• Title/Summary/Keyword: 체류시간과 제거효율 관계

Search Result 14, Processing Time 0.03 seconds

Application and Evaluation of the Sheet Flow Channel for Water Quality Improvement in the Stream (하천 내 수질 개선을 위한 박층류 하도의 적용 및 평가)

  • Lee, Du Han;Kim, Myounghwan;Gu, Jung-Eun;Kim, Won
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.4
    • /
    • pp.208-216
    • /
    • 2019
  • This study investigated design factors and removal efficiencies of a sheet flow channel as natural type water improvement techniques in the stream. The channel was designed considering the design factors, then constructed and monitored in the test bed of the Osan stream's floodplain. Water lever, velocity, discharge, T-P, T-N, and NO3-N were monitored and the removal efficiencies and design formula were suggested. Overall efficiencies of T-P, T-N, and NO3-N range 10 - 20%, and they show consistent relations with residence times. Minimum velocity requirement is also suggested from the relation of algae conditions and velocities. Relation formula of residence time and removal efficiency will be applicable in the design and operation process of a sheet flow channel.

Optimization for SBR Process of Two-Sludge Type (Two-sludge 유형 SBR 공정의 최적 운영 조건 도출)

  • Ryu, Hong-Duck;Hwang, Jae-Sik;Kim, Keum-Yong;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.2
    • /
    • pp.229-234
    • /
    • 2007
  • In the present work, the sequencing batch reactor process of two-sludge type was optimized. The effects of solid retention time, hydraulic retention time, length of biosorption phase and temperature variation were investigated, respectively. In the T-N removal, the long solid retention time was favored. It was speculated that SCOD biosorption efficiency was higher in long solid retention time than in short solid retention time. In the comparison of hydraulic retention time, the removal efficiency of $NH_4^+-N$ and T-N were almost same in all applied hydraulic retention times which were 8 hr, 10 hr and 15 hr. It was observed that there was no need to have the hydraulic retention time more than 20 min in biosorption phase for enhancement of T-N removal efficiency. An experimental comparison of removal efficiencies with different temperature conditions was carried out. Decrease of temperature didn't affect the performance of the process, however, phosphorus removal efficiency was a little higher at low temperature than high temperature. Consequently, the process developed in this study was much amenable to wastewater treatment which was conducted in the low temperature and high loading rate.

Development of Biofilter System to Ammonia Removal exhausted from Livestock Facilities (축사내 암모니아 제거를 위한 바이오필터 시스템 개발)

  • 조성인;김명락;여운영
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.383-388
    • /
    • 2002
  • 본 연구에서 구성한 바이오필터 시스템은 암모니아 가스를 대상으로 여러 조건에서 성능을 구명하였으며, 필터 설계시 중요 인자인 송풍량, 온도, 함수율, 압력강하, 체류시간들간의 관계를 구명하였다. 필터 내부의 온도 변화는 체류시간 및 압력손실에 거의 영향을 주지 않았으며, 함수율의 변화가 체류시간과 압력손실에 미치는 영향은 함수율 값이 증가할수록 체류시간은 감소했으며 반대로 압력손실은 증가하는 결과를 보였다. 이는 필터 내부의 공극률 변화로 생긴 결과라 판단된다. 송풍량은 바이오필터 효율에 절대적으로 영향을 미치며 송풍량이 증가할수록 체류시간은 감소하며 초기 제거율도 떨어진다. 미생물의 투입 여부에 따른 제거율은 미생물 접종을 하지 않은 경우 초기 흡착에 의한 영향으로 제거율이 높다가 시간이 지남에 따라 차츰 낮아져 90% 이하로 떨어지는 경향을 보였고, 균주를 접종한 경우에 있어서는 시운전 기간 동안 거의 100% 가까운 제거 성능을 보였다. 본 연구는 실험실에서 암모니아 가스만을 대상을 하여 실험하였다. 따라서 실제 축사에서 발생하는 다양한 성분의 악취와 농도에 대한 성능 검증과 개선에 대한 연구가 보다 장기간에 걸쳐 이루어져야 할 것이다. 또한 소요되는 에너지와 운전비용의 절감 등의 유지관리, 바이오필터와 타 방식과의 조합, 그리고 다양한 전처리 방식의 개발 등 여러 측면에서 바이오필터 성능 개선에 대한 연구가 병행되어야 할 것으로 판단된다.

  • PDF

Retreatment of Arificial Wastewater by using Microalgae (조류를 이용한 인공하수의 재처리)

  • Lee, Young-Joon;Lee, Soo-Hyung
    • Korean Journal of Ecology and Environment
    • /
    • v.35 no.2 s.98
    • /
    • pp.133-140
    • /
    • 2002
  • This study was performed in lab scaled oxidation pond. The removal efficiency of pollutant on the influence of changes of hydraulic retention time and pond style was investigated. The correlation between organic removal efficiency and dissolved oxygen concentration on algal photosynthesis showed the light time revealed a higher relationship more than the dark time, and the squares of the correlation coefficient of 15 days retention time were higher than that of 5 days in single pond. The variation of dissolved oxygen concentration of a series pond was from 4.2 to 19.8 mg/l under 5 days retention time, the concentration of dissolved oxygen increased with increasing step of series pond. Between the single pond and a series of pond system, a series of pond system showed better organic removal efficiency. Average removal efficiency range of $TBOD_5$ and $SBOD_5$ was $49{\sim}83%$ and $87{\sim}92%$, respectively. Algae should be removed appropriately to increase the removal efficiency of organic matter.

Effects of Detention Time and Disc Speed on the Treatment Efficiencies of RBC (체류시간(滯留時間)과 원판회전속도(圓板回轉速度)가 회전원판생물막법(回轉圓板生物膜法)의 처리효율(處理効率)에 미치는 영향(影響))

  • Kim, Sang Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.3
    • /
    • pp.1-9
    • /
    • 1984
  • A mult-stage rotating biological contactor process was evaluated by using the mixtures of nightsoil and sewage as influent substrate. An emphasis was concentrated on the BOD removal efficiency at each stage of the process with respect to hydraulic detention times, rotating speeds of the disc and influent organic substrate concentrations. The results indicated that the process was found to be economically feasible when operated at hyduraulic detention time of 2 hours and disc rotating speed of 3 RPH. As to treatment efficiency, BOD removal efficiency of 40 to 50 percent could be obtained at the first stage regardless of influent organic substrate concentrations. The overall BOD removal efficiency of the process was found to be 88 to 90 percent at even high organic loading of $2.0kgBOD/m^3{\cdot}day$.

  • PDF

Nitrogen Removal Characteristics in Two-Sludge System of SBR Type Using Sewage Wastewater of Low C/N Ratio (낮은 C/N 비에서 운영되는 SBR 유형의 Two-Sludge 공정의 질소 제거 특성)

  • Ryu, Hong-Duck;Kim, Hak-In;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.7-14
    • /
    • 2006
  • In this study, nitrogen removal characteristics of SBR3 process, which is two-sludge system of sequencing batch reactor(SBR) type, were investigated, with comparison of those of SBR1 process, which is conventional SBR process, and SBR2 process, which was designed to enhance denitrification efficiency through step-feeding of wastewater, using domestic wastewater. SBR3 process of two-sludge type can perform external nitrification, on which nitrification occurs in separated reactor, and enhanced denitrification using biosorbed organics. In the results with domestic wastewater, T-N removal efficiency of SBR3 process was better than those of SBR1 and SBR2 processes. It was observed that bigger difference of T-N removal efficiency between SBR3 process and SBR1 & SBR2 processes was showed at low C/N ratio than that at high C/N ratio resulting from more efficient use of organics by biosorption mechanism in denitrification of SBR3 process than those of SBR1 and SBR2 processes. In addition, T-N removal efficiency of SBR3 process according to influent T-N loading rate was better than those of SBR1 and SBR2, even though influent T-N loading rate of SBR3 process was higher than that of SBR1 and SBR2 process resulting from operation of SBR3 process in short hydraulic retention time(HRT) by external nitrification.

Purification Characteristics and Hydraulic Conditions in an Artificial Wetland System (인공습지시스템에서 수리학적 조건과 수질정화특성)

  • Park, Byeng-Hyen;Kim, Jae-Ok;Lee, Kwng-Sik;Joo, Gea-Jae;Lee, Sang-Joon;Nam, Gui-Sook
    • Korean Journal of Ecology and Environment
    • /
    • v.35 no.4 s.100
    • /
    • pp.285-294
    • /
    • 2002
  • The purpose of this study was to evaluate the relationships between purification characteristics and hydraulic conditions, and to clarify the basic and essential factors required to be considered in the construction and management of artificial wetland system for the improvement of reservoir water quality. The artificial wetland system was composed of a pumping station and six sequential plants beds with five species of macrophytes: Oenanthe javanica, Acorus calamus, Zizania latifolia, Typha angustifolia, and Phragmites australis. The system was operated on free surface-flow system, and operation conditions were $3,444-4,156\; m^3/d$ of inflow rate, 0.5-2.0 hr of HRT, 0.1-0.2 m of water depth, 6.0-9.4 m/d of hydraulic loading, and relatively low nutrients concentration (0.224-2.462 mgN/L, 0.145-0.164 mgP/L) of inflow water. The mean purification efficiencies of TN ranged from 12.1% to 14.3% by showing the highest efficiency at the Phragmites australis bed, and these of TP were 6.3-9.5% by showing the similar ranges of efficiencies among all species. The mean purification efficiencies of SS and Chl-A ranged from 17.4% to 38.5% and from 12.0% to 20.2%, respectively, and the Oenanthe javanica bed showed the highest efficiency with higher concentration of influent than others. The mean purification amount per day of each pollutant were $9.8-4.1\;g{\cdot}m^{-2}{\cdot}d^{-1}$ in BOD, $1.299-2.343\;g{\cdot}m^{-2}{\cdot}d^{-1}$ in TN, $0.085-1.821\;g{\cdot}m^{-2}{\cdot}d^{-1}$ in TP, $17.9-111.6\;g{\cdot}m^{-2}{\cdot}d^{-1}$ in SS and $0.011-0.094\;g{\cdot}m^{-2}{\cdot}d^{-1}$ in Chl-a. The purification amount per day of TN revealed the hi링hest level at the Zizania latifolia bed, and TP showed at the Acrous calamus bed. SS and Chl-a, as particulate materials, revealed the highest purification amount per day at the Oenanthe javanica bed that was high on the whole parameters. It was estimated that the purification amount per day was increased with the high concentration of influent and shoot density of macrophytes, as was shown in the purification efficiency. Correlation coefficients between purification efficiencies and hydraulic conditions (HRT and inflow rate) were 0.016-0.731 of $R^2$ in terms of HRT, and 0.015-0.868 of $R^2$ daily inflow rate. Correlation coefficients of purification amounts per day with hydraulic conditions were 0.173-0.763 of Ra in terms of HRT, and 0.209-0.770 daily inflow rate. Among the correlation coefficients between purification efficiency and hydraulic condition, the percentages of over 0.5 range of $R^2$ were 20% in HRT and in daily inflow rate. However, the percentages of over 0.5 range of correlation coefficients ($R^2$) between purification amount per day and hydraulic conditions were 53% in HRT and 73% in daily inflow rate. The relationships between purificationamount per day and hydraulic condition were more significant than those of purifi-cation efficiency. In this study, high hydraulic conditions (HRT and inflow rate) are not likely to affect significantly the purification efficiency of nutrient. Therefore, the emphasis should be on the purification amounts per day with high hydraulicloadings (HRT and inflow rate) for the improvement of eutrophic reservoir withrelatively low nutrients concentration and large quantity to be treated.

Biosorption Characteristics of Organic Matter in a Sequencing Batch Reactor : Effect of Sludge Retention Time (연속 회분식 반응기내 유기물 생물흡착특성: SRT 영향)

  • Kim, Keum-Yong;Kim, Jin-Hyung;Kim, Dae-Keun;Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.175-180
    • /
    • 2008
  • The objective of this study was to investigate biosorption of organic matter on EPS(Extracellular Polymeric Substances) at different SRT(Sludge Retention Time) in a SBR(Sequencing Batch Reactor) process, which was operated with the following operation steps : Fill-React-Settle-Decant-Idle. The hydraulic retention time was set to be 24 hours. The results obtained from this study showed that the organic removal efficiency per unit microbial biomass decreased with increasing SRT, and the corresponding EPS amount also did. The percent removal of organic by biosorption increased with SRT, and it reached to 53.2% at SRT of 30 days. However, the highest biosorption per microbial biomass(48.6 mgCOD/gVSS) was found at SRT of 2 days. The EPS analysis was performed by measuring TSS, TCOD$_{Cr}$, and TKN. The EPS production per unit microbial biomass was observed to be high at a low SRT. Due to the above result, the floc formation was hindered and therefore poor settlement of sludge resulted in decreasing the COD removal efficiency. It was therefore concluded that the consideration of the system design should include the characteristic of EPS as well as other factors such as SRT, MLSS, and organic loading.

Correlation between operation factors and nitritation using anaerobic digester supernatant at ordinary temperature (상온 조건에서 혐기 소화 상징액을 이용한 아질산화 반응과 운전 인자의 상관성 분석)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.244-249
    • /
    • 2016
  • Anaerobic digester supernatant including high concentrations of nitrogen is recycled to water treatment line and make pollutant load increase in municipal wastewater treatment plant(MWTP). To treat nitrogen in anaerobic digester supernatant is suggested the method of MWTP retrofit. In this study, the lab scale reactor was operated about 200 days using supernatant of anaerobic digester. The results could draw operation condition that ammonium nitrogen removal efficiency more than 90% and nitrite conversion efficiency over 70%. Correlation between operation efficiency and operation factors was analyzed based on the operation results. Ammonium nitrogen remove efficiency and nitrite conversion efficiency were related to solid retention time (SRT), ammonium nitrogen load and ammonium nitrogen loading per unit mixed liquer suspended solid (MLSS). Results of this study can be used effective data on nitritation of supernatant of anaerobic digester, and be expected to increase availability of nitritation.

An Experimental Study for Practical Application of RBC (RBC의 실제적용(實際適用)을 위한 실험연구(實驗硏究))

  • Kim, Hee-Jeong;Ahn, Yong-Tae
    • Korean Journal of Environmental Agriculture
    • /
    • v.4 no.1
    • /
    • pp.37-42
    • /
    • 1985
  • Recently the method using fixing biological contactor in treatment of sewage and wastewater has been propelling on the ground that it has advantages of reducing both motive and man power and applied treatment plants of this method are increasing gradually in Korea. After analysing the results from which real structure pilot plant had operated in the field with RBC sewage wastewater system-one of the fixing biological contact methods-for five months, this study was performed to investigate how to apply the standard of establishment that provided in article of sewage disposal facilities notified (act 8 of art 84) by the office of environment on May 16, 1984, to real treatment plant. The rotating velocity and the staying time of rotating disc have interrelation on removal efficiency of BOD. When circumferential velocity of rotating disc was ranged from 18 to 20 m per minute, economical price was the best. When the staying time was even about 120 minutes for that of home RBC facilities showed 90% or above of BOD removal efficiency of high concentration sewage also showed excellent efficiency ranged from about 85% to 90%.

  • PDF