Browse > Article
http://dx.doi.org/10.4334/JKCI.2011.23.2.211

Design Equations of Compression Splice Strength and Length in Concrete of 100 MPa and Less Compressive Strength  

Chun, Sung-Chul (Dept. of Architectural Engineering, Mokpo National University)
Lee, Sung-Ho (Daewoo Institute of Construction Technology, Daewoo E&C Co., Ltd.)
Oh, Bo-Hwan (Daewoo Institute of Construction Technology, Daewoo E&C Co., Ltd.)
Publication Information
Journal of the Korea Concrete Institute / v.23, no.2, 2011 , pp. 211-217 More about this Journal
Abstract
Although a compression splice length does not need to be longer than a tension splice length due to end bearing effect, current design codes impose a longer compression lap splice than a tension lap splice in high strength concrete. Hence, new criteria for the compression lap splice including concrete strength effect need to be found for economical design of ultra-high strength concrete. An experimental study has been conducted using column specimens with concrete strength of 80 and 100 MPa with transverse reinforcement. The test results showed that splice strengths improved when the amount of transverse reinforcement increased. However, end bearing strength did not increase when larger amount of transverse reinforcement is provided within the spliced zone. Therefore, the splice strength enhancement was attributed to the improvement of bond. From regression analysis of 94 test results including specimens made with concrete strength of 40 and 60 MPa, a new design equation is proposed for compression lap splice in the concrete compressive strength ranging from 40 to 100 MPa with transverse reinforcement. By using the proposed equation, the incorrect design equations for lap splice lengths in tension and compression can be corrected. In addition, the equation has a reliability equivalent to those of the specified strengths of materials.
Keywords
compression lap splice; bond; end bearing; splice length; transverse reinforcement;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 한국콘크리트학회, "콘크리트 구조설계기준 해설," 기문당, 2008, 524 pp.
2 ACI Committee 318, “Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary,” ACI, Farmington Hills, Mich., USA, 2008, 465 pp.
3 Chun, S. C., Lee, S. H., and Oh, B., “Compression Lap Splice in Unconfined Concrete of 40 and 60 MPa (5800 and 8700 psi) Compressive Strengths,” ACI Structural Journal, Vol. 107, No. 2, 2010, pp. 170-178.
4 천성철, 이성호, 오보환, “횡보강근이 있는 40, 60 MPa 콘크리트에서 철근 압축 이음의 거동과 강도,” 콘크리트학회 논문집, 21권, 4호, 2009, pp. 389-400.
5 천성철, 이성호, 오보환, “횡보강근이 없는 100 MPa 이하 콘크리트의 철근 압축 이음 강도와 이음 길이,” 콘크리트학회 논문집, 22권, 5호, 2010, pp. 659-666.   과학기술학회마을   DOI   ScienceOn
6 Comite Euro-International du Beton, CEB-FIP Model Code, 1990, London, Thomas Telford, 437 pp.
7 Cairns, J., “Strength of Compression Splices: A Reevaluation of Test Data,” ACI Journal, Proceedings, Vol. 82, No. 4, 1985, pp. 510-516.
8 Orangun, C. O., Jirsa, J. O., and Breen, J. E., “A Reevaluation of Test Data on Developoment Length and Splices,” ACI Journal, Proceedings, Vol. 74, No. 3, 1977, pp. 114-122.
9 KS D 3504 : 2009, 철근콘크리트용 봉강, 산업자원부 기술표준원, 2009, 30 pp.
10 ACI Committee 408, Bond and Development of Straight Reinforcing Bars in Tension (ACI 408R-03), ACI, Farmington Hills, Mich., USA, 2003, 49 pp.
11 ISO 6935-2 Steel for the Reinforcement of Concrete-Part 2: Ribbed Bars-Second Edition, International Organization for Standardization, 2007, 20 pp.
12 Natrella, M. G., Experimental Statistics, National Bureau of Standards Handbook 91, 1966.