  • Late Cretaceous to early Tertiary volcanic rocks in the Kyongsang basin exhibit high-K calc-alkaline characteristics, and originated from the magmatism related genetically to subduction of Kula-Pacific plate. They represent HFSE depletion and LlLE enrichment characteristics as shown by magmas related to subduction. Early studies on the depth of magma generation has been estimated as 180-230 km based on K-h relation should be reevaluated, because the depth of peridotite partial melting with 0.4 wt. % water is 80-120 km at subduction zone, and subducting slab in premature arc can melted even lower than 70 km. Moreover the increase of potassium contents depends on either contamination of crustal material and fluids of subducting slab or low degree of partial melting. If the inclination of subduction zone is 30 degrees and the depth to the Benioff zone is 180-230 km, the calculated distance between the volcanic zone and trench axis would be 310-400 km. It is unlikely because the distance between the Kyongsang basin and trench during late Cretaceous to early Tertiary is closer than this value and not comparable with generally-accepted models in subduction zone magmatism. $K_{55}$ of the volcanics in the Kyongsang basin is 0.3-2.3 wt.% and the average indicate that the depth ranges between 80-170 km on the diagram of Marsh, Carmichael (1974). Fractionation from garnet lherzolite, assumed the depth of 180-230km, is not consistent with the REE patterns of the volcanoes in the Kyongsang basin. Futhermore, the range of depth suggested by many workers, who studied magmatism related to subduction, imply shallower than this depth. Crustal thickness calculated by the content of CaO and $Na_2O$ is about 30 km and about 35 km, respectively. Paleo-crustal thickness during late Cretaceous to early Tertiary times in the Kyongsang basin inferred about 30 km calculated by La/Sm versus LaJYb data, which is also supported by many previous studies.

  • PDF

The Evaluation of Lateral Scatter Ray of Gamma Camera (Gamma Camera에 있어 측면 선란선의 영향에 대한 평가)

  • Kim, Jae-Il;Lee, Eun-Byeol;Cho, Seong-Wook;Noh, Kyeong-Woon;Kang, Keon-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.46-50
    • /
    • 2018
  • Purpose Generally, a collimator that installed in front of detector set a direction of gamma ray and remove a scatter ray. By the way, a lateral or oblique scatter ray is detected into crystal through collimator. At this study, we will evaluate a mount of count and spectrums of lateral scatter ray. Materials and Methods We used the SKY LITE (philips, netherlands) as a gamma camera, and $^{99m}Tc$, 1.11 GBq point source as a phantom. we put this point source at backside 50 cm of detector. After acquiring this for 1 min, we turned a detector next 10 degrees. Likely this, we acquired images at every 10 degrees from $0^{\circ}$ to $360^{\circ}$, analyzed images and spectrums. In case of patient study, we choose a 3 phase bone scan patient who had a hand disease, because scatter rays from body would detect on crystal. After acquiring blood flow and blood pool images, we analyzed images and spectrums. Additional, we put a lead gown on patient's hand, body. And then we compared and evaluated 3 type blood pool images (non lead gown, lead gown on a hand and on body). Results In case of phantom study, scatter ray counts at backside ($270^{\circ}-90^{\circ}$) are same with a background count. By the way, counts of scatter ray of oblique side ($0^{\circ}-50^{\circ}$, $220^{\circ}-270^{\circ}$) are 100-600 cps, furthermore, counts at frontside are over 4 Mcps. In case of patient study, a counts of hand blood pool scan are 1510 cps. But counts of hand with lead gown on hands and on body are each 1554 cps, 1299 cps. Conclusion Therefore, even though there is a collimator in front of detector, lateral scatter rays detect on crystal and affect to images and spectrums. Especially, if there is a high activity source at outside of detector when we examine low activity organs like hands or foot, we have to shield and remove the source at outside for a good image.

Interspecific Competition of Paddy Rice Isogenic Lines in Plant Type with Some Perennial Weeds (수도초형(水稻草型)의 Isogenic Line과 다년생(多年生) 잡초(雜草)의 경합특성(競合特性) 연구(硏究))

  • Kim, I.K.;Guh, J.O.;Kwon, S.L.
    • Korean Journal of Weed Science
    • /
    • v.3 no.1
    • /
    • pp.39-49
    • /
    • 1983
  • By use of three paddy rice lines as the near-isogenic in plant type (Broom, Open, and Spread type in tillering angle), the interspecific competition patterns of rice plants with three important weed species (Cyperus serotinus, Eleocharis kuroguwai, and Potamogeton distinctus) under the three densities of weed standing (0.25 and 50 percent of the rice plants), were observed. Under the experimented conditions, paddy yields were varied more significantly with weed competition descriptions than with plant types of paddy rice. And spread typed rice was more competitive to the detected weed species, however, the broom and spread typed rice were to Potamogeton SP, among others. The result of the clustering analysis of crop-weed competition patterns, estimated by 1-Q mode correlation coefficients, indicated that the first-order component affecting the competition patterns of crop-weed was rather the plant types of rice than either weed species or weed standing densities.

  • PDF

Femoral Tunnel Obliquity between the Transtibial and Anteromedial Portal Technique in Single Bundle Anterior Cruciate Ligament Reconstruction (전방십자인대 단일 다발 재건술에서 경경골 술기 및 전내측 삽입구를 이용한 대퇴골 터널의 기울기)

  • Lee, Ju-Hong;Park, Jong-Hyuk;Bae, Hyeon-Kyeong;Kim, Jong-Gil;Wang, Sung-Il
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.9 no.1
    • /
    • pp.41-47
    • /
    • 2010
  • Purpose: To compare the obliquity of femoral tunnels prepared with transtibial (TT) versus anteromedial portal technique (AM) using x-ray in single-bundle anterior cruciate ligament (ACL) reconstruction. Materials and Methods: Among one-hundred thirty two patients who were undergoing ACL reconstruction from January 2007 to December 2009, thirty patients using TT and twenty patients using AM, those who had single-bundle ACL reconstruction, were evaluated with plain radiographs including anteroposterior, intercondylar notch and lateral view to compare the obliquity of bone tunnels. Results: The mean coronal obliquity of femoral tunnel for TT was $71^{\circ}$ (range; $65^{\circ}{\sim}77^{\circ}$), while for AM was $51^{\circ}$ (range; $39^{\circ}{\sim}60^{\circ}$) and the mean sagittal obliquity of femoral tunnel for TT was $22.7^{\circ}{\pm}7.8$, while for AM was $30.2^{\circ}{\pm}6.9$, their differences between them were statistically significant (P<0.05). However, there were no differences between two techniques on the tibial tunnel obliquity in coronal and sagittal plane. Conclusion: Anterior cruciate ligament reconstruction using AM portal technique allows more horizontally oriented and divergent femoral tunnel compared to that of transtibial technique. This seems to enable the graft placement into the femoral footprint and preserve the posterior cortical wall.

  • PDF

Projection-type Fast Spin Echo Imaging (프로젝션 타입 고속 스핀 에코 영상)

  • 김휴정;김치영;김상묵;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.42-51
    • /
    • 2000
  • Purpose: Projection-type Fast Spin Echo (PFSE) imaging is robust to patient motion or flow related artifact compared to conventional Fast Spin Echo (FSE) imaging, however, it has difficulty in controlling $T_2$ contrast. In this paper, Tz contrast in the PFSE method is analyzed and compared with those of the FSE method with various effective echo times by computer simulation. The contrasts in the FSE and PFSE methods are also compared by experiments with volunteers. From the analysis and simulation, it is shown that ${T_2}-weighted$ images can well be obtained by the PFSE method proposed. Materials and methods: Pulse sequence for the PFSE method is implemented at a 1.0 Tesla whole body MRI system and $T_2$ contrasts in the PFSE and FSE methods are analyzed by computer simulation and experiment with volunteers. For the simulation, a mathematical phantom composed of various $T_2$ values is devised and $T_2$ contrast in the reconstructed image by the PFSE is compared to those by the FSE method with various effective echo times. Multi-slice ${T_2}-weighted$ head images of the volunteers obtained by the PFSE method are also shown in comparison with those by the FSE method at a 1.0 Tesla whole body MRI system. Results: From the analysis, $T_2$ contrast by the PFSE method appears similar to those by the FSE method with the effective echo time in a range of SO-lOOms. Using a mathematical phantom, contrast in the PFSE image appears close to that by the FSE method with the effective echo time of 96ms. From experiment with volunteers, multi-slice $T_2-weighted$ images are obtained by the PFSE method having contrast similar to that of the FSE method with the effective echo time of 96ms. Reconstructed images by the PFSE method show less motion related artifact compared to those by the FSE method. Conclusion: The projection-type FSE imaging acquires multiple radial lines with different angles in polar coordinate in k space using multiple spin echoes. The PFSE method is robust to patient motion or flow, however, it has difficulty in controlling $T_2$ contrast compared to the FSE method. In this paper, it is shown that the PFSE method provides good $T_2$ contrast (${T_2}-weighted$ images) similar to the FSE method by both computer simulation and experiments with volunteers.

  • PDF

Biomechanical and Physiological Comparative Analysis of the Single-Radius Knee Arthroplasty Systems and Multi-Radius Knee Arthroplasty Systems (무릎인공관절 단축범위(Single-Radius) 수술자와 다축범위(Multi-Radius) 수술자의 운동역 학적 및 운동생리학적 비교분석)

  • Jin, Young-Wan;Kwak, Yi-Sub
    • Journal of Life Science
    • /
    • v.18 no.11
    • /
    • pp.1532-1537
    • /
    • 2008
  • The purpose of this study was to investigate the effect of different arthroplasty designs on knee kinematic and lower limb muscular activation for up-stair and down-stair movement. 3-D video analysis of whole body and joint kinematics and EMG analysis of quadriceps and hamstrings were conducted. One-way ANOVAs were used for statistical analyses (p=0.05). The single-radius group exhibited more arthroplasty limb quadriceps EMG and hamstring coactivation EMG than the multi-radius group. Single-radius demonstrated more abduction angular displacement and reached peak abduction earlier than the multi-radius arthroplasty limb. The single- radius the percent body fat showed similar values in the Elderly, Single and Multi-radius group among the periods, however Control group was Lowered among the periods. Single-radius group limb also increased the quadriceps muscle activation level to produce more knee extension moment to compensate for the short quadriceps moment arm. Resting metabolic rate was significantly increased in control group in the period of LI. Energy expenditure was extremely increased in all groups except control group among the periods. We can say this is the exercise effects.

Petrological Study on the Spherulitic Rhyolite in the Jangsan Area, Busan (부산 장산 지역의 구과상(球課狀) 유문암에 대한 암석학적 연구)

  • Park, Sumi;Yun, Sung-Hyo
    • The Journal of the Petrological Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.219-233
    • /
    • 2013
  • Spherulitic rhyolite occur as part of ring dyke which showing a vertical flowage of $60^{\circ}{\sim}90^{\circ}$, of the Jangsan cauldron was studied. The spherulites range in diameter from a few millimeters to 2.8 centimeters or more, and average 5~10 millimeters. It belongs to radiated simple spherulite type. They consist of a core of moderate brown dense material encased by a thin crust, a few millimeters thick at most of white grey material. The spherulites frequently have a radiating fibrous structure, which are thought to have formed as a consequence of rapid mineral growth caused by very fast cooling of the dykes in shallow depth near the surface. EPMA examination of the concentric-zoned core of spherulites show that they are mainly composed of cryptocrystalline-fibrous intergrowth of silica minerals and alkali feldspars which have $SiO_2$ 82% or more, $Al_2O_3$ 7~10%, $Na_2O+K_2O$ less than 8%. The feldspar compositions of the spherulites lie essentially within the sanidine field. XRD examination show that spherulites are mainly composed of quartz, sanidine, albite with minor mica, kaolinite and chlorite. According to X-ray mapping, the spherulites are enriched in $SiO_2$ in the core and partly enriched $Na_2O$ or $K_2O$, $Al_2O_3$ in the shell that reflect in compositional zoning with increasing spherulitic devitrification. The feathery and non-equant crystal shapes of spherulites from rhyolite dyke of Jangsan cauldron suggest that they may have formed during the rapid cooling of dyke under the static state, or faster velocity of devitrification from glassy materials than movement velocity of the magma intrusion. The spherulitic rhyolite originated from high-silica(75.4~75.7 wt.%) rhyolite magma.

Performance Evaluation of Breast Specific Gamma Imaging (Breast Specific Gamma Imaging 장비의 성능평가)

  • Cha, Eun-Sun;Kwak, In-Suk;Noh, Ik-Sang;Yeon, Joon-Ho;Kim, Ki;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.24-27
    • /
    • 2010
  • Purpose: Early diagnosis of breast is of the utmost importance to improve prognosis. We have a limitation for mammography and sonography detecting small cancer. Clinical importance of Breast Specific Gamma Imaging (BSGI) has improved for that reason. So We studied performance evaluation test of count rate and resolution with high sensitivity to the low dose of BSGI. Materials and Methods: BSGI of Dilon 6800, point source of $^{99m}Tc$ from 1.85~148 MBq (0.05~4 mCi) at the intervals of 1.85~37 MBq (0.05~1 mCi) was used for the test. Performance evaluation method was performed for measuring deadtime for choosing at the 5 different point in the useful field of view (UFOV), acquired image for 60 seconds. Compared with reference of clinical uptake distribution of breast, activity increased according to the distance change 10, 20, 30, 40, 50 mm in the useful field of view. Results: Counting curve increased according to the activity from 1.85 MBq (0.05 mCi) to the 74 MBq (2 mCi), and it change flat shape over 74 MBq (2 mCi). The variation of the full width of half maximum (FWHM) to the distance is 4.05, 4.73, 5.77, 6.90, 8.00, 9.32 mm in 1.85 MBq (0.05 mCi), 4.30, 4.80, 5.90, 7.00, 8.10, 9.07 mm in 3.7 MBq (0.1 mCi), 4.90, 5.60, 6.20, 7.20, 8.20, 9.10 mm in 5.55 MBq (0.15 mCi), 5.30, 6.10, 6.60, 7.00, 7.90, 8.70 mm in 7.40 MBq (0.2 mCi). Conclusion: Distortions of image would be acquired because of the deadtime in BSGI. We found out the fact that specification of $^{99m}Tc$ reaction under 74 MBq (2 mCi) for BSGI. Second, FWHM distribution change from varied distance from the detector, clearly distinguished the location of the lesion.

  • PDF

The influence of Collar design on peri-implant marginal bone tissue (Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향)

  • Kim, Jee-Hwan;Jung, Moon-Kyou;Moon, Hong-Suk;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Statement of problem: Peri-implant marginal bone loss is an important factor that affects the success of implants in esthetics and function. Various efforts have been made to reduce this bone loss by improving implant design and surface texture. Previous studies have shown that early marginal bone loss is affected by implant neck designs. Purpose: The purpose of this study was to examine the influence of laser microtexturing of implant collar on peri-implant marginal bone loss. Materials and methods: Radiographical marginal bone loss was examined in patients treated with implant-supported fixed partial dentures. Marginal bone level was examined with 101 implant fixtures installed in 53 patients at three periods(at the time of implantation, prosthetic treatment and 6-month after loading). Four types of implants were examined. The differences of bone loss between implants(ITI standard) with enough biologic width and implants(ITI esthetic plus, Silhouette IC, Silhouette IC Laser-$Lok^{TM}$) with insufficient biologic width have been compared. Resorption angles were examined at the time of prosthetic delivery and 6-month after loading. Results and Conclusion: Within the limitation of this study, the following results were drawn. 1. The marginal bone loss of ITI standard and Silhouette IC Laser-$Lok^{TM}$ was less than that of ITI esthetic plus and Silhouette IC(P<0.05). The marginal bone loss between ITI standard and Silhouette IC Laser-$Lok^{TM}$ had no significant statistical difference(P>0.05). There was no significant statistical difference between marginal bone loss of ITI esthetic plus and Silhouette IC(P>0.05). 2. There was no significant difference in marginal bone loss between maxilla and mandible(P>0.05). 3. There was no significant difference in resorption angle among four types of implants(P>0.05). The marginal bone of implants with supracrestal collar design of less than that of biologic width had resorbed more than those with sufficient collar length. The roughness and laser microtexturing of implant neck seem to affect these results. If an implant with collar length of biologic width, exposure of fixture is a possible complication especially in the anterior regions of dentition that demand high esthetics. Short smooth neck implant are often recommended in these areas which may lack the distance between microgap and the marginal bone level. In these cases, the preservation of marginal bone must be put into consideration. From the result of this study, it may be concluded that laser microtexturing of implant neck is helpful in the preservation of marginal bone.

Design and Fabrication for the Development of Auto Pattern Maker (자동취형기 개발을 위한 설계 및 제작)

  • Lee, Young-Il;Kim, Jung-Hee;Park, Jee-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.231-239
    • /
    • 2013
  • Purpose: To design and fabricate the auto pattern maker for the development. Methods: we got the necessary data, needed in design, by using CAD. Based on the these data, we fabricated the trial product for the development of the auto pattern maker. Results: The auto pattern maker were composed with combinations of many elements; pattern making assembly, control panel, frame attachment and prober unit. The pattern making assembly was comprised of the cutter, the pattern holder, pattern remover and silence cover which could minimize the sound during the cutting process. The control panel was designed to be connected and operated with the main printed circuit board. The prober could get the eye shape data by scanning of 1.8 degrees around the groove of the frame through the encoding data according to the address. After starting, scanning was carried out in two passes, i.e. one right-handed and one left-handed. Communication connector could send the eye shape data from auto pattern maker to outer system with the RS232C transmission system. By using the one-way analysis of variance, we got the error rate of cut pattern size for ${\Phi}22mm$, ${\Phi}55mm$ and ${\Phi}62mm$. Because F-value was 0.510 and p-value was 0.601, no statistically significant differences were found. Also, the mean cutting error of the auto pattern maker was 0.0274 mm. Conclusions: we could succeed in making the trial product by applying it to the development of the auto pattern maker. The role of this auto pattern maker is to find a exact required size of lens to fit the frame by measuring the frame. The acquired data are transferred to outer system for grinding and finishing with patternless process. Also, the trial product can produce pattern to fit the frame. Therefore, it was confidently expected that the optometrists could handily produce pattern to fit the frame with this trial product and dispense the ophthalmic lens because of its efficiency and convenience compared to the past.