Comparative study on the radiopacity of different resin-based implant cements |
Han, Kyeong-Hwan
(Post Graduate School of Clinical Dentistry, Institute for Clinical Dental Reserch, Korea University)
Cheon, Ho-Young (Post Graduate School of Clinical Dentistry, Institute for Clinical Dental Reserch, Korea University) Kim, Min-Su (Post Graduate School of Clinical Dentistry, Institute for Clinical Dental Reserch, Korea University) Shin, Sang-Wan (Post Graduate School of Clinical Dentistry, Institute for Clinical Dental Reserch, Korea University) Lee, Jeong-Yol (Post Graduate School of Clinical Dentistry, Institute for Clinical Dental Reserch, Korea University) |
1 | Attar N, Tam LE, McComb D. Mechanical and physical properties of contemporary dental luting agents. J Prosthet Dent 2003;89:127-34. DOI ScienceOn |
2 | Callan DP, Cobb CM. Excess cement and peri-implant disease. J Implant Adv Clin Dent 2009;1:61-8. |
3 | Wilson TG Jr. The positive relationship between excess cement and peri-implant disease: a prospective clinical endoscopic study. J Periodontol 2009;80:1388-92. DOI ScienceOn |
4 | Gapski R, Neugeboren N, Pomeranz AZ, Reissner MW. Endosseous implant failure influenced by crown cementation: a clinical case report. Int J Oral Maxillofac Implants 2008;23:943-6. |
5 | O'Rourke B, Walls AW, Wassell RW. Radiographic detection of overhangs formed by resin composite luting agents. J Dent 1995;23:353-7. DOI ScienceOn |
6 | Soares CJ, Santana FR, Fonseca RB, Martins LR, Neto FH. In vitro analysis of the radiodensity of indirect composites and ceramic inlay systems and its influence on the detection of cement overhangs. Clin Oral Investig 2007;11:331-6. DOI |
7 | Reis JM, Jorge EG, Ribeiro JG, Pinelli LA, Abi-Rached FO, Tanomaru-Filho M. Radiopacity evaluation of contemporary luting cements by digitization of images. ISRN Dent 2012;2012:1-5. |
8 | Pette GA, Ganeles J, Norkin FJ. Radiographic appearance of commonly used cements in implant dentistry. Int J Periodontics Restorative Dent 2013;33:61-8. DOI |
9 | ISO 4049. Dentistry: Polymer-based restorative materials. Geneva: ISO International Organization for Standardization; 2009. |
10 | Wadhwani C, Hess T, Faber T, Piñeyro A, Chen CS. A descriptive study of the radiographic density of implant restorative cements. J Prosthet Dent 2010;103:295-302. DOI ScienceOn |
11 | Agar JR, Cameron SM, Hughbanks JC, Parker MH. Cement removal from restorations luted to titanium abutments with simulated subgingival margins. J Prosthet Dent 1997;78:43-7. DOI ScienceOn |
12 | Altintas SH, Yildirim T, Kayipmaz S, Usumez A. Evaluation of the radiopacity of luting cements by digital radiography. J Prosthodont 2013;22:282-6. DOI ScienceOn |
13 | Begoña Ormaechea M, Millstein P, Hirayama H. Tube angulation effect on radiographic analysis of the implant-abutment interface. Int J Oral Maxillofac Implants 1999;14:77-85. |
14 | Akça K, Iplikçioğlu H, Cehreli MC. Comparison of uniaxial resistance forces of cements used with implant-supported crowns. Int J Oral Maxillofac Implants 2002;17:536-42. |
15 | GaRey DJ, Tjan AH, James RA, Caputo AA. Effects of thermocycling, load-cycling, and blood contamination on cemented implant abutments. J Prosthet Dent 1994;71:124-32. DOI ScienceOn |
16 | Cho-Yan Lee J, Mattheos N, Nixon KC, Ivanovski S. Residual periodontal pockets are a risk indicator for peri-implantitis in patients treated for periodontitis. Clin Oral Implants Res 2012;23:325-33. DOI ScienceOn |
17 | Shapoff CA, Lahey BJ. Crestal bone loss and the consequences of retained excess cement around dental implants. Compend Contin Educ Dent 2012;33:94-6, 98-101. |
18 | Wilson TG Jr. The positive relationship between excess cement and peri-implant disease: a prospective clinical endoscopic study. J Periodontol 2009;80:1388-92. DOI ScienceOn |
19 | Schwedhelm ER, Lepe X, Aw TC. A crown venting technique for the cementation of implant-supported crowns. J Prosthet Dent 2003;89:89-90. DOI ScienceOn |
20 | Wadhwani C, Piñeyro A. Technique for controlling the cement for an implant crown. J Prosthet Dent 2009;102:57-8. DOI ScienceOn |
21 | Wadhwani C, Rapoport D, La Rosa S, Hess T, Kretschmar S. Radiographic detection and characteristic patterns of residual excess cement associated with cement-retained implant restorations: a clinical report. J Prosthet Dent 2012;107:151-7. DOI ScienceOn |
22 | Pauletto N, Lahiffe BJ, Walton JN. Complications associated with excess cement around crowns on osseointegrated implants: a clinical report. Int J Oral Maxillofac Implants 1999;14:865-8. |
23 | De Rouck T, Collys K, Cosyn J. Single-tooth replacement in the anterior maxilla by means of immediate implantation and provisionalization: a review. Int J Oral Maxillofac Implants 2008;23:897-904. |
24 | Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants 2003;18:719-28. |
25 | Lee A, Okayasu K, Wang HL. Screw- versus cement-retained implant restorations: current concepts. Implant Dent 2010;19:8-15. DOI ScienceOn |
26 | Chee W, Jivraj S. Screw versus cemented implant supported restorations. Br Dent J 2006;201:501-7. DOI ScienceOn |
27 | Chaar MS, Att W, Strub JR. Prosthetic outcome of cement-retained implant-supported fixed dental restorations: a systematic review. J Oral Rehabil 2011;38:697-711. DOI ScienceOn |
28 | Nissan J, Narobai D, Gross O, Ghelfan O, Chaushu G. Long-term outcome of cemented versus screw-retained implant-supported partial restorations. Int J Oral Maxillofac Implants 2011;26:1102-7. |
29 | Ramp MH, Dixon DL, Ramp LC, Breeding LC, Barber LL. Tensile bond strengths of provisional luting agents used with an implant system. J Prosthet Dent 1999;81:510-4. DOI ScienceOn |
30 | Koka S, Ewoldsen NO, Dana CL, Beatty MW. The effect of cementing agent and technique on the retention of a CeraOne gold cylinder: a pilot study. Implant Dent 1995;4:32-5. DOI ScienceOn |
31 | Clayton GH, Driscoll CF, Hondrum SO. The effect of luting agents on the retention and marginal adaptation of the CeraOne implant system. Int J Oral Maxillofac Implants 1997;12:660-5. |
32 | Dumbrigue HB, Abanomi AA, Cheng LL. Techniques to minimize excess luting agent in cement-retained implant restorations. J Prosthet Dent 2002;87:112-4. DOI ScienceOn |