• Title/Summary/Keyword: 촬영각도

Search Result 311, Processing Time 0.027 seconds

Distortion of tooth axes on panoramic radiographs taken at various head positions (두부 위치 변화에 따른 파노라마 방사선사진상의 치축각도의 왜곡)

  • Jeon, Hyun-Sang;Choi, Gab-Lim;Lim, Sung-Hoon;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.240-251
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the effect of head position changes on the root parallelism between adjacent teeth on panoramic radiographs. Methods: A model with normal occlusion was constructed in the SolidWorks program, then RP (rapid protyping) model was fabricated. The model was repeatedly imaged and repositioned five times at each of the following nine positions: ideal head position, $5^{\circ}$ up, $10^{\circ}$ up, $5^{\circ}$ down, $10^{\circ}$ down, $5^{\circ}$, right, $10^{\circ}$, up, and $5^{\circ}$ right rotation, $10^{\circ}$ right rotation. Panoramic radiographs were taken by Planmeca ProMax and the angle between the long axes of adjacent teeth was directly measured in the monitor. Results: Axes of adjacent teeth tended to converge toward the occlusal plane when the head tilted up and converged in the opposite direction to the occlusal plane when the head tilted down. Anterior teeth showed the most notable differences. When one side of the head tilted up $5^{\circ}$ and $10^{\circ}$ along the anteroposterior axis (Y axis), tooth axes of the same side tended to converge toward the occlusal plane and tooth axes of the opposite side tended to converge in the opposite direction to the occlusal plane. When the head rotated to one side along the vertical axis (Z axis), the canine and lateral incisor of the same side converged in the opposite direction to the occlusal plane and the canine and lateral incisor of the other side converged toward the occlusal plane. Conclusions: When assessing the root parallelism on panoramic radiographs, the occlusal plane cant (anteroposterior or lateral) or asymmetry of the dental arch should be considered because these can cause distortion of tooth axes on panoramic radiographs.

Development of an Integrated Traffic Object Detection Framework for Traffic Data Collection (교통 데이터 수집을 위한 객체 인식 통합 프레임워크 개발)

  • Yang, Inchul;Jeon, Woo Hoon;Lee, Joyoung;Park, Jihyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.6
    • /
    • pp.191-201
    • /
    • 2019
  • A fast and accurate integrated traffic object detection framework was proposed and developed, harnessing a computer-vision based deep-learning approach performing automatic object detections, a multi object tracking technology, and video pre-processing tools. The proposed method is capable of detecting traffic object such as autos, buses, trucks and vans from video recordings taken under a various kinds of external conditions such as stability of video, weather conditions, video angles, and counting the objects by tracking them on a real-time basis. By creating plausible experimental scenarios dealing with various conditions that likely affect video quality, it is discovered that the proposed method achieves outstanding performances except for the cases of rain and snow, thereby resulting in 98% ~ 100% of accuracy.

Gimbal System Control for Drone for 3D Image (입체영상 촬영을 위한 드론용 짐벌시스템 제어)

  • Kim, Min;Byun, Gi-Sig;Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.11
    • /
    • pp.2107-2112
    • /
    • 2016
  • This paper is designed to develop a Gimbal control stabilizer for drones Gimbal system control for drone for 3D image to make sure clean image in the shaking and wavering environments of drone system. The stabilizer is made of tools which support camera modules and IMU(Inertial Measurement Unit) sensor modules follow exact angles, which can brock vibrations outside of the camera modules. It is difficult for the camera modules to get clean image, because of irregular movements and various vibrations produced by flying drones. Moreover, a general PID controller used for the movements of rolling, pitching and yawing in order to control the various vibrations of various frequencies needs often to readjust PID control parameters. Therefore, this paper aims to conduct the Intelligent-PID controller as well as design the Gimbal control stabilizer to get clean images and to improve irregular movements and various vibrations problems referenced above.

Influence of the Lumbar Spine Adjustment using the Lumbar Roll Support on Head and Neck Posture in Older Adults (요추 지지대에 의한 노인의 요추만곡 조절이 머리와 목 자세에 미치는 영향)

  • Ko, Seung-Hyun;Kim, Yu-Shin;Yoon, Bum-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.800-806
    • /
    • 2011
  • The objective of this study was to identify the effect of lumbar lordotic curve adjustment on head and neck posture in older adults. Methods Twenty healthy older participants (mean age 71.32) were photographed while watching monitor in sitting with or without lumbar roll support(length 28cm, diameter 10cm). The upper cervical angle and lower cervical angle were measured using the NIH ImageJ 1.32. Comparisons between upper and lower cervical angle with or without lumbar roll support were made using paired-t test analysis. Results Subjects demonstrated a significant difference in the mean upper and lower cervical angle. Mean difference of the upper cervical angle was about $2.83^{\circ}$ with and without lumbar roll support(p<0.005). Mean difference of the lower cervical angle was about $4.44^{\circ}$ with and without lumbar roll support(p<0.0001). Conclusions This study showed that healthy older adults demonstrated more ability to maintain an upright posture of cervical spine during lumbar lordotic curve maintenance with lumbar roll support than without lumbar roll support. When the clinicians consider improvement of the head and neck posture in older adults, they must incorporate adjustment in the lumbar region.

Study of Computed Tomography Reconstruction Angle of Bony Stenosis of the Cervical Foramen (경추 신경공 골성 협착에서 CT 재구성 각도 연구)

  • Yon-Min, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.919-925
    • /
    • 2022
  • This study is an image reconstruction method after cervical CT scan. According to the oblique coronal reconstruction angle, i would like to suggest the reconstruction angle that can best express neural foraminal bony stricture. The angle created by drawing a line passing through the center of the spinal cord in the midsagittal plane of the cervical spine and the uncovertebral joint was measured. A line passing through the center of the spinal cord was drawn from the neural foramen, and the angle formed with the midsagittal plane was measured and compared. At the C4-5 level, the average was 9.2°, at the C5-6 level, the average was 9.9°, and at the C6-7 level, the average was 8.4°, the neural foraminal angle was measured to be larger than the uncovertebral joint angle. There was a statistically significant difference in mean (p<0.01). Also, it was found that the angle increased toward the lower cervical vertebrae. The angle between the neural foramen of the lower cervical vertebrae (C5-6, C6-7) and the center of the spinal cord is between 55 and 60°. Here, if the oblique coronal image is reconstructed to be 90°, the degree of neural foramen stenosis can be observed well. Because it is an image reconstruction using a conventional CT scan image, it does not receive additional radiation exposure. It is of great significance in diagnosing cervical neural foramen bony stenosis.

Study of Suitable Angle of Tibia-Foot and X-ray Tube for Navicular in Foot X-ray Examination (족부 X선 검사에서 주상골 관찰에 용이한 Tibia-Foot angle과 X-ray tube 각도에 대한 연구)

  • Moon, Joo-Wan;Han, Jae-Bok;Choi, Nam-Gil
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • The purpose of this study was to determine suitable angle of Tibia-foot and the X-ray tube for scaphoid in foot X-ray examination. A total of twenty patients(mean age $32.12{\pm}years)$ are participated in this study. In the positions of Foot AP, internal and external oblique, tibia-foot angle was defined as $90^{\circ}$ and $135^{\circ}$, and x-ray tube angle was defined as $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$ and $20^{\circ}$ respectively. The image quality was evaluated with blind test yielding scores ranging from 0 to 5 by the evaluation team consisted of 2 radiogical technologists, 2 radiologists, and 2 orthopedic surgeons. In case of Foot AP position, the degree of overlap between cuneiform and navicular was 3% and the blind test result was 4.89 at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle. When the tibia-foot angle is $135^{\circ}$, the degree of overlap was 5%, also the blind test result was 4.30 at $15^{\circ}$ X-ray tube angle. The degree of overlap and blind test result were 30% and 3.75 respectively at $0^{\circ}$ X-ray tube angle. In case of internal oblique position, at tibia-foot angle of $90^{\circ}$ and $0^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test result was 4.70. The 5% overlapping and highest score as 4.55 were obtained on tibia-foot angle of $135^{\circ}$ and $0^{\circ}$ X-ray tube angle. In case of external oblique position, at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test score was 4.85. The 5% overlapping and highest score as 4.75 were obtained on tibia-foot angle of $135^{\circ}$ and $15^{\circ}$ X-ray tube angle. In conclusion, we confirmed suitable angle of tibia-foot and X-ray tube for scaph46oid in foot X-ray examination in this study. These findings will be helpful for us to reading for navicular fracture.

A Study on the Shooting Traning of Basketball Sports Club using Video File (영상 자료를 활용한 학생 농구부 슈팅 훈련 지도방안)

  • Kim, Semin;Lee, Gyujeong;Lee, Jeongwon;Jeon, Byungil;Hong, Ki-Cheon;You, Kangsoo;Lee, Choong Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.382-384
    • /
    • 2019
  • In this study, we analyzed the angle of shooting based on the footage of shooting training of basketball student athletes taken by the basketball team leaders. In the shooting video, the shot height of the player and the trajectory of the ball were drawn through a solid line, and the player was shown to guide the player to adjust the angle of projection to a situation where the success rate was higher. Through this study, the video shows that efficient guidance can be made available to basketball players.

  • PDF

Relationship of Trochlear Medial Facet Osteophyte to Elbow Flexion in Elbow Joint without Trauma History (외상력이 없는 주관절에서 활차 내측 골극과 주관절 굴곡 제한과의 관계)

  • Kim, Byung Sung;Park, SungYong;Park, Kang Hee;Song, Hyun Seok;Kim, Hyung Tae;Yoon, Hong Kee;Nho, Jae Hwi
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.100-106
    • /
    • 2013
  • Purpose: The purpose of this study is to evaluate the relationship between trochlear medial facet osteophyte (TMFO) and elbow flexion in the elbow joints without trauma history. Materials and Methods: Twenty five patients, who underwent computed tomography without elbow trauma history, were reviewed. Patients were checked for osteophyte or loose bodies in the coronoid and olecranon sides. The height and length of TMFO were measured. Results: The average elbow flexion contracture was $18.6^{\circ}$, and further flexion was $112.1^{\circ}$. The TMFO height and length was 2.2 mm and 4.7 mm, respectively. The average elbow further flexion was $105.1^{\circ}$ in the coronoid block group (n=14) and $119.1^{\circ}$ (p=0.011) in the coronoid free group (n=11). The relationship between further elbow flexion and TMFO was significant with a partial correlation coefficient of 0.687(p<0.000) in the TMFO length. Conclusion: Elbow joints with longer TMFO length decrease further flexion.

Morphological Analysis of the Mental Foramen and Anterior Loop of the Mandibular Canal using Computed Tomography (전산화단층촬영 방사선영상을 이용한 이공과 하악관 전방고리의 형태학적 분석)

  • Kim, Yong-Gun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.317-326
    • /
    • 2011
  • The mental foramen and anterior loop of the mandibular canal are important landmarks for mandibular surgical procedures. The purpose of this study was to analyze the shape and position of the mental foramen and anterior loop of the mandibular canal on the computed tomography (CT) images, and apply the results clinically. CT images of 96 patients (33 male, 36 female, age range 17~43 years, mean $24.6{\pm}4.99$ years) were enrolled. The horizontal and vertical position of the mental foramen, as well as the distance from the root apices were measured. The distance of the anterior loop of the mandibular canal to the root apices, and the buccal angle were measured. The mental foramen was found mostly below the second premolar observed in 81 cases (46.0%), between the first and second premolars in 67 cases (38.0%), and between the second premolar and first molar in 19 cases (10.2%). The mean distance between the mental foramen and the lower border of the mandible was $12.20{\pm}1.77$ mm, the mean distance between the mental foramen and root apex was $5.16{\pm}0.98$ mm. The mean distance of the anterior loop of the mandibular canal was $5.80{\pm}2.00$ mm. The buccal angle measured at $47.7{\pm}9.07^{\circ}$. The distance between the root apex and mental foramen measured as $5.16{\pm}0.98$ mm on panoramic radiography, and $6.2{\pm}3.07$ mm on CT. The mean distance between the mental foramen and mandibular canal was $5.39{\pm}1.62$ mm. When performing surgical procedures such as installing dental implants, it is important to minimize surgical trauma, especially the risk of damage to the mental nerve. To optimize the surgical outcome, a careful assessment of the shape and position of the mental foramen and the anterior loop of the mandibular canal must be made. CT images are useful for finding such anatomic structures.

The Accuracy of Stereo Digital Camera Photogrammetry (스테레오 디지털 카메라를 이용한 사진측량의 정확도)

  • Kim, Gi-Hong;Youn, Jun-Hee;Park, Ha-Jin
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.6
    • /
    • pp.663-668
    • /
    • 2010
  • In this study a stereo digital camera system was developed. Using this system, we can collect informations such as coordinates, lengths of all objects shown in the photo image just by taking digital photograph in field. This system has the advantage of obtaining stereo images with settled exterior orientation parameters, while the accuracy slightly worsen because in a close range photogrammetry with stereo digital camera system, the base line distance is restricted within about 1m. We took images with various exposure distances and angles to objects for experimental error assessment, and analyzed the affection of image coordinates errors.