• Title/Summary/Keyword: 측정 정밀도 향상

Search Result 463, Processing Time 0.026 seconds

Improvement of Precision in Ferroelectric Polarization Hysteresis Measurement (강유전체 분극 이력곡선의 측정 정밀도 향상)

  • Jae Hwan Park
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.3
    • /
    • pp.51-55
    • /
    • 2023
  • Measurement of the ferroelectric polarization hysteresis curve is an important means of overall evaluation and interpretation of the ferroelectric structure and dielectric properties. If a resistive component is included in the ferroelectric sample, an error is included in the measured value of the spontaneous polarization. When configuring the electrical circuit to measure the polarization, by properly utilizing the external resistance corresponding to the resistive component included in the sample, the error due to the resistive loss of the sample was excluded and the size of the ferroelectric polarization induced inside could be accurately measured. It is expected that the displacement and dielectric characteristics of ions inside the ferroelectric can be more accurately evaluated through the evaluation of such an accurate polarization hysteresis curve.

Improvement of Sensitivity to In-plane Strain/Deformation Measurement by Micro-ESPI Technique (마이크로 ESPI 기법에 의한 면내 변형 측정 민감도 향상)

  • Kim D.I.;Huh Y.H.;Kee C.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1442-1445
    • /
    • 2005
  • Several test methods, including micro strain/deformation measurement techniques, have been studied to more reliably measure the micro properties in micro/nano materials. Therefore, in this study, the continuous measurement of in-plane tensile strain in micro-sized specimens of thin film materials was introduced using the micro-ESPI technique. TiN and Au thin films 1 and $0.47\;\mu{m}$ thick, respectively, were deposited on the silicon wafer and fabricated into the micro-sized tensile specimens using the electromachining process. The micro-tensile loading system and micro-ESPI system were developed to measure the tensile strain during micro-tensile test. The micro-tensile stress-strain for these materials was determined using the algorithm for continuous strain measurement. Furthermore, algorithm for enhancing the sensitivity to measurement of in-plane tensile strain was suggested. According to the algorithm for enhancement of sensitivity, micro-tensile strain data between interfringe were calculated. It is shown that the algorithm for enhancement of the sensitivity suggested in this study makes the sensitivity to the in-plane tensile strain increase.

  • PDF

In-Situ Evaluation Technique for Hydraulic Conductivity in Excavation Disturbed Zone (EDZ) (굴착영향영역(EDZ) 투수특성의 실험적 평가기술)

  • Kim, Hyung-Mok;Ryu, Dong-Woo;Synn, Joong-Ho
    • Tunnel and Underground Space
    • /
    • v.18 no.2
    • /
    • pp.91-97
    • /
    • 2008
  • In this paper, in-situ technique for measuring hydraulic conductivity of Excavation Disturbed Zone (EDZ) in a direct way and its application to an Underground Research Laboratory (URL) site were introduced. It was understood that both the EDZ oriented test equipment as a hardware and analysis/evaluation technique as a software should be integrated for upgrading a quality of estimated EDZ hydraulic conductivity. The well-estimated EDZ hydraulic conductivity is expected to enhance a reliability of stability evaluation for caverns under groundwater table and design of a waterproof or drainage system as well as a grout system.

Study on Polarization Characteristics of Optical Device and Improvement of Measurement Precision of Normal Incidence Ellipsometer for Measuring Optical Anisotropy of a Micro Spot (미소면적 광학이방성 정밀 측정을 위한 수직반사형 타원계의 광소자 편광특성 및 측정정밀도 향상 연구)

  • Lyum, Kyoung Hun;Park, Sang Uk;Seo, Young Jin;Lee, Min Ho;Kim, Woong Ki;Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.6
    • /
    • pp.274-280
    • /
    • 2012
  • A normal incidence ellipsometer is fabricated to measure the optical anisotropy of a small spot whose diameter is less than $8.0{\mu}m$, by adding a beam splitter and a prism to the conventional rotating analyzer type ellipsometer. The polarizing actions of the added optical components are calibrated to improve the accuracy of the anisotropy measurement. The standard deviation of the optical anisotropy factor decreased to 0.00083, and the variation of the optical anisotropy factor of rutile versus sample azimuth angle variation also decreased to 0.015, after adoption of a non-polarizing beam splitter and a quarter wavelength phase retarder, followed by removal of the optical fiber and a careful choice of measurement wavelength.

A study on Profile Measurement for Railway Wheels using High Speed Camera and Vision Technology (고속 하이비젼 카메라 기술을 이용한 철도차량 차륜형상 측정에 관한 연구)

  • Won, Si-Tae;Kwon, Seok-Jin;Huh, Sung-Bum
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • Maintenance and repair devices used for the inspection of the main parts of domestic railway vehicles have been imported from abroad. Especially, one of the representative domestic devices, the 'Wheel Profile Inspector System (WPIS)', was made by benchmarking foreign devices; this vehicle has been operated in the field. However, problems such as the reliability and performance of the WPIS in operation have appeared. In this study, in order to improve the precision and reliability of the WPIS for maintenance and inspection of railway vehicle wheels, the researchers improved the railway vehicle's WPIS by applying high-speed vision camera technology and an optimized image algorithm. The test results show that the reliability of the developed WPIS improved by approximately 10.4% compared to that of the conventional system.

교육 및 연구용 FMS의 개발현황보고 : 개념설계 및 Layout(상세설계)

  • 편영식;주장용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.434-440
    • /
    • 1993
  • 국제경쟁력 향상을 위한 주요채택전략으로 유연자동화제조시스템의 보급이 급격히 확대되고 있다. 그러나 시스템의 개발.제작과 운영을 담당할 기술자,기술관리자 및 고급기능인의 확보가 전제되지 않는한 성공적인 투자를 기대할 수가 없다. 본 논문에서는 이러한 담당자 양성시 필수과정인 연구개발실험 및 운영실습에 사용될 적정한 유연자동화제조시스템의 개발과정중 일부인 개념설계 및 Layout내용을 정리하여 보고한다. 기본적으로 적정비용으로 일반산업용과 동일한 기능 (Hardware는 경절삭산업용, 소프트웨어는 일반산업용)을 갖춘 시스템으로서 실험 침 실습에 들어가는 비용도 최소화할 수 있도록 설계한다. 또한 System Controller는 시스템 성능향상과 무인가동시간확장에 필요한 소프트웨어 (공구상태감시, 자동측정 및 보정,Dynamic Scheduling등) 의 개발과 실험이 용이하도록 구성하고,산학연 공동연구체제를 구축하여 지속적인 개발이 가능케 한다. 필요시 모든 Source Program도 공개할 예정이다.

  • PDF

Improvement of the Flatness for Disk type Gear using Taguchi Method (다구찌 기법을 이용한 원판 기어의 평탄도 향상)

  • Jung, Tae-Sung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05b
    • /
    • pp.533-536
    • /
    • 2011
  • 기어는 중요한 핵심 기계요소 중 하나로서 기계적 물성이 강화된 엔지니어링 플라스틱의 개발과 제품의 성능 향상 및 소형화, 경량화, 저소음화 등의 소비자 요구를 만족시키기 위한 노력에 편승하여 정밀도가 높은 플라스틱 기어에 대한 생산 요구가 증대되고 있는 실정이다. 본 논문에서는 시력 측정 장치인 자동굴절검사기용 디스크 기어에 대하여 변형을 최소화하기 위한 성형조건 최적화를 수행하였다. 사출 공정의 주요 공정변수를 사출온도, 충진시간과 보압압력, 금형온도로 정하고 다구치 방법에 의해 성형 해석으로 예측된 변형량을 분석한 결과 사출온도와 보압압력이 원판형 기어의 Z방향 변형에 가장 큰 영향을 미치는 것을 알 수 있었다.

  • PDF

GPS 가강수량 정확도 향상을 위한 라디오미터와의 비교실험

  • Son, Dong-Hyo;Jo, Jeong-Ho;Baek, Jeong-Ho;No, Gyeong-Min
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.36.3-36.3
    • /
    • 2010
  • 대기 수증기량의 정확한 추정은 우주측지 정밀도 향상에 필수적이다. 대류층 지연오차의 주요 원인인 대기 수증기량을 추정하는 대표적인 시스템으로는 라디오존데, 라디오미터, GPS 등이 있다. 한국천문연구원은 GPS 가강수량의 상시 비교검증을 위해 2009년 7월부터 라디오미터를 도입하여 비교관측을 수행하고 있다. 라디오미터는 대기복사의 밝기온도를 측정하여 가강수량을 산출하는 시스템으로써, 24시간 연속관측이 가능하고 실시간으로 관측결과를 확인할 수 있으나, 강수시 불안정하다. 2009년 7월부터 최근까지 GPS와 라디오미터 가강수량 결과간 비교로부터 0.1mm, 1.8mm의 편향과 표준편차, 0.98의 상관관계계수를 산출하였다. 현재 두 시스템의 가강수량을 10분 간격으로 비교하고 있으며, 그 결과를 웹으로 표출하는 시스템을 구축하여 운영하고 있다.

  • PDF

An Implementation of Smart E-Calipers for Mobile Phones (모바일 폰을 이용한 스마트 E-캘리퍼스 구현)

  • Yun, Han-Kyung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.5
    • /
    • pp.331-337
    • /
    • 2020
  • The study is underway with the goal of developing an app that will replace vernier calipers using a smartphone's high-performance camera. The specifications of the camera mounted on recent smart phones have evolved so that usually has a 12 Mpixels of image sensor and its size of the pixel is 1.4㎛ and the size of the image sensor is 1 / 2.55 in. The proposed algorithm will apply to develop a precision measuring application that will compete with the Vernier calipers. Most existing applications cannot guarantee an accuracy in scale because the scale of the ruler displayed on the image is unclear or the size of the measurement object varies depending on the distance between the camera and the measurement object. In addition, another accurate measuring tools using lasers are also available, but they are limited because they are expensive. Therefore, if easy-to-carry and precise applications are developed, it is possible to substitute existing measurement tools. The proposed correction algorithm is an algorithm that automatically corrects the distorted source image using the shape and size information of the known template. The e-calipers are applications that display the distance when the area to be measured is specified in the corrected image.

Improving the Accuracy of the Tapped Delay Time-to-Digital Converter Using Field Programmable Gate Array (Field-Programmable Gate Array를 사용한 탭 딜레이 방식 시간-디지털 변환기의 정밀도 향상에 관한 연구)

  • Jung, Do-Hwan;Lim, Hansang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.182-189
    • /
    • 2014
  • A tapped delay line time-to-digital converter (TDC) can be easily implemented using internal carry chains in a field-programmable gate array, and hence, its use is widespread. However, the tapped delay line TDC suffers from performance degradation because of differences in the delay times of dedicated carry chains. In this paper, a dual edge measurement method is proposed instead of a typical step signal to the delay cell to compensate for the performance degradation caused by wide-delay cells in carry chains. By applying a pulse of a fixed width as an input to the carry chains and using the time information between the up and down edges of the signal pulse, the timing accuracy can be increased. Two dedicated carry chain sites are required for the dual edge measurements. By adopting the proposed dual edge measurement method, the average delay widths of the two carry chains were improved by more than 35%, from 17.3 ps and 16.7 ps to 11.2 ps and 10.1 ps, respectively. In addition, the maximum delay times were improved from 41.4 ps and 42.1 ps to 20.1 ps and 20.8 ps, respectively.