Browse > Article
http://dx.doi.org/10.5762/KAIS.2010.11.10.3988

Compressive Strength Correlation of Very-Early-Strength Dry-Mix Shotcrete on Test Method  

Yun, Kyong-Ku (Department of Civil Engineering, Kangwon National University)
Choi, Sung-Yong (Department of Civil Engineering, Kangwon National University)
Kim, Jin-Woung (Korea Expressway Co.)
Kil, Yong-Su (SAMWOOIMC)
Publication Information
Journal of the Korea Academia-Industrial cooperation Society / v.11, no.10, 2010 , pp. 3988-3997 More about this Journal
Abstract
Shotcrete was a mortar or concrete that is pneumatically projected at high velocity onto a subject. It has been applied for tunneling, underground big-spaces, slope stabilization. Shotcrete is increasing use in structure repair. The dry-mix shotcrete require a smaller equipment, easy maintenance, possible of very-earlystrength materials than wet-mix shotcrete, which make this process attractive and economic for structural repairs. It is common practice core compressive strength to the dry-mix shotcrete quality control. This test is very difficult estimating eraly-strength of Very-Early-Strength Dry-Mix Shotcrete. The purpose of this research was to analyze the correlation of test results among cube test, core test, pullout test and maturity. The correlationship analysis of test results among cube test, core test, pullout test and maturity showed more than 90%.
Keywords
Dry-Mix Shotcrete; Strength Correlation; Very-Early-Strength; Pullout Test; Maturity;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 한국콘크리트학회, "최신콘크리트공학", 기문당, 2007.
2 American Society for Testing and Materials. 2005a. Standard Practice for Estimating Concrete Strength by the Maturity Method. ASTM C 1074. Philadelphia, PA.
3 ASTM C900-82, "Standard Test Method for Pullout Strength of Hardened Concrete", ASTM Committee on Standards, 1916 Race Street, Philadelphia, pa. 19103, USA
4 EFNARC, European specification for sprayed concrete, United Kingdom, 1996.
5 EFNARC, European specification for sprayed concrete, United Kingdom, 2002.
6 Iwaki, K., Hirama, A., Mitani, K., Kaise, S., Nakagawa, K., "A quality control method for shotcrete strength by pneumatic pin penetration test", NDT & E International 34, pp. 395-402, 2001.   DOI
7 Jolin, Marc., "Mechanisms of Placement and Stability of Dry Process Shotcrete" PH.D Thesis, University of British Columbia, 1999.
8 Morgan, D.R., "Shotcrete Repair of Infrastructure in North America", Beton-Instandsetzung 97, Igls, Austria, January, 17 pp, 1997.
9 Morgan, D.R., McAskill, N., Heere, R., "Determination of Early-Age Compressive Strength of Shotcrete", 3rd International Symposium on Sprayed Concrete, Gol, Norway, Semtember 26-29pp, 1999.
10 고영도, "초속경 건식 숏크리트의 현장적용성 평가", 강원대학교 석사학위 논문, 2008.
11 고훈범, 이진섭, "콘크리트의 강도 예측과 새로운 인발시험법의 제안", 대한건축학회 논문집 22권 8호(통권214호), pp. 93-100, 2006.   과학기술학회마을
12 장석부, 이성우, 홍의준, 문상조, "숏크리트의 현장강도 시험기술 개발에 관한 연구", 유신기술회보 제13호, pp. 99-109, 2007.