• Title/Summary/Keyword: 컷아웃 스위치 퓨즈

Search Result 4, Processing Time 0.019 seconds

An Experimental Study on the Control of Duration time of Impulse Noise from a High Voltage COS Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음의 지속시간 제어에 관한 실험적 연구)

  • Song, Hwa-Young;Kim, Deok-Han;Lee, Jong-Suk;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.258-261
    • /
    • 2006
  • This study introduces the control of duration time of impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level over 150 dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study, the reactive type silencer has been utilized. And also electrical interrupting test was experimented. From the experimental results, the reactive type silencer has been shown to have the noise reduction of about 13 dB(A). It has been found that the electrical interception performance of the COS fuse was related to the control of the duration time of impulse noise.

  • PDF

Reactive Silencer Design for Suppressing Impulse Noise from a High Voltage Cut Out Switch Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음 저감용 반사형 소음기의 설계)

  • Song, Hwa-Young;Kim, Deok-Han;Lee, Jong-Suk;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.951-954
    • /
    • 2006
  • This Study introduces the design of a reactive type silencer for reducing impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level above 150dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study. the reactive type silencers have been utilized. The performance of noise reduction for them can be expressed by insertion loss. The reactive silencers have been tested for 23 different types with each different porosity, hole diameter and depth. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise. The one-stage, two-stage and three-stage reactive type silencers have been shown to have the insertion losses of about from 35dB (A) to 25dB(A).

  • PDF

An Experimental Study on the Propagation Characteristics and Reduction of Impulse Noises from a High Voltage COS Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음의 전파특성과 저감에 관한 실험적 연구)

  • Song, Hwa-Young;Ju, Kyung-Min;Lee, Dong-Hoon;Kang, Rae-Goog;Jung, Nak-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.71-74
    • /
    • 2005
  • This experimental study describes the propagation characteristics and reduction of impulse noises emitted from a high voltage COS(Cut Out Switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current. The peak sound Pressure above 150dB(A) is generated. In this study, an impulse noise generator is designed for generating the impulse noises similar to the noise level of COS fuse, which is utilized to test the noise reduction of a reactive silencer. The reactive silencers have been tested for 10 different types with each different porosity, hole diameter and length. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise and that its performance is closely connected with the porosity and hole diameter.

  • PDF

Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance (과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발)

  • Kim, Youn-Hyun;Kim, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.129-136
    • /
    • 2020
  • A Cut Out Switch (COS) is used for line protection and pole transformer protection in power systems. The COS used to protect the pole transformer is installed on the power side of the pole transformer to protect the electric equipment from fault currents. The COS is composed largely of a body and a fuse holder, and when the fault current is energized, the element of the fuse link in the fuse holder is melted to block the fault current. The arc generated when the COS fuse link is blown causes fire and noise, causing discomfort to residents in the surrounding area, and the arc flame can cause secondary damage to the peripheral device. In this study, a current-limiting COS fuse with improved overcurrent blocking performance rather than explosion type was developed to solve the arc and noise problems during COS operation. The overcurrent breaking performance of the current-limiting COS improves the reliability by developing a striker and COS fuse bracket. In addition, this study aimed to verify the performance of the developed current-limiting COS fuse through a test at an authorized institution.