective modeling methods of laminated floor slab are proposed for the method of accurate rigidity evaluation. By using the advanced modeling method, the more accurate vibration response can be obtained and can accurately evaluate the rigidity of living room floor system of apartment with different laminated materials.

  • PDF

Properties of Concrete for Industrial Floor using Mineral Admixtures (혼화재를 사용한 산업용 바닥 콘크리트의 물성 검토)

  • Kim, Yong-Ro;Gong, Min-Ho;Park, Jong-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.1
    • /
    • pp.17-24
    • /
    • 2016
  • Recently, exposed concrete by machinery trowel is generally used in industrial floor such as warehouse. Also, concrete using only the cement has been mainly used except mineral admixture in order to secure surface abrasion resistance. However, in hot weather construction, it is causing a serious problem such as workability inhibition of trowel using only ordinary portland cement. Due to this, it was investigated the effect of application of fly-ash and ground granulated blast furnace slag on properties and abrasion resistance of concrete for industrial floor in this study. The result of this study, it was confirmed that fly-ash and ground granulated blast furnace slag can be used in concrete for industrial floor without affecting significantly the properties of concrete.

Evaluation of Cracking Strength of Floating Floor System (뜬바닥구조의 균열강도 평가)

  • Lee, Jung-Yoon;Lee, Bum-Sik;Jun, Myoung-Hoon;Kim, Jong-Mun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • This paper reports the test results of the floating floor system used to reduce the floor noise of apartment buildings. Recently, many soft resilient materials placing between the reinforced concrete slab and finishing mortar are used. The resilient material should not only reduce the floor impact sound vibration from the floor but also support the load on the floor. Thus, even if soft resilient materials satisfy the maximum limitation of light-weight impact sound and heavy-weight impact sound, these materials may not support the load on the floor. The experimental program involved conducting sixteen sound insulation floating floor specimens. Three main parameters were considered in the experimental investigation: resilient materials, loading location, and layers of floor. Experimental results indicated that the stiffness of resilient material significantly influenced on the structural behavior of floating floor system. In addition, the deflection of the floating concrete floor loaded at the side or coner of the specimen was greater than that of the floor loaded at the center of the specimen. However, the aerated concrete did not effect on the cracking strength of floating floor system.