• Title/Summary/Keyword: 촬영장치

Search Result 700, Processing Time 0.031 seconds

Treatment of Osteoid Osteoma (유골 골종의 치료)

  • Han, Chung-Soo;Cho, Chang-Hyun;Cho, Young-Lin;Cho, Nam-Su;Lim, Chan-Teak
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • Purpose : The purpose of the current study was to report the results of curettage and en bloc excision as well as to introduce how to excise the nidus percutaneously with Halo-mill. Material and Methods : Twenty patients(14 men and 6 women) were evaluated, who had operative treatments after diagnosed as osteoid osteoma from March 1990 to January 1998. These patients ranged in age from 7 to 42 years(average: 20.8 years). Locations were 9 femurs, 6 tibias, 2 vertebras, 1 ulna, 1 maxilla and 1 skull. Nine femoral lesions included 5 proximal metaphysis, 2 neck and 2 diaphysis, while 5 tibial lesions included 3 diaphysis, 1 proximal metaphysis and 1 distal metaphysis. We used simple radiography, bone scan, CT and MRI for the accurate diagnosis and localization. As for surgical treatments, while excision and curettage had to need open-exposure of lesion, the percutaneous excision of nidus did not need openexposure : guided Halo-mill into K-wire inserted to nidus under image intensifier. Results : Simple radiography showed that 10 cases had typical nidus and others had only cortical sclerosis. Bone scan was performed at 14 cases and all had hot uptake except one case. We used CT in 10 cases and MRI in 4 cases as diagnostic methods, of which 1 case didn't reveal nidus at CT. Surgical treatment consisted of 6 curettages, 11 excisions, 2 percutaneous excisions with halo-mill and 1 total elbow arthroplasty. We used 7mm sized Halo-mill. During the follow-up period, all patient relieved symptoms and there were no recurrences. All had histologically typical findings except one which had hyperostosis without nidus. Conclusion : Complete removal of the nidus is the most important factor in the treatment. We could excise the nidus percutaneously in 2 cases with the minimal injury to surrounding soft tissues. If we could evaluate the precise location, size of nidus and percutaneous acccesibility, the percutaneous excision of nidus with Halo-mill could be an alternative method as a treatment of osteoid osteoma.

  • PDF

Implementation of Radiotherapy Educational Contents Using Virtual Reality (가상현실 기술을 활용한 방사선치료 교육 콘텐츠 제작 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.409-415
    • /
    • 2018
  • The development of smart devices has brought about significant changes in daily life and one of the most significant changes is the virtual reality zone. Virtual reality is a technology that creates the illusion that a 3D high-resolution image has already been created using a display device just like it does in itself. Unrealized subjects are forced to rely on audiovisual materials, resulting in a decline in the concentration of practices and the quality of classes. It used virtual reality to develop effective teaching materials for radiology students. In order to produce a video clip bridge using virtual reality, a radiology clinic was selected to conduct two exposures from July to September 2017. The video was produced taking into account the radiology and work flow chart and filming was carried out in two separate locations : in the computerized tomography unit and in the LINAC room. Prior to filming the scenario and the filming route were checked in advance to facilitate editing of the video. Modeling and mapping was performed in a PC environment using the Window XP operating system. Using two leading virtual reality camera Gopro Hero, CC pixels were produced using a 4K UHD, Adobe, followed by an 8 megapixel resolution of $3,840{\times}2,160/4,096{\times}2,160$. Total regeneration time was performed in about 5 minutes during the production of using virtual reality to prevent vomiting and dizziness. Currently developed virtual reality radiation and educational contents are being used to secure the market and extend the promotion process to be used by various institutions. The researchers will investigate the satisfaction level of radiation and educational contents using virtual reality and carry out supplementary tasks depending on the results.

Noise Properties for Filtered Back Projection in CT Reconstruction (필터보정역투영 CT 영상재구성방법에서 잡음 특성)

  • Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.357-364
    • /
    • 2014
  • The filtered back projection in the image reconstruction algorithms for the clinic computed tomography system has been widely used. Noise of the reconstructed image was examined under the input noise for parallel and fan beam geometries. The reconstruction images of $512{\times}512$ size were carried out under 360 and 720 projection by the Visual C++ for parallel beam and fan beam, respectively, and those agreed with the original Shepp-Logan head phantom very much. Noise was generated because of intrinsic restriction (finite number of projections) for the image reconstruction algorithm, filtered back projection, when no input noise was applied. Because the result noise was rapidly increased under 0.5% input noise ratio, technologies for reducing noise in CT system and image processing is important.

A Study on the Failure Behavior of the Reinforced Earth Wall Structures according to the Deformed Types of the Face (전면부 변형형태에 따른 보강토 벽체 구조물의 파괴거동에 관한 연구)

  • 김준석;이상덕
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.4
    • /
    • pp.167-173
    • /
    • 1999
  • In this paper the failure behavior of the reinforced earth retaining wall structures according to the deformed types of the face was studied by model test using carbon rods. In model test the behavior of the face for the model of the reinforced earth wall was divided into three cases : the displacement of the top part(case 1), the lateral displacement(case 2) and the displacement of the lower part (case 3). The photographic method was applied to examine the failure line of the deformed wall with the naked eye. The failure line shows a parabolic shape for case 1, a large circular arc for case 2 and a logarithmic spiral for case 3 in the experimental results. The design failure line for the coherent gravity structure hypothesis was most similar to the failure line for the case of the lower part displacement.

  • PDF

In Vitro Motion Analysis of Supplementary Valve (생체외 실험을 이용한 보조판막의 운동 연구)

  • 김상현;박영환
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.47-52
    • /
    • 1998
  • To develop the supplementary heart valve which could reduce the complications of prosthetic heart valve, in vitro experiments were performed to analyze the movement of the supplement valves from the view point of the flow dynamics and leaflet dynamics. The autologous pericardium was attached to deficient portion of the porcine valve which was dissected completely and partially. The pericardium was treated by buffered glutaraldehyde solution in the preshaped mould to preserve the shape of the leaflet. The function of the valves were evaluated in the mock circulatory system and three sets of experiment were performed. The instantaneous motion of the leaflet was pictured by the 35mm camera and the pressure drop through the valve and cardiac output were measured. The supplementary valve which was replaced completely performed better thatn the valve replaced partially. In vitro experiments showed that the supplementary valve which was replaced completely performed better than the valve replaced partially. In vitro experiments showed that the supplementary valve could undertake the prosthetic heart valve in clinic.

  • PDF

Assessment of Cancellous Bone of Mandible by Multifunctional Panoramic X-Ray Machine (다기능 파노라마 방사선촬영장치를 이용한 하악해면골질의 평가)

  • Ko Jae-Kyung;Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.16-22
    • /
    • 2000
  • Purpose : To evaluate the bone densities measured on copper-equivalent image of cross sectional view of mandibular edentulous premolar area obtained by multifuctional panoramic x-ray machine, PM 2002 CC with transversal slicing system. Materials and Methods: Panoramic cross sectional views with 8 mm focal layer of aluminum step and blocks, of hydroxyapatite (RA) step, 6 HA blocks and copper step wedge having 0.03 mm thickness of each step, and of 3 bone blocks cutted by 8 mm thickness mesiodistally and a dry mandible with copper step wedge were taken by using transversal slicing system in PM 2002 Cc. All reference-equivalent images were made and analyzed by NIH image program. Results: The average copper-equivalent value of cancellous bone of bone blocks on the panoramic cross sectional view was 0.026 ± 0.020 mm Cu. The calculated average bone density was 0.38g/cm². There was no significant difference (P>0.1) between the bone densities on intraoral digital view and on the panoramic digital cross sectional view. Conclusion: The copper-equivalent image of panoramic digital cross sectional view obtained by PM 2002 CC with very thin copper step wedge was supposed to be useful to measure the bone density of cancellous bone of mandible at the premolar edentulous area.

  • PDF

The Study of the Graph Activity of Gifted Elementary Students Using CBR (CBR을 활용한 초등 영재 학생의 그래프 활동에 관한 연구)

  • Kang, Young Ran;Cho, Cheong Soo
    • School Mathematics
    • /
    • v.17 no.1
    • /
    • pp.65-78
    • /
    • 2015
  • This study has analyzed the effect of graph activity using CBR on the graphic ability through the observation on the 4 math-gifted 5th grade students. The study had designed the graph activity class using CBR based on the theories of graph and progressed it twice for 40 minutes, respectably. The recorded videos of the classes and the interviews of students were collected for analyzing the data, and 2 weeks later, post inspection using the same questionnaire was held for the comparative analysis on the errors that the students had made in the interpretation of the graph. According to the results of this study, the students were able to understand the flow change of the graph, interpret the relationship between variables, and contextualize the dependent variables.

Method for Measuring Weld Temperature Using an Infrared Thermal Imaging Camera (적외선 열화상 카메라를 이용한 용접부의 온도 측정 방법)

  • Ro, Chan-Seung;Kim, Kyeong-Suk;Chang, Ho-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.299-304
    • /
    • 2014
  • In this paper, a method is tested to measure temperatures in high-temperature welds. Protective glass was installed between an infrared thermal imaging camera and a heat source, and temperature compensation was applied to the measuring instruments. When the temperature of halogen lamps was taken in real-time and measured by the thermal camera, the temperature was found to be almost invariant with the distance between the camera and heat source. The temperature range could be predicted, through correlations with the thickness of the protective glass and the measured distance. This study suggests that the temperature measurement of welds obtained by using an infrared thermal imaging camera is valid, through experimental testing of heat sources.

Hybrid Type X-Ray Generator Using EDLC for Fluoroscopy X-Ray System (EDLC를 이용한 X선 투시촬영장치용 하이브리드 X선 제너레이터)

  • Seo, Young-Min;Hong, Soon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.89-98
    • /
    • 2014
  • A diagnostic fluoroscopy X-ray system uses a 32kW or greater X-ray generator for obtaining real-time moving images and high-resolution images. Fluoroscopy X-ray systems have to use a high-capacity AC power source to perform long-time low-power fluoroscopy and short-time high-power spot exposure. In this paper, we propose a hybrid type X-ray generator for fluoroscopy X-ray system which can perform fluoroscopy and spot exposure with a low-capacity AC power source and an energy storage device. The characteristics of energy storage devices are compared and each energy storage device is modelled to equivalent circuit. And the characteristics of available energy are analyzed as a function of output voltage and power. A 32kW class hybrid X-ray generator with EDLC as an energy storage device for fluoroscopy X-ray system was constructed, and its validity was verified by means of simulations and experiments.

Demosaicing Algorithm and Hardware Implementation with Weighted Directional Filtering for Diagonal Edge (방향성 필터를 이용하여 대각선 에지를 고려한 Demosaicing 알고리즘 및 하드웨어 구현)

  • Kwak, Boo-Dong;Jeong, Hyo-Won;Yang, Jeong-Ju;Jang, Won-Woo;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.7
    • /
    • pp.1581-1588
    • /
    • 2010
  • Most digital cameras use a single image sensor with Color Filter Array(CFA) for the advantage of costs and speed. The various color interpolation(demosaicing) algorithms are researched to reconstruct a full representation of the image. In this paper, we proposed a method of demosaicing about using weighted directional filter for vertical, horizontal, and diagonal direction edge. The method considered the efficiency of hardware resources for hardware implementation. The performance of proposed method was confirmed by comparing the conventional method in experiments using 24 Kodak test images. The proposed method was designed by Verilog HDL and was verified by using Virtex4 FPGA boards and CMOS Image Sensor.