• 제목/요약/키워드: 침기량

검색결과 10건 처리시간 0.021초

자연급기구내 플리머필터 설치 시 외기 침기량 분석에 관한 연구 (A study on performance of outdoor air flow rate through viovent for hybrid ventilation equipment)

  • 이성환;최종악
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1337-1342
    • /
    • 2009
  • This test was progressed in the test house of KICT as sectional research of Center for Sustainable Housing. It included a ventilation rate of hybrid ventilation equipment, temperature, and gas test using the SF-6. The purpose of this test is to demonstrate the performance of viovent by estimating an outdoor air flow rate through viovent which the flimmer filter is installed and decide the leakage after operating the constant airflow fan within a house. First, the outdoor airflow rate through viovent measured $130\;m^3/h$ more than a legal required ventilation rate, $104\;m^3/h$. And then it sufficiently satisfy a legal standard, 0.7 air change/h. Secondly, the result of this test exposes that the leakage in the residence is about $20{\sim}25%$. Especially, the outdoor air flowing through the gate occupies 50% of the total leakage.

  • PDF

에너지 저감형 그린홈 프로토타이핑을 위한 설계요소 분석 연구 (Analytic Study on the Design Elements for Energy Conservative Green-Home Prototyping)

  • 김정은;장성주;하미경;성혜연;김경완
    • KIEAE Journal
    • /
    • 제11권4호
    • /
    • pp.63-70
    • /
    • 2011
  • In respond to the global energy crisis and climate change, there have been many ongoing national efforts to develop a sustainable housing prototype followed by "2 million Green Home Project" in Korea. More than 50% of nation's population are currently living in apartment housing thus the country is seriously in need of developing green apartment prototype. In this research, we focused on energy-conservative green apartment design prototype that have both passive components and active systems explored in a systemic design approach. After selecting an existing basic apartment unit, we analyzed and compared statistical data with the simulated annual energy consumption to match these two data sets for validating simulation accuracy performed with TRNSYS package. We performed energy simulations with different passive design factors such as varied insulation thickness, window types and infiltration rates as well as the active design factors including boilers and lighting fixtures to analyze their impacts on the energy performance of the housing unit using TRNSYS software. As a result, we acquired significant energy reduction effect with explored design strategies but the life cycle cost analysis for the final design guidline would need to be performed. In this study, we focused on a systematic comparative energy analysis based on TRNSYS that can improve the design of a green apartment housing.

모헤어 개수, 틈새 길이 및 축소된 길이의 창문 기밀성 및 개폐력에 대한 실험적 연구 (Experimental Research of Window Air Tightness and Opening Force with Respect to Mohair Number, Clearance and Shortened Length)

  • 김승재;박종준;김영일
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.195-203
    • /
    • 2018
  • Mohair is widely used as an airtight material for filling the gap between a window frame and sash. The purpose of this study is to investigate infiltration rate and opening force of sliding windows according to the mohair installation conditions. Infiltration experimental apparatus was set up, and the experimental results were applied to windows to find a correlation between infiltration rates and opening forces. When 4 rows of mohair were installed, the infiltration rate increase became 27.1% per clearance length increase of 1 mm, and the infiltration rate decrease became 5.7% per shortened length increase of 0.1 mm. For 4 rows of mohair, the opening force decreased by 28.2% as the clearance increased by 1 mm, and it increased by 9.3% as the shortened length increased by 0.1 mm.

기존 단독주택의 침기량 산정법에 관한 연구 (A Study on the Calculation Method of Infiltration for Detached Houses)

  • 김길태;유정현;황하진;김경식
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.493-498
    • /
    • 2013
  • The purpose of this study is to find the infiltration of detached houses, for energy consumption analyses. The pressurization and depressurization method is used to determine infiltration. Blower door tests are expressed in terms of ACH 50, which stands for the hourly air change rate at 50 Pa of fan pressure. The ACH 50 of existing Detached Houses ranges from 5 to 50. Air infiltration is related to construction year and accuracy, maintenance conditions, and so on. When estimating the infiltration of random detached houses, the year used can be the base value of the infiltration rate from 0.25 to 2.0 times/h. The maintenance conditions, construction accuracy and repair affect the air infiltration 0 to 0.5 times/h, 0 to 0.3 times/h, 0 to 1 times/h, respectively.

외부바람과 연돌효과의 상호작용에 의한 고층주거 건물의 연간 침기량 분포 (The annual infiltration distribution caused by wind and stack effects in high-rise residential buildings)

  • 박주현;윤성민;송두삼;김용식
    • 도시과학
    • /
    • 제8권1호
    • /
    • pp.25-31
    • /
    • 2019
  • Infiltration affects indoor environmental and air quality and energy consumptions in buildings. Especially, airflow and the infiltration are more remarkable in high-rise buildings due to the air-driving forces (stack and wind effects). Thus, it is important to understand infiltration distributions in high-rise residential buildings. In this study, the weather-driven infiltration is characterized from the viewpoint of interactions between external wind and stack effect in high-rise residential buildings. To calculate accurately the annual infiltration distributions, this study also suggests an airflow and thermal simulation method with a two-step calibration of air-leakage data. The simulated results show (1) how the interaction between stack and wind effects induce infiltration types (outdoor and interzone air infiltration) and (2) how much the interzone air infiltration (being ignored in previous studies) occurs due to the stack effect, as well as the outdoor air infiltration rates.

숨쉬는 벽체를 적용한 건물에서의 실내공기질(IAQ) 개선 효과 분석 (IAQ improvement effect analysis in Dynamic Breathing Building(DBB))

  • 박용대;이진숙;강은철;이의준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.748-753
    • /
    • 2008
  • In modern buildings, the air-tightness and insulation for energy saving resulted in degradation of Indoor Air Quality(IAQ). It has brought out new diseases such as New Building Syndrome(NBS) and Sick Building Syndrome(SBS) to the tenants of such buildings. As a result, researches on the Dynamic Breathing Building(DBB) are being undertaken to minimize energy loss as well as to improve IAQ. DBB is a state-of-the-art technology to build channels inside the wall so that air migrates between indoor and outdoor, which improves insulation performance and IAQ. This study attempts to evaluate the improvement of DBB employed in real buildings. As analyzing tools, IAQ improvement and particle degradation while were evaluated while the required indoor ventilation rate was satisfied. DBB were installed in the twin test cells at Korea Institute of Energy Research(KIER). From the test, IAQ was compared with outdoor air base on the concentration of particle matter(PM10). As a results, the concentration of particle dust (PM10) within the breathing walls was reduced by 80% at 0.7 ACH, 67% at 2 ACH, 63% at 3 ACH respectively. As ACH is higher, Dnamic Isulation(DI) and normal wall permit more PM10 particles being infiltrated.

  • PDF

농어촌 주택 표준모델의 냉난방에너지요구량 분석 (Heating and Cooling Energy Demand Analysis of Standard Rural House Models)

  • 이찬규;김우태
    • 한국산학기술학회논문지
    • /
    • 제13권8호
    • /
    • pp.3307-3314
    • /
    • 2012
  • 농어촌 주택 표준모델에 대한 연간 건물에너지요구량을 DesignBuilder를 사용하여 계산하였다. 실내설정온도, 외벽의 열관류율, 창호타입, 환기량을 변화시키며 건물의 설계/운영 변수들이 에너지요구량에 미치는 영향을 분석하였다. 건물의 크기와 상관없이 난방에너지요구량이 냉방에너지요구량보다 더 큰 것으로 나타났다. 단열재 두께를 증가시켜 외벽의 열관류율을 감소시키면 단열효과의 증가로 난방에너지요구량은 감소하지만 냉방에너지요구량이 증가한다. 하지만 외벽의 열관류율 조절을 통한 난방에너지요구량의 절감에는 한계가 있으므로 외부에 직접 노출된 외벽의 면적을 최소화하는 것이 더 효과적인 것으로 판단된다. 계산에 사용된 4가지 창호 중 일반 이중창호가 난방에너지요구량 측면에서 가장 유리한 것으로 나타났다. 침기량은 일정하게 유지하고 단위시간당 환기량을 증가시킨 경우 냉방에너지요구량은 큰 변화가 없었으나 난방에너지요구량이 증가하였다. 실내의 공기질이 만족되는 범위 내에서 환기량을 최소화하는 것이 연간 건물에너지요구량을 줄이는데 유리한 것으로 판단된다.

기존 노후건축물의 최적 리모델링 개선안 연구 (Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds)

  • 김대원;정광섭;김영일;남아리새;오세민
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.207-216
    • /
    • 2014
  • 에너지손실을 분석해 보면 열전달에 의한 손실과 공기유동에 의한 손실로 구분할수 있다. 열전달은 외벽, 지붕, 바닥의 열관류율에 의한 손실로 기존건축물의 가장 취약한 부분의 한 요소이다. 이런 손실을 방지 하려면 창을 포함한 외벽 전체의 평균 열관류율을 지역 기준값 이상으로 올리고 창의 기밀성을 확보함에 따라 방지 할수 있다. 노후건축물의 가장 취약한 부분이 외벽과 창호 이지만 출입문을 통한 침기량은 연돌효과에 의해 층계단을 타고 올라감과 동시에 각층의 공기를 흡입하여 더큰 유동을 잃으켜 층의 단열성 까지 취약하게 만드는 구조로 되어 있다. 현장 조사를 통한 진단과 에너지 개선처방이 제시될 때 반드시 건물전체에 대한 진단과 각층 부분에 대한 개선안이 함께 제출되어 단순히 창 교체만 하면 에너지절감을 이룰수 있다는 착각에서 벗어나야 할 것이다.

황사 발생시 아파트 실내에서 미세먼지 크기별 농도 특성 (Characteristics of Indoor Particulate Matter Concentrations by Size at an Apartment House During Dusty-Day)

  • 주상우;지준호
    • 한국입자에어로졸학회지
    • /
    • 제15권1호
    • /
    • pp.37-44
    • /
    • 2019
  • 본 연구에서는 국내에서 가장 일반적인 유형의 주택으로서 3인 가구가 거주하는 공급면적 $117.69m^2$의 일반형 아파트를 측정 주택으로 선정하여 실증 측정을 진행하였다. 황사 발생이 포함된 3일 측정기간 동안 미세먼지 변화 특성을 관찰하여 분석하였다. 관측된 미세먼지($PM_{10}$)를 상대적으로 큰 먼지($PM_{10-2.5}$)와 초미세먼지($PM_{2.5}$)로 나누어 대기와 실내의 먼지의 농도변화를 분석하였다. 연구 결과로 재실자의 활동이 없는 외출이나 취침 기간에는 주택의 침기 특성을 확인할 수 있었다. 미세먼지 중 상대적으로 큰 $PM_{10-2.5}$ 크기 입자는 외기의 풍속이 5 m/s까지 증가하여 침기량이 증가해도 대기 농도 대비 실내 농도비가 7% 이하인 반면, $PM_{2.5}$의 경우 외기 속도가 5 m/s까지 증가하면 50% 이상으로 증가하였다. 황사가 심한 대기 상태에도 본 연구의 측정 주택의 경우 실내 $PM_{10-2.5}$는 시평균$15{\mu}g/m^3$로 대기 농도의 5% 수준으로 일상 조건과 비슷했다. 재실자의 활동이 있는 경우에는 미세먼지 중 초미세먼지를 제외한 상대적으로 큰 먼지는 자연환기와 실내 사람의 움직임과 같은 행동 영향이 지배적이었다. 실내 $PM_{10-2.5}$ 농도는 대기 농도가 낮은 경우에는 대기 농도의 약 50%를 차지하는 경우도 있었다. 재실자의 활동 중, 초미세먼지의 발생이 클 것으로 예상되는 굽기나 튀기기가 포함된 조리나 실내 흡연이 없었기 때문에, 재실자가 없는 경우와 마찬가지로 초미세먼지는 실내 농도가 실외 농도의 추이에 따라 함께 변동하는 양상을 보였다. 외부공기가 침기에 의해 창틈, 문틈으로 유입되는 과정에서 초미세먼지는 약 30~40% 정도가 제거되고 실내로 많은 비율이 유입되기 때문에 실외 초미세먼지의 실내에 대한 영향이 컸다. 본 연구의 분석 데이터는 측정이 이루어진 대표 주택에 해당하는 것으로, 새로 지어진 기밀 성능이 높은 신축 아파트나 침기가 상대적으로 클 것으로 예상되는 오래된 단독주택에서는 다른 특성이 나타날 것으로 예상되므로, 이에 대한 추가적인 연구가 필요하다고 생각된다.