• Title/Summary/Keyword: 초고강도 콘크리트

Search Result 440, Processing Time 0.043 seconds

The Effects of Mixture Rate and Aspect Ratio of Steel Fiber on Mechanical Properties of Ultra High Performance Concrete (강섬유 혼입율 및 형상비가 초고강도 콘크리트의 역학적 성질에 미치는 영향)

  • Choi, Jung-Gu;Lee, Gun-Cheol;Koh, Kyung-Taek
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.1
    • /
    • pp.14-20
    • /
    • 2017
  • Ultra high performance concrete is inevitably used in case of skyscraper and super long span bridge. In general, the flexural and the tensile strengths of concrete are lower than the compressive strength, so brittle cracks occur and energy absorption ability is lowered. In order to solve this problem, this study is intended to examine the effect of the steel fiber volume fraction and aspect ratio on the mechanical properties of ultra high performance concrete. In series I, 20-mm straight steel fiber was added with a volume fraction of 0, 1.0, 1.3, 1.5 and 2.0%. In series II, 16-mm steel fiber was added with a volume fraction of 0, 1, and 1.5%, and then mechanical properties were examined according to aspect ratio. In the results of experiment, a difference in compressive strength was insignificant. However, regarding the flexural strength and tensile strength, as the volume fraction and aspect ratio increased, flexural performance and tensile performance improved.

Design Equations of Compression Splice Strength and Length in Concrete of 100 MPa and Less Compressive Strength (100 MPa 이하 콘크리트의 철근 압축 이음 강도와 이음 길이 설계)

  • Chun, Sung-Chul;Lee, Sung-Ho;Oh, Bo-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.2
    • /
    • pp.211-217
    • /
    • 2011
  • Although a compression splice length does not need to be longer than a tension splice length due to end bearing effect, current design codes impose a longer compression lap splice than a tension lap splice in high strength concrete. Hence, new criteria for the compression lap splice including concrete strength effect need to be found for economical design of ultra-high strength concrete. An experimental study has been conducted using column specimens with concrete strength of 80 and 100 MPa with transverse reinforcement. The test results showed that splice strengths improved when the amount of transverse reinforcement increased. However, end bearing strength did not increase when larger amount of transverse reinforcement is provided within the spliced zone. Therefore, the splice strength enhancement was attributed to the improvement of bond. From regression analysis of 94 test results including specimens made with concrete strength of 40 and 60 MPa, a new design equation is proposed for compression lap splice in the concrete compressive strength ranging from 40 to 100 MPa with transverse reinforcement. By using the proposed equation, the incorrect design equations for lap splice lengths in tension and compression can be corrected. In addition, the equation has a reliability equivalent to those of the specified strengths of materials.

A study on the fire resistance properties of high strength concrete by incorporation of combined fiber (복합섬유 혼입에 의한 고강도콘크리트의 내화특성에 관한 연구)

  • Kim, Jeong-Jin;Kim, Kwang-Ki;Park, Soon-Jeon;Lee, Joo-Ho;Shin, Jae-Kyung;Jeong, Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.469-470
    • /
    • 2009
  • Recently, so that HSC can secure the fire resistance properties at the time of a fire in super tall building suggested method of combined fiber. Thus, there is the purpose to develop the high fireproof concrete which applied method of combined fiber which can satisfy flowability and the fire resistance properties of HSC for construction of the super tall building.

  • PDF

Experimental Study to Evaluate the Durability of 100 MPa Class Ultra-high Strength Centrifugal Molding Concrete (100MPa급 초고강도 원심성형 콘크리트의 내구성 평가를 위한 실험연구)

  • Jeong-Hoi Kim;Sung-Jin Kim;Doo-Sung Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.12-23
    • /
    • 2024
  • In this study, a structural concrete square beam was developed using the centrifugal molding technique. In order to secure the bending stiffness of the cross section, the hollow rate of the cross section was set to 10% or less. Instead of using the current poor mixture of concrete and a concrete mixing ratio with a high slump (150-200) and a design strength of 100 MPa or more was developed and applied. In order to investigate the durability of centrifugally formed PSC square beams to be used as the superstructure of the avalanch tunnel or ramen bridge, the durability performance of ultra-high-strength centrifugally formed concrete with a compressive strength of 100 MPa was evaluated in terms of deterioration and chemical resistance properties.Concrete durability tests, including chloride penetration resistance, accelerated carbonation, sulfate erosion resistance, freeze-thaw resistance, and scaling resistance, were performed on centrifugally formed square beam test specimens produced in 2022 and 2023. Considering the information verified in this study, the durability of centrifugally molded concrete, which has increased watertightness in the later manufacturing stage, was found to be superior to that of general concrete.

Characteristics of Strength Development of Ultra-High Performance Concrete according to Curing Condition (초고성능 콘크리트의 양생 조건에 따른 강도 발현 특성)

  • Park, Jong-Sup;Kim, Young-Jin;Cho, Jeong-Rae;Jeon, Se-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.295-304
    • /
    • 2013
  • Ultra-High Performance Concrete (UHPC) has recently been one of the most active research fields in Korea as well as in foreign countries, because it can contribute to a longer life and economic efficiency of structures. Although precast-type UHPC fabricated in a factory is preferable in terms of quality control and reduction of construction period, there exist, even in the precast structure, some parts that need to be cast in-place such as the joints between precast segments. In the cast-in-place UHPC, however, it is probable that an optimum curing condition can hardly be realized in contrast to the factory production. In this study, therefore, the trend of compressive strength development of UHPC was experimentally investigated by assuming various inferior curing conditions that may be anticipated at a construction site. Concrete specimens were fabricated and cured under different conditions with the variables such as curing temperature, delay time before the initiation of curing, duration of curing time and moisture condition. The strengths were compared with those of the specimens cured by standard high temperature steam. Through the analysis of the test results, some minimum requirements for curing have been proposed that are required when the UHPC is cast in-place. It is expected, through this study, that practical use of UHPC in construction sites can be increased.

Research on the Mock-up for CFT Using 100MPa High Strength Concrete and 800MPa High Strength Steel (800MPa 고강도 강재 및 100MPa 초고강도 콘크리트를 활용한 CFT 합성 구조 시스템 개발을 위한 현장 성능평가에 관한 연구)

  • Kim, Woo-Jae;Lee, Youg-Do;Park, Hee-Gon;Lee, Jae-Sam;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.35-37
    • /
    • 2011
  • This study was a comparison result between the laboratory and mock up test to apply the ultra high strength concrete to CFT(Concrete Filled Tube) structure. The investigated result of tendency and quality similarity of each specimen, was set up a management range according to checking the validity and suitability analysis. Also, It wil be utilized to data as construction guidelines of CFT.

  • PDF

Thermal Strain Properties of Ultra High Strength Concrete according to the Compressive Strength (압축강도에 따른 초고강도 콘크리트의 열변형 특성)

  • Yoon, Min-Ho;Kim, Gyu-Yong;Choe, Gyeong-Cheol;Hwang, Eui-Chul;Lee, Bo-Kyeong;Seo, Won-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.24-25
    • /
    • 2016
  • In this study, the thermal strain of high strength concrete with the compressive strength of 80, 130, 180MPa were measured under 25% of compressive strength loading condition. As results, it is considered that decline of the elastic modulus and shrinkage strain of high strength concrete become grater at the elevated temperatures.

  • PDF

An Experimental Study on appropriate water-binder ratio for development of ultra high strength concrete (초고강도 콘크리트 개발을 위한 적정 물-결합재비 선정에 관한 실험적 연구)

  • Jang, Jong-Min;Jang, Hyun-O;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.79-80
    • /
    • 2016
  • In this study, we measured the relative density and the compressive strength in order to select the appropriate W/ B for the ultra-high strength concrete development. If W/B is lowered than the W/B of highest relative density, it was confirmed that the strength is lowered. However, if water is increased than the W/B of highest relative density, the relative density is decreased compressive strength was similar. The selection of the W/B of the lower than the highest relative density is not appropriate. Appropriate W/B is selected to be more than the maximum relative density of W/B.

  • PDF

Evaluation on Mechanical Properties of PP Fiber Ultra High Strength Concrete at Elevated Temperatures (PP섬유 혼입에 따른 초고강도 콘크리트의 고온역학적특성 평가)

  • Bang, Deog-Yun;Kim, Gyu-Yong;Choe, Gyeong-Cheol;Yoon, Min-Ho;Lee, Bo-Kyeong;Hwang, Eui-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.53-54
    • /
    • 2016
  • In this study, the effect of high temperature on the compressive strength and elastic modulus of ultra high strength concrete with PP fiber were experimentally investigated. As the result, the compressive strength and elastic modulus of ultra high strength concrete were irrespectively evaluated mixed ratio of PP fiber at high temperature.

  • PDF