• Title/Summary/Keyword: 체위측정

Search Result 54, Processing Time 0.025 seconds

SHRIMP Zircon Ages of the Basement Gneiss Complex in the Pyeongchang-Wonju Area, Gyeonggi Massif, Korea (명창-원주 지역의 경기육괴 기반암 편마암 복합체에 대한 SHRIMP 저어콘 연대 측정)

  • Song, Yong-Sun;Park, Kye-Hun;Seo, Jae-Hyeon;Jo, Hui-Je;Yi, Kee-Wook
    • The Journal of the Petrological Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.99-114
    • /
    • 2011
  • Precambrian gneiss complex in the Pyeongchang-Wonju area, which lies west of the Paleozoic sedimentary basin of the Yeongwol-Taebaek area, is being considered as a part of the Gyeonggi massif, but its ages of formation and metamorphic events are not well defined yet. In this study, SHRIMP zircon U-Pb ages were determined from the gneiss complex in the area, We obtained the discrete ages of magmatic (ca. 1960 Ma) and metamorphic (ca. 1860 Ma) events through the interpretation of the SHRIMP data based on the internal structures of zircons. These are almost the same to the ages of main intrusion and metamorphism reported from the Precambrian basements of Gyeonggi, Yeongnam and Nangnim massifs of the Korean Peninsula, Ages of 3200~3300 Ma, 2900 Ma, 2660 Ma, 2430 Ma, 2260 Ma, and 2080~2070 Ma obtained from inherited cores of studied zircons are also very similar to the frequently reported ages from the basement rocks of the Gyeonggi and Yeongnam massifs, Lower intercept age of about 270 Ma calculated from the rim data seems to indicate that the study area suffered from a late Paleozoic metamorphism (Okcheon Orogeny), but we need more reasonable and sufficient data to confirm it. According to the results of this study, it is suggested that the Bangnim group unconformably overlying the gneiss complex was deposited after the Paleoproterozoic granitic magmatism (ca. 1960 Ma) and metamorphism (ca. 1860 Ma).

A Comparison of Anthropomery and Nutrient Intakes of Rural Middle School Students Provided with and without National School Lunch Program (경상북도 의성군 농촌지역 급식교와 비급식교 중학생의 영양소 섭취 실태와 체조성과의 상관성에 관한 연구)

  • 장현숙;이옥이
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.10 no.2
    • /
    • pp.116-128
    • /
    • 2000
  • The purpose of this study is to analyze the nutrient intakes and growth development of rural middle school students provided with and without the national school lunch program(NSLP). The subjects consisted of 340 rural middle school students provided with(n=177) and without(n=163) NSLP. Anthropometric measurements were taken for body weight, height, triceps skinfold thickness and percentage of body fat, and nutrient intakes were assessed by food record method. The results of this study were summarized as follows: There was no significant difference in the height, body weight girls provided with (155.8cm 47.2kg) and without (156.0cm, 49.7kg) NSLP. Total energy intakes of boys were 2123kca1 in with NSLP and 1857kca1 in without NSLP. Total energy intakes of girls were 1913kca1 in with NSLP and 1814kca1 in without NSLP. Total daily energy was provided in the ratio of 19.1%, 39.8%, 32.4% and 8.7% by breakfast, lunch, dinner and snacks in the with NSLP and 17.5%, 32.0%, 34.8% and 15.7% in without NSLP, respectively. Phosphorus, vitamin A, vitamin E, ascorbic acid, thiamin, riboflavin, niacin intakes were above the RDA in with NSLP. In without NSLP, phosphorus, vitamin E, thiamin intakes were above the RDA. however, calcium. iron, vitamin A, vitamin B$_{6}$ were less than the RDA. The study showed that total daily energy and nutrient intakes were significantly higher in students provided with than without school-lunch. Thus, the school-lunch program is recommended and necessary to improve the nutritional status of middle school students.

  • PDF

Comparative Study on Body Fat Distribution in Korean and Japanese Young Female Subjects (한국과 일본여자의 체지방 분포에 관한 연구)

  • 김향숙
    • Journal of Nutrition and Health
    • /
    • v.26 no.5
    • /
    • pp.615-624
    • /
    • 1993
  • The body fat distribution and nutritional state of the Korean and Japanese young female subjects were compared. Three-day individually weighed, dietary intakes and anthropometric measurements were determinded in 48 Korean and 60 Japanese female students. 19 to 23 yr of age, from the divisions of nutritions. The body composition estimates were measured by bioeletrical impedance-total body water(BI-TBW) method. There were no significant difference between the Korean and Japanese young females in body size and body shape. The Korean young females had lower estimated total body fat and internal fat that calculated by BI-TBW method, but there was no great difference between the Korean and the Japanese in subcutaneous fat. In contrast, the Korean young females are reported to have the same total energy expenditure per day as the Japanes young females and the total energy intakes and carbohydrate energy intake ratio per day were significantly higher than those of the Japanese young females. The difference in body fat distribution and energy intakes in Korean, and the role of capsaicin in red pepper are discussed as a possible determinant of the internal fat in the Korean vs the Japanese.

  • PDF

Utilization of Tissue Compensator for Uniform Dose Distribution in Total Body Irradiation (전신방사선조사시 균등한 선량분포를 이루기 위한 조직보상체의 이용)

  • Park, Seung-Jin;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Nah, Byung-Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.233-241
    • /
    • 1994
  • Purpose : This study was performed to verify dose distribution with the tissue compensator which is used for uniform dose distribution in total body irradiation(TBI). Materials and methods : The compensators were made of lead(0.8mm thickness) and aluminum(1mm or 5mm thickness) plates. The humanoid phantom of adult size was made of paraffin as a real treatment position for bilateral total body technique. The humanoid phantom was set at 360cm of source-axis distance(SAD) and irradiated with geographical field size(FS) $144{\times}144cm^2(40{\times}40cm^2$ at SAD 100cm) which covered the entire phantom. Irradiation was done with 10MV X-ray(CLINAC 1800, Varian Co., USA) of linear accelerator set at Department of Therapeutic Radiology, Chonnam University Hospital. The midline absorbed dose was checked at the various regions such as head, mouth, mid-neck, sternal notch, mid-mediastinum, xiphoid, umbilicus, pelvis, knee and ankle with or without compensator, respectively. We used exposure/exposure rate meter(model 192, Capintec Inc., USA) with ionization chamber(PR 05) for dosimetry, For the dosimetry of thorax region TLD rods of $1x1x6mm^3$ in volume(LiF, Harshaw Co., Netherland) was used at the commercially available humanoid phantom. Results : The absorbed dose of each point without tissue compensator revealed significant difference(from $-11.8\%\;to\;21.1\%$) compared with the umbilicus dose which is a dose prescription point in TBI. The absorbed dose without compensator at sternal notch including shoulder was $11.8\%$ less than the dose of umbilicus. With lead compensator the absorbed doses ranged from $+1.3\%\;to\;-5.3\%$ except mid-neck which revealed over-compensation($-7.9\%$). In case of aluminum compensator the absorbed doses were measured with less difference(from $-2.6{\%}\;to\;5.3\%$) compared with umbilicus dose. Conclusion : Both of lead and aluminum compensators applied to the skull or lower leg revealed a good compensation effect. It was recognized that boost irradiation or choosing reference point of dose prescription at sternal notch according to the lateral thickness of patient in TBI should be considered.

  • PDF

Synthesis, Characterizations and Gas Separation Property of PBEM-PMMA-POEM Terpolymer Membranes (PBEM-PMMA-POEM 터폴리머 분리막의 합성, 분석 및 기체 분리 성능)

  • Park, Byeong Ju;Kim, Na Un;Park, Jung Tae;Kim, Jong Hak
    • Membrane Journal
    • /
    • v.28 no.2
    • /
    • pp.121-128
    • /
    • 2018
  • Terpolymers, which are chemical compounds composed of three different chemical compounds, have rarely been utilized for gas separation membranes. In this study, we demonstrate a simple process to fabricate a composite membrane for $CO_2/N_2$ separation based on a terpolymer synthesized from poly(2-[3-(2H-benzotriazol-2-yl)-4-hydroxyphenyl] ethylmethacrylate)(PBEM), poly(oxyethylene methacrylate)(POEM), and methyl methacrylate (MMA) via free radical polymerization. A solution of the as-synthesized PBEM-PMMA-POEM was coated onto a microporous polysulfone (PSf) support to form a composite membrane. The successful polymerization and the characteristics and morphology of the membrane were characterized by Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD) analysis, thermogravimetric analysis (TGA), and field emission scanning electron microscopy (FE-SEM). The gas permeance and $CO_2/N_2$ selectivity of the PBEM-PMMA-POEM terpolymer membrane were measured at $25^{\circ}C$. A maximum $CO_2/N_2$ selectivity of 30.2 was obtained at a $CO_2$ permeance of 57.4 GPU ($1GPU=10^{-6}cm^3$(STP)/($s\;cm^2\;cmHg$)).

Fabrication of Electrolyte for Direct Carbon Fuel Cell and Evaluation of Properties of Direct Carbon Fuel Cell (직접탄소 연료전지용 전해질 제조 및 직접탄소 연료전지 특성 평가)

  • Pi, Seuk-Hoon;Cho, Min-Je;Lee, Jong-Won;Lee, Seung-Bok;Lim, Tak-Hyoung;Park, Seok-Joo;Song, Rak-Hyun;Shin, Dong-Ryul
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.786-789
    • /
    • 2011
  • In order to estimate the possibility of applying electrolytes generally used in solid oxide fuel cells(SOFCs) to direct carbon fuel cells(DCFCs), properties of YSZ(yttria stabilized zirconia) electrolyte were evaluated. In this study, vacuum slurry coating method was adapted to coat thin layer on anode support substrate. After sintering the electrolyte at $1400^{\circ}C$ for 5hrs, microstructure was analyzed by using SEM image. Also, gas permeability and ionic conductivity were measured to find out the potential possibility of electrolyte for DCFCs. The YSZ electrolyte represented dense coating layer and low gas permeability value. The ionic conductivity of YSZ electrolyte was high over $800^{\circ}C$. After measurement of the electrolyte properties, direct carbon fuel cell was fabricated and its performance was measured at $800^{\circ}C$.

A Study on Prevalence of Obesity and Its Related Factors in Housewives Residing in Apartments in Taegu (대구시내 아파트 거주 주부들의 비만 실태와 비만 요인에 관한 연구)

  • 박갑선
    • Journal of Nutrition and Health
    • /
    • v.23 no.3
    • /
    • pp.170-178
    • /
    • 1990
  • The aim of the study was to investigate prevalence of obesity among housewives residing in apartments in Taegu city and any relationship of obesity with various factors. Hundred three housewives aged 30-49 years living in apartments (over 30 pyung) were interviewed for socio-economic status, food habit, food intake by a convenient questionnaire, and daily activity by the 24-hour recall. Their weight, height and triceps skinfold thickness were measured. The results were summarized as follows: 1) The percentages of subjects and their spouses with college and higher education were as much as 53.6% and 83.5%, respectively. The commonest family size was four members with two children. 2) The percentages of subjects classified as underweight, normal, overweight, and obesity according to relative body weight(RBW) were 4.9, 44.7, 24.3 and 26.2, respectively. Twenty four percent belonged to obese group according to body mass index(BMI$\geq$25). 3) Food habit score was 12.4 points in average and judged 'good'. The average of daily energy intake was 2247㎉ which corresponded to 112% of RDA and intakes of nutrients except iron exceeded RDA. The means of food habit score and energy intake were not significantly different among 4 groups. 4) Multiple regression analysis was tested to explain a relationship between fatness and various factors. The equation, BMI=25.216+(0.836$\times$family size)-(0.309$\times$education, years)-(0.00503$\times$household work time, minutes), indicates that fatness of housewives was related with family size(+), educational level(-) and household work time(-). These relationships were statistically significant(p<0.001) and R2 (coefficient of determination) was 0.237.

  • PDF

College Students' Attitude toward Body Weight Control, Health-related Lifestyle and Dietary Behavior by Self-perception on Body Image and Obesity Index (대학생의 체형인식과 비만도에 따른 체중조절 태도, 건강관련 생활습관 및 식행동)

  • Chin, Jeong-Hee;Chang, Kyung-Ja
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.10
    • /
    • pp.1559-1565
    • /
    • 2005
  • The Purpose of this study was to investigate college students' attitude toward body weight control, health-related lifestyle and dietary behavior by their perception on body image and obesity index. The subjects were 871 nation- wide college students (330 male and 541 female students) participating in a nutritional education program via internet- A cross-sectional survey was conducted using a self-administered questionnaire via internet. The data were analyzed by a SPSS 10.0 program. Height and weight (p < 0.05), and the distribution of obesity index (p < 0.001) showed significant differences between male and female college students. As for self perception on body image, the necessity of body weight control and the experience of efforts to change the body weight, there were significant differences between male and female college students (p < 0.001). There were significant differences among groups by obesity index in the hours of exercise (p < 0.01), drinking (p < 0.01) and smoking (P < 0.001). As for methods of body weight control, all the groups by obesity index thought that program of body weight control by diet company is the most desirable method. Therefore, we must recognize that it is hard to correct health problems resulting from wrong lifestyle and dietary behavior fixed during college life and prepare a system for college students to obtain correct lifestyle and dietary behavior.

Development of Anode-supported Planar SOFC with Large Area by tape Casting Method (테입캐스팅을 이용한 대면적 (100 cm2) 연료극 지지체식 평판형 고체산화물 연료전지의 개발)

  • Yu, Seung-Ho;Song, Keun-Suk;Song, Hee-Jung;Kim, Jong-Hee;Song, Rak-Hyun;Jung, Doo-Hwan;Peck, Dong-Hyun;Shin, Dong-Ryul
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.1
    • /
    • pp.41-47
    • /
    • 2003
  • For the development of low temperature anode-supported planar solid oxide fuel cell, the planar anode supports with the thickness of 0.8 to 1 mm and the area of 25, 100 and $150\;cm^2$ were fabricated by the tape casting method. The strength, porosity, gas permeability and electrical conductivity of the planar anode support were measured. The porosity of anode supports sintered at $1400^{\circ}C$ and then reduced in$H_2$ atmosphere was increased from $45.8\%\;to\;53.9\%$. The electrical conductivity of the anode support was $900 S/cm\;at\; 850^{\circ}C$ and its gas permeability was 6l/min at 1 atm in air atmosphere. The electrolyte layer and cathode layer were fabricated by slurry dip coating method and then had examined the thickness of $10{\mu}m$ and the gas permeability of 2.5 ml/min at 3 atm in air atmosphere. As preliminary experiment, cathode multi-layered structure consists of LSM-YSZ/LSM/LSCF. At single cell test using the electrolyte layer with thickness of 20 to $30{\mu}m$, we achieved $300\;mA/cm^2$ and 0.6V at $750^{\circ}C$

Effect of Posture on the Distribution of Pulmonary Ventilation in Patients with Increased Closing volume (폐쇄용적(Closing Volume)이 증가된 만성 폐질환 환자에서 체위에 따른 폐환기량의 변화)

  • Kim, Young-Tae;Kim, Mee-Kyung;Lim, Chae-Man;Koh, Youn-Suck;Kim, Woo-Sung;Ryu, Jin-Sook;Lee, Myung-Hae;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.6
    • /
    • pp.631-637
    • /
    • 1993
  • Background: In normal adults, ventilation is uneven and greater in the base than the apex of the lung in tidal volume breathing. However infants have fragile chest wall and reduced elastic recoil, resulting in easy closure of peripheral airways especially in the dependent portion of the lung. So ventilation in infants is greater in the apex than the base of the lung. We assumed that in adults whose closing volume is increased, dependent portion could be easily collapsed during tidal breathing and ventilation could be greater in the uppear than than the lower portion of the lung. Methods: We measured spirometry and closing volume(CV) in normal controls and in patients with chronic lung disease. Also we measured fractional distribution of ventilation at supine, left lateral and right lateral decubitus with $^{133}Xe$ ventilation scan in normal controls, patients with normal closing volume and patients with increased closing volume. Results: The subjects consisted of 7 normal controls(mean $age{\pm}SD$, $62.9{\pm}6.1$ years). 6 patients with normal CV($62.8{\pm}8.2$ years) and 7 patients with increased CV($63.0{\pm}15.3$ years). 1) Normal controls have mean(${\pm}SD$) FVC $104{\pm}11%$ of predicted value, $FEV_1\;120{\pm}16%,\;FEV_1/FVC\;112{\pm}5%$ and CV $86.9{\pm}12.5%$. Patients with normal CV have FVC $62{\pm}11%,\;FEV_1\;54{\pm}17%,\;FEV_1/FVC\;84{\pm}23%$ and CV $92.6{\pm}15.5%$. Patients with increased CV, have FVC $53{\pm}9%,\;FEV_1\;38{\pm}13,\;FEV_1/FVC\;69{\pm}16%$ and CV $176.1{\pm}36.6%$, CV was significantly different between two patient groups(p<0.02) 2). In normal controls mean fractional ventilation to left lung was $48.1{\pm}5.3%$ at supine, $54.1{\pm}9.8%$ at dependent and $40.9{\pm}6.5%$ at left uppermost position. In patients with normal CV mean fractional ventilation to left lung was $44.6{\pm}2.1%$ at supine, $59.7{\pm}5.6%$ at left dependent and $31.7{\pm}8.3%$ at left uppermost position. In patients with increased CV mean fractional ventilation to left lung was $48.7{\pm}4.5%$ at supine, $41.7{\pm}6.6%$ at left dependent and $60.9{\pm}15.7%$ at left uppermost position. In normal controls and patients with normal CV, ventilation to left lung at left dependent position tends to be higher than that at supine position but without statisitical significance and it was significantly lower at left uppermost than at left lung dependent position. In patients with increased CV, ventilation to left at left dependent position tends to be higher than that at supine position but without significance and it was significantly higher at left uppermost than that at left dependent position. Conclusion: These data suggest that in patients with increased CV ventilation to one side of lung could be higher at uppermost than at dependent position on lateral decubitus during tidal breathing and this fact should be taken into account in positioning of patients with unilateral lung disease.

  • PDF