• Title/Summary/Keyword: 출력비율

Search Result 264, Processing Time 0.034 seconds

A Study of the Output Characteristics of a 1-kW-class Narrow-bandwidth PM Fiber Laser Depending on Its Pumping Structure (펌핑 구조에 따른 1 kW급 협대역 편광 유지 광섬유 레이저의 출력 특성 연구)

  • Kim, Tae Hyoung;Jeong, Seong Mook;Kim, Ki Hyuck;Lee, Sung Hun;Yang, Hwan Seok
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.4
    • /
    • pp.187-194
    • /
    • 2021
  • This paper presents a study of laser output characteristics. We fabricated a MOPA (master oscillator power amplifier)-type high-power, narrowbandwidth fiber laser with a bidirectional pumping configuration in its main amplifier. As signal beams, light sources with bandwidths of 3 GHz and 10 GHz-phase-modulated through a PRBS (pseudo-random binary sequence)-were used interchangeably. Furthermore, the characteristics of the SBS (stimulated Brillouin scattering) were analyzed using a signal beam with 3 GHz bandwidth, by adjusting the forward to backward pumppower ratio. Moreover, the characteristics of the transverse mode instability were analyzed by adjusting the forward to backward pump-power ratio, using a signal beam with 10-GHz bandwidth. Finally, the output power from 10 GHz bandwidth was amplified to more than 1 kW using a forward to backward pump-power ratio of 1.6. The beam quality M2 was measured to be approximately 1.36, and the optical-to-optical efficiency was 80% at maximum output power.

고전압 펄스 시스템 '천둥'을 이용한 N2, SF6 혼합기체에서의 전기.광학적 분석

  • Byeon, Yong-Seong;Song, Gi-Baek;Hong, Yeong-Jun;Lee, Seung-Hui;Eom, Hwan-Seop;Choe, Deok-In;Ryu, Han-Yong;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.221-221
    • /
    • 2011
  • 수 Tera Watt급의 가속기 및 펄스파워 시스템은 다수의 스위치를 사용하고 있으며, 이와 같은 가속기 및 시스템의 성능은 기체방전 스위치의 성능에 직접적으로 관련되어 있다. 일반적으로 이와 같은 기체방전, 액체방전 고출력 스위치는 다목적으로 많은 연구와 개발에 응용되고 있다. 예를 들어 천둥 펄스전자빔 발생장치는 12개의 Marx gap 및 3개의 100 kV 펄스충전 전기트리거 gap을 가지고 있다. 기체 방전 또는 액체 방전 펄스 충전 갭 스위치의 음극에 펄스 고전압이 인가되면 이로 인하여 음극에서 전자빔이 발생한다. 내부에는 전자빔이 양극과 충돌하는 순간 양극표면에 플라스마가 형성된다. 이와 같은 플라스마 sheath는 축 방향 이극관 안에서 양극 충전 에서 음극으로 팽창하면서 전파하며, 또한 거의 동시에 음극표면에도 플라스마가 형성되어 음극에서 양극으로도 팽창하여 전파하게 된다. 이와 같은 펄스충전 고출력 갭 스위치 안에서 발생되는 방전 플라스마의 특성에 관한 갭 breakdown 과정에 대한 특성연구를 한다. 고출력 스위치의 특성 조건으로는 방전전압, 방전시간, jitter 등이 있다. 본 연구에서는 최대전압 600 KV, 최대전류 88 KA, 펄스 폭 60 ns의 특성을 가지는 고전압 펄스 시스템 '천둥'을 이용하여 방전 챔버에 고전압 펄스를 인가하고 N2와 SF6 혼합기체 종류와 압력에 따른 현상을 전기, 광학적으로 연구하였다. 전극은 구리텅스텐 합금재질의 표준전극을 사용하였고, 전극 간격은 20 mm로 고정하였다. 방전 챔버 압력을 100 torr에서 4 기압까지 변화시켜가며 실험을 진행하였고, N2에 대한 SF6의 혼합비율을 0%~100%까지 변화시키며 실험을 진행하였다. 실험결과 방전전압은 압력이 증가함에 따라 증가하다가 2 기압 이상에서는 완만히 증가하는 경향을 보였고, SF6 혼합비율은 0~10%까지 급격히 증가하고, 그 이상의 혼합비율에서는 완만히 증가하였다. 전자온도는 SF6 혼합비율이 0~10%일 때 급격히 증가하여 이후에는 포화되는 경향을 보였고, 압력에 따라서는 큰 경향성을 보이지 않았다.

  • PDF

고전압 펄스 시스템 '천둥'을 이용한 N2, SF6 및 혼합기체에서의 전기 방전 현상 연구

  • Byeon, Yong-Seong;Song, Gi-Baek;Hong, Yeong-Jun;Han, Yong-Gyu;Eom, Hwan-Seop;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.102-102
    • /
    • 2010
  • 수 Tera Watt급의 가속기 및 펄스파워 시스템은 다수의 스위치를 사용하고 있으며, 이와 같은 가속기 및 시스템의 성능은 기체방전 스위치의 성능에 직접적으로 관련되어 있다. 일반적으로 이와 같은 기체방전, 액체방전 고출력 스위치는 다목적으로 많은 연구와 개발에 응용되고 있다. 예를 들어 천둥 펄스전자빔 발생장치는 12개의 Marx gap 및 3개의 100 kV 펄스충전 전기트리거 gap을 가지고 있다. 기체 방전 또는 액체 방전 펄스 충전 갭 스위치의 음극에 펄스 고전압이 인가되면 이로 인하여 음극에서 전자빔이 발생한다. 내부에는 전자빔이 양극과 충돌하는 순간 양극표면에 플라스마가 형성된다. 이와 같은 플라스마 sheath는 축 방향 이극관 안에서 양극충전 에서 음극으로 팽창하면서 전파하며, 또한 거의 동시에 음극표면에도 플라스마가 형성되어 음극에서 양극으로도 팽창하여 전파하게 된다. 이와 같은 펄스충전 고출력 갭 스위치 안에서 발생되는 방전 플라스마의 특성에 관한 갭 breakdown 과정에 대한 특성연구를 한다. 고출력스위치의 특성 조건으로는 방전전압, 방전시간, jitter 등이 있다. 본 연구에서는 최대전압 600 KV, 최대전류 88 KA, 펄스 폭 60 ns의 특성을 가지는 고전압펄스 시스템 '천둥'을 이용하여 방전 챔버에 고전압 펄스를 인가하고 N2와 SF6 혼합기체 종류와 압력에 따른 방전 현상을 연구하였다. 전극은 구리텅스텐 합금재질의 표준전극을 사용하였고, 전극 간격은 20 mm로 고정하였다. 방전 챔버 압력을 100 torr에서 4 기압까지 변화시켜가며 실험을 진행하였고, N2에 대한 SF6의 혼합비율을 0%~100%까지 변화시키며 실험을 진행하였다. 방전 챔버에는 C-dot probe와 B-dot probe를 설치하여 전압과 전류를 측정하였고, C-dot probe 와 B-dot probe는 각각 Northstar사의 10000:1 고전압 probe와 rogowiski coil을 이용하여 시준 하였다. 실험결과 방전전압은 압력이 증가함에 따라 증가하다가 2 기압 이상에서는 완만히 증가하는 경향을 보였고, SF6 혼합비율은 0~10%까지 급격히 증가하고, 그 이상의 혼합비율에서는 완만히 증가하였다. 방전개시시간은 혼합기체 압력에 따라 증가하며 1기압 이상에서는 급격히 증가 하였다. SF6 혼합비율에 따라서는 1 기압 조건까지는 큰 차이가 없었으나 2 기압부터는 급격히 증가하였다. 안정성을 나타내는 jitter는 SF6 100%일 때 가장 컸으나 혼합기체의 변화에 따른 큰 차이는 없었다.

  • PDF

The preparation and characteristics of the AIN thin film by the rative sputtering method (반응성 스퍼터링 방법에 의한 AIN 박막의 제작과 특성)

  • 정성훈;송복식;홍필영;문동찬;김선태
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.23-26
    • /
    • 1996
  • 고주파 스퍼터링 방법에 의하여 상온에서 Si(100)기판 위에 AIN막을 형성하였다. 기판의 온도, 고주파 출력, 스퍼터링 시간, 질소의 비율을 변화인자로 해서 각 조건하에서 제작된 AIN의 결정질을 X선 회절법, 적외선 분광법, 전자현미경으로 상호비교 하였다. 자외선 투과법에 의해, 제작된 AIN 막의 금지대 폭은 4.27eV 이었다. 질소 비율에 따른 AIN 막두께의 변화는 질소비율 40∼60%에서 급격하게 일어났다.

  • PDF

The variable power divider circuit to use the ring-hybrid coupler (링-하이브리드 커플러를 이용한 가변 전력 분배기 회로)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.253-259
    • /
    • 2016
  • This paper introduces a new variable power divider circuit with an arbitrary power division ratio ranging from $1:{\infty}$ to ${\infty}:1$. The proposed power divider circuit consists of one branch-line coupler to be a good input matching characteristic, two variable phase shifters with 90-degree phase variation to be connected two output paths of the branch-line coupler, and one ring-hybrid coupler to combine output signals of two variable phase shifter. The power division ratio between the two output ports of the proposed power divider can be easily controlled by the phase variation of the two phase shifter. The proposed power divider circuit fabricates on laminated RF-35 (h = 20 mil, er=3.5; Taconic) with a center frequency of 2 GHz. The power division ratio of the fabricated prototype varies from about 1:1000 to 5000000:1, with an input reflection characteristic(S11) of below -20 dB, an insertion loss of about -1.0 dB, and an isolation characteristic of below -17 dB between two output ports in the range 1.9-2.1 GHz.

Reactor Control Method for Load Follow Operation of KNGR (KNGR의 부하추종 운전 제어)

  • Kim, Yong-Hee;Cha, Kune-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.600-602
    • /
    • 1999
  • 원자력발전 비율이 증가함에 따라 전기에너지의 효율적인 이용과 원자력발전의 경쟁력 제고를 위하여 원자력발전소(이하 원전)의 부하추종운전 필요성이 점점 커지고 있다. G7과제의 하나로 개발되고 있는 차세대원자로(KNGR, Korean Next Generation Reactor)는 경쟁력 있는 원전의 설계를 위하여 "일일부하추종운전 능력의 확보"를 기본 성능요건의 하나로 하여 개발되고 있다. 그러나 수동으로 원자로출력분포를 제어하는 기존 원전의 제어방식으로는 상기목표를 충족시키기 어려워 원자로의 출력분포와 출력을 동시에 제어하는 새로운 자동 제어방식을 도입하였다. 본 논문에 기술된 제어방법은 원자로 출력분포 상태에 따른 비선형 제어방법이 적용되며 목표출력 부근에서의 Oscillatory Behavior 방지를 위해 설정된 Deadband 내에서의 다른 상태변수를 제어하기 위한 알고리즘도 포함된다. 개발된 제어방법의 성능을 확인하기 위해 원자로 증기공급계통 전체를 모델링한 성능분석 Simulator를 이용한 Numerical Simulation을 수행하였다. 일일부하추종운전은 100-50-100%P[$(10{\sim}16)-2-(10{\sim}4)-2$ hr] power cycle over a 24-hour period, 주파수제어는 일반적인 Grid Follow에 대해 Simulation하였다.

  • PDF

Detection of M-FSK Signals with Difference Threshold Test in Rayleigh Fading Channels (레일리 감쇄 채널에서 차분 문턱간 검정을 쓴 M진 주파수 편이 변조 신호검파)

  • Kim Hong Jik;Kang Hyun Gu;Kim Sun Yong;Kwon Hyoungmoon;Bang Man-Won;Song Iickho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10C
    • /
    • pp.999-1006
    • /
    • 2005
  • The difference threshold test (DTT) declares erasures whenever the difference between the largest and second largest energy detector outputs does not exceed a given threshold. we show that the DTT outperforms the ratio threshold test (RTT) for finite modulation size and diversity order in the detection of M-FSK signals. The asymptotic performance for infinite modulation size and diversity order is then investigated. It is shown that the minimum signal-to-noise ratio required to achieve error-free communication for the DTT is the same as that for the RTT.

A study on the Quay Capacity at the Container Terminal Using Simulation Model (시뮬레이션 모델을 이용한 컨테이너 터미널 안벽능력 분석)

  • 김창곤;양창호;윤동한;최종희;배종욱
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.05a
    • /
    • pp.43-48
    • /
    • 2001
  • 본 연구에서는 컨테이너 터미널의 적정 안벽능력(Quay Capacity)을 분석하기 위한 시뮬레이션 모델을 구축하였다. 모델에서는 선박의 터미널 도착 특성, 선박별 양하량 및 적하량, 컨테이너 크레인(Container Crane, C/C) 생산성 및 투입대수 등을 입력변수로 입력하였으며, 시뮬레이션 결과로써는 안벽점유율, 선석 점유율, 대기시간 비율, 대기비율, Norm time 초과비율 등을 출력하였다. 이중 컨테이너 터미널의 평가지표로는 Norm time 초과비율, 대기비율 및 안벽점유율을 적용하였다. 컨테이너 터미널을 운영중인 터미널의 터미널 운영실적 자료를 이용하여 모델의 확인 및 검증을 실하였다. 모델은 Knowledge Base에 근거하여 수행되는 G2를 이용하여 구축하였다.

  • PDF

A Numerical Analysis for Optimum Design of Multi-Stage Amplifier System of High Power Dye Laser (고출력 색소 레이저의 다단 증폭 시스템의 최적설계에 관한 수치해석)

  • 고도경
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.281-288
    • /
    • 1993
  • We have investigated the output characteristics and optimal conditions of a multi-stage amplifier system of Rhodamine 6G dye laser. The parameters in this simulation work were the beam diameter of the dye laser oscillator, the size of dye cell, the dye concentration, the number of stages in the amplifier system, and the pumping energy ratio of each amplifier at given pump energy. As a result, the output energy 10 mJ and the conversion efficiency of 40% in the two stage amplifier system were obtained with the pumping energy of 25mJ and the oscillator energy of 0.01 mJ.

  • PDF

Combustion and Emission Characteristics of Utility Boiler burning Anthracite-Bituminous Coal Blends (발전용 보일러에서의 유, 무연탄 혼소시 연소 및 환경특성)

  • Park, Ho-Young;Kim, Young-Joo;Park, Hyun-Joo;Kim, Sung-Chul
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.153-160
    • /
    • 2008
  • The combustion behaviors of the blends of Korean anthracite, bituminous coal and their blends were studied with a thermogravimetric analyzer. Concerning the burning profiles of the anthracite-bituminous coal blends in TGA, it has been observed the independent burning of two coals without any interaction between two coals. With the blends of 50% anthracite with 50% bituminous coal in weight basis, the combustion tests in a utility boiler have been carried out for the analysis of the combustion and operational characteristics by increasing the power output from 134 MW to 197 MW. The stable combustion has been observed in a boiler. With the increase of power output, the exhaust gas temperature was exceeded the design value of $430^{\circ}C$, so the combustion air was taken from atmosphere instead of the boiler penthouse.