• Title/Summary/Keyword: 침투성능

Search Result 444, Processing Time 0.032 seconds

A Study on the Aging Behavior of Ship Organic Coating by the Flow Induced Shear Stress (유동 전단응력에 의한 선박 유기도막의 열화거동 연구)

  • Park Hyun;Park Jin-Hwan;Ha Hyo-Min;Chun H.H.;Lee In-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.1 s.24
    • /
    • pp.9-14
    • /
    • 2006
  • Analysis has been made of the anti-corrosive property of organic coating under the shear stress of the flow by means of AC impedance method. Marine anti-corrosive painted panels were placed in the water channel with varying flow rate, thereby experiencing varying flow shear stress on the surfaces. The velocities of the salt water were ranged from 1.48 to 5.2 m/s and the coating thickness of from $70{\mu}m\;to\;140{\mu}m$. For all coating thicknesses investigated, the poorer anti-corrosive property and the lower adhesion strength have been found for the higher shear stress. It has been found that the shear stress accelerates the aging of organic marine coatings.

  • PDF

Enhancing Construction Productivity and Quality Through Waterproofing Equipment Technologies (생산성 및 품질향상을 위한 방수공사의 장비 활용 시공기술)

  • Kim, Han-Sic;Ha, Jung-Soo;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.4
    • /
    • pp.429-440
    • /
    • 2023
  • This research investigates the deployment of waterproofing technologies in construction, with a specific focus on augmenting worker safety, work environment, and solve the difficulty of securing skilled workers. Implementing liquid waterproofing cement equipment resulted in a remarkable increase in adhesion performance by around 20%, coupled with a twofold acceleration in operational speed. The application of primer spraying apparatus led to a two-fold improvement in both penetration and adhesion performance, concurrently boosting the work speed by approximately the same factor. With urethane spraying equipment, the workload could be reduced to a third for the same layer thickness, adhesion performance enhanced by approximately 1.4 times, and workability improved by about 1.4 to 1.5 times. These findings suggest that such technological interventions can potentially enhance work efficiency, improve the quality of output, and mitigate safety accidents that are commonplace in manual operations. Furthermore, these advancements present promising solutions to the ongoing challenges of sourcing highly-competent workers in the industry.

Analysis of outflow reduction effect of bioretention in small watersheds during short-term rainfall (단기강우 시 소유역내 식생저류지의 유출량 저감성능 분석)

  • Kim, Jaemoon;Baek, Jongseok;Kim, Byungsung;Kwon, Soonchul
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.12
    • /
    • pp.855-869
    • /
    • 2023
  • Low Impact Development (LID) technology has been attracting attention as a countermeasure to solve frequent flood damage in urban areas. LID involves recovery of the natural circulation system based on infiltration and storage capacity at the site of rainfall runoff, to protect the aquatic ecosystem from the effects of urbanization. Bioretention as an element of LID technology reduces outflow through storage and infiltration of storm water runoff, and minimizes the effects of non-point pollutants. Although LIDs are being studied extensively, the amount of quantitative research on small watersheds with bioretention has been inadequate. In this study, a bioretention model was constructed in a small watershed using Korea-Low Impact Development Model (K-LIDM), which was conducted quantitative hydrologic analysis. We anticipate that the results of the analysis will be used as reference data for future bioretention research related to watershed characteristics, vegetation type, and soil condition.

An Experimental Evaluation on Performance of Surface Protector for Concrete Structures (콘크리트 구조물 표면 보호재의 성능에 대한 실험적 평가)

  • Nam, Yong-Hyuk;Chung, Young-Jun;Jang, Suk-Hwan;An, Young-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.157-163
    • /
    • 2006
  • This study is on the evaluation of double surface protection method using water repellent primer and final top coat to protect concrete. Water repellent agent has been applied on the final top coat to protect concrete. However, to make up for the weakness to the ultraviolet of the water repellent, the work procedure of these protectors is done vice versa. This combination of protectors was compared with existing ones in this study. Even though the final top coat was applied on the water repellent primer, its adhesive strength met to KS F 4936-' 03 with other protectors used in this study. All surface protectors used in this study were excellent in protecting concrete. Especially, in case of applying with final top coat in conjunction with water repellent primer, the resistance against chloride ion penetration and neutralization by $CO_2$ was more efficient than other surface protectors used in this study under this given condition.

Fire Resistance Properties of High Strength Concrete Column using ECC Permanent Form (ECC 영구 거푸집을 활용한 고강도콘크리트 기둥부재의 내화특성)

  • Kim, Yong-Ro;Song, Young-Chan;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.957-960
    • /
    • 2008
  • In this study, it was investigated fire resistance properties of high strength concrete column using Engineered Cementitious Composites(ECC) permanent form as a countermeasure for explosive spalling of concrete on fire. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete if it is developed manufacturing technique and scheme for application controlling heat penetration through interface of permanent form and high strength concrete, and setting up mix proportion and thickness of ECC.

  • PDF

원자력시설의 제염해체 공정중 분진처리 성능평가

  • 이기원;최병선;이후근;오원진;이병직;박현수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.307-312
    • /
    • 1997
  • 원자력시설의 콘크리트 표면제염 및 절단을 효과적으로 수행하기 위해서는 먼저 방사성물질이 제염구역의 외부로 누출되지 않도록 작업구역을 비방사성 구역과 분리하고, 국부적으로 오염된 콘크리트 표면을 제염하는 기술, 해체 절단하는 기술 및 경제적인 방법으로 방사성물질의 확산을 최소화하는 분진제거 기술 등이 개발되어야 한다. 따라서 본 논문에서는 원자력시설의 콘크리트 표면제염 및 절단시 발생되는 콘크리트 분진처리 필터시스템을 개발하기 위하여, 중량 및 고밀도 콘크리트 내부로의 세슘 및 스트론튬 핵종의 침투깊이 실험을 수행하였으며, 다중 사이클론을 이용하여 DOP 에어로졸 및 콘크리트 표면절단 장비인 scabbier에 의해 발생한 중량 및 고밀도 콘크리트 분진의 특성을 분석하고 포집효율 성능시험을 수행하였다. 또한 사이클론 성능평가 프로그램을 작성하여 사이클론의 포집효율을 예상하였으며 이를 실험값과 비교하였다.

  • PDF

Development on Antibiotic Concrete Mixed with Antibacterial Metals and Metallic Salts (금속 및 금속염계 항균제가 혼입된 항균 콘크리트 개발)

  • Choi, Hong-Shik;Heo, Kwon;Lee, Ho-Beom;Lee, Si-Woo;Kwak, Hong-Shin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.2
    • /
    • pp.136-143
    • /
    • 2013
  • In the sewage structures and wastewater facilities, concrete is exposed to hydrogen sulfide ($H_2S$) which acts as an acid material in a solution, and a strongly acidic sulfate ion ($SO{_4}^{-2}$) is generated by a sulfuric bacteria. Hence, a degradation of concrete with biochemical corrosion would be accelerated. Finally, durability of concrete and concrete structures may be greatly reduced. In this study, in order to remove the hydrogen sulfide which is used by the sulfuric bacteria organic-biologically, the antibiotic metal and metallic salt powders were mixed to concrete, and a suppressing performance of the sulfate ion was assessed. For the sulfuric acid bacteria, a comparative evaluation of antimicrobial performance on neutralized concrete specimens were carried out, also by a rapid chloride penetration test, chloride penetration depths and diffusion coefficients were measured for antibiotic concrete in accordance with the amount of metal and metallic salt-based antibacterial agents. Eventually, by an observation of the biochemical state of the surface of concrete specimens exposed outdoors, the performance and applicability of antibiotic concrete were confirmed.

Durability Evaluation of Cement Concrete Using Ferrosilicon Industrial Byproduct (페로실리콘 산업부산물 활용 시멘트 콘크리트의 내구성능 평가)

  • Chang-Young Kim;Ki Yong Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.1
    • /
    • pp.89-96
    • /
    • 2023
  • In this paper, a ferrosilicon by-product was evaluated to confirm the feasibility of recycling it as supplementary cementitious material of ordinary Portland cement in concrete. Three different levels of replacement ratio (10 %, 20 % and 30 % of total binder) were applied to find which is the most beneficial to be used as a binder. Ferrosilicon concrete was initially assessed at setting time and compressive strength. Durability was evaluated by the resistance to chloride penetration test(RCPT) and alkali-silica reaction(ASR) with a comparison to silica fume concrete due to their similarity in chemical composition. The porosimetry and X-ray diffraction analysis along with energy dispersive X-ray spectroscopy give information on the microstructural characteristics of the ferrosilicon concrete. It was found that 10 % ferrosilicon concrete has higher strength while 20 %, 30 % have lower strength than OPC concrete. However, chemical resistance to chloride attack is higher when replacement is increased. Compared to silica fume, the durability of ferrosilicon might be less efficient however, it is obviously beneficial than OPC. High SiO2 content in ferrosilicon results in producing more C-S-H gel which could make denser pore structure. Most of the risk of alkali silica reaction to silicate binders through length change tests was less than 0.2 %, and both mortar using ferrosilicon and silica fume showed better resistance to alkali silica reaction as the substitution rate increased.Reuse of industrial waste rather than producing highly refined additives might reduce environmental load during manufacture and save costs.

Effect of Internal Curing by Super-Absorbent Polymer (SAP) on Hydration, Autogenous Shrinkage, Durability and Mechanical Characteristics of Ultra-High Performance Concrete (UHPC) (고흡수성 수지(SAP)를 이용한 내부양생이 초고성능 콘크리트(UHPC)의 수화반응, 자기수축, 내구성 및 역학적 특성에 미치는 영향)

  • Kang, Sung-Hoon;Moon, Juhyuk;Hong, Sung-Gul
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.3
    • /
    • pp.317-328
    • /
    • 2016
  • This research intends to understand the impact of super-absorbent polymer (SAP) as an internal curing agent in Ultra-High Performance Concrete (UHPC). Two different types of SAPs of acrylic acid (SAP_AA) and acrylic acid-co-acrylamide (SAP_AM) were examined with UHPC formulation. Isothermal calorimetry and x-ray diffraction experiments revealed the impact of polymers with the different chemical bonds on cement hydration. To test its feasibility as a shrinkage reducing admixture for UHPC, a series of experiments including flowability, compressive strength, rapid chloride permeability and autogenous shrinkage profile was performed. While both SAPs showed a reduction in autogenous shrinkage, it has been concluded that the SAP size and chemical form significantly affect the performance as an internal curing agent in UHPC by controlling cement hydration and porosity modification. Between the tested SAPs, SAP_AM which absorbs more water in UHPC than SAP_AA, shows better mechanical and durability performance.

Analysis of Optimal Infiltraction Route using Genetic Algorithm (유전자 알고리즘을 이용한 최적침투경로 분석)

  • Bang, Soo-Nam;Sohn, Hyong-Gyoo;Kim, Sang-Pil;Kim, Chang-Jae;Heo, Joon
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.1
    • /
    • pp.59-68
    • /
    • 2011
  • The analysis of optimal infiltration path is one of the representative fields in which the GIS technology can be useful for the military purpose. Usually the analysis of the optimal path is done with network data. However, for military purpose, it often needs to be done with raster data. Because raster data needs far more computation than network data, it is difficult to apply the methods usually used in network data, such as Dijkstra algorithm. The genetic algorithm, which has shown great outcomes in optimization problems, was applied. It was used to minimize the detection probability of infiltration route. 2D binary array genes and its crossover and mutation were suggested to solve this problem with raster data. 30 tests were performed for each population size, 500, 1000, 2000, and 3000. With each generation, more adoptable routes survived and made their children routes. Results indicate that as the generations increased, average detection probability decreased and the routes converged to the optimal path. Also, as the population size increases, more optimal routes were found. The suggested genetic algorithm successfully finds the optimal infiltration route, and it shows better performance with larger population.