• Title/Summary/Keyword: 충격 저감

검색결과 255건 처리시간 0.034초

An Experimental Study on the Propagation Characteristics of the Impulse Noise from the Exit of a Perforated Pipe (다공관 출구로부터 방사된 충격성 소음의 전파특성에 관한 실험적 연구)

  • Heo, Sung-Wook;Lee, Myeong-Ho;Lee, Dong-Hoon;Hwang, Yoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • 제7권3호
    • /
    • pp.15-21
    • /
    • 2003
  • This experimental study describes the propagation characteristics of the impulse noise emitted from the exit of a perforated pipe attached to the open end of a simple shock tube facility. The pressure amplitudes and directivities of the impulse wave propagating outside from the exit of pipe with several different configurations are measured and analyzed for the range of the incident weak shock wave Mach number between 1.02 and 1.2. In the experiments. the impulse waves are visualized by a Schlieren optical system for the purpose of understanding their propagation characteristics. The results obtained show that for the near sound field the impulse noise strongly propagates toward the pipe axis, but for the far sound field the impulse noise uniformly propagates toward the omnidirections, indicating that the directivity pattern is almost same regardless of the pipe type. For this non-directivity in the far sound field, it is shown that the perforated pipe has little performance to suppress the impulse noise.

Standardization Activity of ISO/TC 43/SC 2/WG 22 Measurement of impact sound improvement of light-weight floors (ISO 140-11(경량 바닥구조의 바닥충격음 저감량 실험실 측정방법)의 제정동향)

  • 장길수;정광용;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1132-1137
    • /
    • 2002
  • 최근 국내에서는 바닥충격음에 대한 측정방법이 개정(2001년 6월 19일자 기술표준원 고시 제2001-334호)되어 KS F 2810-1(바닥충격음 차단성능 현장 측정방법 1부- 표준중량충격원에 의한 방법)과 KS F 2810-2(바닥충격음 차단성능 현장 측정방법 2부- 표준중량충격원에 의한 방법)의 체계가 구축되었다. 이는 현장 측정방법으로서 완성된 건축물에 대한 공간성능을 측정하는 의미를 가지고 있다.(중략)

  • PDF

Characteristics of Floor Impact Noise Insulation for No Hanger Ceiling Structure in Apartment Building (공동주택 무달대 천장의 바닥충격음 차단 특성)

  • Park, Hong-Gun;Mun, Dae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.208-213
    • /
    • 2014
  • 공동주택의 천장구조는 바닥충격음을 변화시키는 영향요소중의 하나이다. 천장구조의 진동응답 특성이 바닥충격음에 영향을 주는 요소를 확인하기 위해 천장구조의 달대를 제거하여 콘크리트 슬래브의 진동이 천장구조에 전달되지 않는 무달대 천장구조를 개발하였다. 달대가 시공된 일반 천장구조와 대비하여 무달대 천장구조의 천장판 가속도와 바닥충격음 레벨을 비교하였다. 무달대 천장구조를 사용함으로서 콘크리트 슬래브의 진동이 천장구조에 전달되는 것을 절연되어 천장구조의 진동응답 증폭을 저감시킬 수 있었으며, 저주파 대역의 바닥 충격음 증폭 또한 저감시킬 수 있었다. 일반 천장구조는 100 Hz 이하에서 천장구조의 진동응답이 증폭되어 저주파 대역 바닥충격음이 증폭되었다.

  • PDF

Research on simple measurement method of floor finishing materials to predict lightweight floor impact noise reduction performance in apartment houses (공동주택 경량 바닥충격음 저감성능 예측을 위한 바닥마감재 간이측정 방법 연구)

  • Min-Woo Kang;Yang-Ki Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • 제42권6호
    • /
    • pp.594-602
    • /
    • 2023
  • To date, research on heavy floor impact noise has mainly been conducted. The reason is that in the case of lightweight floor impact noise, sufficient performance could be secured with only the floating floor structure and floor finishing materials. In the case of heavy floor impact noise in a floating floor structure, the reduction performance can be predicted to some extent by measuring the dynamic elasticity of the floor cushioning material. However, with the recent introduction of the post-measurement system, various floor structures are being developed. In particular, many non-floating floor structures that do not use cushioning materials are being developed. In floor structures where cushioning materials are not used, the finishing material will have a significant impact on lightweight floor impact noise. However, research on floor finishing materials is currently lacking. In this study, as a basic research on the development of various floor finishing materials for effective reduction of lightweight floor impact noise, various materials used as floor finishing materials for apartment complexes were selected, the sound insulation performance of lightweight floor impact noise was measured in an actual laboratory, and vibration characteristics were identified through simple experiments. The purpose was to confirm the predictability of light floor impact noise.

Performance Evaluation of Shock, Vibration and Structure-borne Noise for Double-resilient Mounting Engine Module (이중탄성지지 함정용주기관의 충격, 진동 및 고체음 성능평가)

  • 유광택;박정근;정정훈;김병현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.1048-1052
    • /
    • 1996
  • 함정용 주기관은 내충격 및 고체음 저감을 위하여 이중탄성지지시스템으로 설치되고 있다. 이중탄성지 지에 의한 방법은 기뢰(mines)의 비접촉 수중폭발 공격으로부터 충격손상을 방지하며, 또한 수중으로 고체음이 전파되어 피탐되는 가능성을 저감하는데 그 목적이 있다.(중략)

  • PDF

A Study on Impact Sound Insulation Properties of EPDM Micro Cellular Pad (에틸렌-프로필렌-디엔 삼원 공중합 (EPDM) 발포체의 충격음 저감 특성에 관한 연구)

  • Lee, Kyung-Won;Lee, Jung-Hee;Sohn, Ho-Soung
    • Elastomers and Composites
    • /
    • 제35권2호
    • /
    • pp.138-148
    • /
    • 2000
  • In order to investigate the possibility of EPDM micro cellular pad (MCP) as an impact sound insulation product, we studied static/dynamic properties and vibration transfer characteristics of EPDM MCP depending on shape, thickness, degrees of foaming by using material test system (MTS) and lab scale mock-up test apparatus. Static/dynamic rigidity is increased when shape is simple. thickness and degrees of foaming low. We could see that dynamic stiffness is proportional to the transmissibility of EPDM MCP. When dynamic stiffness is increased, characteristic peak at transmissibility curve moves high frequency range or snows increase of maximum value of transmissibility. For lab scale mock-up test and finite element method, EPDM MCP shows low vibration velocity and superior mode shape to just concrete plus slab structure. We could confirm that possibility of EPDM MCP as a impact sound insulation product is high.

  • PDF

Effects of sound absorbent gypsum board in the ceiling on low-frequency heavyweight floor impact sound (흡음 석고보드 천장재에 의한 저주파 중량 바닥충격음의 저감 효과)

  • Song, Han-Sol;Ryu, Jong-Kwan
    • The Journal of the Acoustical Society of Korea
    • /
    • 제37권5호
    • /
    • pp.323-330
    • /
    • 2018
  • This study investigated effects of absorbent gypsum board in the ceiling on low-frequency heavyweight floor impact sound through sound absorption coefficient and floor impact sound measurement. The sound absorption coefficients were measured with sound absorbent gypsum board, glass wool on gypsum board, and a double panel absorbent gypsum board (absorbent gypsum board + glass wool + absorbent gypsum board). Result showed that the absorbent gypsum board had sound absorption coefficient of 0.1 ~ 0.7 from 200 and 630 Hz octave band. The sound absorption coefficient was increased in all frequency range by adding glass wool. Additional absorbent gypsum board increased sound absorption coefficient up to 250 Hz octave band, but decreased over 250 Hz. Heavyweight floor impact sounds were measured in test building for three materials above, gypsum board, and bare slab. Result showed that glass wool on gypsum board and a double panel absorbent gypsum board reduced by 3 dB ~ 4 dB (single number quantity) heavyweight floor impact sound. Comparing with bare slab condition, floor impact sound reduction was mainly found from 125 Hz to 500 Hz octave band, and the maximum reduction was shown in the 250 Hz octave band.

Investigation of the level difference of floor impact noises through the shape variation of EVA resilient materials with composite floor structure (EVA 완충재의 형상변환을 통한 복합구조의 바닥충격음 변이 조사)

  • Jakin Lee;Seung-Min Lee;Chan-Hoon Haan
    • The Journal of the Acoustical Society of Korea
    • /
    • 제43권1호
    • /
    • pp.60-71
    • /
    • 2024
  • The present study aims to investigate the level difference of floor impact noises of composite floor structure using EVA resilient materials. In order to this, four different types of resilient materials were designed combining PET, PP sheet and EVA mount including Flat type, Deck type, Cavity type and Mount type. Totally 9 different samples were made for acoustic measurements which were carried out twice with bang-machine and impact ball as the heavy-weight floor impact noise sources. All the floor impact noise measurements were undertaken at the authentication institution. As a result, concerning Flat and Cavity types, it was found that 2 dB ~ 5 dB of heavy-weight floor impact noise was reduced supplementally when PET was added, while floor impact noise larger than 50 dB was acquired when single resilient material was used. Especially, most high performance was obtained for Mount type with 1st grade of light-weight floor impact noise and 2nd grade of heavy-weight floor impact noise. This is because of material property with low dense PET sound absorption materials which fill all around EVA mounts. Also, it was considered that this results are due to the sound impact absorption by the both EVA mounts and the air cavity between EVA mount and PP sheet. Also, it was found that at least 36 EVA mounts per 1m2 area of resilient panel make more noise reduction of heavy-weight floor impact noises.

Noise and Rooms Acoustic Control in Multi-Purpose Space (다목적 공간의 소음 및 실내음향 제어)

  • Jeong, Jeong-Ho;Kim, Jung-Joong;Cho, Chang-Geun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.42-45
    • /
    • 2008
  • 다목적 공간 및 공연장은 공연 또는 강연을 위한 공간뿐만 아니라 상점, 식당 및 체육 공간 등 다양한 용도의 공간이 인접되고 있다. 다양한 공간이 인접할 경우 기존의 다목적 공연장에서는 발생하지 않았던 다양한 소음 진동 문제들이 발생한다. 본 연구는 강연 및 공연을 위한 다목적 공간 상부에 식당 및 체육 시설로 활용되는 공간이 배치되어 바닥충격음 문제가 발생할 가능성이 있었다. 바닥충격음의 강당으로의 전달을 차단하기 위하여 기본 구조체에 대한 바닥충격음 차단성능을 측정하여 적절한 저감 대책을 수립하였다. 저감대책으로는 상층부 철골 슬래브와 강당의 철골 구조의 구조적 분리, 유연한 마감재 적용, 슬래브로의 충격진동 차단을 위한 제진재 적용, 이중천장 구조 및 천장내부 흡음구조 형성 등의 종합적인 대책을 수립하였다. 이를 통해 경량충격음 및 중량충격음을 효율적으로 차단하였다. 또한 강당 공간은 강연 및 집회의 공간으로 활용될 수 있도록 하기 위하여 적절한 잔향시간 및 음성 명료도 확보가 필요하다. 플러터 에코, 과도한 잔향시간, 음의 사각지대 등을 최소화하기 위하여 측벽 형태 개선, 천장 반사판 형태를 개선하였다. 또한 측벽에서 진동 등의 영향으로 발생되는 떨림현상을 억제하기 위하여 측벽 내부를 흡음재로 충전하는 등의 대책을 수립하여 적용하였다.

  • PDF

A Numerical Experiment For Interference Waves Reduction In Chute Spillways With Contraction (축소부를 고려한 여수로의 충격파 저감 : 수치모의)

  • Hwang, Jong-Hoon;Kim, Dae-Geun;Kim, Chang-Si;Lee, Ji-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1732-1736
    • /
    • 2006
  • 여수로는 월류시 한계류 상태와 고유속의 사류상태가 복합적으로 일어나는 복잡한 흐름형태를 가지고 있어 여수로의 단면설계시 수리적인면뿐만 아니라 구조적인 측면에서도 안정해야 하며 경제성이 고려되어야 한다. 그래서 고유속의 흐름을 갖는 여수로에 축소부를 고려할 경우 충격파에 의한 수위상승과 하류의 흐름 교란 등 수리학적인 불안정이 발생하기 때문에 설계시 경제적인 장점이 있음에도 불구하고 단면축소부를 고려하여 여수로를 설계하는 것은 현실적으로 많은 어려움이 있다. 본 연구에서는 단면축소를 고려한 여수로 설계를 위하여 3차원 수치모형인 Flow-3D를 이용하여 충격파로 인하여 발생하는 교차파 저감을 모의하기 위하여 수치실험을 실시하였다. 교차파 저감을 위해 축소부내에서 교차파가 발생하도록 축소부의 각도는 유입흐름 특성을 고려하여 적정하게 설정하였다. 수치실험결과 축소부의 각도가 작을수록 첫번째 교차파의 수위는 크게 발생하지 않으나 단면축소후 교차파가 하류로 전파되어 불안정한 흐름이 연속적으로 발생하고, 과대하게 설정할 경우 첫번째 발생하는 교차파에 의해 중앙부의 수위가 크게 상승하는 결과를 보였다. 또한 본 연구에서는 축소부단면내 회절판(diffractor) 설치전 후의 수리학적 거동을 모의하여 회절판의 흐름개선 효과를 검증하였다.

  • PDF