• Title/Summary/Keyword: 캐니스터

Search Result 38, Processing Time 0.027 seconds

A Verification of Tip-over Analysis of a Dry Concrete Storage Cask under The Accident Conditions by a Test for the 1/3 Scale Model (사고조건하의 건식저장용기 전복해석검증을 위한 1/3 축소모델의 시험)

  • Kim Dong-Hak;Seo Ki-seog;Lee Ju-Chan;Jung Ki-Jung;Cho Chun-Hyung;Choi Byung-Il;Lee Heung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.237-246
    • /
    • 2005
  • A tip-over test of the 1/3 scale model is conducted to verify the tip-oner analysis of a dry concrete storage cask under a hypothetical accident condition. The tip-oner analysis is executed using the velocity at each point which are determined from the initial angular velocity as the initial conditions of the model just before the impact. To confirm the structural integrity of the canister of a dry concrete storage cask, the non-detective testing such as Liquid Penetrants testing and Ultrasonic Testing are conducted. The strains and tile accelerations acquired by the tip-over test are compared with those by the analysis to verify the tip-over analysis. The lid of a storage calk are plastically deformed at the impact point. Liquid

  • PDF

Development and Characteristic Study of a Portable Gas Chromatography (소형 GC 모듈의 개발 및 특성)

  • Lee, Myeong-Gi;Oh, Jun-Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.2
    • /
    • pp.157-162
    • /
    • 2011
  • In the present study, we developed a portable GC module for real-time, quantitative determinations of gas mixtures in air sample. Capillary or packed column was coiled together with a heater wire and thermocouple in a small case. Together with the small and light weight sensors and valves as well as the rechargeable carrier gas canister, which permits collection and separation of samples, this system can determine the components of complex mixtures of air contaminants at low concentrations with a duty cycle of 10 min. When measured the various samples with a FID and TCD, the system showed, for a capillary column, a good resolution (R=8.3), high sensitivity, reproducibility, and linear dynamic range greater than three orders of magnitude. These results indicate that the portable GC module is expected to be used for a wide range of applications, particularly for in situ environmental monitoring, chemical processes, and regulation of contaminant emission.

Improving Drug Quantity Accuracy using Displacement Sensor in Pharmacy Automation Management System (약국 자동화 관리 시스템에서 변위 센서를 이용한 약품 수량 정확도 개선)

  • Park, Kiyoung;Kim, Hoyoung;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.9
    • /
    • pp.1032-1037
    • /
    • 2019
  • In the existing pharmacy automation system, quantity control was carried out only in the memory without first measuring the quantity of the medicine and during the operation of the facility. As a result, the number of drugs that have already been deducted during operation at the time of a facility error has not been managed. Serious problems are caused by important medicines that need to be managed because of lack of quantity control. In addition, the user had to refill the drug when it was exhausted because the user could not know the amount of the drug outside the facility. When the drug was out of stock, the facility was operating with loss of time to restart and the time to replenish the drug. Thus, in this paper, we designed and applied system to control the quantity of medicines frequently by adding displacement sensors to the robot of the facility.

Comparison of Measurement Methods for Volatile Organic Compounds in Ambient Air Using Adsorbent Tubes and Canisters (흡착관과 캐니스터를 이용한 대기 중 휘발성유기화합물 측정방법의 비교 평가)

  • Baek, Sung-Ok;Seo, Young-Kyo;Heo, Gwi-Seok;Jeon, Chan-Gon;Lee, Min-do;Han, Jin-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.3
    • /
    • pp.305-319
    • /
    • 2016
  • This study was carried out to evaluate the performance of two sampling methods, i.e., adsorbent tubes and canisters, for the measurement of ambient volatile organic compounds (VOCs). A total of 24 target VOCs were selected from a list of 48 priority hazardous air pollutants (HAPs) in Korea. The two sampling methods were investigated with a wide range of performance criteria such as repeatability, linearity, and lower detection limits. In addition, mean relative errors (MRE) and mean duplicate precisions (MDP) were estimated by inter-lab comparison studies for duplicate field samples. Precisions for the two methods appeared to be well comparable with the performance criteria recommended by USEPA TO-15 and TO-17 for canister and adsorbent methods, respectively. Correlations and variations between the VOCs concentrations determined by the two methods were generally good in most cases. However, MREs and MDPs for individual VOCs appeared to be widely ranged, depending on each VOC. This implies that the two methods have its own advantages and disadvantages in determining a variety of VOCs in ambient air, and neither of which has absolute superiority. Finally, 9 of 24 VOCs were found to be difficult to determine by either methods due to their unstability in a canister, and lack of appropriate standard materials. Thus, it is suggested that development of measurement methods for such unstable VOCs is an urgent task from a viewpoint of HAPs management.

Study on the Assessment of Dose Equivalent due to the Inhalation of $^{222}Rn$ and Its Daughters in Indoor Air (실내 $^{222}Rn$$^{222}Rn$ 딸핵종에 의한 피폭선량 해석연구)

  • Jun, Jae-Shik;Chai, Ha-Seok;Yi, Chul-Young;Cho, Hyuck;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.16-24
    • /
    • 1995
  • Assesment of dose equivalent given by inhaled $^{222}Rn$ and its progeny has been carried out based on the concentrations of $^{222}Rn$ and its daughters in indoor air, and equilibrium factor between them measured by charcoal canister method and alpha spectrometry. Assuming the occupancy factor to be 0.8, and breathing rate to be $0.75m^3\;h^{-1}$ for public and $1.2m^3\;h^{-1}$ for occupational exposure, respectively, the regional lung dose 대valent and the resulting annual effective dose equivalent due to the inhalation of $^{222}Rn$ and its daughters in indoor air were evaluated by use of three different lung models, namely, Jacobi-Eisfeld, James-Birchall and ICRP model.

  • PDF

The Study on Analysis Method and Performance Evaluation of Portable GC/MS (휴대용 GC/MS 성능검사 및 분석방법 연구)

  • Park, Yuonshin;Noh, Hyeran;Yang, Heeseon;Seok, Gwanseol
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.249-258
    • /
    • 2013
  • Recieved Mar. 06, 2013 Revised Mar. 29, 2013 Accepted Sep. 11, 2013In this study, we evaluated the method performance and the optimum sample injection method of the portable GC/MS(HAPSITE) which were designed to operate on scene of chemical accidents. Chemicals used for performance test were vinyl chloride(VC), methyl chloride(MC), benzene(Bz), toluene(Tol). CRM(Certified Reference Material) Manufactured by KRISS(Korea Research Institute of Standards and Science) was used as the standard gas. The results showed that 1) Among three sample injection methods(Cylinder, Silico canister, and Bag), bag was identified as the most appropriate sample injection method. Bag material and capacity did not significantly affect the results. The most ideal reproducibility occurred at the 2-minute point of the purge time in the loop and tenax methods. 2) Performance evaluation of HAPSITE was conducted. Evaluation items were reproducibility, linearity, method detection limit, etc. Tenax concentration method was appropriate for larger molecules and Carbopack concentration method was suitable for smaller molecules.

Activation Analysis of Dual-purpose Metal Cask After the End of Design Lifetime for Decommission (설계수명 이후 해체를 위한 금속 겸용용기의 방사화 특성 평가)

  • Kim, Tae-Man;Ku, Ji-Young;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.343-356
    • /
    • 2016
  • The Korea Radioactive Waste Agency (KORAD) has developed a dual-purpose metal cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. The metal cask was designed in compliance with international and domestic technology standards, and safety was the most important consideration in developing the design. It was designed to maintain its integrity for 50 years in terms of major safety factors. The metal cask ensures the minimization of waste generated by maintenance activities during the storage period as well as the safe management of the waste. An activation evaluation of the main body, which includes internal and external components of metal casks whose design lifetime has expired, provides quantitative data on their radioactive inventory. The radioactive inventory of the main body and the components of the metal cask were calculated by applying the MCNP5 ORIGEN-2 evaluation system and by considering each component's chemical composition, neutron flux distribution, and reaction rate, as well as the duration of neutron irradiation during the storage period. The evaluation results revealed that 10 years after the end of the cask's design life, $^{60}Co$ had greater radioactivity than other nuclides among the metal materials. In the case of the neutron shield, nuclides that emit high-energy gamma rays such as $^{28}Al$ and $^{24}Na$ had greater radioactivity immediately after the design lifetime. However, their radioactivity level became negligible after six months due to their short half-life. The surface exposure dose rates of the canister and the main body of the metal cask from which the spent nuclear fuel had been removed with expiration of the design lifetime were determined to be at very low levels, and the radiation exposure doses to which radiation workers were subjected during the decommissioning process appeared to be at insignificant levels. The evaluations of this study strongly suggest that the nuclide inventory of a spent nuclear fuel metal cask can be utilized as basic data when decommissioning of a metal cask is planned, for example, for the development of a decommissioning plan, the determination of a decommissioning method, the estimation of radiation exposure to workers engaged in decommissioning operations, the management/reuse of radioactive wastes, etc.

Microstructure of ZnO Thin Film on Nano-Scale Diamond Powder Using ALD (나노급 다이아몬드 파우더에 ALD로 제조된 ZnO 박막 연구)

  • Park, S.J.;Song, S.O.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.538-543
    • /
    • 2008
  • Recently a nano-scale diamond is possible to manufacture forms of powder(below 100 nm) by new processing of explosion or deposition method. Using a sintering of nano-scale diamond is possible to manufacture of grinding tools. We have need of a processing development of coated uniformly inorganic to prevent an abnormal grain growth of nano-crystal and bonding obstacle caused by sintering process. This paper, in order to improve the sintering property of nano-scale diamond, we coated ZnO thin films(thickness: $20{\sim}30\;nm$) in a vacuum by ALD(atomic layer deposition) Economically, in order to deposit ZnO all over the surface of nano-scale diamond powder, we used a new modified fluidized bed processing replaced mechanical vibration effect or fluidized bed reactor which utilized diamond floating owing to pressure of pulse(or purge) processing after inserted diamond powders in quartz tube(L: 20 mm) then closed quartz tube by porosity glass filter. We deposited ZnO thin films by ALD in closed both sides of quartz tube by porosity glass filter by ALD(precursor: DEZn($C_4H_{10}Zn$), reaction gas: $H_2O$) at $10^{\circ}C$(in canister). Processing procedure and injection time of reaction materials set up DEZn pulse-0.1 sec, DEZn purge-20 sec, $H_2O$ pulse-0.1 sec, $H_2O$ purge-40 sec and we put in operation repetitive 100 cycles(1 cycle is 4 steps) We confirmed microstructure of diamond powder and diamond powder doped ZnO thin film by TEM(transmission electron microscope) Through TEM analysis, we confirmed that diamond powder diameter was some $70{\sim}120\;nm$ and shape was tetragonal, hexagonal, etc before ALD. We confirmed that diameter of diamond powders doped ZnO thin film was some $70{\sim}120\;nm$ and uniform ZnO(thickness: $20{\sim}30\;nm$) thin film was successfully deposited on diamond powder surface according to brightness difference between diamond powder and ZnO.