• Title/Summary/Keyword: 최대조절력

Search Result 100, Processing Time 0.032 seconds

Comparative Study of the Maximum Accommodative Amplitude in 20's and 40's Myopia (20대와 40대 초반 근시안의 최대조절력 비교)

  • Yun, Jae-Hong;Hwang, Hae-Young;Kim, Soo Woon;Kim, Hyun-Mok;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.273-278
    • /
    • 2012
  • Purpose: Average of the maximum accommodation amplitude of myopia in different generation, early 20's and early 40's were compared according to gender, degree of myopia. Methods: Maximum amplitude of accommodation for each 100 patients of early 20's and 40's were measured with push-up method. Maximum amplitude of accommodation expectations based on Hofstetter formula were classified into three groups of under, normal and excess. Results: The average of amplitude of accommodation was 9.77~11.64 D $(10.77{\pm}2.49D)$ in early 20's and 4.67~6.21 D $(5.34{\pm}1.28D)$ in early 40's. In early 20's, minimum expectations of amplitude of accommodation for under, normal and excess groups were 20%, 75%, and 5%, repectively. In early 40's, excess and under groups were 5% and 18%, repectively, but there was no excess group. Conclusions: According to increasing age, amplitude of accommodation of both age groups showed decreased, and no significant difference was found in degree of myopia with gender. Difference between mean of expected accommodation amplitude and maximum of accommodation amplitude was compared, and it was found that maximum of accommodation amplitude of 20's was smaller than mean of expected accommodation. From the result, it was expected that people in early 20's who have more working times might have festinated accommodative insufficiency than 40's.

The Change of the Accommodative Amplitude in Accordance with the Color of the Spectacle Lens or Object (안경 렌즈 및 물체의 색상에 따른 최대 조절력 변화)

  • Oh, Byung Ha;Lee, Jae Ho;Jung, Sea Hun;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.119-124
    • /
    • 2008
  • Purpose: To determine whether the accommodation of amplitude (AA) was changed by the color of the spectacle lens or object. Methods: AA was measured in forty subjects in their 20s when they viewed different targeton-background color combination with achromatic, gray, brown or green lens. Minus-lens procedures were used for the estimation of AA. Results: When subjects viewed the black-on-white, red-on-white and green-on-white targets, AA under tinted lens tended to be increased compared with AA under achromatic lens. Especially, the green lens significantly increased AA whatever the color of target was. Furthermore, as subjects viewed the green target, AA was the highest irrespective of the color of lens. AA was also changed depending on the color of background, so AA on the red background was lower than on the white background. On the contrary, AA on the green background was higher than on the red or white backgrounds. Of tinted lens, the gray lens increased AA the lowest, but the green lens did the highest. The number of subjects, whose AA were measured more than 9 D, reached to 12.5% with the gray lens, 21.3% with the brown lens, 22.5% with the green lens on the green background, but 5%, 6.5% and 6.5% on the red background, respectively. Conclusions: This results showed that AA varied depending on the color of spectacle lens, objects or background, and the eye fatigue could be decreased with proper color of spectacle lens accordingly.

  • PDF

A Study for Accommodation Power on the Basis of Near Power and Correction Power for distance (근용 도수와 원용 교정도수를 근거로 한 조절력에 관한 연구)

  • Lee, Jeung-Young;Park, Eun-Kyu;Seo, Jeung-Ik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.107-110
    • /
    • 2007
  • Analysis of accommodation amplitude has been conducted for 137 adults, living in rural area, aged from their fifties to eighties. The methods included measurement of correction power for distance via auto-refractometer, measurement of near power based on trial frame and trial lens set, and calculation of effective accommodation amplitude using 1/2 and 2/3 of the maximum accommodation amplitude. The research results for participants aged in their fifties, sixties, seventies, and eighties showed 1.84~2.46D, 1.55~2.06D, 1.43~1.90D, and 1.22~1.62D respectively. It is relatively higher than the existing knowledge regarding accommodation amplitude associated with age.

  • PDF

The Functional Change of Accommodation and Convergence in the Mid-Forties by Using Smartphone (스마트폰 사용에 의한 40대 중년층의 조절 및 폭주기능 변화)

  • Kwon, Ki-il;Kim, Hyun Jin;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.127-135
    • /
    • 2016
  • Purpose: The present study was aimed to investigate the effect of excessive near work by using a smartphone on subjective symptoms and accommodative and convergent function in their 40s. Methods: A total of 40 subjects(male, 10; female, 30; age, $43{\pm}7.2year$) in their 40s who have monocular and binocular visual acuities of 0.8 and 1.0, respectively, were divided into presbyopia group and non-presbyopia group. The subjects were asked to watch a movie on the screen of smartphone for 30 minutes. Their accommodative amplitude and facility, and relative accommodation were measured and compared before and after the use of smartphone. Changes in fusional vergence and near heterophoria by using smartphone were also evaluated. Furthermore, the change of subjective symptoms was surveyed using a questionnaire. Results: The presbyopia in mid-40s reported discomfort in an order of asthenopia, blur and dryness after the use of smartphone. Accommodative function and non-strabismic binocular function were generally decreased. Accommodative functions such as monocular accommodative amplitude, and relative accommodation were significantly decreased after smartphone use, and the change of phoria was observed as a result of decreased convergence and divergence. Negative fusional vergence was also significantly reduced. On the other hand, non-presbyopia in mid-40s reported discomfort in an order of asthenopia, dryness and blur, and only accommodative amplitude among the accommodative functions was significantly reduced. Significant reduction of negative fusional vergence was also observed. Conclusion: From the results, it was confirmed that the subjective discomfort of mid-40s after smarphone use might be related to whether presbyopia or not. It was due to not only the reduction of accommodative function but also the overall deterioration of visual function including heterophoria and fusional vergence. Therefore, it suggests that the accurate determination of the cause based on the overall visual functional tests such as heterophoria, fusional vergence as well as the decrease of accommodation due to the aging may be necessary when the mid-40s feels discomfortable symptoms by near work.

Changes in Accommodative Function after VDT Work (VDT 작업 후의 조절기능 변화)

  • Seo, Eun-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.285-291
    • /
    • 2012
  • Purpose: This study was conducted to research any effect on visual function related to accommodation by VDT work. Methods: The refraction power, accommodative lag, accommodative facility, relative accommodation, amplitude of accommodation and blink rate were measured before and after VDT work for 2 hours on 48 university students (16 males and 32 females), without abnormal accommodative function and systemic and ocular disease, who had never undergone corrective eye surgery. All examinations were performed with distant refraction, and a survey was conducted on the items related to subjective symptoms of VDT syndrome. Results: After 2 hours of VDT work, refractive power increased by 0.23 D, the amount of change in accommodative lag were $0.17{\pm}0.42D$ in the right eye and $0.23{\pm}0.47D$ in the left eye (t=2.26, p=0.03). There were statistically significant differences. Both the accommodative facility and relative accommodation and amplitude of accommodation were decreased after work. However, blink rate were increased. After VDT work, 33.4% of the subjects showed subjective symptoms of asthenopia and 33.3% of them showed shoulder pain. Conclusions: As a result, the accommodative lag increased in response to the two hours of VDT work, and overall accommodative functions were decreased. In addition, as symptoms of providing visual strain, asthenopia showed the most prominent subjective symptoms.

Comparison of Implant Torque Controllers using Detorque Value (풀림토크를 이용한 임플란트 토크조절기의 비교)

  • Huh, Yoon-Hyuk;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.419-432
    • /
    • 2010
  • Various torque generating devices have been developed and employed to apply a proper torque. These devices are usually calibrated by the manufacturer to apply appropriate torque levels for their specific implants and attachments. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; torque limiting device(TLD), torque indicating device(TID) and contra angle torque driver(CA), electronic torque controller(ETC). Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were repeated with each torque controller. All implant torque controllers have shown slight errors and deviations. The contra angle torque driver exhibited the most accurate data. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

The Evaluation of Reliability for Exam Distance of Visual Acuity (시력검사거리에 따른 원거리 시력검사 신뢰성 평가)

  • Chun, Young-Yun;Choi, Hyun-Soo;Park, Seong-Jong;Lee, Seok-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.17-22
    • /
    • 2014
  • Purpose: We aimed to evaluate reliability of eye exam for visual acuity as a function of distance. Methods: There were 39 patients (78 eyes) who had visual acuity 1.0 or more at 5 meters. We measured refractive power of patients at each distances, 5 meters, 4 meters and 3 meters. Automatic chart (LCD-700, Hyeseong Optic. Co., Korea) used for visual acuity, skiascope (Beta 200, Heine, Germany) and auto refractometer (RK-5, Canon, Japan) used as for objective refraction. Accommodation was examined by minus lens addition methods, and Accommodative lag was examined by grid chart for reading distance. Results: Being compared to 3 meter test, Amount of corrected spherical refractive power decreased by $0.10{\pm}0.38$ D, astigmatism decreased by $0.05{\pm}0.10$ D, and axis of astigmatism rotated toward to temporal by $2.64{\pm}18.75$ degrees for right eyes, by $11.43{\pm}48.55$ degrees for left eyes in case of 5 meter test. Changes of corrected refraction and astigmatism were slightly correlated (r=-0.31, r=-0.29). Conclusions: Because corrected refraction power and amount of astigmatism decreased and axis of astigmatism tends to turn the temporal direction according to exam distance, examination distance of visual acuity should improved as to 5 meters.

Changes in Accommodative Function of Young Adults in their Twenties following Smartphone Use (스마트폰 사용에 따른 20대 성인의 조절기능 변화)

  • Park, Mijung;Ahn, Young Joo;Kim, Soo Jung;You, Jiyoung;Park, Kyung Eun;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.253-260
    • /
    • 2014
  • Purpose: The present study was conducted to investigate whether near work with smartphone could induce the change of accommodative function. Methods: Total 63 subjects(26 male and 37 female) in their 20s were firstly examined their visual functions related to accommodation and uncorrected spherical equivalent power as the control. After that, the subjects were asked to read a book for 30 min and sequentially watch a movie on smartphone for the same time after 30 min-break under the indoor light or as it was in the reverse order to avoid time-ordered effect. Their accommodative functions, 1) accommodative amplitude, 2) accommodative facility, 3) relative positive/negative accommodation, and 4) accommodative lag and their uncorrected spherical equivalent power were examined again following each task and compared with the control values. Results: The monocular accommodative amplitude was significantly decreased after smartphone watching compared with it after reading. The monocular and binocular accommodative facilities were tended to reduce after smartphone watching and book reading but were not significantly different. Neither significant change in positive relative accommodation was determined after smartphone watching nor book reading. Negative relative accommodation after smartphone watching was almost unchanged unlike reading a book. The accommodative lag after smartphone work was significantly higher than after book reading. Conclusions: The near work with a smartphone for 30 min induced the change of some accommodative functions, which was significantly greater than when reading under the same working environment.

The Change of Accommodative Function by the Direction of Eye Movements During Computer Game (컴퓨터 게임 시 안구운동의 방향에 따른 조절기능의 변화)

  • Kwon, Ki-Il;Woo, Ji Yeon;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.177-184
    • /
    • 2012
  • Purpose: In this study, the effect of the eye movement direction on visual function related to accommodation was investigated when playing computer games for a certain period of time. Methods: Total 60 subjects in 20s who had the visual acuity of 1.0 or higher without any ocular disease and accommodative dysfunction were asked to play computer games separately in horizontal and vertical directions for 40 and 90 minutes and then measured their accommodative amplitude, accommodative facility, accommodative lag and relative accommodations. Thevisual function when not doing the computer game was regarded as a control value, and further compared and analyzed. Results: The accommodative amplitude, accommodative facility, accommodative lag and relative accommodations showed the tendency of decrease after the computer game for 40 minutes, and more reduced values of the visual functions were shown when the computer game extended up to 90 minutes except positive relative accommodation. Positive relative accommodation had a tendency to increase slightly after the computer game for 90 minutes. Meanwhile, the change of the visual functions was primarily influenced by the eye movement in horizontal direction rather than by the eye movement in vertical direction during computer game when analyzed by the direction of eye movement. Conclusions: Over all accommodative functions tended to decrease with the extended VDT working time by computer game, and the frequent eye movement in horizontal direction during VDT tasks could be the main cause of eyestrain since the eye movement in horizontal direction rather than vertical direction significantly affected the change of accommodative function.

Comparative analysis of accuracy of how to use the implant torque controllers (사용 방법에 따른 임플란트 토크 조절기의 정확성 비교 분석 연구)

  • Cho, Lee-Ra;Park, Chan-Jin;Huh, Yoon-Hyuk;Lee, Ji-Hye;Kim, Dae-Gon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.300-306
    • /
    • 2013
  • Purpose: This study was to evaluate the accuracy of how to use the Mechanical Torque-Limiting Devices. Materials and methods: Three different implant manufacturers (Dentium, Osstem, Shinhung) were prepared for each two implant torque controllers. Divided into two groups depending on the method used for removal torque was measured. Repeated measures of ANOVA test (${\alpha}=.05$) was used as statistics to evaluate the effect of repeated loading number on the removal torque. Independent t-test was used to evaluate the difference in removal torque of two groups. Results: The removal torque significantly decreased as the number of loading repetition increased (P<.05). There was significant difference between two groups. Conclusion: Loosen the handle part of the implant torque controllers spring resilience to recover one group compared to the group that did not, showed a little more closed to the reference value.