• Title/Summary/Keyword: 초음파

Search Result 7,634, Processing Time 0.047 seconds

Characteristics of High Frequency Ultrasonic Transducer Employing Polyvinylidene Fluoride and Detectability of Flaw in Cr-Ni Steel (PVDF 수침용 고주파수 초음파 탐촉자의 검출장과 Cr-Ni 강에서의 결함 검출능 측정)

  • Kim, Byoung-Geuk;Lee, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.1
    • /
    • pp.23-30
    • /
    • 1997
  • Recently high frequency ultrasonic transducers to employ polyvinylidene fluoride(PVDF) or polyvinylidene fluoride trifluoroethylene P(VDF-TrFE) have been used to detect small flaws in immersion testing. The detection field depending on the water path between the transducer and a specimen and the path in a tested specimen was measured using a PVDF transducer with nominal frequency 80MHz. Also, C-scan and B-scan were performed for the specimens made of Cr-Ni steel with the artificial flaws, the flat-bottom holes with diameter ranging from $50{\mu}m$ to $560{\mu}m$ at 12mm depth. As the result, the flaws with diameter larger than $280{\mu}m$ were detected, but the flaws with the ratio of diameter to wavelength smaller than about 0.48 were not detected. That the smaller flaws could not be detected was attributed to the attenuation of high frequency components in the steel specimens.

  • PDF

Characterization of Elastic Modulus of Kelvin Foam Using Elastic Structural Model and Ultrasound (초음파와 탄성 구조 모델을 이용한 캘빈 폼 재료의 탄성계수 평가)

  • Kim, Woochan Ethan;Kim, Nohyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.474-482
    • /
    • 2016
  • A Kelvin foam plate - widely used in the energy and transport industries as a lightweight structural material - was examined to estimate its Young's modulus using ultrasound. An isotropic tetrakaidecahedron foam structure was designed in SolidWorks and printed using 3D printer with an ABS plastic material. The 3D printed foam structure was used to build a foam plate with a 14 mm thickness ($50mm{\times}100mm$ in size) for the ultrasonic test. The Kelvin foam plate, a significantly porous medium, was completely filled with paraffin wax to enable the ultrasound to penetrate through the porous medium. The acoustic wave velocity of the wax-filled Kelvin foam was measured using the time of flight (TOF) method. Furthermore, the elastic modulus of the Kelvin foam was estimated based on an elastic structural model developed in this study. The Young's modulus of the produced Kelvin foam was observed to be approximately 3.4% of the bulk value of the constituent material (ABS plastic). This finding is consistent with experimental and theoretical results reported by previous studies.

The Impacts of Piezoelectric Elements' Defects On Color & Power Doppler Images (초음파 프로브에서 소자결함이 컬러 및 파워 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2015
  • An ultrasound probe has a big impact on Doppler images even though it has very high risk of frequent function-breakdowns occurring in medical ultrasound scanners. This study experimentally analyses the impacts of an ultrasonic probe's defected elements on power & color Doppler images. The results show that, the bigger the size of defected probe elements is, and the closer a group of action elements is to the center, the more the brightness of images and the velocity of Doppler diminish. When elements' defects increase in color & power Doppler images, false images are formed to be mistaken for blood-vessel plaque in neighboring regions. Accordingly, whenever element defects are suspected, we need check-up process in B-mode. From this respective, it is advisable to have primary interest in a probe and carry out continuous probe QA for ultrasonography.

Reconstructing Flaw Image Using Dataset of Full Matrix Capture Technique (Full Matrix Capture 데이터를 이용한 균열 영상화)

  • Lee, Tae-Hun;Kim, Yong-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.13-20
    • /
    • 2017
  • A conventional phased array ultrasonic system offers the ability to steer an ultrasonic beam by applying independent time delays of individual elements in the array and produce an ultrasonic image. In contrast, full matrix capture (FMC) is a data acquisition process that collects a complete matrix of A-scans from every possible independent transmit-receive combination in a phased array transducer and makes it possible to reconstruct various images that cannot be produced by conventional phased array with the post processing as well as images equivalent to a conventional phased array image. In this paper, a basic algorithm based on the LLL mode total focusing method (TFM) that can image crack type flaws is described. And this technique was applied to reconstruct flaw images from the FMC dataset obtained from the experiments and ultrasonic simulation.

Discharge Measurement by Ultrasonic Discharge Measurement System (초음파 유량측정 시스템에 의한 유량측정)

  • Kim, Chi Young;Yoon, Gwang Suk;Kim, Dong Gu;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1198-1202
    • /
    • 2004
  • 초음파를 이용한 측정은 하천의 반대편에 흐름방향에 경사지게 초음파를 발사하여 다시 반사되어 오는 시간차를 기록함으로써 주어진 길이에서 유속을 연속적으로 측정하는 것이다. 하류로 내려가는 음파는 음향 측선(acoustic path)과 평행한 유속 성분 때문에 상류로 올라가는 음파보다 빠른 속도를 가진다. 탄천 및 괴산댐에 초음파 유량 측정시스템을 시험 설치하고 운영 결과를 검토하였다. 시험적용결과 연속적인 유량자료 획득이 가능하였으며, 기존 유속면적법 대비 $4.21\%$의 상대오차를 지니고 있어 기존 방법과 비교적 일치하는 측정결과를 나타냈다. 또한 지표유속(Index Velocity)를 활용한 단일회선 유량산정법을 검토한 결과, 다회선에 의해 운영한 결과와 평균 $2.9\%$의 상대오차를 지니고 있었다. 이 방법은 조석구간 및 배수영향을 받는 구간에서 작은 비용으로 연속유량자료를 획득할 수 있는 방법으로 판단된다. 시험적용 결과 개선해야 할 사항으로는 안정적인 자료 획득을 위한 초음파 변환기의 개선, 자료의 필터링 기술의 정밀화, 그리고 유량산정 방법에서 정확도 향상 기술 개발 등이 도출되었다. 초음파 유량 측정시스템은 자료의 연속성을 확보할 수 있는 점에서 매우 중요한 의미를 지니고 있다. 지금까지의 연속 유량 산출법은 연속적인 수위를 측정하고 각 수위에 따른 유량 측정 후 수위-유량관계를 통하여 연속적인 유량을 산출하였다. 그러나 초음파 유량 측정 시스템은 직접 유속과 수위를 측정하여 연속유량이 산출되기 때문에 연속유량 산출에 비교적 간편하다고 할 수 있다. 또한 정확도 면에서 기존 유량 측정법인 유속-면적법의 불확실도 $5\%\~10\%$에 비교하여 $5\%$ 내외의 정확도 수준을 지니고 있어 정확도 향상을 기대할 수 있다. 경제적인 측면에서도 매년 측정사업에 소요되는 비용과 비교하였을 때 장기적으로는 경제적인 방법이 될 수 있다.

  • PDF

Construction of Ultrasonic Power Measurement System and Its Performance Evaluation (초음파 파워 측정 시스템 구성 및 성능평가)

  • Jho Moon Jae;Kim Yong Tae;Yun Yong Hyeon;Jung Suug Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.8
    • /
    • pp.431-440
    • /
    • 2005
  • The precise measurement of ultrasonic power is important to the qualify assurance and the safety of medical ultrasonic equipments In the Present work, a brier theory was introduced to determine the ultrasonic Power from the time valving balance-indication due to the radiation force acting on an absorbing target and/or other causes such as buoyancy during the repetition of on/off behavior of ultrasonic irradiation. The developed automated system measuring the ultrasonic power was described in detail with the precise mechanical alignment tool , the electric signal generation network, the control and measurement network and the appropriate procedure. The ultrasonic power measured by the developed system was compared to the reference data calibrated by the other national metrology institute at 1 MHz, 5 MHz, 10 MHz, and 15 MHz over the range 10 mW to 10 W. Their relative differences are within $5\%$.

Ultrasound Related Anatomy and Biomechanics of Shoulder Joint (초음파 영상과 관련된 견관절 해부학 및 생역학)

  • Kim, Yang-Soo;Lee, Jae-Young
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.112-116
    • /
    • 2008
  • Ultrasonography of shoulder joint recently enlarges its utility since the knowledge of the shoulder disease is increased by numerous researches. Ultrasonography is not only noninvasive, safe, and relatively cheap, but also an unique modality that can monitor tendon movement during shoulder motion. Sonographic examination generally starts from the front side of the shoulder joint and finishes at back side in sitting position. Many structures in shoulder joint such as muscles, ligaments, glenoid labrum, bone, and especially rotator cuff tendon can be examined by ultrasonography. The rotator cuff is a motion unit consisted with subscapularis, supraspinatus, infraspinatus, and teres minor muscles. It functions as fulcrum and compresses the humeral head onto the glenoid, and steers for shoulder joint.

  • PDF

Implementation of low-noise, wideband ultrasound receiver for high-frequency ultrasound imaging (고주파수 초음파 영상을 위한 저잡음·광대역 수신 시스템 구현)

  • Moon, Ju-Young;Lee, Junsu;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.238-246
    • /
    • 2017
  • High frequency ultrasound imaging typically suffers from low sensitivity due to the small aperture of high frequency transducers and shallow imaging depth due to the frequency-dependent attenuation of ultrasound. These limitations should be overcome to obtain high-frequency, high- resolution ultrasound images. One practical solution to the problems is a high-performance signal receiver capable of detecting a very small signal and amplifying the signal with minimal electronic noise addition. This paper reports a recently developed low-noise, wideband ultrasound receiver for high-frequency, high-resolution ultrasound imaging. The developed receiver has an amplification gain of up to 73 dB and a variable amplification gain range of 48 dB over an operating frequency of 80 MHz. Also, it has an amplification gain flatness of ${\pm}1dB$. Due to these high performances, the developed receiver has a signal-to-noise ratio of at least 8.4 dB and a contrast-to-noise ratio of at least 3.7 dB higher than commercial receivers.

Effect of Ultrasound on the Decomposition of Sodium Dodecylbenzene Sulfonate in Aqueous Solution (Sodium Dodecylbenzene Sulfonate 수용액의 분해반응에서 초음파 효과)

  • Yim, Bong-Been
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.561-567
    • /
    • 2004
  • The influence of ultrasound frequency, dissolved gases, and initial concentration on the decomposition of sodium dodecylbenzene sulfonate(DBS) aqueous solution was investigated using ultrasound generator with 200 W ultrasound power. The decomposition rates at three frequencies(50, 200, and 600 kHz) examined under argon atmosphere were highest at 200 kHz. The highest observed decomposition rate at 200 kHz occurred in the presence of oxygen followed by air and argon, helium, and nitrogen. The effect of initial concentration of DBS on the ultrasonic decomposition was decreased with increasing initial concentration and would depend upon the formation of micelle in aqueous solution. It appears that the ultrasound frequency, dissolved gases, and initial concentration play an important role on the sonolysis of DBS. Sonolysis of DBS mainly take place at the interfacial region of cavitation bubbles by both OH radical attack and pyrolysis to alkyl chain, aromatic ring, and headgroup.

Reflection and Transmission Characteristics of Oblique-Incidence Ultrasonic Waves at Solid-Solid Contact Interfaces (고체-고체 접촉계면에서 경사입사 초음파의 반사·투과 특성 분석)

  • Nam, Tae-Hyung;Kim, Chung-Seok;Lee, Tae-Hun;Jhang, Kyung-Young;Kim, Noh-Yu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.9
    • /
    • pp.1113-1118
    • /
    • 2011
  • In order to evaluate the characteristics of solid-solid contact interfaces, reflection or transmission techniques involving normal-incidence longitudinal waves are generally used. However, these normal-incidence techniques are of limited use in field applications such as in the inspection of welded parts. The oblique-incidence ultrasonic technique may be an alternative for overcoming these problems. However, in this technique, the mode conversion at the contact interfaces should be taken into account along with the normal and tangential interface stiffness. In this study, we have suggested a theoretical model for obliqueincidence ultrasonic waves at the contact interfaces and analyzed their reflection and transmission characteristics. Experimental results showed that the measured reflection coefficient and second harmonic wave agreed well with the suggested theoretical model. Consequently, the oblique-incidence technique can be a promising method for evaluating the characteristics of the contact interfaces.