• Title/Summary/Keyword: 최대 사후

Search Result 178, Processing Time 0.031 seconds

Comparison of the mechanical properties and microstructures of fractured surface for Co-Cr alloy fabricated by conventional cast, 3-D printing laser-sintered and CAD/CAM milled techniques (주조, 3-D printing을 활용한 laser sintered 및 CAD/CAM milled 기법을 이용하여 제작된 코발트-크롬 합금의 물리적 성질 및 파절 단면 관찰 비교 연구)

  • Choi, Yun-Jung;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun;Ahn, Jin-Soo;Park, Dong-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.67-73
    • /
    • 2014
  • Purpose: The purpose of present study is to compare mechanical properties and microstructural characteristics of fractured surface for cast, 3-D printing laser sintered and CAD/CAM milled cobalt-chromium (Co-Cr) alloy specimens and to investigate whether laser sintered technique is adequate for dental applications. Materials and methods: Thirty six flat disc shape Co-Cr alloy specimens were fabricated for surface hardness test and divided into three groups according to the manufacturing methods; 12 specimens for casting (n=12), 12 specimens for laser sintered technology (n=12) and 12 specimens for milled technology (n=12). Twelve dumbbell shape specimens for each group were also fabricated for a tensile test. Statistical comparisons of the mechanical properties for the alloys were performed by Kruskal-Wallis test followed by Mann-Whitney and Bonferroni test. The microstructural characteristics of fractured surfaces were examined using SEM. Results: There were significant differences in the mean Vickers hardness values between all groups and the cast specimen showed the highest (455.88 Hv) while the CAD/CAM milled specimen showed the lowest (243.40 Hv). Significant differences were found among the three groups for ultimate tensile strength, 0.2% yield stress, elongation, and elastic modulus. The highest ultimate tensile strength value (1442.94 MPa) was shown in the milled group and the highest 0.2% yield strength (1136.15 MPa) was shown in the laser sintered group. Conclusion: Different manufacturing methods influence the mechanical properties and microstructure of the fractured surfaces in Co-Cr alloys. The cast Co-Cr alloy specimens showed the highest Vickers hardness, and the CAD/CAM milled specimens revealed the highest tensile strength value. All alloys represent adequate mechanical properties satisfying the ISO standards of dental alloy.

Monitoring Methylmercury in Abyssal Fish (심해성 어류 중 메틸수은 모니터링)

  • Kim, Seong-Cheol;Jang, Jin-Wook;Kim, Hyun-Ah;Lee, Sang-Ho;Jung, Young-Ji;Kim, Ji-Yeon;Ahn, Jong-Hoon;Park, Eun-Hye;Ko, Yong-Seok;Kim, Dong-Sul;Kim, Sang-Yub;Jang, Young-Mi;Kang, Chan-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.383-389
    • /
    • 2010
  • The aim of this study was to determine the methylmercury (MeHg) levels in abyssal fish species. The MeHg in the fishes was extracted with hydrochloric acid and toluene and then purified using an L-cysteine solution. The extract was analyzed with a gas chromatography-electron capture detector (GC-${\mu}ECD$) with a thermon Hg-capillary column. The detection limit and the recovery of the method were 0.002 and 84.2-98.5% (mean, 93.4%), respectively. The MeHg content in 492 abyssal fishes ranged from 0.037 to 2.009 mg/kg. The levels of MeHg [range, mg/kg (mean)] were significantly dependent on fish species and presented as the following; 0.157-2.009 (0.546) in Scalloped hammerhead shark, 0.211-0.878 (0.501) in Blue shark, 0.121-0.993 (0.482) in Spiny dogfish, 0.243-0.658 (0.397) in Salmon shark, 0.074-1.958 (0.353) in Blacktip shark, 0.038-0.807 (0.302) in Southern hake, 0.099-0.511 (0.300) in Scorpion fish, and 0.037-0.133 (0.067) in Ling. The monitoring results showed that the estimated weekly intake of MeHg from sharks, Southern hake, and Ling were lower than the provisional tolerable weekly intake recommended by the Joint FAO/WHO expert committee on food additives.

Does Sarcopenic Obesity Affect Physical Function and Physical Fitness of Korean Older Women? (근위축비만이 국내 여성고령자의 신체기능과 체력에 미치는 영향)

  • Hong, Seung-youn
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.831-842
    • /
    • 2010
  • BACKGROUND: Sarcopenic obesity(SO), a condition of the reduction in muscle mass paired with an increased fat mass has been paid attention because of its association with disability in later life. A few evidence, however, has reported the association with these factors. PURPOSE: To explore the association among SO, physical function and fitness in older women. METHOD: 257 older women(age of 74) were recruited from Y city and 7 physical functions and 4 fitness tests were measured. Participants were classified into one of four groups based on their body fat and muscle mass: Normal group (GR-A), high fat(GR-B), sarcopenia(GR-C), and sarcopenic obese(GR-D). GLMand LSD-test were conducted with SPSS 12.0. RESULTS: Chair stand, arm-curl, back-scratch, 2-min steps of GR-A was higher than GR-C and GR-D(p<.05). One-leg stand of GR-A was higher than GR-D(p<.01) and of GR-C was higher than GR-D(p<.01).8ft-TUG of GR-D was lower than GR-A(p<.01). Grip strength, knee extension of GR-A was higher than that of GR-C and GR-D(p<.01) and knee flexion of GR-A was also higher than that of GR-C and GR-D(p<.01). CONCLUSION: Based on our findings, we conclude that SO is significantly associated with lower physical function and fitness in older Korean women, which alarm the risk of frailty induced by SO.

The effect of bracket width on frictional force between bracket and arch wire during sliding tooth movement (치아의 활주 이동시 브라켓 폭이 브라켓과 호선 사이의 마찰력에 미치는 효과)

  • Choi, Won-Cheul;Kim, Tae-Woo;Park, Joo-Young;Kwak, Jae-Hyuk;Na, Hyo-Jeong;Park, Du-Nam
    • The korean journal of orthodontics
    • /
    • v.34 no.3 s.104
    • /
    • pp.253-260
    • /
    • 2004
  • Frictional force between the orthodontic bracket and arch wire during sliding tooth movement is related to many factors, such as the size, shape and material of both the bracket and wire, ligation method and the angle formed between the bracket and wire. There have been clear conclusions drawn in regard to most of these factors, but as to the effect of bracket width on frictional force there are only conflicting studies. This study was designed to investigate the effect of bracket width on the amount of frictional forces generated during clinically simulated tooth movement. Three different widths of brackets $(0.018{\times}0.025'\;standard)$ narrow (2.40mm), medium (3.00mm) and wide (4.25mm) were used in tandem with $0.016{\times}0.022'$ stainless steel wire. Three bracket-arch wire combinations were drawn on for 4 minutes on a testing apparatus with a head speed of 0.5mm/min and tested 7 times each. To reproduce biological conditions, dentoalveolar models were designed with indirect technique using a material with similar elastic properties as periodontal ligament (PDL). In addition, to minimize the effect of ligation force, elastomer was used with added resin, which was attached to the bracket to make up for the discrepancies of bracket width. The results were as follows: 1. Maximum frictional force for each bracket-arch wire combination was: Narrow (2.40mm): $68.09\pm4.69gmf$ Medium (3.00mm): $72.75\pm4.98 gmf$ Wide (4.25mm): $72.59\pm4.54gmf$ 2. Frictional force was increased with more displacement of wire through the bracket slot. 3. The ANOVA psot-hoc test showed that the bracker width had no significant effect on frictional force when tested under clinically simulated conditions(p>0.05).

Developing a Model for Crime Prevention Hardware Performance Test and Certification System (방범하드웨어의 침입범죄 저항성능 시험·인증 체계에 관한 모형 연구)

  • Park, Hyeon-ho
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.255-292
    • /
    • 2013
  • Burglary (also called breaking and entering and sometimes housebreaking) is a crime, the essence of which is illegal entry into a building for the purposes of committing an offence. It is one of the most common types of crime and also a serious issue for every society. A house that is left insecure is an accessible and attractive target for burglars and therefore burglary resistance test & certification system for doors and windows has been developed in many countries. This paper explores several advanced foreign burglary resistance test/certifcation cases (the British SBD, the Dutch KOMO SKH/SKG, the Japanese CP mark, the Australian Standard Certification) for security products and domestic test/certification systems for fire safety products as a comparative study so that any improvement points can be gained for South Korea in the field of security product performance. The comparative analysis results show that South Korea is far behind the security product certification system and needs a lot of improvement in the system by benchmarking foreign cases. The domestic test/certification systems for fire safety products also give some insights for burglary-related security products' performance certification system in Korea. Overall, the need for relevant rules and regulations, the establishment of standards regarding testing and certification, including certified security +hardware product in building security certification system, performance testing as well as production testing (i.e. quality management system evaluation), the basic competency of testers, incentive system for certified/high quality security products were suggested in order to make an optimal model for the security production performance testing and certification system in Korea.

  • PDF

Early Changes after Death of Plaice, Paralichthys olivaceus Muscle -5. Effect of Storage Temperature on Morphological Changes of Myofibrils and Histological Changes of Muscle- (넙치(Paralichthys olivaceus)육의 사후 조기 변화 -5. 저장 온도가 근원섬유의 형태학적 및 육의 조직학적인 변화에 미치는 영향-)

  • CHO Young-Je;LEE Keun-Woo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.2
    • /
    • pp.114-120
    • /
    • 1994
  • To clarify the effect of storage temperature on the morphological and histological changes of plaice, Paralichthys olivaceus muscle at early stages after killing, the changes in breaking strength of muscle, morphological observation of myofibrils and histological observation of extracellular spaces during storage at $0^{\circ}C\;and\;10^{\circ}C$ were studied. The maximum breaking strength of samples stored at $0^{\circ}C$ was reached within 10hrs and then it dropped significantly (p<0.05) from 10hrs to 25hrs of storage. However, breaking strength was not increased in fresh muscle stored at $10^{\circ}C$ and gradually decreased after 10hrs storage. In myofibrils prepared from dorsal muscle immediately after death, A-band, I-band, H-band and Z-line in sarcomere were clearly distinguishable from each other. Due to muscle contraction, it was not easy to distinguish H-band from I-band observed in sarcomere stored at $0^{\circ}C$ after 10hrs storage. But, in the case of samples stored at $10^{\circ}C$, H-band could be observed dimly until 15hrs of storage. The changes in morphological myofibrils were closely related to increase of breaking strength. No extracellular space was observed among muscle cells immediately after killing. Stored samples at $0^{\circ}C$ showed extracellular spaces after 15hrs storage. On the other hand, samples stored at $10^{\circ}C$ didn't show any extracellular spaces until 15hrs storage and showed extracellular spaces after 24hrs storage. It was thought that the post-mortem tenderization of plaice muscle was closely related to the gradually disintegration of the extracellular matrix structure after killing.

  • PDF

MICROLEAKAGE OF RESILON: EFFECTS OF SEVERAL SELF-ETCHING PRIMER (Resilon을 이용한 근관충전 시 수종의 치면처리제에 따른 미세누출 평가)

  • O, Jong-Hyeon;Park, Se-Hee;Shin, Hye-Jin;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.133-140
    • /
    • 2008
  • The purpose of this study was to compare the apical micro leakage in root canal filled with Resilon by several self-etching primers and methacrylate-based root canal sealer. Seventy single-rooted human teeth were used in this study. The canals were instrumented by a crown-down manner with Gate-Glidden drills and .04 Taper Profile to ISO #40. The teeth were randomly divided into four experimental groups of 15 teeth each according to root canal filling material and self-etching primers and two control groups (positive and negative) of 5 teeth each as follows: group 1 - gutta percha and $AH26^{(R)}$ sealer: group 2 - Resilon, $RealSeal^{TM}$ primer and $RealSeal^{TM}$ sealer: group 3-Resilon, Clearfil SE $Bond^{(R)}$ primer and $RealSeal^{TM}$ sealer group 4-Resilon, $AdheSe^{(R)}$ primer and $RealSeal^{TM}$ sealer. Apical leakage was measured by a maximum length of linear dye penetration of roots sectioned longitudinally by diamond disk. Statistical analysis was performed using the One-way ANOVA followed by Scheffe's test. There were no statistical differences in the mean apical dye penetration among the groups 2, 3 and 4 of self-etching primers. And group 1, 2 and 3 had also no statistical difference in apical dye penetration. But, there was statistical difference between group 1 and 4 (p < 0.05). The group 1 showed the least dye penetration. According to the results of this study, Resilon with self-etching primer was not sealed root canal better than gutta precha with $AH26^{(R)}$ at sealing root canals. And there was no significant difference in apical leakage among the three self-etching primers.

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.

Effect of internal gap on retentivity in implant fixed prosthesis with lingual slot (설측 슬롯을 부여한 임플란트 고정성 보철물에서 내면 간격이 유지력에 미치는 영향)

  • Kim, Tae-Kyun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.206-211
    • /
    • 2018
  • Purpose: Recently, a method of forming a slot in the prosthesis lingual has been introduced to solve the occlusal and aesthetic disadvantages of screw-retained prosthesis in the manufacture of implant-fixed prosthesis and to ensure retrievability in cement retained prostheses. The purpose of this study is to investigate the effect of the internal gap on the removal of the prosthesis in the preparation of cement-retained implant prostheses with lingual slots. Materials and methods: Titanium abutment and internal gap of the zirconia prosthesis to be attached to the upper part were set to 30, 35, and $50{\mu}m$, respectively. Three for each type total 15 were produced for each type. The zirconia prosthesis formed a retrievable cement-type slot with a space of 1 mm at the location where the titanium abutment meets the shelf area. Autocatalytic resin cement was used for bonding of abutment and zirconia prosthesis, and the maximum removal stress value was measured in units of Ncm by using the customized equipment of the cemented specimen. The Kruskal-Wallis test was used to compare the three groups by statistical analysis (${\alpha}=.05$), modified by post hoc test the Mann-Whitney U-test and the Bonferroni correction method were used to compare the two methods (${\alpha}=.017$). Results: There was no statistically significant difference in removal stress between the $30{\mu}m$ group and the $35{\mu}m$ group in the internal gap (P = .032), and there was a significant difference between the $30{\mu}m$ group and the $50{\mu}m$ group, between the $35{\mu}m$ group and the $50{\mu}m$ group (P < .017). Conclusion: Thus, the internal gap of computer-aided design affected the retention between the zirconia prosthesis and the titanium abutment.

국제 수학 올림피아드 참가 후보자들을 위한 상황대처훈련에 관한연구

  • 김보경;조성희;이군현
    • Proceedings of the Korean Society for the Gifted Conference
    • /
    • 1994.08a
    • /
    • pp.1.2-37
    • /
    • 1994
  • Currently Korea encourages gifted high schoolers and junior high schoolers to participate in international achievement contests such as International Olympiads. Participants for these contests are selected nationwide among gifted students in areas of mathematics, physics, chemistry, and others. They go through a series of screening tests and programs. One of the screening processes IS Korean Olympiad School, which provides study programs each summer for student-candidates prior to following year's International Olympiads. Approximately 40 students of high schools and junior high schools, in each subject of study, gather at Korean Olympiad Summer School, and they go through intensive study programs during a short period of time. Out of 40 candidates,' less than 10 students are finally selected to participate in International Olympiads. In this study, a psycho-educational program called "Situation Coping Training Program" was developed to enhance ahievement motivation for these student-candidates. This study was to see if this training program actually improved their cognitive, emotive motivation factors, and to see how this training program affected their achievement level. Training was administered for five days. This training program was found effective for participants to increase self-efficacy, internal locus of control, and anxiety copmg. These cognitive and emotive motivation factors, other than intelligence, were found to have positive relationship with achievement level, of which self-efficacy and attribution style of students were found as two best predictors of achievement. This training program was perceived as necessary. by participants, and helpful for recovering self-confidence and self-control as well as coping pressure. Suggestions were made that this kind of training program be administered as a regular curriculum in preparative study programs such as Korean Olympiads, since cognitive, emotive motivation factors are related with achievement, and furthermore, be utilized in all gifted education programs in Korea. in Korea.

  • PDF