• Title/Summary/Keyword: 측정 장치

Search Result 6,297, Processing Time 0.048 seconds

Development of Lead Free Shielding Material for Diagnostic Radiation Beams (의료영상용 방사선방호를 위한 무납차폐체 개발)

  • Choi, Tae-Jin;Oh, Young-Kee;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.232-237
    • /
    • 2010
  • The shielding materials designed for replacement of lead equivalent materials for lighter apron than that of lead in diagnostic photon beams. The absorption characteristics of elements were applied to investigate the lead free material for design the shielding materials through the 50 kVp to 110 kVp x-ray energy in interval of 20 kVp respectively. The idea focused to the effect of K-edge absorption of variable elements excluding the lead material for weight reduction. The designed shielding materials composited of Tin 34.1%, Antimon 33.8% and Iodine 26.8% and Polyisoprene 5.3% gram weight account for 84 percent of weight of lead equivalent of 0.5 mm thickness. The size of lead-free shielder was $200{\times}200{\times}1.5\;mm^3$ and $3.2\;g/cm^3$ of density which is equivalent to 0.42 mm of Pb. The lead equivalent of 0.5 mm thickness generally used for shielding apron of diagnostic X rays which is transmitted 0.1% for 50 kVp, 0.9% for 70 kVp and 3.2% for 90 kVp and 4.8% for 110 kVp in experimental measurements. The experiment of transmittance for lead-free shielder has showed 0.3% for 50 kVp, 0.6% for 70 kVp, 2.0% for 90 kVp and 4.2% for 110 kVp within ${\pm}0.1%$. respectively. Using the attenuation coefficient of experiments for 0.5 mm Pb equivalent of lead-free materials showed 0.1%. 0.3%, 1.0% and 2.4%, respectively. Furthermore, the transmittance of lead-free shielder for scatter rays has showed the 2.4% in operation energy of 50 kVp and 5.9% in energy of 110 kVp against 2.4% and 5.1% for standard lead thickness within ${\pm}0.2%$ discrepancy, respectively. In this experiment shows the designed lead-free shielder is very effective for reduction the apron weight in diagnostic radiation fields.

The Comparison between Single Shot Turbo Spin Echo and B-FFE (Balanced Turbo Field-echo) in the Differentiation of Focal Liver Lesions (국소 간병변 감별에서 단발고속스핀에코 기법과 균형항정상 태세차를 이용한 고속영역 기법간의 비교)

  • Kim, Young-Chul;Kim, Myeong-Jin;Cha, Seung-Whan;Chung, Yong-Eun;Han, Kwang-Hyup;Choi, Jin-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 2007
  • Purpose : To determine the diagnostic accuracy of four different sequences : moderately T2 weighted, two heavily T2-weighted single shot turbo spin-echo sequence and breath-hold axial-2D balanced turbo field-echo sequence(bFFE) for characterization of focal lesions. Materials and Methods : During the 3-month period between June and August 2005, seventy-six patients were proved to have ninety-three focal hepatic lesions on MR imaging. The patients consisted of 49 men and 27 women (age range, 15-75 years; mean age, 56.23 years). All MR images were acquired on a 1.5-T MR using the following sequences: 1. A breath-hold axial T2-weighted single shot turbo spin-echo sequence, 2. a breath-hold axial-2D balanced turbo field-echo sequence. Two radiologists performed quantitative analysis. Another radiologist measured the lesion-to-liver contrast-to-noise ratio at the region-of-interest in the four sequences. Results : There was no significant difference in inter-observer variability between the four sequences. The accuracy for both cyst and malignancy of moderate T2 weighted MRI (echo time: 80 msec) was also highest. There was significant difference for lesion characterization between moderate T2 weighted MRI and balanced steady state procession (p-value: 0.004) in the second reader. For longer echo time, the CNR of cystic lesions were markedly increased in comparison to lesions of other component. Conclusion : The accuracy and inter-observer variability of single shot turbo spin echo T2 weighted sequence was higher than bFFE. Although there was no statically significant difference, moderate T2 weighted MRI (echo time: 80 msec) was more accurate than heavily T2 weighted sequence (echo time: 300 msec). If the results for lesion characterization is equivocal in TE 80, the addition of heavily T2 weighted MRI (echo time: 180 msec) can be helpful.

  • PDF

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Types of Perception toward End-of-Life Medical Decision-making of Clinical Nurses: Q-Methodological Approach (말기환자의 의료적 의사결정에 관한 임상간호사의 인식: Q 방법론적 접근)

  • Jo, Kae-Hwa;Kim, Yeon-Ja;Sohn, Ki-Cheul
    • Journal of Hospice and Palliative Care
    • /
    • v.15 no.1
    • /
    • pp.18-29
    • /
    • 2012
  • Purpose: We analyzed how clinical nurses in Korea perceive terminally ill patients' medical decision-making. Methods: The Q-methodology which analyzes the subjectivity of each item was used. We selected 34 Q-statements among those provided by each of 37 subjects and grouped them into a shape of normal distribution using a 9 point scale. The collected data were analyzed using a QUANL PC program. Results: Four types of perception toward medical decision-making were identified. Type I focuses on patient participation, and Type II emphasizes the role of health professionals. Type III is characterized by an open-minded culture toward death, and Type IV values the role of family members. Conclusion: The results of this study indicate the need for development of a multi-disciplinary curriculum medical decision-making and death for medical and nursing students.

Numerical analysis of FEBEX at Grimsel Test Site in Switzerland (스위스 Grimsel Test Site에서 수행된 FEBEX 현장시험에 대한 수치해석적 연구)

  • Lee, Changsoo;Lee, Jaewon;Kim, Geon-Young
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.359-381
    • /
    • 2020
  • Within the framework of DECOVALEX-2019 Task D, full-scale engineered barriers experiment (FEBEX) at Grimsel Test Site was numerically simulated to investigate an applicability of implemented Barcelona basic model (BBM) into TOUGH2-MP/FLAC3D simulator, which was developed for the prediction of the coupled thermo-hydro-mechanical behavior of bentonite buffer. And the calculated heater power, temperature, relative humidity, total stress, saturation, water content and dry density were compared with in situ data monitored in the various sections. In general, the calculated heater power and temperature provided a fairly good agreement with experimental observations, however, the difference between power of heater #1 and that of heater #2 could not captured in the numerical analysis. It is necessary to consider lamprophyre with low thermal conductivity around heater #1 and non-simplified installation progresses of bentonite blocks in the tunnel for better modeling results. The evolutions and distributions of relative humidity were well reproduced, but hydraulic model needs to be modified because the re-saturation process was relatively fast near the heaters. In case of stress evolutions due to the thermal and hydraulic expansions, the computed stress was in good agreement with the data. But, the stress is slightly higher than the measured in situ data at the early stage of the operation, because gap between rock mass and bentonite blocks have not been considered in the numerical simulations. The calculated distribution of saturation, water content, and dry density along the radial distance showed good agreement with the observations after the first and final dismantling. The calculated dry density near the center of the FEBEX tunnel and heaters were overestimated compared with the observations. As a result, the saturation and water content were underestimated with the measurements. Therefore, numerical model of permeability is needed to modify for the production of better numerical results. It will be possible to produce the better analysis results and more realistically predict the coupled THM behavior in the bentonite blocks by performing the additional studies and modifying the numerical model based on the results of this study.

Development of Heat Exchanger for Fermentation Heat Utilization from Waste Woody Biomass (목질계 폐바이오메스의 발효열이용 열교환기의 개발)

  • Cho, Nam-Seok;Choi, Tae-Ho;Kim, Hong-Eun;Lee, Suk-Ho;Lee, Chung-Koo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.94-104
    • /
    • 2009
  • It is urgently required to develop the production of fermentation-heat energy from the waste agricultural and forest biomass and its effective heat exchanging system for the supply of warm water to rural households and greenhouses. In this study 3 helical-type and 1 plate-type heat exchangers using 3 different waste biomasses [e.g. hardwood (HW) sawdust (100%), softwood (SW) sawdust : HW sawdust (50 : 50) and HW sawdust : grass (90 : 10)] were applied in order to find out the best heat recovery system. The heat exchanger was basically considered to improve the overall heat recovery efficiency, to minimize heat loss and to simplify manufacturing, assembling and breaking up the fermenting beds. The helical-type heat exchanger (HX-H3) installed in fermenting bed of HW sawdust : grass (90 : 10) showed relatively higher temperature profiles, in particular mid- and upper-parts than lower and surface parts during 45-day fermentation process. The maximum temperature was ranged from $40^{\circ}C$ to $65^{\circ}C$ with average $60^{\circ}C$. The water temperature of tank outlet was ranged to $33{\sim}48^{\circ}C$ during whole measuring periods. By the way plate-type one (HX-P) installed in same biomass compositional fermenting bed showed $64.5{\sim}76.5^{\circ}C$ at center part, and $43{\sim}56^{\circ}C$ and $42{\sim}58^{\circ}C$, water tank and tank outlet temperatures, respectively, during 100 day measurement. It could be concluded that the plate-type heat exchanger (HX-P) provides not only the effective heating for the rural households and greenhouses, but also having the best heat recovery performance, easy manufacturing, assembling and breaking up the systems.

Protective Effects of Adenosine-enriched Cardioplegic Solution in Ischemic Myocardium (Adenosine을 함유한 심정지액의 심근보호 효과)

  • 이호철;정태은
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.199-207
    • /
    • 1996
  • Ischemic myocardial damage is inevitable to cardiac surgery. Myocardial damage after initiation of reperfusion through the coronary arteries is one of the most important determinants of a successful surgery. Adenosine is a potent vasodilator, and is also known to induce rapid cardioplegic arrest by its property of antagonizing cardiac calcium channels and activating the potassium channel. Thus, we initiated this study with adenosine to improve postischemic recovery in the isolated rat heart. We tested the hypothesis that adenosine could be more effective than potassium in inducing rapid cardiac arrest and enhancing postischemlc hemodynamic recovery. Isolated rat hearts, connected to the Langendorff appratus, were perfused with Krebs-Henseleit buffer and all hearts were subjected to arrest for 60 minutes. Three groups of hearts were studied according to the composition of cardioplegic solutions : Group A (n=10), adenosine 10mmo1/L+potassium free modified St. Thomas cardioplegia : Group B (n=10), adenosine 400mo1/L+S1. Thomas cardioplegia:Group C(control, n=10), St. Thomas cardioplegia. Adenosine-treated groups (group A & B) resulted in more rapid cardiac arrest than control group (C) (p< 0.01). There was greater improvement in recovery of coronary blood flow at 20 and 30 minutes of reperfusion in group A and at 20 minutes in group B when compared with control group(p<0.01). Recovery of systolic blood pressure at 10 minutes after reperfusion in group A and B was significantly superior to that in group C (p<0.01). Recovery of dp/dt at 10 minute after reperfusion in group A was also significantly superior to group C (p<0.05). Group A and B showed better recovery rates than control group in aortic blood flow, cardiac output, and heart rate, but there were no statistical differences. CPK levels of coronary flow in group A were significantly low (p< 0.01). We concluded that adenosine-enriched cardioplegic solutions have better effects on rapid cardiac arrest and postischemic recovery when compared with potassium cardioplegia.

  • PDF

Assessment of Quantitative Analysis Methods for Lung F-18-Fluorodeoxyglucose PET (폐 종양 FDG PET 영상의 다양한 추적자 역학 분석 방법 개발과 유용성 고찰)

  • Kim, Joon-Young;Choi, Yong;Choi, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Kim, Yong-Jin;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.332-343
    • /
    • 1998
  • Purpose: The purpose of this study was to assess the diagnostic accuracy of various quantitation methods using F-18-fluorodeoxyglucose (FDG) in patients with malignant or benign lung lesion. Materials and Methods: 22 patients (13 malignant including 5 bronchoalverolar cell cancer; 9 benign lesions including 1 hamartoma and 8 active inflammation) were studied after overnight fasting. We performed dynamic PET imaging for 56 min after injection of 370 MBq (10 mCi) of FDG. Standardized uptake values normalized to patient's body weight and plasma glucose concentration (SUVglu) were calculated. The uptake rate constant of FDG and glucose metabolic rate were quantified using Patlak graphical analysis (Kpat and MRpat), three compartment-five parameter model (K5p, MR5p), and six parameter model taking into account heterogeneity of tumor tissue (K6p, MR6p). Areas under receiver operating characteristic curves (ROC) were calculated for each method. Results: There was no significant difference of rate constant or glucose metabolic rate measured by various quantitation methods between malignant and benign lesions. The area under ROC curve were 0.73 for SUVglu, 0.66 for Kpat, 0.77 for MRpat, 0.71 for K5p, 0.73 for MR5p, 0.70 for K6p, and 0.78 for MR6p. No significant difference of area under the ROC curve between these methods was observed except the area between Kpat vs. MRpat (p<0.05). Conclusion: Quantitative methods did not improve diagnostic accuracy in comparison with nonkinetic methods. However, the clinical utility of these methods needs to be evaluated further in patients with low pretest likelihood of active inflammation or bronchoalveolar cell carcinoma.

  • PDF

The pH Reduction of the Recycled Aggregate Originated from the Waste Concrete by the scCO2 Treatment (초임계 이산화탄소를 이용한 폐콘크리트 순환골재의 중성화)

  • Chung, Chul-woo;Lee, Minhee;Kim, Seon-ok;Kim, Jihyun
    • Economic and Environmental Geology
    • /
    • v.50 no.4
    • /
    • pp.257-266
    • /
    • 2017
  • Batch experiments were performed to develop the method for the pH reduction of recycled aggregate by using $scCO_2$ (supercritical $CO_2$), maintaining the pH of extraction water below 9.8. Three different aggregate types from a domestic company were used for the $scCO_2$-water-recycled aggregate reaction to investigate the low pH maintenance of aggregate during the reaction. Thirty five gram of recycled aggregate sample was mixed with 70 mL of distilled water in a Teflon beaker, which was fixed in a high pressurized stainless steel cell (150 mL of capacity). The inside of the cell was pressurized to 100 bar and each cell was located in an oven at $50^{\circ}C$ for 50 days and the pH and ion concentrations of water in the cell were measured at a different reaction time interval. The XRD and SEM-EDS analyses for the aggregate before and after the reaction were performed to identify the mineralogical change during the reaction. The extraction experiment for the aggregate was also conducted to investigate the pH change of extracted water by the $scCO_2$ treatment. The pH of the recycled aggregate without the $scCO_2$ treatment maintained over 12, but its pH dramatically decreased to below 7 after 1 hour reaction and maintained below 8 for 50 day reaction. Concentration of $Ca^{2+}$, $Si^{4+}$, $Mg^{2+}$ and $Na^+$ increased in water due to the $scCO_2$-water-recycled aggregate reaction and lots of secondary precipitates such as calcite, amorphous silicate, and hydroxide minerals were found by XRD and SEM-EDS analyses. The pH of extracted water from the recycled aggregates without the $scCO_2$ treatment maintained over 12, but the pH of extracted water with the $scCO_2$ treatment kept below 9 of pH for both of 50 day and 1 day treatment, suggesting that the recycled aggregate with the $scCO_2$ treatment can be reused in real construction sites.

Evaluation of Compost Qualities with or without Microbial Inoculation for Food Waste Composting (미생물제 첨가유무에 따른 음식물 쓰레기 퇴비 부숙도 평가)

  • Jeong, Jun-Young;Jung, Kwang-Yong;Nam, Sung-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.3
    • /
    • pp.280-286
    • /
    • 1999
  • This studies were conducted to evaluate efficiency of microbial inoculator for active composting of food wastes. The Microbial inoculators used in this studies were purchased from different comparise to evaluate their effectiveness for composting of food waste in Korea. The number of bacteria growing at $30^{\circ}C$ in commercial inoculator collected were below $91.0{\times}10^8\;CFU/g$ which were counted from well cured compost made by animal manure. The number of bacteria in commercial microbial inoculator, such as FL, VP, B9, CM and GE were higher than that of composted at $50^{\circ}C$ or $60^{\circ}C$ of incubation temperature. Fungi were counted in GR, VP and B9 as over $10^3CFU/g$ at $30^{\circ}C$ of incubation temperature, while fungi of all the commercial inoculator collected could not grown at $50^{\circ}C$ and $60^{\circ}C$. Actinomycetes in most of the these had higher number($10^5CFU/g$) than that of compost : however, it was not detected at $60^{\circ}C$ incubation temperature from all the samples collected. The amount of carbon dioxid production was order to VP>HU>B9>GE>CM>Control>Compost in the lab scale composting test with or without inoculation of commercial inoculators, however, but the difference in carbon dioxide production was similar among each treatments. The effect of inoculation on composting parmeter such as pH changes, temperature increasing and change of chemicals properties were a little among each treatments, with or without inoculation of commercial inoculator in active composting of food waste. Using commercial inoculator did not show any statistical difference in food waste composting process under various condition such as pH changes, temperature changes, etc.

  • PDF