Browse > Article
http://dx.doi.org/10.4334/JKCI.2010.22.2.229

Fire Resistance Performance of High Strength Concrete Columns with Fireproof Gypsum Board  

Youm, Kwang-Soo (GS E&C Research Institute, GS E&C)
Jeon, Hyun-Gyu (GS E&C Research Institute, GS E&C)
Publication Information
Journal of the Korea Concrete Institute / v.22, no.2, 2010 , pp. 229-235 More about this Journal
Abstract
In this study, fire resistance performance of high strength concrete specimen with fireproof gypsum board was investigated for possible use in upgrading fire-resistant performance of the existing building and repair of fire damaged structures. Fire test of eight identical high strength concrete columns were carried out for 180 minutes in accordance with ISO-834. The temperature distributions in longitudinal reinforcement and concrete temperature at various depths were recorded. The fireproof performance of gypsum board and explosive spalling of concrete were observed. The specimens with 15 mm thick twoply fireproof gypsum board spalled after gypsum board crumbled regardless of fastening methods. However, when the thickness of fireproof gypsum board was more than 30 mm, it was possible to prevent the explosive spalling and control the rebar temperature. Although the effect of cover thickness could not be compared because the explosive spalling occurred, there seemed to be no difference in insulation efficiency.
Keywords
fire-resistant gypsum board; explosive spalling; fire resistance performance; fastening method; glass fiber tissue;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 원종필, 장창일, 이상우, 김흥열, 김완영, “하이브리드 섬유보강 고강도콘크리트 기둥부재의 내화성능,” 콘크리트학회 논문집, 20권, 6호, 2008, pp. 827-832.   과학기술학회마을   DOI   ScienceOn
2 송영찬, 이세현, 양완희, 김우재, 백병훈, “고강도 콘크리트의 폭렬방지를 위한 피복부착공법의 기초적 연구,” 대한건축학회 학술발표논문집, 26권, 1호, 2006, pp. 365-368.
3 www.lafage-gypsum.co.kr.
4 Concrete Center, Concrete and Fire, The Concrete Center, 2004, 4 pp.
5 국토해양부 고시, 고강도콘크리트 기둥·보의 내화성능 관리기준, 제2008-334호, 2008, pp. 1-8.
6 Nishida, A., Ymazaki, N., Inoue, H., Schneider, U., and Diederichs, U., “Study on the Properties of High-strength Concrete with Short Polypropylene Fibre for Spalling Resistance,” Proceedings of International Conference on Concrete under Severe Conditions. CONSEC'95, Vol. 2, Sapporo, Japan, 1995, pp. 1141-1150.
7 Atkinson, T., “Polypropylene Fibers Control Explosive Spalling in High-performance Concrete,” Concrete, Vol. 38, No. 10, 2004, pp. 69-70.
8 장기현, 김원기, 김호림, 이진우, 양성환, 한천구, “고강도 콘크리트의 내화특성에 미치는 방화석고보드의 두께 및 접착 보강 방식의 영향,” 대한건축학회 학술발표논문집, 28권, 1호, 2008, pp. 427-430.
9 염광수, 전현규, 김흥열, “섬유혼입공법을 적용한 고강도 콘크리트 기둥의 비재하 내화시험,” 콘크리트학회 논문집, 21권, 4호, 2009, pp. 467-473.   과학기술학회마을   DOI   ScienceOn