격자형 용접 띠철근으로 보강된 콘크리트 기둥의 해석적 접근 (Analytical Approach on the Concrete Columns with Welded Reinforcement Grids)

  • 최창식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권1호
    • /
    • pp.137-146
    • /
    • 1999
  • Analysis of R/C columns requires modeling of the plastic hinge region, as well as nonlinear material characteristics. This becomes a challenging task in view of the nonlinearity of both steel and concrete. Furthermore, formation and progression of plasticity in the hinge is a difficult phenomenan to simulate, especially under reversed cyclic loading and decaying strength conditions. This research provide one analytical model employed in column analysis, including the analysis procedure for establishing inelastic force-deformation relationships. The analytical results show good correlation with experimental data. The employed procedure with the adopted analytical models can be used to compute inelastic displacements of concrete columns with welded reinforcement grids. The inelastic deformability beyond the peak was similar to those indicated by columns with conventional ties. The superior performance of columns with welded grids may be attributed to the improved confinement characteristics of grids associated with increased rigidity of welded ties.

  • PDF

시공단계를 고려한 고층건물 콘크리트 슬래브의 건조수축 응력해석 (Shrinkage Stress Analysis of Concrete Slab in Multi-Story Building Considering Construction Sequence)

  • 김한수;정종현;조석희
    • 콘크리트학회논문집
    • /
    • 제13권5호
    • /
    • pp.457-465
    • /
    • 2001
  • 고층건물 콘크리트 슬래브에 발생하는 건조수축변형은 기둥이나 벽체 등의 구조부재에 의해 변형발생이 제한되고 이로 인한 인장응력이 부재의 인장강도를 초과하게 되면 균열이 발생한다. 이 논문에서는 건조수축과 크리프, 철근효과 등 콘크리트의 재료특성과 시공단계에 따른 건조수축을 고려하여 슬래브에 발생하는 응력을 산정하는 실용적인 해석방법을 제안하였다. 건조수축으로 인해 부재에 작용하는 인장응력은 건조수축변형을 등가온도하중으로 치환하여 계산할 수 있으며, 건조수축과는 달리 응력을 이완시켜 주는 크리프의 영향은 콘크리트의 탄성계수 Ec 대신에 크리프를 고려한 콘크리트의 유효탄성계수 E eff를 사용하고, 배근된 철근은 등가의 보요소로 모델링하여 해석에 반영할 수 있다. 또한 고층건물 슬래브에서 발생하는 건조수축응력은 그 층에서 발생한 건조수축량과 하부 층의 건조수축량의 차이인 유효건조수축에 의한 응력임을 고려하여 각 시공단계마다 발생하는 응력을 단계별 해석을 수행하여 구하고 이를 합산함으로서 슬래브에 최종적으로 발생하는 응력을 산정한다. 10층 규모에 예제건물을 대상으로 해석한 결과, 상부 층으로 갈수록 점차 건조수축응력이 줄어들며 전체 구조물에 발생한 응력은 저층부(1~2층)에서는 기준강도를 초과하나 3층 이상의 고층부에서는 기준강도의 27.9~92.8% 수준으로 나타났다.

기둥의 철근비와 축변형량이 보 해석에 미치는 영향 연구 (Effect of Longitudinal Reinforcement Ratios and Axial Deformation on Frame Analysis in RC Columns)

  • 장원석;민창식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.477-482
    • /
    • 2001
  • This paper is to study the effect of longitudinal reinforcement ratios and axial deformation on the frame analysis in reinforced concrete(RC) columns and to investigate the effect of confined concrete core, the length-width ratio and longitudinal steel ratios on frame analysis in Concrete-Filled steel Tubular(CFT) columns. An equation if derived to evaluate the modulus of elasticity for core concrete. The 34 reference data have been collected for the purpose and are processed by the mean of a multiple regression analysis technique. The equation and longitudinal reinforcement ratios was applied to RC columns for structural analysis. Then, the difference of beam moment was identified. In general, the results of analysis was indicated reasonable differences in beam moment, in case of longitudinal reinforcement ratios applied to RC columns when compared with the plain concrete columns. In CFT columns the equation was also applied in order to the effect of confined concrete core on structural analysis. Beam moment was increased as volumetric ratio of lateral steel was decreased. The effect of longitudinal steel ratios was investigated in CFT columns and was confirmed beam moment variety. The result was appeared reasonable difference in beam moment as longitudinal steel was increased.

  • PDF

철근콘크리트조 4층 골조건물의 강제진동실험 (Forced Vibration Testing of a Four-Story Reinforced Concrete Frame Building)

  • 유은종
    • 한국지진공학회논문집
    • /
    • 제11권2호
    • /
    • pp.27-38
    • /
    • 2007
  • 노스리지 지진에 의해 손상을 받은4층 철근콘크리트조 골조건물을 대상으로 선형가진기 및 대용량의 편심가진기를 이용한 강제진동실험과 상시미진동 측정을 실시하였다. 미진동 가속도데이터 및 선형가진기에 의한 백색잡음 실험시의 가속도데이터로부터 구조물식별을 수행하여 7차모드까지의 고유진동수 및 모드감쇠비를 얻었다. 두대의 대용량 편심가진기를 사용하여 얻은 큰 진폭의 조화 진동하에서는 가속도데이터를 사용하여 각 방향 1차모드를 식별하였으며 변위계와 변형게이지를 이용하여 층간변위각, 기둥과 슬래브와 같은 구조부재의 곡률분포를 측정하였다. 각 경우 고유진동수는 진동의 크기가 클수록 낮아졌다. 즉, 편심가진기가력시 고유진동수는 상시미진동시에 비해 $70{\sim}75%$, 선형가진시가력시에 비해 $92{\sim}93%$ 정도로 낮게 나타났다. 이러한 진동수의 감소폭은 지진에 의해 큰 손상을 받았던 건물의 남북방향에서 크게 나타났다.

강한 기둥-약한 보로 설계된 철근 콘크리트 골조구조의 변형성능 평가에 관한 연구 (Evaluation on the Deformation Capacity of RC Frame Structure with Strong Column-Weak Beam)

  • 서수연;이리형;진세옥;최윤철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.225-233
    • /
    • 2003
  • 최근 성능에 근거한 설계법의 개발과 더불어, 변위설계에 대한 관심이 증가하고 있다. 본 연구에서는 다층 RC 골조의 변위성능을 보다 정확하게 평가할 수 있는 방법을 제시하고자 한다. 이를 위해, 골조의 횡변위를 계산하기 위해서 보와 기둥의 변형뿐만 아니라 정착부와 조인트 부분의 변형을 변위 산정시 고려하였다. 기존의 실험 및 계산결과의 비교로부터, 본 연구에서 제시한 방법의 적합성을 확인하였고, 이를 강한 기둥-약한 보의 설계개념을 설계된 다층 RC골조 건물에 적용하여 그 거동을 예측하였다. 그 결과, 보다 정확한 건물의 변위성능을 평가하기 위해서는 정착부와 조인트의 변형을 반드시 반영하여야 하는 것으로 나타났다.

고장력 철근이 적용된 철근콘크리트 보-기둥 접합부 파괴모드에 대한 실험적 연구 (Experimental Study on Seismic Performance of Beam-column Connections with High Strength Reinforcements)

  • 김대훈;박아론;이기학
    • 한국공간구조학회논문집
    • /
    • 제16권2호
    • /
    • pp.61-68
    • /
    • 2016
  • Behavior of RC(Reinforced-concrete) beam-column connections has been subjected to the earthquake loading has been determined by shear and attachment mechanism. However, since the shear and attachment are very fragile for cycle loadings. Through occurring plastic hinges at the beam, the column and the connection should remain elastic condition and the beam should dissipate the energy from the earthquake. This study was investigate on the seismic performance of 6 RC beam - column connections built with the high strength reinforcements (700MPa) based on design and detailing requirements in the ACI 318-05 Provision and KCI-07 appendix II. This is aimed to evaluate the effect of the high-strength reinforcements as used the beam-column connection members. The main comparisons were the seismic performance of the connections affect the seismic performance in terms of strength, stiffness and ductility, joint shear stress-strain. A total of 6 beam-column specimens were built with a 1/2 scale and subjected to the cyclic loadings. Main design considerations were the area of the longitudinal reinforcements of the beam and details of the beam-column joint designed based on the seismic code. Cyclic test results are given and recommendations for the usage of high strength reinforcements for the seismic design is provided.

낮은 압축력을 받는 철근콘크리트 기둥의 내진성능에 대한 띠철근 상세의 영향 (Effects of Tie Details on Seismic Performance of RC Columns Subjected to Low Compression Loads)

  • 김철구;박홍근;엄태성;김태완
    • 한국지진공학회논문집
    • /
    • 제19권4호
    • /
    • pp.195-205
    • /
    • 2015
  • Various non-seismic tie details are frequently used for one- and two-story small buildings because the seismic demand on their deformation capacities is not relatively significant. To evaluate the effects of the non-seismic tie details on the seismic performance of reinforced concrete columns, six square columns with a cross section of $400{\times}400mm$ and six rectangular columns with a cross section of $250{\times}640mm$ were tested. The anchorage details at both ends and spacing of tie hoops, along with the cross-sectional shape and the magnitude of axial load, were considered as the primary test parameters. Test results showed that square columns had higher stiffness and lower lateral deformation rather than rectangular columns. Both lap spliced tie and U-shaped tie provided comparable or improved seismic performance to $90^{\circ}$ hook tie in terms of maximum strength, ductility, and energy dissipation. The predicted curves with modeling parameters in ASCE41-13 were conservative for test results of lap spliced tie and U-shaped tie specimens since plastic behavior after flexural yielding could not be considered. For economical design, ASCE41-13 should be revised with various test results of tie details.

비선형 동적 해석을 이용한 비내진 상세 RC 골조의 지진거동 특성 분석 (A Study on the Seismic Response of a Non-earthquake Resistant RC Frame Using Inelastic Dynamic Analyses)

  • 정성훈;이광호;이수권
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.381-388
    • /
    • 2010
  • 이 논문에서는 내진상세가 적용되지 않은 RC골조의 지진 거동 특성을 파악하였다. 해석 대상 건물은 내진 규준의 적용을 받지 않고 중력하중만을 고려하여 설계되었다. 원형철근이 주철근으로 사용되었으며, 부재는 낮은 수준의 전단력을 견딜 수 있는 최소한의 스터럽이 사용되어 코어 부분의 구속효과는 거의 없다. 평면비정형성을 가진 건물의 경우, 푸쉬오버 해석을 통해서는 비틀림으로 인한 평면상에서 연단부의 손상집중을 파악할 수 없으므로 비선형 동적해석을 사용하는 것이 바람직하다. 섬유요소를 이용한 비선형 동적해석은 양방향 지진하중과 비틀림 거동의 영향을 받는 RC골조의 거동을 성공적으로 예측할 수 있었다. 하지만, 보다 진보된 응답 예측을 위해서는 부착 미끄러짐과 같은 보-기둥 접합부의 국부거동을 정밀하게 나타내는 모델링 요소의 개발이 필요하다.

프리캐스트 프리스트레스트 콘크리트 역티형보의 댑단부 전단거동 (Shear Behavior of Precast Prestressed Inverted-Tee Concrete Beams with Dapped Ends)

  • 유승룡
    • 콘크리트학회논문집
    • /
    • 제13권1호
    • /
    • pp.46-53
    • /
    • 2001
  • 본 연구에서는 PCI 방법으로 설계한 직사각형보의 댑 전단거동을 구명키 위해 실물 크기의 두 개의 보 네 개의 댑단부에 대하여 실험하였다. 적용된 설계 활하중 500kgf/$m^2$은 주차장, 1,200kgf/$m^2$은 매장을 위한 국내설계기준이다. 보의 하단폭은 5층 정도의 매장 또는 주차장건물의 하부 기둥크기와 동일하게 60cm로 하였고, 댑의 깊이는 PCI에서 허용하는 최대치 내에서 하부 플랜지높이의 절반을 적용하였다. 대상 실물 실험체는 PCI 설계에 충분히 만족하도록 설계하였으나, 네 개의 실험체중 활하중 1200kgf/$m^2$를 위한 두 개의 실험체는 사용하중이전에 초기균열이 발생되었고 예측강도에 훨씬 못 미치는 하중에서 니브의 수직 전단파괴에 의하여 종국파괴되었다. 니브 수직전단파괴를 일으킨 활하중 1200kgf/$m^2$실험체의 최종 파괴강도는 77.22tonf과 78.36tonf으로 PCI의 81.9tonf과 ACI의 65.62tonf 사이 값으로 ACI의 예측식에 상회하나 PCI 제안 값에 미달하여 발생하였으므로 ACI제안 방식이 안전적인 측면을 고려할 때 더 합리적인 것으로 사료된다. 모든 하중-변형률곡선에서 걸이철근(Ash)의 변형률이 항복변형률에 도달할 정도로 가장 두드러졌다. 강도를 개선하기 위하여 추가적인 경사 걸이 철근이 필요한 것으로 판단된다.

U-형 복합보의 춤 변화에 따른 구조성능에 관한 실험적 연구 (An Experimental study on the Structural Performance by the Depth Variation of Capacity of U-shaped composite Beam)

  • 하상수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권5호
    • /
    • pp.111-118
    • /
    • 2020
  • 본 연구에 사용된 U-형 복합보는 슬래브는 철근콘크리트구조로 되어 있고, 슬래브를 지지해 주는 보는 철골구조와 철근콘크리트구조, 그리고 U-형 강판으로 이루어져 있다. U-형 복합보는 시공성이 우수하고 낮은 층고와 장경간이 가능하기 때문에 공작물 주차장으로 사용하기 위한 목적으로 개발되었다. 시공성 향상을 위해 U-형 복합보 단부는 규격화된 H형강으로 계획하여 기둥에 직접 접합시키고, 강재 물량을 감소시키기 위해 U-형 복합보의 중간 부분에는 H형강 대신 얇은 강판(t=6)을 사용하여 U자형 형태로 접은 U-형 강판으로 구성되어 있다. U형 강판이 위치하는 복합보 중앙부에는 보의 춤을 작게 계획함으로서 공작물 주차장의 제한 높이에 만족하도록 계획할 수 있다. 낮은 보의 춤은 층고 단축에는 유리하지만 휨성능에는 저해 요인이 되기 때문에 춤 변화에 따른 구조성능을 파악하는 것이 중요하다. 또한, U-형 복합보는 철골구조와 철근콘크리트구조 및 U-형 강판이 혼합되어 있기 때문에 일체성 확보가 구조성능을 확보하는데 큰 영향을 준다. 따라서 본 연구에서는 U-형 복합보의 춤을 변화에 따른 구조성능을 파악하기 위한 구조실험을 실시하였다. 실험체는 일반주차장용으로 계획된 실험체를 기준실험체로 하여 춤을 변화시킨 2개의 실험체를 포함하여 총 3개를 계획하였다. 실험결과 춤을 크게 계획한 실험체가 기준실험체보다 항복강도, 최대강도, 에너지 등 구조성능이 우수하게 나타났다.