• Title/Summary/Keyword: 치료율 모형

Search Result 48, Processing Time 0.03 seconds

RELAPSE AND STABILITY : AN EVALUATION OF CLASS I MALOCCLUSION NONEXTRACTION THERAPY (비발치로 치료한 제1급 부정교합자의 재귀현상에 관한 연구)

  • Kim, Gu-Soon;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.79-89
    • /
    • 1997
  • One of the strenuous problems in orthodontic procedures is postretention stability and retention against relapse. Many investigative trial had been done to disclose the factors associated with relapse and effective prescription to stave off, however, the nature of these jeopardies remained obscure. The objective was to investigate the long-term stability and quantitative changes of dental arches subsequently after Class I nonextraction treatment. Study models,cephalometric headfilms of 26 samples which were taken before, after teatment and postretention were employed to measure the interdental width of corresponding buccal teeth,overbite,overjet and the inclination of incisors and molars. Statistical analysis was carried to compare each measurements across the time period, and followings were brought around. 1. The quantitative amount of relapse in overbite presented positive correlation with the amount of changes through the treatment. 2. Stability of intercanine width was so far secure in the case the expansion had been done through. 3. The amount of changes in intercanine width of the lower regardless of expansion or contraction manifested less than the upper, however, the relapse ratio got high. 4. The upper and lower incisors were likely to be labioversive, and remained stable after retention. 5. The first molars of the upper and lower were conceivably tipped back immediately after treatment and returned to the original angulation. The expansion of intermolar width stayed stable across the time scheme after treatment It was suggested that the maintenance of intercanine width of lower was pertinent to perform the postretention stabilityv and the expansion of dental arch shoed be confined within physiologic boundaries of the patients.

  • PDF

A Study on Superficial Dose of 6MV-FFF in HalcyonTM LINAC: Phantom Study (HalcyonTM 선형가속기 6MV-FFF 에너지의 표재 선량에 대한 고찰: Phantom Study)

  • Choi, Seong Hoon;Um, Ki Cheon;Yoo, Soon Mi;Park, Je Wan;Song, Heung Kwon;Yoon, In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.31-39
    • /
    • 2020
  • Purpose: The aims of this study were to compare the superficial dose with Optically Stimulated Luminescence Dosimeter(OSLD) measurement and Treatment Planning System(TPS) calculation for 6MV-Flattening Filter Free(FFF) energy using HalcyonTM and TrueBeamTM. Materials and methods: Phantom study was performed using the CT images of human phantom. In the treatment planning system, the Planning Target Volume(PTV) was contoured which is similar to Glottic cancer. Furthermore, Point(M), Point(R), and Point(L) were contoured at the iso-center of head and neck region and 5mm bolus was applied to the body contour. Each treatment plans using 6MV-FFF energy from HalcyonTM and TrueBeamTM with static Intensity Modulated Radiation Therapy(IMRT) and Volumetric Modulated Arc Therapy(VMAT) were established with eclipse. To reproduce the same position as the TPS, OSLDs were placed at the iso-center point and 5mm bolus was applied to compare the error rate after the dose delivery. Result: The results of the study using human phantom are as follows. In case of HalcyonTM, the mean absolute error rates of the point dose using the treatment planning system and the dose measured by OSLD were 1.7%±1.2% for VMAT and 4.0±2.8% for IMRT. Also TrueBeamTM was identified as 2.4±0.4% and 8.6±1.8% respectively for VMAT and IMRT. Conclusion: Through the results of this study, TrueBeamTM confirmed that the average error rate was 2.4 times higher for VMAT and 3.6 times higher for IMRT than HalcyonTM. Therefore, based on the results of this study, If we need a more accurate dose assessment for the superficial dose, It is expected that using HalcyonTM would be better than TrueBeamTM.

Analysis of stage III stomach cancer using the restricted mean survival time (제한된 평균 생존시간을 이용한 위암 3기 자료 분석에 관한 연구)

  • Kim, Bitna;Lee, Minjung
    • The Korean Journal of Applied Statistics
    • /
    • v.34 no.2
    • /
    • pp.255-266
    • /
    • 2021
  • The purpose of this study is to compare the effects of treatment on stage III stomach cancer data obtained from the SEER program of the National Cancer Institute and to identify the significant risk factors for the survival rates of stage III stomach cancer. Since the proportional hazards assumption was violated for treatment, we used the restricted mean survival time as an alternative to the proportional hazards model. The restricted mean survival time was estimated using pseudo-observations, and the effects of treatment were compared using a test statistic based on the estimated restricted mean survival times. We conducted the regression analysis using a generalized linear model to investigate the significant predictors for the restricted mean survival time of patients with stage III stomach cancer. We found that there was a significant difference between the restricted mean survival times of treatment groups. Age at diagnosis, race, substage, grade, tumor size, surgery, and treatment were significant predictors for the restricted mean survival time of patients with stage III stomach cancer. Surgery was the most significant predictor for increasing the restricted mean survival time of patients with stage III stomach cancer.

Modeling Clustered Interval-Censored Failure Time Data with Informative Cluster Size (군집의 크기가 생존시간에 영향을 미치는 군집 구간중도절단된 자료에 대한 준모수적 모형)

  • Kim, Jinheum;Kim, Youn Nam
    • The Korean Journal of Applied Statistics
    • /
    • v.27 no.2
    • /
    • pp.331-343
    • /
    • 2014
  • We propose two estimating procedures to analyze clustered interval-censored data with an informative cluster size based on a marginal model and investigate their asymptotic properties. One is an extension of Cong et al. (2007) to interval-censored data and the other uses the within-cluster resampling method proposed by Hoffman et al. (2001). Simulation results imply that the proposed estimators have a better performance in terms of bias and coverage rate of true value than an estimator with no adjustment of informative cluster size when the cluster size is related with survival time. Finally, they are applied to lymphatic filariasis data adopted from Williamson et al. (2008).

Therapeutic Compliance for Calcium Supplements and Its Related Factors in Rural Osteoporotic Women (일부 농촌지역 여성 골다공증 환자의 칼슘보조제 치료순응도와 결정요인)

  • Chun, Byung-Yeol;Kam, Sin;Lee, Young-Ja;Lee, Sang-Won;Lee, Kyung-Eun;Lee, Young-Seok;Kim, Bong-Kee
    • Journal of agricultural medicine and community health
    • /
    • v.26 no.2
    • /
    • pp.111-132
    • /
    • 2001
  • This study was conducted to examine the therapeutic compliance and its related factors in rural women with osteoporosis. A questionnaire survey was performed from April to May in 2000 for 140 osteoporotic patients who were diagnosed from April to June in 1999 through community health program. The study employed the health belief model for predicting and explaining sick role behavior. The analysis techniques employed included contingency table analysis and path analysis using LISREL. The major results of this study were as follows: Of the subjects, 12.1% were continuously complaint, 53.6% were intermittently compliant, and 34.3% were non- compliant to calcium supplement therapy. As the result of path analysis, the therapeutic compliance was significantly higher(${\mid}T{\mid}$ >2.0) as patients had higher perceived severity of disease, lower perceived barriers of treatment, and when patients thought their disease status as severe. As the patients had higher educational level, more experience of mass media contact or health education about osteoporosis, and when family had more concern for patient treatment, they had higher perceived susceptibility of complication(bone fracture)${\mid}T{\mid}$ >2.0). The patients had higher perceived severity(${\mid}T{\mid}$ >2.0) as they had more educational level, more advice for treatment from their doctors, and when family had more concern for their treatment. As the patients had more advice for treatment from their doctors and when family had more concern for their treatment, they had higher perceived benefit of treatment and lower perceived barriers to treatment(${\mid}T{\mid}$ >2.0). In order to improve the therapeutic compliance in rural osteoporotic women, it would be necessary that the patient should recognize their disease severity properly. And the perceived barriers should be removed through supportive environments for osteoporosis treatment such as doctor 's more advice and family 's more concern for treatment. In addition, effective and continuous management system for osteoporotic patients should be established.

  • PDF

Optimization of Dose Distribution for High Dose Rate Intraluminal Therapy (고선량율 관내 방사선치료를 위한 종양선량분포의 최적화에 대한 연구)

  • Chu, Sung-Sil;Kim, Gwi-Eon;Loh, Juhn-Kyu
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.243-252
    • /
    • 1994
  • The use of high dose rate remote afterloading system for the treatment of intraluminal lesions necessitates the need for a more accurate of dose distributions around the high intensity brachytherapy sources, doses are often prescribed to a distance of few centimeters from the linear source, and in this range the dose distribution is very difficult to assess. Accurated and optimized dose calculation with stable numerical algorithms by PC level computer was required to treatment intraluminal lesions by high dose rate brachytherapy system. The exposure rate from sources was calculated with Sievert integral and dose rate in tissue was calculated with Meisberger equation, An algorithm for generating a treatment plan with optimized dose distribution was developed for high dose rate intraluminal radiotherapy. The treatment volume becomes the locus of the constrained target surface points that is the specified radial distance from the source dwelling positions. The treatment target volume may be alternately outlined on an x-ray film of the implant dummy sources. The routine used a linear programming formulism to compute which dwell time at each position to irradiate the constrained dose rate at the target surface points while minimizing the total volume integrated dose to the patient. The exposure rate and the dose distribution to be confirmed the result of calculation with algorithm were measured with film dosimetry, TLD and small size ion chambers.

  • PDF

The Usability Analysis of 3D-CRT, IMRT, Tomotherpy Radiation Therapy on Nasopharyngeal Cancer (NPC의 방사선치료시 3D-CRT, IMRT, Tomotherapy의 유용성 분석)

  • Song, Jong-Nam;Kim, Young-Jae;Hong, Seung-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.365-371
    • /
    • 2012
  • The radiation therapy treatment technique is developed from 3D-CRT, IMRT to Tomotherapy. and these three technique was most widely using methods. We find out a comparison normal tissue doses and tumor dose of 3D-CRT, IMRT(Linac Based), and Tomotherapy on Head and Neck Cancer. We achieved radiological image used the Human model phantom (Anthropomorphic Phantom) and it was taken CT simulation (Slice Thickness : 3mm) and GTV was nasopharngeal region and PTV(including set-up margin) was GTV plus 2mm area. and transfer those images to the radiation planning system (3D-CRT - ADAC-Pinnacle3, Tomotherapy - Tomotherapy Hi-Art System). The prescription dose was 7020 cGy and measuring PTV's dose and nomal tissue (parotid gland, oral cavity, spinal cord). The PTV's doses was Tomotherapy, Linac Based - IMRT, 3D-CRT was 6923 cGy, 6901 cGy and 6718 cGy its dose value was meet TCP because its value was up to the 95% based on 7020 cGy, Nomal tissue (parotid gland, oral cavity, spinal cord) was 1966 cGy(Tomotherapy), 2405 cGy(IMRT), 2468 cGy(3D-CRT)[parotid gland], 2991 cGy(Tomotherapy), 3062 cGy(IMRT), 3684 cGy (3D-CRT)[oral cavity], 1768 cGy(Tomotherapy), 2151 cGy(IMRT), 4031 cGy(3D-CRT)[spinal cord] its value did not exceeded NTCP. All the treatment techniques are equated with tumor and nomal tissue doses. The 3D-CRT was worse than other techniques on dose distribution, but it is reasonable in terms of TCP and NTCP baseline Tomotherapy, IMRT -dose distribution was relatively superior- was hard to therapy to claustrophobic patients and patients with respiratory failure. Particularly, in case on Tomotherapy, it take MVCT before treatment so dose measurement will be unnecessary radiation exposure to patients. Conclusion, Tomotherapy was the best treatment technique and 2nd was IMRT, and 3rd 3D-CRT. But applicable differently depending on the the patient's condition even though dose not matter.

Evaluation of Electron Beam Dose Distribution by Age Diffusion Equation (연령 확산 이론에 의한 전자선의 조직내 선량분포 평가)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.4 no.1
    • /
    • pp.29-39
    • /
    • 1993
  • Electron beams have found unique and complementary used in the treatment of cancer, but it's very difficult to delineate dose distribution, because of multi-collisions. Numerical solution is more usefull to describe electron distributed in tissue. A semi-empirical eqution is given for the dose at any point at various depths in water. This equation is a modificated model which was based on solutions of a general age diffusion equation. Parameters have been calulated from electron beams data with energies 6~18MeV form a LINAC for use in computerised dosimetry calculations. The depth doses and isodose curves are predicted as a function of the practical range, source skin distance and field size. Depth dose accuracy have been achieved 2% above 50% depth dose and 5% at lower doses, relative to maximum dose. Also, the shape of the isodose curves with the constrictions at higher dose and bulging ot lower values are accurately predicted. Computer calculated beams have been used to generate ever isodose distribution for certain clinical situations.

  • PDF

Therapeutic compliance and its related factors in pediatrics patients (소아 환자의 치료 순응도 및 이에 영향을 미치는 요인)

  • Park, Ki Soo;Kam, Sin;Kim, Heung Sik;Lee, Jeong Kwon;Hwang, Jin-Bok
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.6
    • /
    • pp.584-596
    • /
    • 2008
  • Purpose : This study was conducted to investigate treatment compliance and related factors in pediatric patients. Methods : Three hundred and fifty-five patients diagnosed with various acute diseases at a teaching hospital or clinic in October 2003 were enrolled. Data were analyzed using the Health Belief Model, which includes items on self-efficacy and family assistance. Results : The study found that 62.9% of pediatric patients adhered faithfully to agreed-upon hospital revisits, 41.6% complied with dose timings instructions, 65.8% precisely took medication, and 27.2% complied with all of these requirements. According to ${\chi}^2$ test analysis, the factors found to be related to therapeutic compliance (the taking of medicines requested) were; susceptibility, severity, benefit, barriers, mother's self-efficacy, and family assistance (P<.05). Multiple logistic analysis and path analysis showed that susceptibility, severity, barriers, and mother's self-efficacy were related to therapeutic compliance (P<.05). Moreover, mother's self-efficacy was identified as the most important factor. Conclusion : To improve therapeutic compliance among pediatric patients, parental education is necessary, and a health care professional must take a thorough history of how the medication was taken before it is assumed that treatment failure is attributable to the medication prescribed. Furthermore, the type of device recommended for dosing should be determined by clinicians. In addition, it is important that pediatric medications be discussed in relation to their palatability and internal acceptability.

Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors (악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료)

  • Kwon, Da Eun;Hwang, Ji Hye;Park, In Seo;Yang, Jun Cheol;Kim, Su Jin;You, Ah Young;Won, Young Jinn;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Helmet type bolus for 3D printer is being manufactured because of the disadvantages of Bolus materials when photon beam is used for the treatment of scalp malignancy. However, PLA, which is a used material, has a higher density than a tissue equivalent material and inconveniences occur when the patient wears PLA. In this study, we try to treat malignant scalp tumors by using M3 wax helmet with 3D printer. Methods and materials: For the modeling of the helmet type M3 wax, the head phantom was photographed by CT, which was acquired with a DICOM file. The part for helmet on the scalp was made with Helmet contour. The M3 Wax helmet was made by dissolving paraffin wax, mixing magnesium oxide and calcium carbonate, solidifying it in a PLA 3D helmet, and then eliminated PLA 3D Helmet of the surface. The treatment plan was based on Intensity-Modulated Radiation Therapy (IMRT) of 10 Portals, and the therapeutic dose was 200 cGy, using Analytical Anisotropic Algorithm (AAA) of Eclipse. Then, the dose was verified by using EBT3 film and Mosfet (Metal Oxide Semiconductor Field Effect Transistor: USA), and the IMRT plan was measured 3 times in 3 parts by reproducing the phantom of the head human model under the same condition with the CT simulation room. Results: The Hounsfield unit (HU) of the bolus measured by CT was $52{\pm}37.1$. The dose of TPS was 186.6 cGy, 193.2 cGy and 190.6 cGy at the M3 Wax bolus measurement points of A, B and C, and the dose measured three times at Mostet was $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$ and $195.33{\pm}1.69cGy$. And the error rates were -3.71 %, -4.59 %, and 2.48 %. The dose measured with EBT3 film was $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$ and $196{\pm}2.16cGy$. The error rates were -2.46 %, 0.23 % and 2.83 %. Conclusions: The thickness of the M3 wax bolus was 2 cm, which could help the treatment plan to be established by easily lowering the dose of the brain part. The maximum error rate of the scalp surface dose was measured within 5 % and generally within 3 %, even in the A, B, C measurements of dosimeters of EBT3 film and Mosfet in the treatment dose verification. The making period of M3 wax bolus is shorter, cheaper than that of 3D printer, can be reused and is very useful for the treatment of scalp malignancies as human tissue equivalent material. Therefore, we think that the use of casting type M3 wax bolus, which will complement the making period and cost of high capacity Bolus and Compensator in 3D printer, will increase later.