• Title/Summary/Keyword: 치과용 시멘트

Search Result 100, Processing Time 0.031 seconds

AN EXPERIMENTAL STUDY OF THE EFFECT OF TEMPORARY CEMENTS ON THE BOND STRENGTH OF PERMANENT CEMENTS (치과용 임시합착 시멘트가 영구합착 시멘트의 결합력에 미치는 영향에 관한 실험적 연구)

  • Lee, Jin-Ho;Lee, Ho-Yong;Han, Dong-Hoo
    • The Journal of the Korean dental association
    • /
    • v.22 no.9 s.184
    • /
    • pp.803-811
    • /
    • 1984
  • The purpose of this study was to research how temporary cementation effected on the bond strength of permanent cementation. Zinc phosphate, polycarboxylate and EBA ZOE cements were used as permanent cements, and as temporary cements Nogenol, Tempak and Dycal were used. The ninety six (96) specimens were prepared to measure the bond strength of permanent cements after treated with temporary cements for one week. The tensile stregths were measured with an Instron Universal Test Machine. The results of this study were obtained as follows: 1. With zinc phosphate cement, there was a tendency that the bond strengths of the group of temporarily cemented with Nogenol were increased, meanwhile they were decreased a little in the groups of Dycal and Tempak than those of the control group. 2. With polycarboxylate cement, there was a tendency that the bond strengths of the Control group were higher than those of experimental groups and they were decreased in order of Tempak, Noginol, and Dycal. 3. With EBA ZOE cement, there was a tendency that the bond strengths of the group of temporarily cemented with Tempak were increased a little, meanwhile they were decreased a little in the groups of Nogenol and Dycal than those of the Control group. 4. Among the permanent cements, the bond strengths of polycarbosylate cement were the highest and were followed in order of zinc phosphate cement and EBA ZOE cement.

  • PDF

THE EFFECTS OF CRYSTAL GROWTH ON SHEAR BOND STRENGTH OF ORTHODONTIC BRACKET ADHESIVES TO ENAMEL SURFACE (Crystal growth에 의한 법랑질 표면처리가 교정용 브라켓 접착제의 전단결합강도에 미치는 영향)

  • Lee, Young-Jun;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.839-852
    • /
    • 1997
  • It has been submitted that different ion solutions containing sulfate induce crystal growth and might substitute conventional acid etching for pretreatment of enamel in orthodontic bonding(${\AA}rtun$ et al., Am. J. Orthod. 85, 333, 1984). This investigation was designed to evaluate the relevance of crystal growth on the enamel surface as an alternative to conventional acid etching in direct bonding of orthodontic brackets. Annexing Li2SO4, MgSO4, K2SO4 respectively in the solution with $25\%$ polyacrylic md 0.3M sulfuric acids were employed to enhance the crystal growth. Human bicuspids were treated with various parameters as combinations of crystal growth and glass ionomer cement, crystal growth and orthodontic resin, acid etching and orthodontic resin for an investigative purpose. Crystal growth solution containing MgSO4 showed the highest shear bond strength(15.6MPa) within the groups of bonding brackets with glass ionomer cement(p<0.01). Bonding with glass ionomer cement on the surface of crystal growth demonstrated higher shear bond strength than with orthodontic resin(p<0.001). Bonding with glass ionomer cement on the surface treated with crystal growth solution containing MgSO4 or K2SO4 was not different shear bond strength statistically from bonding with orthodontic resin on the acid-etched surface. It suggests that bonding brackets with glass ionomer cement on the surface treated with crystal growth solution containing MgSO4 or K2SO4 is a potential alternative to bonding with resin on the acid etched sufrace.

  • PDF

Comparative study on the radiopacity of different resin-based implant cements (레진계 임플란트용 시멘트의 방사선 불투과성에 대한 비교연구)

  • Han, Kyeong-Hwan;Cheon, Ho-Young;Kim, Min-Su;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.97-104
    • /
    • 2014
  • This study was aimed to compare the radiopacity of four kinds of currently available resin based implant cements using digital radiography. Materials and Methods: Four resin-based implant cements((Estemp $Implant^{TM}$ (Spident, Incheon, Korea), $Premier^{(R)}$Implant (Premier, Pennsylvania, USA), $Cem-Implant^{TM}$ (B.J.M lab, Or-yehuda, Israel), $InterCem^{TM}$ (SCI-PHARM, California, USA)) and control group (Elite Cement $100^{TM}$ (GC, Tokyo, Japan) ) were mixed and cured according to the manufacturer's instructions on the custom made split-type metal mold. A total of 150 specimens of each cement were prepared and each specimen (purity over 99%) was placed side-by-side with an aluminum step wedge for image taking with Intraoral X-ray unit (Esx, Vatech, Korea) and digital X-ray sensor (EzSensor, Vatech, Korea). For the evaluation of aluminum wedge equivalent thickness (mm Al), ImageJ 1.47 m (Wayne Rasband, National Institutes of Health, USA) and Color inspector 3D ver 2.0 (Interaktive Visualisierung von Farbraumen, Berlin, Germany) programs were used. Result: Among the 5 cements, Elite cement $100^{TM}$ (control group) showed the highest radio-opacity in all thickness. In the experimental group, $InterCem^{TM}$ had the highest radio-opacity followed by $Premier^{(R)}$ Implant $Cement^{TM}$, $Cem-Implant^{TM}$ and Estemp $Implant^{TM}$. In addition, $InterCem^{TM}$ showed radio-opacity that met the ISO No. 4049 standard in all the tested specimen thickness. Cem-Implant on 0.5 mm thickness showed radiopacity that met the ISO No. 4049 standard. Conclusion: Among the implant resin-based cements tested in the study, $Premier^{(R)}$ Implant Cement and Estemp $Implant^{TM}$ did not show appropriate radio-opacity. Only $InterCem^{TM}$ and $Cem-Implant^{TM}$ 0.5 mm specimen had the proper radiopacity and met the experiment standard.

3-D FEA of three different single tooth abutments : Cement-retained Vs Screw-retained (3종의 단일치아 수복용 지대주의 삼차원 유한요소법적연구 : 시멘트 유지헝 대 나사 유지형)

  • Lee, Jung-Min;Kim, Yung-Soo;Kim, Chang-Whe;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.269-288
    • /
    • 1999
  • 현재 골 유착성 임플랜트는 안전하고 유용한 보철 수복 분야의 하나로 자리잡아 가고있다. 과거 완전 무치악 환자에게 있어서 저작 기능의 회복이란 면에 중점을 두었던 경향에서 현재 골유착 임플랜트의 높은 성공률에 의해 부문 무치악, 단일치 수복에 까지 다양하게 사용되고 있다. 특히 심미성과 인접치의 손상을 가하지 않는다는 면에서 단일치 수복에서 골유착 임플랜트 치료에 관심이 모아지고 있다. 단일치 수복에 있어서 심미성이 중요한 문제로 대두되면서 이런 수복에 사용될 수 있는 다양한 계통의 임플랜트들이 개발되어 사용되고 있다. 이중 가장 기본적인 Branemark 계통의 CeraOne 지대주, 최근에 개발된 전부도재 지대주인 CerAdapt 전부주조 지대주인 UCLA 계통등은 높은 성공률을 보이며 많이 사용되고 있다. 임상가들에 의해 나사유지형 보철물이 착탈성이란 관점에서 선호되고 있다. 시멘트유지형 보철물에서는 나사공이 없는 온전한 교합면을 유지한다는 면과 교합력을 받는 면적에 있어서 더 넓은 면을 가진다는 점등 더 많은 장점을 가진다고 주장하는 사람도 있다. 임상가들의 기호에 의해 선택되어지는 나사 유지형과 시멘트 유지형에 있어서 교합력이 야기하는 하중하에서 각각의 응력 분포를 분석할 필요성이 요구되었다. 이 연구는 단일치 수복에 사용되는 CeraOne, CerAdapt UCLA 계통에서 각각의 나사 유지형과 시멘트유지형에서의 응력분포를 삼차원 유한요소법으로 분석하고 상부 구조물에 가해지는 수직하중, 수평 하중, 경사 하중에 의해 야기되는 응력을 비교 분석한 것이다. 본 연구의 연구 결과는 다음과 같다. 1. CeraOne, CerAdapt, UCLA 지대주 모두 시멘트유지형보다 나사유지형에서 응력집중이 컸다. 2. CeraOne 시멘트유지형인 1번 모델에서 응력분산이 유리하였고, UCLA 나사 유지형인 6번 모델에서 가장 불리하였다. 3. 모든 모델에서 고정체 경부에서 가장 큰 응력 집중이 있었고 이것은 UCLA 지대주에서 가장 컸다. 4. 상부 구조물에서 주된 응력의 집중은 교합면에서 일어났다. 5. 골은 상부 피질골, 즉 고정체경부와 만나는 부위에서 가장 큰 응력의 집중이 일어났으며 수평, 경사 하중시 응력집중 양상은 힘을 가한 쪽의 반대쪽 고정체 경부에 응력이 집중되는 양상을 보였다. 6. 전체 모델과 골, 고정체 모두에서 수평 하중과 경사 하중시 보다는 수직 하중시 더 적은 응력값을 보였다.

  • PDF

PHYSICAL PROPERTIES OF DIFFERENT SELF-ADHESIVE RESIN CEMENTS AND THEIR SHEAR BOND STRENGTH ON LITHIUM DISILICATE CERAMIC AND DENTIN (수종의 자가 접착 레진 시멘트의 물성 및 lithium disilicate ceramic과 상아질에 대한 전단결합강도 비교)

  • Shin, Hye-Jin;Song, Chang-Kyu;Partk, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.184-191
    • /
    • 2009
  • The purpose of this study was to evaluate the physical properties of different self-adhesive resin cements and their shear bond strength on dentin and lithium disilicate ceramic and compare these result with that of conventional resin cement. For this study, four self-adhesive resin cements (Rely-X Unicem, Embrace Wetbond, Mexcem, BisCem), one conventional resin cement (Rely-X ARC) and one restorative resin composite (Z-350) were used. In order to evaluate the physical properties, compressive strength, diametral tensile strength and flexural strength were measured. To evaluate the shear bond strength on dentin, each cement was adhered to buccal dentinal surface of extracted human lower molars. Dentin bonding agent was applied after acid etching for groups of Rely-X ARC and Z-350. In order to evaluate the shear bond strength on ceramic, lithium disilicate glass ceramic (IPS Empress 2) disks were prepared. Only Rely-X ARC and Z-350 groups were pretreated with hydrofluoric acid and silane. And then each resin cement was adhered to ceramic surface in 2 mm diameter. Physical properties and shear bond strengths were measured using a universal testing machine. Results were as follows 1. BisCem showed the lowest compressive strength, diametral tensile strength and flexural strength. (P<0.05) 2. Self-adhesive resin cements showed significantly lower shear bond strength on the dentin and lithium disilicate ceramic than Rely-X ARC and Z-350 (P<0.05) In conclusion, self-adhesive resin cements represent the lower physical properties and shear bond strength than a conventional resin cement.

Tensile Bond Strength of Glass Ionomer Cements (글라스 아이오노대 시멘트의 인장접착강도)

  • BYUN, Seung Min;KWON, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.26 no.3
    • /
    • pp.317-324
    • /
    • 1996
  • This study was conducted to evaluate the tensile bond strength of three commercially available glass ionomer cements as orthodontic bracket adhesives. 120 premolars extracted for orthodontic treatment were prepared for bonding and standard edgewise brackets were bonded with Shofu Glaslonomer Cement (Shofu Co., U.S.A.), GC Fuji ItGC Co., Japan), KETAC-CEM(ESPE Co., West Germany) with different P/L ratio. The tensile bond strength was tested by Instron testing device after 24hours and 3months from bonding. After debracketing, bracket bases were examined to determine the failure sites. The results of this study were as follows: 1. KETAC CEM showed the highest bond strength other than measurement after 24 hours and at its original P/L ratio, and seemed to have clinically a proper bond strength. It seemed, however, that both Shofu Giaslonomer Cement and GC Fuji I had an inappropriate bond strength. 2. The incorporation of additional powder into the mixture improved the tensile bond strength. 3. Prolonged storage time improved the tensile bond strength. 4. Of the failure, failure occured at the tooth-adhesive interface(54.2%) was the most common type. The second type of failure(36.7%) was combination type, where part of the adhesive remained on the tooth and part on the bracket. And the last type of failure(9.1%) occured at the adhesive-bracket interface.

  • PDF

INFLUENCE OF THE EVAPORATOIN OF LIQUIDS OF DENTAL CEMENTS ON THE PROPERTIES OF HARDENED CEMENTS (치과용 시멘트 용액의 증발이 경화된 시멘트의 성질에 미치는 영향)

  • Kim, Hyang-Kyung;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.156-169
    • /
    • 1997
  • This study was designed to evaluate the influences of evaporation of liquid of dental cements by drying during long term using. Zinc phosphate cement, polycarboxylate cement, and glass ionomer cement were used, and evaluated the properties as follows; consistency, setting time, film thickness, solubility, and compressive strength according to the ADA specification. The specimens of control group were made by mixing the newly opened liquid using the powder-liquid ratio recommended by the manufacturer, and the specimens of ES groups were made by mixing the 10% evaporated liquid by drying with the powder-liquid ratio recommeded by the manufacturer, and the specimens of EM group were made by mixing the 10% evaporated liquid with the powder-liquid ratio modified for standard consistency. The following conclusions were drawn ; 1. The viscosity of mixture of all kinds of cements were increased by the evaporation of liquid, especially the viscosity of glass ionomer cement were influenced significantly. 2. The amount of liquid should be increased to get a standard consistency at the using of evaporated liquid of cement, the most significant increase of liquid amount was required on Ketac-Cem. 3. The setting times were increased at both cases of mixing of evaporated liquid with powder - liquid ratio recommended by manufacturer or modifided through consistency test. 4. At an experimental group of mixing of the evaporated liquid with powder-liquid ratio recommended by manufacturer, solubility was decreased and film thickness was increased. 5. By the result of evaporation of cement liquid, the compressive strength of polycarboxylate cement was increased slightly and it of glass ionomer cement was increased, however, by the increase of amount of liquid to be possible to manipulate the compressive strength were decreased.

  • PDF

Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR (도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교)

  • Yuh, Chi-Sung;Kim, Jee-Hwan;Kim, Sun-Jai;Lee, Yong-Keun;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.416-423
    • /
    • 2009
  • Statement of problem: The degree of light attenuation at the time of cementation of the PLV restoration depends on characteristics such as thickness, opacity and shade of the restorations, which interfere with light transmittance and, as a result, may decrease the total energy reaching the luting cement. Purpose: The purpose of this study was to compare the degree of conversion of light-cured resin cements measuring by FT-IR in regard to different thickness, light devices and curing time. Material and methods: In the control group, a clear slide glass (1.0 mm) was positioned between the light cured resin cement and light source. The specimens of ceramics were made with IPS Empress Esthetic. The ceramics were fabricated with varying thicknesses-0.5, 1.0, 1.5 mm with shade ETC1. Rely $X^{TM}$ Veneer with shade A3, light-cured resin cement, was used. Light-activation was conducted through the ceramic using a quartz tungsten halogen curing unit, a light emitting diode curing unit and a plasma arc curing unit. The degree of conversion of the light-cured resin cement was evaluated using FT-IR and OMNIC. One-way ANOVA and Tukey HSD test were used for statistical analysis ($\alpha$< .05). Results: The degree of conversion (DC) of photopolymerization using QTH and LED was higher than results of using PAC in the control group. After polymerization using QTH and LED, the DC results from the different ceramic thickness- 0.5 mm, 1.0 mm, 1.5 mm- did not show a significant difference when compared with those of control group. However, the DC for polymerization using PAC in the 1.5mm ceramic group showed significantly lower DC than those of the control group and 0.5 mm ceramic group (P<.05). At 80s and 160s, the DC of light-cured resin cement beneath 1.0 mm ceramic using LED was significantly higher than at 20s (P<.05). Conclusion: Within the limitation of this study, when adhering PLV to porcelain with a thickness between 0.5-1.5 mm, the use of PAC curing units were not considered however, light cured resin cements were effective when cured for over 40 seconds with QTH or LED curing units. Also, when curing the light cured resin cements with LED, the degree of polymerization was not proportional with the curing time. Curing exceeding a certain curing time, did not significantly affect the degree of polymerization.

COMPARATIVE STUDY OF PHYSICAL PROPERTIES FOR VARIOUS BAND CEMENTS (수종의 밴드 접착 시멘트의 물성에 대한 비교 연구)

  • Yang, Kyu-Ho;Kim, Ki-Baek;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.427-432
    • /
    • 2009
  • The aim of this study was to compare the shear-peel strength and the fracture site of 5 commercially available orthodontic band cements. One hundred molar bands were cemented to extracted human 3rd molars. The specimens were prepared in accordance with the manufacturer's instructions for each cement. After storage in a humidor at $37^{\circ}C$ for 24 hours, the shear debonding force was assessed for each specimen using an universal testing machine with crosshead speed of 2 mm/minute. Maximal failure stress was converted to mean shear-peel strength, MPa. The predominant site of band failure was recorded visually for all specimens as either at the band/cement or cement/enamel interface. Mean shear-peel strength of Ormco was the highest(2.44${\pm}$0.57), followed by Fuji $Ortho^{TM}$(2.24${\pm}$0.50), $Ketac-Cem^{TM}$(2.10${\pm}$0.57), 3M $Unitek^{TM}$(1.82${\pm}$0.43), $Band-Lok^{TM}$(1.73${\pm}$0.28). There were statistically significant differences between Ormco and $Band-Lok^{TM}$, Ormco and 3M $Unitek^{TM}$, and Fuji $Ortho^{TM}$ and $Band-Lok^{TM}$(p<0.05). The predominant site of bonding failure for bands cemented with the Ormco was at the band/cement interface, whereas bands cemented with Ultra $Band-Lok^{TM}$ failed predominantly at the enamel/cement interface. There was no significant difference among the other cements(Fuji $Ortho^{TM}$, 3M $Unitek^{TM}$, $Ketac-Cem^{TM}$).

  • PDF

A STUDY ON THE SHEAR BOND STRENGTH AND THE ANTICARIOGENICITY OF GLASS IONOMER CEMENT FOR BRACKET BONDING (브라켓 접착용 글라스 아이어노머 시멘트의 접착강도 및 항우식 효과에 관한 연구)

  • Kang, Yong-Joo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.538-553
    • /
    • 1999
  • The purpose of this study was to compare the shear bond strength and the anticariogenicity of glass ionomer cement with conventional bonding resin and fluoride releasing resin. After the shear bond strength test, scanning electron microscopic observation was performed for the evaluation of the fracture patterns in each group. Under the polarizing light microscope, artificially induced carious lesions were evaluated and the lesion depths of the samples were measured using image analyzing program(Image-Pro $PLUS^{TM}$, USA). 50 sound maxillary premolars were used for the bond strength test and another 30 for the anticariogenic test. Data collected were analyzed statistically using Oneway-ANOVA and Scheffe test. The results were as follows: 1. Glass ionomer groups(G-III, IV, V) generally showed the lower bond strength values than resin groups(G-I, II). 2. Among the two resin groups, G-I showed the higher bond strength than G-II without statistically significant difference between them(p>.05). 3. Within glass ionomer groups, statistical significance was found between G-III and G-V with the superior bond strength in G-V (p<.05). 4. Under the SEM, adhesive failure was the predominant fracture pattern in G-I and II, whereas cohesive failures were mainly observed in G-III. In G-IV and V, mixed type of pattern where the both fracture patterns coexisted within samples could be seen. 5. In evaluation of the depth of artificially developed carious lesion, glass ionomer group showed shallower depth than resin groups with statistical significance between G-III and G-I, II(p<.05). Among resin groups, fluoride releasing resin(G-II) showed the shallower depth than conventional resin(G-I)(p<.05).

  • PDF