• Title/Summary/Keyword: 콘빔 CT

Search Result 40, Processing Time 0.034 seconds

A Study on the Availability of the On-Board Imager(OBI) and Cone-Beam CT(CBCT) in the Verification of Patient Set-up (온보드 영상장치(On-Board Imager) 및 콘빔CT(CBCT)를 이용한 환자 자세 검증의 유용성에 대한 연구)

  • Bak, Jino;Park, Sung-Ho;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.118-125
    • /
    • 2008
  • Purpose: On-line image guided radiation therapy(on-line IGRT) and(kV X-ray images or cone beam CT images) were obtained by an on-board imager(OBI) and cone beam CT(CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images(kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. Materials and Methods: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. Results: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within $0.06^{\circ}$ for rotation only, 1.8 mm for translation only, and 2.1 mm and $0.3^{\circ}$ for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within $0.03^{\circ}$ for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and $0.0^{\circ}$ for rotation, respectively, was possible. Conclusion: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.

Dose Comparison Using Deformed Image Registration Method on Breast Cancer Radiotherapy (유방암 방사선치료에서 변형영상정합기법을 이용한 선량비교)

  • Won, Young Jin;Kim, Jong Won;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.57-62
    • /
    • 2017
  • The purpose of this study is to reconstruct the treatment plan by applying CBCT and DIR to dose changes according to the change of the patient's motion and breast shape in the large breast cancer patients and to compare the doses using TWF, FIF and IMRT. CT and CBCT were performed with MIM6 to create DIRCT and each treatment plan was made. The patient underwent computed tomography simulation in both prone and supine position. The homogeneity index (HI), conformity index (CI), coverage index (CVI) to the left breast as planning target volume (PTV) were determined and the doses to the lung, heart, and right breast as organ at risk (OAR) were compared by using dose-volume histogram and the unique property of each organ. The value of HI of the PTV breast increased in all treatment planning methods using DIRCT, and CVI and CI were decreased in the treatment planning methods using DIRCT.

Three dimensional cone-beam CT study of upper airway change after mandibular setback surgery for skeletal Class III malocclusion patients (Cone-beam CT를 이용한 골격성 III급 부정교합자의 하악골 후퇴술 후 상기도 변화에 관한 연구)

  • Kim, Na-Ri;Kim, Yong-Il;Park, Soo-Byung;Hwang, Dae-Seok
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.145-155
    • /
    • 2010
  • Objective: Lateral cephalometric radiographs have been the main form of resource for assessing two dimensional anteroposterior airway changes. The purpose of this study was to evaluate the three dimensional volumetric change in the upper airway space in Class III malocclusion patients who underwent mandibular setback surgery. Methods: Three dimensional cone-beam computed tomographs (CBCT) and their three dimensional reconstruction images were analyzed. The samples consisted of 20 adult patients (12 males and 8 females) who were diagnosed as skeletal Class III and underwent mandibular setback surgery. CBCTs were taken at 3 stages - Baseline (1.8 weeks before surgery), T1 (2.3 months after surgery), and T2 (1 year after surgery). Pharyngeal airway was separated according to the reference planes and reconstructed into the nasopharynx, the oropharynx and the hypopharynx. Measurements at Baseline, T1, and T2 were compared between groups. Results: The result showed the volume of the pharyngeal airway decreased significantly 2.3 months after surgery (p < 0.001) and the diminished airway did not recover after 1 year post-surgery. The oropharynx was the most decreased area. Conclusions: These findings suggest that mandibular setback surgery causes both short-term and long-term decrease in the upper airway space.

Study of Dynamic Variation Aspect in Lung Volume due to Respiration in Stereotactic Body Radiotherapy Using Abdominal Compressor (복부압박장치를 이용한 정위적방사선치료 시 호흡에 따른 폐암 용적의 동적변이 양상에 대한 연구)

  • Park, Kwang Soon;Kim, Joo Ho;Park, Hyo Kook;Beak, Jong Geal;Lee, Sang Kyoo;Yoon, Jong Won;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.159-165
    • /
    • 2013
  • Purpose: Abdominal compressor is used to control breathing in stereotactic body radiotherapy for lung tumors frequently. We evaluated the dynamic variation aspect of internal tumor volume by breathing. Materials and Methods: We reviewed 20 lung cancer patients (7 upper lung patients, 4 middle lung patients, 9 lower lung patients) who received stereotactic body radiotherapy using abdominal compressor between April 2012 to April 2013. Coordinate shift values were obtained by using four-dimensional cone-beam CT (4D-CBCT) to investigate treatment set-up error and moving tumor position error. To investigate how much difference of each part, we compared 95% confidence interval, maximum values and minimum values of three-dimensional vector value and analyzed conformity degree through the Pearson square correlation coefficient. Results: 95% confidence interval of three-dimensional vector value of each part is 1.8~2.9 mm in upper lobe, 2.3~5.4 mm in middle lobe and 2.2~4.0 mm in lower lobe. Conformity degree was the result that respectively is LR direction 0.75, SI direction 0.68 and AP direction 0.63 in upper lobe, LR direction 0.82, SI direction 0.51 and AP direction 0.92 in middle lobe and LR direction 0.63, SI direction 0.50 and AP direction 0.34 in lower lobe. Conclusion: We showed difference by each site in lung tumor due to respiration by using abdominal compressor. Therefore, we must correct treatment set-up error as well as moving tumor position error by breathing. It is also considered to be useful that it is the use of 4D-CBCT when correcting the error due to various dynamic variation.

  • PDF

Correlation between menton deviation and dental compensation in facial asymmetry using cone-beam CT (Cone-beam CT를 이용한 안면비대칭자에서 이부편위에 따른 치성보상의 양상분석)

  • Park, Soo-Byung;Park, Jeong-Heuy;Jung, Yun-Hoa;Jo, Bong-Hye;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.39 no.5
    • /
    • pp.300-309
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the correlation between menton deviation and dental compensation in facial asymmetry. Methods: Tooth axis and distance of first molar and canine to the reference plane were investigated by cone-beam computerized tomography. The subjects consisted of 50 patients with asymmetric mandibles (male 21, female 29, mean age 24.3 years). Control groups were also assessed (male 11, female 9, mean age 25.6 years). Nine measurements (5 linear measurements and 4 angular measurements) were measured in order to evaluate the correlation between menton deviation and the linear and angular difference of first molar and canine in the deviated and none-deviated sides using the defined MPR images. The differences between deviated and non-deviated side, according to menton deviation, were statistically analyzed using stepwise multiple regression analysis. Results: From the result, Menton deviation was negatively correlated with mandibular first molar's angular measurement (${\Delta\angle}LM6$-Mn plane (dev.-ndev.)) and positively with maxillary fist molar's angular measurement (${\Delta\angle}UM6$-FH plane (dev.-ndev.)) (p < 0.01). Two angular measurements (${\Delta\angle}LM6$-Mn plane (dev.-ndev.), ${\Delta\angle}UM6$-FH plane (dev.-ndev.)) explained the variability in menton deviation with a significant $r^2$ value of 0.589. Conclusions: This study suggests that the tooth axis of upper and lower first molars leans towards the deviated side of Menton when there is mandibular asymmetry with Menton deviation.

The assessment of dentoalveolar compensation in facial asymmetry individuals: integration of cone beam CT and laser scanned dental cast images (Cone beam CT 영상과 석고모형 레이저 스캔 영상의 결합을 이용한 안면비대칭자의 치성보상 평가)

  • Song, Hyo-Kyung;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.40 no.6
    • /
    • pp.373-382
    • /
    • 2010
  • Objective: The purpose of this study was to assess the dentoalveolar compensation in facial asymmetry individuals using an integration of a CBCT image and a laser scanned dental cast image. Methods: The subjects consisted of 30 adults with asymmetric mandibles and 20 adults with symmetric mandibles. The CBCT and laser scanned dental cast images were integrated with a registration technique. Canine and first molar position and angulation were assessed from reference coordinates. The differences between deviated and non-deviated sides were analyzed with the paired t-test. The differences shown according to menton deviation were also statistically analyzed using Pearson correlation analysis. Results: The experimental group showed deviated and non-deviated side differences (dev.-ndev.) in the position and angle of the canine and first molars. Menton deviation showed positive correlation with the deviation side (dev.-ndev.) for the maxillary and mandibular 1st molar angles, negative correlation with the deviation side for the vertical position of the maxillary 1st molars, transverse position of the mandibular canine, transverse position and vertical position of the mesio-lingual cusp of the mandibular 1st molars. Conclusions: The upper and lower canine and first molars of facial asymmetry individuals were compensated, so the transverse position, vertical position, and angle showed differences between the deviated/non-deviated sides.

The relationship between condyle position, morphology and chin deviation in skeletal Class III patients with facial asymmetry using cone-beam CT (안면비대칭을 동반한 골격성 III급 부정교합자에서 하악 과두의, 위치 형태와 이부 편위의 관계: cone-beam CT를 이용한 연구)

  • Lee, Bo-Ram;Kang, Dae-Keun;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il;Lee, Kyung-Min
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.87-97
    • /
    • 2011
  • Objective: Facial asymmetry is usually evaluated from the difference in length and angulation of the maxilla and mandible. However, asymmetric position or shape of the condyle can also affect the expression of asymmetry. The purpose of this study was to evaluate the correlation between condylar asymmetry and chin point deviation in facial asymmetry. Methods: Cone-beam CT images of fifty adult skeletal Class III patients were studied. Thirty patients who had more than 4 mm menton deviation were categorized in the asymmetric group. Twenty patients with less than 4 mm menton deviation were assigned to the symmetric group. Anteroposterior and transverse condyle positions were evaluated from the cranial base. The greatest mediolateral diameter (GMD) of the condyle in the axial plane and angulation to the coronal plane were measured. The height and volume of the condyles were evaluated. Results: The symmetric group had no statistical difference between both condyles in position, angulation, GMD, height and volume. In the asymmetric group, the non-deviated side condyle was larger in GMD, height and volume than the deviated side. There was no statistical difference in condyle position and angulation. The GMD, height difference and condylar volume ratio (non-deviated/deviated) were positively correlated with chin deviation. From the linear regression analysis, condylar volume ratio was a significant factor affecting chin deviation. Conclusions: These findings suggests that the non-deviated side condyle is larger than the deviated side. In addition, condylar asymmetry can affect the expression of facial asymmetry.

Three dimensional analysis of the upper airway and facial morphology in children with Class II malocclusion using cone-beam computed tomography (Cone-beam CT를 이용한 제II급 부정교합 아동의 상기도 형태에 관한 3차원적 연구)

  • Hong, Ji-Suk;Kim, Dae-Sung;Oh, Kyung-Min;Kim, Yoon-Ji;Lee, Kyu-Hong;Park, Yang-Ho
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.134-144
    • /
    • 2010
  • Objective: The aim of this study was to evaluate the volumes and areas of the upper airways in children with Class II malocclusion, using three dimensional cone-beam computed tomography (CBCT) and to compare the volumetric and cross-sectional measurements and cephalometric variables to investigate possible relationships between the upper airway and facial morphology. Methods: CBCT scans were obtained from 37 subjects (17 boys and 20 girls; average age, 11.02 years). The upper airway volumes and areas were measured, and compared with cephalometric variables. Results: The area of the PNS-posterior plane ($S_{PP}$) was significantly smaller in the Class II malocclusion group (p < 0.05). Also, the volumetric and cross-sectional measurements were lower in Class II than in Class I malocclusion groups, although the differences were not significant between the two groups (p > 0.05). The Class II malocclusion group showed significantly smaller values of PFH, mandibular body length, pog to N perp and showed larger values of FMA, ANB, and facial convexity than the Class I malocclusion group. The volume of the upper airway in front of PNS point (WN) showed negative correlation with ANB (p < 0.05). Conclusions: The Class II malocclusion group had a narrower upper airway associated with a decreased posterior facial height and a divergent growth pattern than the Class I malocclusion group.

Development of Quality Assurance Program for the On-board Imager Isocenter Accuracy with Gantry Rotation (갠트리 회전에 의한 온-보드 영상장치 회전중심점의 정도관리 프로그램 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.212-223
    • /
    • 2006
  • Positional accuracy of the on-board imager (OBI) isocenter with gantry rotation was presented in this paper. Three different type of automatic evaluation methods of discrepancies between therapeutic and OBI isocenter using digital image processing techniques as well as a procedure stated in the customer acceptance procedure (CAP) were applied to check OBI isocenter migration trends. Two kinds of kV x-ray image set obtained at OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ},\;270^{\circ}$ and every $10^{\circ}$ and raw projection data for cone-beam CT reconstruction were used for each evaluation method. Efficiencies of the methods were also estimated. If a user needs to obtain an isocenter variation map with full gantry rotation, a method taking OBI image for every $10^{\circ}$ and fitting with 5th order polynomial was appropriate. However for a mere quality assurance (QA) purpose of OBI isocenter accuracy, it was adequate to use only four OBI Images taken at the OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ}\;and\;270^{\circ}$. Maximal discrepancy was 0.44 mm which was observed between the OBI source angle of $90^{\circ}\;and\;180^{\circ}$ OBI isocenter accuracy was maintained below 0.5 mm for a year. Proposed QA program may be helpful to Implement a reasonable routine QA of the OBI isocenter accuracy without great efforts.

  • PDF

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.