• Title/Summary/Keyword: 콘덴서

Search Result 383, Processing Time 0.024 seconds

On the Stability of the Push-Pull Current-Fed DC-DC Converter (전류형 DC-DC 콘버어터의 안정성에 관하여)

  • ;原田 #介
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.3
    • /
    • pp.54-59
    • /
    • 1985
  • From the foregoing papers, it has been clarified that the push-pull current-fed DC-DC converter is excellent in stability as compared with the other conventional DC-DC con-verters. The relation between the stability of the converter and the capacitance of smoothing condenser is analyzed, considering the ESR of smoothing condenser and the 1 st order phase lag of the feedback circuit. From the results, it is known that when the capacitance of smoothing condenser is reduced, the stability of the converter is also excellent as compared with the conventional buck type converter, whereas there are limitations for practical use, since the ripple of output voltage increases by increasing of output current.

  • PDF

Study on the Performance Verification Method and Failure Mechanism of Grading Capacitor of a Two-break Circuit-breaker (2점절 차단기 균압용 콘덴서 절연파괴 고장 메커니즘 및 성능검증 방법에 관한 연구)

  • Oh, SeungRyle;Han, Kisun;Kim, TaeKyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2019
  • Recently, the circuit-breaker rated voltage is getting higher as the transmission voltage increases. To increase the circuit-breaker rated voltage, a multi-break circuit-breaker which has two or more breakers in series is adopted. For multi-break circuit-breaker, a grading capacitor is used to mitigate the Transient Recovery Voltage(TRV) and control the voltage distribution across the individual interrupter units. However, all over the world, there are many failures such as mechanical damage, explosion due to insulation breakdown. Therefore, it is necessary to study the causes of failure and the new performance verification method. In this paper, we investigate the causes of dielectric breakdown of the grading capacitors in the KEPCO power system and propose the performance verification method.

Effects of Separator Carbonization on the Characteristics of Aluminium Polymer Condenser (알루미늄 고분자 콘덴서의 특성에 대한 절연지 탄화의 영향)

  • Kim, Jae Kun;Yu, Hyung Jin;Hong, Yoong He;Park, Mi Jin;Park, Seung Youl
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.539-546
    • /
    • 2006
  • A study on the polymerization of polyethylenedioxythiophene (PEDOT) and the carbonization process of a separator was carred out in order to apply conductive polymer PEDOT to the winding typed aluminum condenser as a solid electrolyte and a negative electrode. PEDOT was polymerized with ethylenedioxythiophene (EDOT) as a monomer and ferric-p-toluenesulfonate as an oxidizing agent. The separator of condenser element was carbonized to control its fibrous tissue for the purpose of making it easy to impregnate the PEDOT solution into the microporous etched pit of aluminum foil by preventing separator from concentrating the PEDOT solution on itself. The characteristics of condenser such as capacitance, dissipation factor, equivalent series resistance, and thermal resistance depended on a carbonization temperature and a carbonization time. It was found that a thickness and a density of the used separator were major parameters of carbonization process and the characteristics of condenser were affected by these parameters.

Analysis of a breakdown in 154 kV STATCON Bank condenser cell (154kV SC Bank 콘덴서 절연파괴 대책연구)

  • Ju H.J.;Khak J.S.;Woo J.W.;Kang Y.W.;shim E.B.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.537-540
    • /
    • 2004
  • 154 kV 변전소에 설치 운전 중인 SC Bank콘덴서 셀의 절연파괴 고장이 빈번하게 발생되어 전력계통의 운용 덴 변전소 운전에 지장을 주는 사례가 많이 발생하였다. 따라서 이의 고장원인 진단을 통하여 대책수립을 하고자 EMTP(Electro-Magnetic Transient Program)를 이용하여 50의 SC Bank의 정상상태시 과전압, 과전류에 의한 소손현상을 검토하고, 계통조건에 따른 공진점변화와 고조파에 따른 이상전압 및 콘덴서 셀 전압의 상승 현상을 검토 분석하고, 현장 실측을 통하여 고조파성분에 따른 과전압 및 과전류를 분석하여 대책을 제시한 사례 연구의 결과이다.

  • PDF

Numerical Analysis of Water Hammer in Condenser Cooling Water Systems (콘덴서 냉각수 계통내의 수격현상 에 관한 수치해석)

  • 장효환;정회범
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.638-646
    • /
    • 1985
  • Water hammering in nuclear or thermal power plant condenser cooling water systems in mathematically modeled and numerically analyzed based on the method of characteristics. Effects of variations of the discharge valve operating condition and the system geometry on the hydraulic transients are investigated for the cases when all or one of four pumps are tripped accidently due to loss of offisite power. Effects of ocean waves and tides on the steady-state and the transient operations are also studied. Water column separation in taken into account whenever necessary by means of a simplified physical model.

Online Load Estimation Method of High Frequency Induction Heat System (고주파 유도가열 장치의 실시간 부하예측 기법에 관한 연구)

  • Park, Tae-Joon;Kim, Tae-Won;Lee, Seung-Hee;Lee, Jin-Hee;Han, Mu-Ho;Lee, Hwang-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.123-124
    • /
    • 2010
  • 본 논문은 고주파 유도가열 장치의 실시간 부하 예측 기법을 제안한다. 인버터 출력전압과 콘덴서 양단전압을 센싱하여 adaptive parameter estimation 기법을 이용하여 피가열체인 부하의 등가저항과 인덕턴스를 구한다. 제안된 방법을 이용하여 부하 발열량과 콘덴서 뱅크의 Q factor를 실시간 예측할 수 있다. 콘덴서 뱅크의 Q factor를 통해 부하 부담률을 알 수 있으므로 뱅크의 파손 등의 사고를 미연에 방지 할 수 있게 한다. 본 논문에서 제안한 알고리즘의 타당성을 시뮬레이션을 통해 확인하였고 모의실험장치에 적용하여 실험을 통해 검증하였다.

  • PDF

A study on static condenser planning method & applying case (정전콘덴서 계획기법 및 적용사례 연구)

  • Chang, Jae-Won;Kim, Tae-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.6-8
    • /
    • 2002
  • 매년 증가하는 수요에 맞추어 원활하게 전력을 공급하기 위해서는 발전력 증대, 송전선로 건설 등의 유효전력 공급설비 확충 뿐만아니라 적정한 전압보상 설비가 필요하다. 이에따라 한국전력공사에서는 전력계통의 적정전압유 지를 위한 정전콘덴서 설치계획을 매년 수립 시행해오고 있다. 그러나, 최근의 전력산업 구조개편에 의한 계통운영여건 변화, 수도권의 발전력대비 수요 점유비의 지속 증가 등 무효전력 수급관련 주변여건의 변화로 보다 정밀한 계획수립에 대한 요구가 심화되고 있다. 예년의 정전콘덴서 설치계획 수립이 단순히 적정전압유지를 위한 소극적 차원에서 이루어졌다면 근래의 계획은 전력계통 의 전압안정도 확보는 물론 계통제약 최소화까지 고려되는 적극적인 방향으로 변화되고 있다. 본 고에서는 이렇게 다양화되고 있는 여건 변화에 부응하기위해 필요한 무효전력설비 계획관련 방법론 고찰과 이를 토대로 검토된 2003년 우리나라 계통 적용사례를 다루었다.

  • PDF

Development of a Novel Inverter Circuit for Motoring and Generating Operation in SRM Reluctance Machine (SRM 전동 및 발전동작을 위한 새로운 인버터의 개발)

  • Park, Han-Woong;Park, Sung-Jun;Won, Tae-Hyun;Jung, Kee-Hwa;Kim, Cheul-U;Hwang, Young-Noon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.182-184
    • /
    • 1999
  • 회수에너지를 저장한 콘덴서전압을 이용하여 평활전류 구동방식에서 SRM이 전동기 영역으로 동작할 경우에는 콘덴서에 저장된 에너지 모두를 전동기영역에서 소모할 수 있으나, 발전모드가 장시간 유지되면 콘덴서의 에너지는 더 이상 저장할 수 없는 상태가 되는 치명적인 약점을 갖고 있다. 따라서 본 연구에서는 전동기 영역 및 발전기영역에서 평활전류 모드로 동작할 수 있는 인버터회로를 제안하고, 발전에너지를 효과적으로 사용할 수 있는 스위칭 방식을 돌출하였다.

  • PDF

Variable Speed Drive of Permenant Split­Capacitor Single Phase Induction Motor Using SHE PWM Inverters (SHE PWM 인버터를 이용한 영구 콘덴서형 단상 유도전동기의 가변속 구동)

  • 이수원;전칠환
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1751-1758
    • /
    • 2003
  • This paper describes speed control of a permanent split capacitor single phase induction motor using SHE PWM inverters. The inverter is controlled by V55 microprocessor and its range is larger than other systems. Due to the V/F control with SHE(Selected Harmonic Elimination) PWM, continuously variable speed is attained and THD(Total Harmonic Distortion) is decreased. This is verified by simulations and experimental results.

Analysis of a breakdown in 154 kV STATCON Bank condenser cell (154 kV STATCON Bank용 콘덴서 셀 절연파괴 원인분석)

  • Ju, H.J.;Kweon, D.J.;Kang, Y.W.;Shim, E.B.;Lee, S.I.;Lee, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.388-391
    • /
    • 2003
  • 154 kV 변전소에 설치 운전 중인 SC Bank 콘덴서 셀의 절연파괴 고장이 빈번하게 발생되어 전력계통의 운용 및 변전소 운전에 지장을 주는 사례가 많이 발생하였다. 따라서 이의 고장원인 진단을 통하여 대책수립을 하고자 EMTP(Electro-Magnetic Transient Program)를 이용하여 SC Bank의 정상상태시 과전압, 과전류에 의한 소손현상을 검토하고, 계통조건에 따른 공진점변화와 고조파에 따른 이상전압 및 콘덴서 셀 전압의 상승 현상을 검토 분석하고, 고조파 성분에 따른 과전압 및 과전류를 분석하여 대책을 제시한 사례연구의 결과이다.

  • PDF