• Title/Summary/Keyword: 치과의료장비

Search Result 32, Processing Time 0.026 seconds

The Effect of the Medical Service by Service Instruction of Dental Health Care Worker (치과 의료 종사자의 의료 서비스 교육이 의료 서비스에 미치는 영향)

  • Kim, Chang-Hee;Lee, Ji-Youn;Lee, Hyun-Ook
    • Journal of dental hygiene science
    • /
    • v.1 no.1
    • /
    • pp.53-59
    • /
    • 2001
  • This study was aimed to survey the level of service education in the people engaging in medical services and identify the influence of the education on their job performance. This study was conducted from February 10th, 2000 to March 10th, 2000, centering on Seoul and Kyonggi area. A total of 341 questionnaires were distributed for the survey. The result ware as followings: (1) In a question about the satisfaction over general medical services such as the location of medical institutions, medical equipments and devices, and the attitudes of medical personnel, the group with service education marked 4.07 while the group with no education earned 3.97, showing statistically significant difference(p<.05). (2) In the area of medical institutions image, level of medical services and promotion, the group with service education showed 4.01 while the group with no education gained 3.83, also showing statistically significant difference(p<.05). (3) No statistically meaningful difference was revealed in the area of satisfaction for over all medical services such as the contentment about the medical services being provided, rooms for improvement and the adequacy of the number of medical personnel. The group with education acquired 3.32, with the group with no education 3.34. (4) Satisfaction about the education and awareness about medical services were high in the group of dental hygienists and showed a statistically meaningful difference. (5) The average number of education recorded 1.83 and satisfaction over service education inside the hospital was low, registering 3.24. (6) Teamwork among the personnel in the hospital was 3.70, which is relatively high. The fulfillment over given tasks posted 3.56 and the recommendation for medical institutions was low, recording 3.24. (7) The necessity of medical service education for medical personnel gained 4.40, indicating heightened awareness over the need for service education.

  • PDF

Design of Microprocessor-Based Measuring Instrument for the Silent Period of Masseter Muscle (마이크로프로세서에 의한 교근의 휴지기 측정장치의 설계)

  • Han, Hyeon-Bae;Ro, Seung-Yong;Kim, Seong-Hwan
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.2
    • /
    • pp.55-59
    • /
    • 1985
  • The measurement of the silent period of Masseter muscle is very useful diagnostic method of TMJ syndrome. In this paper, we design a very convenient and very low-priced medical instrument for dental research which does not need gain control to each patient for measuring the silent period and the data processing time is very short. The result of SP measurement using this instrument is 20-30ms in normal subjects and about 60ms in TMJ patient, and the data processing time is 0.5 second.

  • PDF

The Noise Characteristics and Appropriate Talk Distance in Dental Clinic (치과병원의 소음특성과 적절한 대화거리)

  • Ji, Dong-Ha;Choi, Mi-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2516-2523
    • /
    • 2013
  • Noise occurred when medical treatment in dental clinic will affect the patients. This study was measured the noise level and frequency in case of medical examination and also has evaluated the degree of indoor noise using the NR-curve, NRN and a distance to conversation between worker and patients using the PSIL. It shows that noise level was 69.3~81.5dB(A) and frequency was very high (more than 4K(Hz)) and analysis by NR-curve showed that it was exceed the noise permit level and distance to conversation was less than 1meter by PSIL. To remedy a fear of noise in patients and provide a conversational satisfaction, it's considered that choosing the low noise-vib. equipment, using the masking effect and set the room to explain. So It is possible to improve their competitiveness.

Characteristics of Noise Radiated at Dental Clinic (치과병원에서 치료시 발생하는 소음특성)

  • Ji, Dong-Ha;Choi, Mi-Suk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.12
    • /
    • pp.1123-1128
    • /
    • 2009
  • Noise radiated from medical treatment at dental clinic will affect the patients. On such point of view, We investigated the noise characteristics in case of medical treatment (scaling, tooth eliminating) and non-medical examination (idling) and also evaluated the degree of indoor noise using the evaluation index such as PSIL, NRN and made up a questionnaire about the reactions to noise. As a result of noise evaluation, it shows that the range of noise level is 67.7~78.3 dB(A) and frequency is very high (above 4 k Hz) and respondents are affected by noise (unpleasantness, hesitation to visit dental clinic, shivering with noise, being astonishment). Analysis by PSIL showed that it was no problem to conversation between worker and patient. But it exceeded the noise permit level in working space by NR-curve. To relieve a fear of noise in patients, they are considered to offer the ear protection, choose the low noisevibration equipment and use the masking effect. They are of great advantage to dental clinics to i prove dental service and competitiveness.

Design & Manufacturing of Surgical Telescope with 3.5 times magnification. (배율 3.5X 의료용 망원경의 설계 및 제작)

  • 이호찬;김재순;이재형;이하덕
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.112-113
    • /
    • 2003
  • 일반, 혹은 신경외과 의사가 작은 수술부위의 구멍을 통해 미세한 혈관수술 등을 할 때, 혹은 치과의사가 환자의 입을 통해서 입 속을 치료할 때, 수술 혹은 치료를 하는 대상의 크기는 굵은 혈관의 경우 지름이 30~40$\mu\textrm{m}$, 치아 속 신경의 역시 굵은 경우에 2.8$\mu$m 에 지나지 않는다. 그러나 일반적인 눈의 분해능은 1분인데, 이는 40cm의 거리에 있는 0.06mm 크기의 물체(9lp/mm)를 구분하는 능력이다. 특별한 광학장비 없이 물체에 가까이 감으로써 시력을 향상시킬 수는 있지만 단순히 가까이 다가가는 것만으로는 수술과 같은 섬세한 임상작업을 하는데는 제한이 많고, 특히 작은 구멍이나 좁은 관을 통해 가까운 물체를 볼 때는 양안 시차의 불일치(stereofocusing) 문제가 발생한다. (중략)

  • PDF

Health Medical Center Utilization Pattern and Its Related Factors among the Rural Inhabitants (농촌지역(農村地域) 주민(住民)들의 보건의료원(保健醫療院) 이용양상(利用樣相)과 관련요인(關聯要因))

  • Hwang, Byung-Deog;Park, Jae-Yong
    • Journal of agricultural medicine and community health
    • /
    • v.18 no.1
    • /
    • pp.77-91
    • /
    • 1993
  • This study was conducted to assess health medical center utilization pattern and its related factors among the rural inhabitants for the purpose of contribution to establishment of health medical center institutions. A questionnaire survey was carried out for object of 3,754 population of three primary school and three middle school student's parents (total 832 household) in Kyungbook Ulchin Gun rural area from 24 to 28 September, 1990. The summarized result are as follows, Respondents are 60.3% in male, 39.7% in female and 30-40s 81.3% in age, high school graduates 40.3% in education level and a regional medical insurance scheme in 44.1% in forms of health insurance. Recognition for health medical center was showed higher according to high educational, high income level, and short distance for location of health medical center of respondents (p < 0.01). Recognition for health medical center services was showed higher about care of medicaid in medical treatment services and higher preventive vaccination in health prevention services by respondents. Utilization rates of health medical center by out-patient care and preventive care service were 11.1 and 4.5 per 100 persons by year, but admission utilization rate was 34.6 per 10.000 persons by year. Motivations of health medical center utilization were showed a good care(45.7%), a good drugs(45.2%), and nearby health medical center(42.9%). In comparison health service levels of health medical center with general clinic was better (16.3%), similar(38.7%), 7(19.0%), and worse(19.0%) in view of health medical center utilizators. Inconvinience about health medical center utilized was the most higher longtime waiting, the next was limited utilization times. Transportation utilited were on foot(55%), by bus(35.5%), and so on. As mentioned above, there are many inhabitants who less understanding and less acknowledgement about health medical center and even mistake health center for health medical center. Therefore, there must be more information about health medical center. For higher utilization of health medical center, there must be considered expansion of health equipment, facilities, accomplishment with reinforcement of health staffs and efficiency management.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

A Study on the Dental Hygienists' Reactions to Noise When Occurred in Dental Clinic (치과병원에서 발생하는 소음에 대한 치과위생사의 반응)

  • Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of dental hygiene science
    • /
    • v.9 no.4
    • /
    • pp.453-459
    • /
    • 2009
  • The purposes of this research were to evaluate the relationships of between characteristics of noise and annoyance of dental hygienist by noise in dental clinic. To investigate the dental clinic workers' reactions to noise when occurred in dental clinic, the noise level test in dental clinic and questionnaire were taken. As a result of noise evaluation, It shows that the range of noise level was 67.7~78.3dB(A) and frequency was very high (more than 4KHz). It's seem to be begins occurrence of stamina-loss, contraction of peripheral blood vessel, decrease of adrenocortical hormones. Most of respondents were affected by noise: 67% of respondents were nervous about noise and the rest of respondents were bearable. Analysis by NR-curve showed that it was exceed the noise permit level in working space. As a result of correlation - test, the more exposed dental hygienist to noise, the more felt the unpleasantness and fatigue. It's hard to sufficient explanation to patients about the dental treatment. So it's thoughts that insufficient explanation will negative impact on the patients' satisfaction and increase competitiveness in dental clinics. To remedy a unpleasantness and fatigue of noise in dental hygienist, it's considered that making an offer the ear protection and choosing the low noise-vib. equipment and using the masking effect. Therefore, It can be provide a pleasant working environment with dental hygienist and It will have a great advantage to dental clinics to improve their competitiveness.

  • PDF

A COMPARATIVE STUDY ON THE THEMATIC DISTRIBUTION OF THE ARTICLES PUBLISHED IN THE JOURNAL OF THE AMERICAN ACADEMY OF PEDIATRIC DENTISTRY AND THE JAPANESE SOCIETY OF PEDIATRIC DENTISTRY (90년대 이후 미국과 일본 소아치과학회지 게재논문의 분야별 분포에 관한 비교 연구)

  • Yeom, Junng-Hyun;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.539-554
    • /
    • 2002
  • To identify the trend of pediatric dentistry in USA and Japan, closely related to Korean pediatric dentistry. The Japanese Journal of Pediatric Dentistry(JJPD) and The Journal of the American Academy of Pediatric Dentistry(PD) were reviewed. We collected the bibliographical data of the articles published in the two journals from 1991 to 2000. We analyzed thematic distributions and chronological changes, and then compare those of two groups. The following results were obtained: 1. The 869 articles were published in JJPD and 672 in PD. This was about 30% more in JJPD. 2. In both JJPD and PD, the case reports were a quarter of scientific articles in quantity. 3. The studies on the systemic diseases had the highest proportion in both JJPD and PD. The studies on the dental caries and restorative materials also had high proportion in both journals. 4. The studies on the sedation and biochemical survey had high proportion in PD when had low proportion in JJPD. To the contrary, The studies on the behavior science in JJPD were about double of those in PD. 5. There was no statistically significant difference in quantity between JJPD and PD in the studies on the dental caries, prevention of dental caries, community dental survey, conservative treatment, restorative materials, pulp treatment, diagnosis and treatment of malocclusion, oral pathology and minor surgery, local anesthesia and nerve tissue, traumatic injuries. 6. There was statistically significant increase in the studies on the dental equipment in JJPD and in those on restorative materials in PD. 7. There was statistically significant decrease in the studies on the prevention of dental caries and local anesthesia and nerve tissue in JJPD, and those on conservative treatment in PD.

  • PDF

Evaluation of Effective Dose in Dental Radiography (치과 방사선 검사에서 유효선량 평가)

  • Han, Su-Chul;Lee, Bo-Ram;Shin, Gwi-Soon;Choi, Jong-Hak;Park, Hyok;Park, Chang-Seo;Chang, Kye-Yong;Kim, Bo-Ram;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.27-33
    • /
    • 2011
  • Along with the developments of science technology, up-to-date medical radiation equipments are introduced. Those equipments has brought many progresses in diagnosing patients not only in the quantitative aspects but in the qualitative ones. Especially, in the case of dental radiography, patients can be exposed more than CT, cone beam computed tomography (CBCT). In this study, we used human phantom and TLD-100H to measure the organ dose in each dental radiography and computed the effective dose according to ICRP (International Committee for Radioactivity Prevention) 60, 103. We measured the effective dose to be 5.1 and $29.5{\mu}Sv$ in the panoramic radiography and 11.2 and $14.4{\mu}Sv$ in the cephalometric radiography respectively. We also executed the CBCT and CT test on the maxillaries and the mandibles and found the amounts of effective dose were 53.7, 209.6, 129, and $391.5{\mu}Sv$ respectively in the CBCT and $93.3{\mu}$, 139.5, 282.7 and $489.7{\mu}Sv$ in the CT test. Consequently, it was shown that the effective dose in the CBCT test was lower than one in the CT test, but was higher in both panoramic and cephalometric radiography.