• Title/Summary/Keyword: 침수방지

Search Result 169, Processing Time 0.031 seconds

The development for flooding prevention apparatus of electrical equipment using air pressure (공기압을 이용한 전기설비 침수 방지 장치 개발에 관한 연구)

  • Kim, Gi-Hyun;Jean, Hyun-Jae;Lee, Sang-Ick;Bae, Suk-Myong;Lee, Jae-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.281-284
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment(Pad-mounted Transformer and Switch). In case of installing the power equipment at flood danger territory, we are necessary to the product development, the product is that water does not come in the inside the power equipment. Product of pressure maintaining are established on the basic frame and sensor operates at the flooding occurrence and is maintained a shutting tightly structure and it is a method. The product which is produced the reliability of the product it confirmed a flooding yes or no from the condition which puts in the water tank and it verified. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation and a security of the flood protection product.

  • PDF

The Evaluation of Detention Reservoir Safety using Equi-Flooding Line Theory (등위험도선이론(等危險度線理論)에 의한 유수지(遊水池) 안전도평가(安全度評價))

  • Choi, Song Yeol;Shim, Jae Hyun;Lee, Won Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.131-139
    • /
    • 1992
  • Based on the equi-flooding line theory, this study suggests method of evaluating safety of detent tion reservoirs with drainage pumping facilities in Seoul metropolitan area, and derives equi-flooding lines according to destruction frequency for each detention reservoir. In most part of detention reservoirs, its flood prevention are so much dependent upon drainage capacity that inland flooding prevention can be serious problems in case of its malfunction. In this study, the detention reservoirs which are below 5 year destruction frequency estimated as 29.3%, and below 10 year as 39.6% of the total. To improve reservoir safety, the detention reservoir capacities (including drainage and pumping capacity) should be upgraded above 20 year in its destruction frequency, and its reinforcement capacities are calculated.

  • PDF

Optimum Scale Evaluation of Sedment Basin Design by Soil Erosion Estimation at Small Basin (소유역의 토사유실량에 따른 유사저류지 설계적정성 검토)

  • Lee, Sang-Jin;Choi, Hyun;Kwak, Young-Joo;Lee, Bae-Sung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.2 s.40
    • /
    • pp.25-31
    • /
    • 2007
  • The recent frequent heavy rainfall has caused an increased in soil erosion and the soil drain which drained soil has caused decreased in channel radius and environmental problems by turbidity. In this study, the optimum size of the sediment basin was tested with soil erosion estimated from the Universal Soil Loss Equation (USLE) in the basin using by GIS data. The results show that the estimated soil erosion and the designed soil deposit are $72.1\;m^3$ and $85.0\;m^3$ respectively and the size of sediment basin is proper. In this study the water depth was calculated from the Hec-Ras model to test the stability of the bank and to prove submersion of the inside fields from stream overflow.

  • PDF

An Estimation of Head Loss Coefficients at Surcharged Manhole with 90 Degree Bend Using Numerical Model (수치모형을 이용한 과부하 $90^{\circ}$ 접합맨홀에서의 손실계수 산정)

  • Kim, Jung-Soo;Lim, Ga-Hui;Han, Chyung-Suck;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.165-165
    • /
    • 2011
  • 현재 계획 또는 설계 단계에서 수행되고 있는 관거 시설의 수리계산에는 연결관 내에서의 마찰손실만을 감안하여 수행하고 있으며, 맨홀에서의 에너지 손실은 고려되지 않는 실정이다. 그러나 연결관 내부와 맨홀의 내부는 여러 가지 수리학적 조건이 다르므로 에너지 손실이 발생하게 된다(최원석과 송호면, 2002). 더욱이 직선으로 연결된 중간맨홀보다 유입관과 유출관이 $90^{\circ}$의 각도로 접합된 합류맨홀은 연결 구조상 유수교란에 의한 에너지 손실이 커질 것으로 예상됨에도 불구하고 현재 실무에서 우수 배수시설의 설계 시 직선 연결맨홀과 $90^{\circ}$ 접합맨홀의 손실을 구별하지 않고 사용하고 있는 실정이다. 그러므로 $90^{\circ}$ 접합맨홀에서 우수관거 시스템의 우수 배제 능력을 증가시켜 도심지의 침수를 방지하기 위한 관거시설의 적정 설계 기준이 필요하며, 합리적인 설계 기준을 제시하기 위하여 $90^{\circ}$ 접합맨홀 내에서의 수두 손실을 분석할 필요가 있다. 본 연구에서는 수리모형 실험의 물질적 및 시간적 한계를 극복하기 위하여 일반적으로 3차원 유체거동의 특성분석에 많이 사용되는 Fluent 6.3 모형을 이용하여 과부하 $90^{\circ}$ 접합맨홀에서의 흐름특성을 수치모의 하였으며, 맨홀 내 손실수두의 변화를 계산하여 손실계수를 산정하였다. 맨홀 및 접합 관거의 기하 모형의 격자망은 수치해석의 안정성 확보를 위하여 그림 1과 같이 6면체 격자로 구성하였다. 또한 $90^{\circ}$ 접합맨홀에서 급격한 와류에 의해 발생하는 에너지 손실을 저감하기 위하여 $90^{\circ}$ 접합맨홀의 내부 형상 및 접합 조건을 변화시켜 손실계수를 산정하였다. 수치모형의 적용 결과 맨홀 내에서의 유속변화, 수심변화 및 압력변화에 대해서는 수리모형 실험 결과와 유사한 경향을 나타내고 있으며, 수치모형에 의하여 산정된 $90^{\circ}$ 접합맨홀에서 에서의 손실계수 값과 수리모형에 의하여 산정된 손실계수 값이 거의 유사하게 나타났다.

  • PDF

Analysis of Electric Shock Accidents and Check Results in Domestic and Foreign low-Voltage Handhole (국내.외 저압지중함 감전사고사례 및 점검결과의 분석)

  • Kim, Chong-Min;Han, Woon-Ki;Bang, Sun-Bae;Kim, Han-Sang;Shim, Keon-Bo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.124-131
    • /
    • 2008
  • Recently underground electrical power distribution is increased because people attach importance to aesthetics of the downtown areas. Lew-voltage handhole of underground distribution line for joint and branch point is mainly installed at the sidewalk. So, pedestrian can get a electric shock if fault is occurred in the low-voltage handhole. Furthermore the street was flooded by recently an unusual change in the weather. Fault is occurred in the low-voltage handhole that may create a shock hazard for the human body because a person's body resistance lower due to effect of water. This paper analyses causes of electric shock accidents and check results at the low-voltage handhole. At a result of analysis, the causes of electric shock accidents in domestic and foreign low-voltage handhole are same but environmental conditions of low-voltage handhole are different In the future, the analytical data can be applied to prevent the electric shock at the low-voltage handhole, and can be used to basic data for the improving installment of low-voltage handhole.

Analysis of Runoff Reduction Characteristics According to Alloted Detention System in Urban Area (도시유역의 분담저류 방식에 따른 유출저감특성 분석)

  • Kim, Ji -Tae;Kwon, Wook;Kim, Young-Bok;Kim, Soo-Jun
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.11 s.172
    • /
    • pp.915-922
    • /
    • 2006
  • National Emergency Management Agency is planning a flood disaster mitigation system in urban area. This research is about analysis of runoff reduction efficiency of the alloted detention system which is one of flood disaster mitigation systems in urban area. The alloted detention system is composed of small to middle size detention facilities located in up and middle stream of urban basin. To analyze runoff reduction efficiency of alloted detention system, basic runoff analysis in test area has been carried out and runoff characteristics with size and locations of detention facilities has been simulated. The results of simulation are showing that alloted detention system can reduce the discharge of main stream and detention facilities' size and locations are major parameters of runoff reduction efficiency. It is concluded that alloted detention system can be a useful method in urban area's flood disaster mitigation and can secure safety against flood damages in urban areas.

Analysis of Stream Characteristics at Combine Junction Manhole Using Fluent Model (Fluent 모형을 이용한 합류 맨홀에서의 흐름특성 분석)

  • Kim, Jung-Soo;Chio, Hyun-Soo;Kim, Hyung-Min;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.649-653
    • /
    • 2010
  • 일반적으로 계획 또는 설계 단계에서 수행되고 있는 관거 시설의 수리계산에는 연결관 내에서의 마찰손실만을 감안하여 수행하고 있으며, 맨홀에서의 에너지 손실은 고려되지 않는 실정이다. 그러나 연결관 내부와 맨홀의 내부는 여러 가지 수리학적 조건이 다르므로 에너지 손실이 발생하게 된다. 더욱이 직선으로 연결된 중간맨홀보다 두 개의 유입관과 한 개의 유출관으로 구성된 합류맨홀은 연결 구조상 유수교란에 의한 에너지 손실이 커질 것으로 예상됨에도 불구하고 현재 실무에서 우수 배수시설의 설계 시 직선 연결맨홀과 합류맨홀의 손실을 구별하지 않고 사용하고 있는 실정이다. 그러므로 합류맨홀에서 우수 관거 시스템의 우수 배제 능력을 증가시켜 도심지의 침수를 방지하기 위한 관거시설의 적정 설계 기준이 필요하며, 합리적인 설계 기준을 제시하기 위하여 합류 맨홀 내에서의 수두 손실을 분석할 필요가 있다. 본 연구에서는 수리 모형 실험의 물질적, 시간적 한계를 극복하기 위하여 일반적으로 3차원 유체거동의 특성분석에 많이 사용되는 Fluent 6.3 모형을 이용하여 과부하 합류 맨홀에서의 흐름특성을 수치모의 하였으며, 맨홀 내 손실수두의 변화를 계산하여 손실계수를 산정하였다. 계산된 손실계수는 수리모형 실험을 통하여 산정된 손실계수와 비교하였다. 또한 동일한 수치모의 해석 조건을 실제 합류맨홀에 적용하여 실제 합류 맨홀의 규모 변화에 따른 손실계수를 산정하였다. 수치모형의 적용 결과 맨홀 내에서의 유속변화, 수심변화 및 압력변화에 대해서는 수리모형 실험 결과와 유사한 경향을 나타내고 있으며, 수치모형에 의하여 산정된 합류 맨홀에서의 손실계수 값과 수리모형에 의하여 산정된 손실계수 값이 거의 유사하게 나타났다. 또한 동일한 수치모의 해석 조건을 실제 합류맨홀에 적용하여 합류맨홀의 규모 변화에 따른 손실계수를 산정하였으며, 산정된 손실계수는 우수관거 시스템의 설계 및 평가에 사용가능하리라 판단된다.

  • PDF

A Study on the Comparison of Resistance Performance for Shape of Fin Keel of Sailing Yacht (세일링요트 핀킬 형상별 저항특성 비교연구)

  • Choo Kyung-Hoon;Sim Sang-Mok;Park Choung-Kwan;Jin Song-Han;Kwon Seong-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.30 no.5 s.111
    • /
    • pp.375-379
    • /
    • 2006
  • The keel attached on bottom of hull part prevents yacht from flowing sideway by sailing posture. The keel remove a heel moment and make the force of stability. The selection of suitable keel is important bemuse it has an influence on the safety. Also the appendage attached on bottom of keel part lower ballast weight center and have influence on hull stability. The optimum shape about the keel is very important. So this study has compared with characteristics of resistance depending on the shape of the lower part of fin keel in the same surface of water submersion, we have attached three different types of models of lower part of fin keels to the model ships using circulating water channel and analyzed resistance characteristics per shape to arrive at the optimum shape of reduction of resistance.

A Study on the Comparison of Resistance Performance for shape of fin keel of sailing yacht (세일링요트 핀킬 형상별 저항특성 비교연구)

  • Choo Kyung-Hoon;Sim Sang-Mok;Park Choung-Kwan;Jin Song-Han;Kwon Seong-Hoon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.235-239
    • /
    • 2006
  • The keel attached on bottom of hull part prevents yacht from flowing sideway by sailing posture. So this study has compared with characteristics of resistance depending on the shape af the lower part of fin keel in the same surface af water submersion, we have attached three different types of models of lower part of fin keels to the model ships using circulating water channel and analyzed resistance characteristics per shape to arrive at the optimum shape of reduction of resistance.

  • PDF

Destructive Experiments on Erosion Control Vegetation Mats (침식방지 식생매트의 파괴실험)

  • Kim, Myoung-Hwan;Lee, Du-Han;Rhee, Dong-Sop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.668-668
    • /
    • 2012
  • 제방 비탈면 보호방법 중에서 식생매트를 사용하는 방법은 제방의 보호와 함께 자연친화적이면서 생태계의 보전 측면에서 유리하고 이와 아울러 심미적 효과와 비용의 적절성 등의 요건을 만족하기 때문에 최근 국내 자연형 하천정비에서는 다양한 종류의 식생매트들이 빈번히 사용되고 있다. 하지만 식생매트로 인한 제방의 비탈면 보호 효과에 대해서는 아직까지 정성적으로 분석된 예가 미흡하여 이에 관한 연구가 시급히 요구되고 있는 실정이다. 비탈면을 보호하는 비탈덮기는 생태계와 경관 등의 고려도 중요하지만 그보다 먼저 유수에 의한 파괴가 발생하지 않아야 한다. 따라서 제방의 비탈면 보호 효과가 다른 재료에 비해 상대적으로 취약할 수 밖에 없는 식생매트의 경우 적용범위와 한계를 명확히 하여야 잘못된 적용으로 인한 재해를 막을수 있을 것이다. 근래 들어 지역을 가리지 않는 국지성 폭우로 인한 홍수가 점차로 확대되고 있는 국내 상황을 고려할 때에도 식생매트의 한계와 적용범위의 결정은 매우 중요하다. 본 연구에서는 한국건설기술연구원 안동 하천실험센터 호안블록 시험구간에서 하류 10m 지점에서 시작하는 20m 구간에 두 종류의 식생매트를 교대로 설치하여 각각의 식생매트에 관한 파괴실험을 수행하였다. 두 종류의 식생매트 모두 코코넛 섬유를 원료로 사용하는 제품이며, 식생매트의 파괴 실험은 식생활착 이전의 상황을 재현하여 수행하였다. 이는 통상적으로 식생 활착 이전의 식생매트가 제방 비탈면을 보호하는 효과가 현저히 떨어지는 단점을 가지고 있기 때문에 이에 맞추어 본 실험에서는 식생매트의 자체의 단점과 한계를 파악하는 것을 목적으로 하였다. 실험 결과 두 종류의 식생매트는 모두 침수시 부력으로 인한 부유 현상과 식생매트 틈세 흐름으로 인한 기반층의 세굴 현상을 발견할 수 있었으며, 이러한 상황에서 식생매트를 고정하는 앵커가 매우 중요한 역할을 한다는 것을 발견할 수 있었다. 식생매트가 기반 토층에서 분리되어 파괴가 발생하는 유량조건은 각각 식생매트에 따라 서로 다르게 나타났는데, 이 또한 매트를 고정하는 앵커의 특성 때문인 것으로 판단된다.

  • PDF