Browse > Article
http://dx.doi.org/10.11112/jksmi.2020.24.5.111

An Experimental study on the Structural Performance by the Depth Variation of Capacity of U-shaped composite Beam  

Ha, Sang-Su (Division of Real Estate and Construction Engineering(Department of Architectural Engineering))
Publication Information
Journal of the Korea institute for structural maintenance and inspection / v.24, no.5, 2020 , pp. 111-118 More about this Journal
Abstract
The U-shaped composite beam used in this study consist of a reinforced concrete structure, a beam steel structure supporting the slab, a reinforced concrete structure, and a U-shaped steel plate. The U-shaped composite beam was developed for the purpose of using it as a parking lot because it is highly constructible and has low floor height and long span. For the improvement of constructivity, the U-shaped composite beam ends are planned with standardized H-shaped steel and connected directly to the columns, and the middle of the U-shaped composite beam consists of U-shaped steel plates folded in U-shaped form using thin steel plates (t=6) instead of H-shaped steel. In the middle of the composite beam, where U-shaped steel plates are located, the depth of U-shaped beam may be planned to be small so as to satisfy the height limit of the parking lot. It is important to grasp the structural performance according to the change of depth because low beam depth is advantageous for the reduction of the floor height, but it is a inhibitor to the structural behaviors of U-shaped composite beam. In addition, since U-shaped composite beams are a mixture of steel frame structures, reinforced concrete structures and U-shaped steel plates, securing unity has a great influence on securing structural performance. Therefore, in this study, a structural experiment was conducted to understand the structural performance according to the depth change for U-shaped composite beam. A total of three specimens were planned, including two specimens that changed the depth using a criteria specimen planned for a general parking lot. The results of the experiment showed that the specimens who planned the depth greatly had better structural performance such as yield strength, maximum strength, and energy than the standard specimen.
Keywords
U-shaped composite beam; Depth; Unity; Structural performance;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 KDS 41 31 00 Building structure standards (2019), Design Code of builking steel structrues, https://www.kcsc.re.kr.
2 Jang Dongchan, Kim Teakseong Compilation (2019), Explanation of Building Construction Ordinance, kimoondang, pp. 630-633.
3 Yun-Cheul Choi, Sang-Sup Lee, Hyun-Ki Choi, Keum-Sung Park(2017), Behavior Characteristics of U-Shape Wide Composite Beam, Journal of the Korea Institute for Structural Maintenance and Inspection, Vol. 21, No. 5, September, pp. 125-133.   DOI
4 Dong-Kwan, Kim, Byoung-Chan, Lee, Seung-Hwan, Lee (2016), Structural Capacity and Constructability of Composite Concrete Members(TSC beam & PSRC column), Magazine of the Korea Concrete Institute, Vol. 28, No. 5, September, pp. 36-42.
5 ACI 318M-14 (2014), Building Code Requirements for structural concrete and commentary, American Concrete Institute, pp.129-150.
6 Architectural Institute of Korea. (2016), Korea Building Code and Commentary, Gimoon-Dang Press.
7 Shin, H. S., Heo, B. W., Bae, K. W., and Kim, K. H. (2008), Analysis of the Load Carrying Behavior of Shear Connection at the Interface of Encased Composite Beams, Journal of Korean Society of Steel Construction, 20(1), 67-79.
8 Eivind Hognestad, Norman W. Hanson, and Douglas McHenryc (1995), Concrete Stress Distribution in Ultimate Strength Design, ACI Journal, Proceedings, Vol.52, NO.4, December, pp. 475-479.