• Title/Summary/Keyword: 콘크리트 구조물 보수

Search Result 366, Processing Time 0.026 seconds

Fundamental Properties of MgO Base Ceramic Mortar for Concrete Repair Material (MgO계 세라믹 모르타르를 활용한 콘크리트 보수재료의 기초물성평가)

  • Park, Joon-Woo;Ann, Ki-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.4
    • /
    • pp.407-413
    • /
    • 2017
  • The fundamental property of magnesia phosphate cement (MPC) for concrete repair material was investigated in this research. For mechanical properties, setting time, compressive strength and tensile/flexural bond strength were measured, and hydration products were detected by X-ray diffraction. The specimens were manufactured with dead burnt magnesia and potassium dihydrogen phosphate was admixed to activate the hydration of magnesia and a borax was used as a retarder. To observe the pore structure and ionic permeability of MPC mortar, mercury intrusion porosimetry was performed together with rapid chloride penetration test (RCPT). As a result, time to set of Fresh MPC mortar was in range of 16 to 21 min depend on the M/P ratio. Borax helped delaying setting time of MPC to 68 min. The compressive strength of MPC with M/P of 4 was sharply developed to 30 MPa within 12 hours. The compressive strength of MPC mortar was in range of 11.0 to 30.0 MPa depend on the M/P ratio at 12 hours of curing. Both tensile and flexural bond strength of MPC to old substrate (i.e. MPC; New substrate to OPC; Old substrate) were even higher than ordinary Portland cement mortar (i.e. [OPC; New substrate] to [OPC; Old substrate]) does, accounting 19 and 17 MPa, respectively. The total pore volume of MPC mortar was lower than that of OPC mortar. MPC mortar had the entrained air void rather than capillary pore. The RCPT showed that total charge passed of OPC mortar had more than that of MPC mortar, which can be explained by the pore volume and pore distribution.

An Experimental Study on Time-Dependant Behavior of RC Beams Strengthened with FRP (FRP가 외부부착된 철근 콘크리트보의 시간의존거동에 관한 실험적 연구)

  • Kim, Sung-Hu;Kim, Jin-Yul;Kim, Kwang-Soo;Han, Kyoung-Bong;Park, Sun-Kyu;Song, Seul-Ki
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.41-44
    • /
    • 2008
  • Fiber Reinforced Polymers (FRPs) have recently been highly used for repairing and strengthening civil structures due to their superior material properties. By using FRPs, external bond method is the most used method in the construction industry. Although many researches on reinforced concrete externally strengthened with FRPs have been conducted, time-dependant behaviors of the beams have not been investigated yet. This paper documents a series of beam experiments that were carried out to evaluate time-dependant behavior. Three RC beams were built and the parameters considered in this experiment were types of FRPs. Through these experiments, it was proved that the beam strengthened with CFRP was more effective than that with GFRP in terms of time-dependant behavior.

  • PDF

Seismic Performance of RC Frame System Retrofitted with TS Seismic Strengthening Method(Part 2:Analytical Study) (TS 제진공법으로 내진보강된 철근콘크리트 골조의 내진성능(Part 2:해석적 연구))

  • Jung, Myung-Cheol;Song, Jeong-Weon;Song, Jin-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.148-153
    • /
    • 2018
  • In this study, the nonlinear time history analysis of seismic retrofitted structures with TS damper for seven ground motion records was conducted for the purpose of verifying the seismic strengthening effect of TS seismic retrofitting method. Through comparison of the interstory drift ratio and the energy dissipation amount of the non - reinforced structure obtained and those of retrofitted structures with TS damper from the nonlinear time history analysis, the interstory drift ratio was reduced by about 30% and the amount of energy dissipation through the structure was halved. As a result, it was confirmed that the damping performance of the TS seismic retrofitting method is excellent.

The Fundamental Properties of Foamed Concrete as the Eco-friendly Ground Repair System for Cast in Site Using the CSA (CSA를 사용한 친환경 지반보수용 현장 기포콘크리트의 기초 특성 검토)

  • Woo, Yang-Yi;Park, Keun-Bae;Ma, Young;Song, Hun-Young
    • Resources Recycling
    • /
    • v.29 no.1
    • /
    • pp.53-61
    • /
    • 2020
  • This study aimed to develop a foam concrete material for a ground repair system that has low strength and low fluidity by using an eco-friendly binder, which substitutes industrial by-products for more than 90% of cement. Basic properties were evaluated after substituting a small amount of calcium sulfo aluminate (CSA) for the binder to improve the sinking depth rate and volume change, commonly found when it had a large amount of industrial by-products. The substitution rates of CSA for the eco-friendly binder used for the foam concrete were 2.5, 5, and 10%. Fresh properties, hardened properties, pore structure, and hydrates were analyzed. Experimental results showed that using only 2.5% of CSA could improve the deep sinking depth which occurred when using an eco-friendly binder. As a result, the weight difference between the upper, middle, and lower parts of cast specimens was improved even after being hardened. The addition of CSA also contributed to the formation of small, uniformly sized closed pores and improved initial strength. However, when the proportion of CSA increased, the long-term strength decreased. However, it satisfied the target strength when 5% or less of CSA was used. The results of this study revealed that it was possible to manufacture foam concrete with low strength and high fluidity for repairing ground satisfying target qualities by adding 2.5% of CSA to the eco-friendly binder containing a large amount of industrial by-products.

Compressive Strength Correlation of Very-Early-Strength Dry-Mix Shotcrete on Test Method (측정방법에 따른 속경성 건식 숏크리트 압축강도의 상관관계)

  • Yun, Kyong-Ku;Choi, Sung-Yong;Kim, Jin-Woung;Kil, Yong-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3988-3997
    • /
    • 2010
  • Shotcrete was a mortar or concrete that is pneumatically projected at high velocity onto a subject. It has been applied for tunneling, underground big-spaces, slope stabilization. Shotcrete is increasing use in structure repair. The dry-mix shotcrete require a smaller equipment, easy maintenance, possible of very-earlystrength materials than wet-mix shotcrete, which make this process attractive and economic for structural repairs. It is common practice core compressive strength to the dry-mix shotcrete quality control. This test is very difficult estimating eraly-strength of Very-Early-Strength Dry-Mix Shotcrete. The purpose of this research was to analyze the correlation of test results among cube test, core test, pullout test and maturity. The correlationship analysis of test results among cube test, core test, pullout test and maturity showed more than 90%.

An Experimental Study on the Shear Failure Behavior of Post-installed Set Anchor for Concrete (콘크리트용 후설치 세트앵커의 전단파괴거동에 관한 실험적 연구)

  • Um, Chan-Hee;Yoo, Seung-Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.367-375
    • /
    • 2014
  • Recently the use of concrete post-installed set anchors has been increasing because this constructing method is flexible and easy to attach or fix structural members when we repair, reinforce, or remodel a concrete structures. Depending on the shear strength of steel, the strength of concrete, edge distance and anchor interval, etc, the anchor loaded in shearing exhibits various failure modes such as steel failure, concrete failure, concrete pryout. In this study, the objective is to investigate the effects of the variations like anchor embedment depth, anchor interval, edge distance and concrete strength on the shear failure behavior of post-installed concrete set anchor embedded in concrete. The results of embedment depth experiments show that concrete strength has much effection on the shallow embedment depth. Steel failure occur to all results of the anchor interval experiments, but concrete is failed when edge distance experiments that less than the embedment depth. Through the comparision of the same parameters experiments results show that as strong as concrete strength are the displacement results are small.

Influence of Cracks in Precast Concrete Deck on the Flexural Strength of Composite Half PC Slab (하프PC 슬래브에 발생한 균열이 합성 슬래브의 휨 내력에 미치는 영향에 관한 실험적 연구)

  • Seo, Tae-Seok;Lee, Moon-Sung;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.199-205
    • /
    • 2009
  • Recently, as the concern for the development of a construction method for an environmental protection and for tall building is increasing, the use of the half precast concrete(PC) slab that has the solution of environmental problems and the advantage such as reduction of construction period is being demanded. However, there is shortcoming that the crack can occur easily while constructing, and these cracks can have a bad influence upon the structural performance of PC composite slab. However, there is little studies on the influence of these cracks on the structural performance of composite PC slab. In this study, the specimen caused the crack before pouring topping concrete in the half PC slab and the PC composite slab without the cracks were produced to investigate the structural performance of PC composite slab with crack.

Crack Example and Crack Control Method of Very-Early Strength Latex-Modified Concrete (초속경 라텍스개질 콘크리트의 균열발생 사례 및 억제방안)

  • Choi, Pan-Gil;Yun, Kyong-Ku;Lee, Bong-Hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.173-180
    • /
    • 2009
  • Very-early strength latex-modified concrete(below ; VES-LMC) was developed for possible early-opening-to-traffic after overlay of bridge deck concrete. The purpose of this study is to analyze the cause of map, transverse and longitudinal cracking in VES-LMC and to provide a control method for minimizing occurrence of cracking. The proposed prevention method against map and transverse cracking was verified by field data. VES cement was modified as the unit cement content was reduced from 390kg/$m^3$ to 360kg/$m^3$. The maximum size of coarse aggregate was increased from 13mm to 19mm. The wire mesh and steel fiber were adopted in concrete mixture. From the results, the proposed prevention method against map and transverse cracking was verified since structural cracking was not occurred until 3 years after overlay.

Effect of Surface Preparation and Curing Condition on the Interfacial Bond Strength between Ultra High Performance Concrete and Normal Strength Concrete (표면처리 및 양생 조건이 초고성능 콘크리트-보통 콘크리트 계면 부착강도에 미치는 영향)

  • Kang, Sung-Hoon;Hong, Sung-Gul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.149-160
    • /
    • 2015
  • This study reports the interfacial bond strength between Ultra High Performance Concrete (UHPC) and Normal Strength Concrete (NSC). While previous studies have focused on the interfacial strength between NSC substrate and UHPC overlay, this study use precast UHPC for enhanced constructability and replacement of formwork. The factors affecting the interface strength are comprehensively reviewed. It can be classified into: interface shape, degree of hardening and moisture condition of UHPC before combining with NSC, and curing condition of composite materials. Conducted experiments verify the effects of each factor on the interface strength and, accordingly show different failure modes. In particular, a new failure mode of the failure of a part of UHPC was firstly found in the case of sample with rough interface between UHPC and NSC. The other factors of the degree of hardening and the moisture and curing conditions of UHPC were discussed. This research will provide a valuable foundation to utilize the UHPC as a composite material.

Fire Resistance Performance of High Strength Concrete Columns with Fireproof Gypsum Board (방화석고보드를 부착한 고강도 콘크리트 기둥의 내화성능)

  • Youm, Kwang-Soo;Jeon, Hyun-Gyu
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.2
    • /
    • pp.229-235
    • /
    • 2010
  • In this study, fire resistance performance of high strength concrete specimen with fireproof gypsum board was investigated for possible use in upgrading fire-resistant performance of the existing building and repair of fire damaged structures. Fire test of eight identical high strength concrete columns were carried out for 180 minutes in accordance with ISO-834. The temperature distributions in longitudinal reinforcement and concrete temperature at various depths were recorded. The fireproof performance of gypsum board and explosive spalling of concrete were observed. The specimens with 15 mm thick twoply fireproof gypsum board spalled after gypsum board crumbled regardless of fastening methods. However, when the thickness of fireproof gypsum board was more than 30 mm, it was possible to prevent the explosive spalling and control the rebar temperature. Although the effect of cover thickness could not be compared because the explosive spalling occurred, there seemed to be no difference in insulation efficiency.