A Study on the Calculation Method of Infiltration for Detached Houses  

Kim, Giltae (Environment Energy Research Group, Land and Housing Institute)
Yoo, Jung-Hyun (Environment Energy Research Group, Land and Housing Institute)
Hwang, Ha-Jin (Environment Energy Research Group, Land and Housing Institute)
Kim, Kyoung-Sik (Environment Energy Research Group, Land and Housing Institute)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.25, no.9, 2013 , pp. 493-498 More about this Journal
Abstract
The purpose of this study is to find the infiltration of detached houses, for energy consumption analyses. The pressurization and depressurization method is used to determine infiltration. Blower door tests are expressed in terms of ACH 50, which stands for the hourly air change rate at 50 Pa of fan pressure. The ACH 50 of existing Detached Houses ranges from 5 to 50. Air infiltration is related to construction year and accuracy, maintenance conditions, and so on. When estimating the infiltration of random detached houses, the year used can be the base value of the infiltration rate from 0.25 to 2.0 times/h. The maintenance conditions, construction accuracy and repair affect the air infiltration 0 to 0.5 times/h, 0 to 0.3 times/h, 0 to 1 times/h, respectively.
Keywords
Infiltration; Airtightness; Detached houses; Energy performance;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Statistics Korea, 2010, Census.
2 Kwon, O. H., Kim, J. H., Kim, M. H., Seok, Y. J., and Jeong, J. W., 2010, Case Study of Residential Building Air Tightness in Korea based on Blower Door Test Approach, Journal of the Architectural Institute of Korea, Vol. 26, No. 7, pp. 303-310.   과학기술학회마을
3 Jo, J. H., 2010, Measurements of the Dwelling Unit Airtightness in High-rise Residential Buildings, Journal of the Architectural Institute of Korea, Vol. 26, No. 10, pp. 337-344.   과학기술학회마을
4 Blowerdoor System User's Guide.
5 Alan, Mier, 1994, Infitration : Just ACH50 Divided by 20?, Home Energy Magazine.
6 Yoon, J. h., Park, J. W., Lee, K. S., Baek, N. C., and Shin, U. C., 2008, A study on the measurement of airtightness performance detached houses in chung-cheong area, Journal of the Koran Solar Energy Society, Vol. 28, No. 5, pp. 65-77.   과학기술학회마을