• Title/Summary/Keyword: 천장효과

Search Result 65, Processing Time 0.027 seconds

Glass ceiling in arts and culture professionals: Between J and R industries (문화예술분야 전문인력에 대한 유리천장효과 분석: J산업과 R산업 중심으로)

  • Chan, Jong-Sub;Heo, Shik
    • Review of Culture and Economy
    • /
    • v.21 no.2
    • /
    • pp.3-28
    • /
    • 2018
  • This study focuses on analyzing the glass ceiling effect in arts and culture professionals through the quintile decomposition applied to the RIF unconditional quantile regression and Oaxaca-Blinder decomposition technique. From the industrial viewpoint, we divide arts and culture professionals into cultural contents professionals(large category J industry) and arts professionals(large category R industry). For our analysis, we employ the pooling data of 'Wage Structure Survey' from 2009 to 2016. Our results are summarized as follows. First, as OLS wage decomposition showed that the gender wage gap among the arts professionals was lower than cultural contents professionals, but the discrimination portion of total gender wage gap was larger. Second, from quintile regression decompositions, the glass ceiling effects of two types of professionals showed different results. Cultural contents sector was observed with the "steady glass ceiling effect" as the portion of the discrimination was continuously increased, while the arts sector was observed with the "limited glass ceiling effect" as the discrimination had drastically increased in the 80s and 90s.

Identification of Dynamic Characteristics and Numerical Analysis of Ceiling System Considering Collision Adjacent Structures (천장시스템의 동특성 식별 및 인접 구조물과의 충돌을 고려한 동적응답해석)

  • Jeon, Min-Jun;Ju, Bo-Geun;Cho, Bong-Ho;Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.4
    • /
    • pp.205-213
    • /
    • 2019
  • In the Pohang Earthquake in 2017, considerable damage to non-structural elements, such as ceiling systems, exterior finishes, and curtain walls, was reported; thus, the seismic designs of non-structural elements are important. In this study, the modal characteristics of a ceiling system were investigated through the impact hammer test. The frequency and damping ratio according to the length of the hanger bolt were identified. In addition, collision experiments were conducted to obtain the impact duration for exactly considering the impact effects of the ceiling against a wall or other adjacent elements. Based on the identified dynamics and impact duration of the ceiling system, the seismic responses of the ceiling system were obtained numerically in case of collision. Numerical simulation results show that the impact load tends to increase with the clearance between the ceiling and adjacent elements, and is not correlated with the length of the hanger bolt.

The Effect of Sling Lumbar Stabilization Exercise to Muscle Body Type and Subjective Pain Degree of Men Who Have Sacroiliac Joint Syndrome (8주간의 슬링을 이용한 요부안정화 운동이 천장관절 증후군 남성의 근체형 및 주관적 통증정도에 미치는 효과)

  • Baek, Soon-Gi
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.651-658
    • /
    • 2014
  • The purpose of this study is to see how the sling lumbar stabilization exercise affects muscle body type and subjective pain degree of 17 middle-age men who are diagnosed with sacroiliac joint syndrome and investigate the effectiveness. The subjects of this study are patients who have been diagnosed with sacroiliac joint syndrome through tests like X-ray in S Orthopedics in C City and have had chronic lumbar pain for more than 6 months and the before and after results about subjective pain degree through three dimension Moire Muscle Body Type Tester and subjective pain degree through VAS Pain Awareness after sling lumbar stabilization exercise 3 times a week, 30 minutes a time, total 24 times for 8 weeks have revealed the following: The change of muscle body type has been comprehensively improved in the statistics before and after the exercise and the subjective pain degree has also comprehensively decreased in the statistics. Therefore, sling lumbar stabilization exercise is proved to give positive affect to muscle body type and pain improvement of the patients with sacroiliac joint syndrome.

Effects of sound absorbent gypsum board in the ceiling on low-frequency heavyweight floor impact sound (흡음 석고보드 천장재에 의한 저주파 중량 바닥충격음의 저감 효과)

  • Song, Han-Sol;Ryu, Jong-Kwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.323-330
    • /
    • 2018
  • This study investigated effects of absorbent gypsum board in the ceiling on low-frequency heavyweight floor impact sound through sound absorption coefficient and floor impact sound measurement. The sound absorption coefficients were measured with sound absorbent gypsum board, glass wool on gypsum board, and a double panel absorbent gypsum board (absorbent gypsum board + glass wool + absorbent gypsum board). Result showed that the absorbent gypsum board had sound absorption coefficient of 0.1 ~ 0.7 from 200 and 630 Hz octave band. The sound absorption coefficient was increased in all frequency range by adding glass wool. Additional absorbent gypsum board increased sound absorption coefficient up to 250 Hz octave band, but decreased over 250 Hz. Heavyweight floor impact sounds were measured in test building for three materials above, gypsum board, and bare slab. Result showed that glass wool on gypsum board and a double panel absorbent gypsum board reduced by 3 dB ~ 4 dB (single number quantity) heavyweight floor impact sound. Comparing with bare slab condition, floor impact sound reduction was mainly found from 125 Hz to 500 Hz octave band, and the maximum reduction was shown in the 250 Hz octave band.

The Effect of the Combined Operation of Sprinkler and Vent Systems on the Smoke Control in a Horizontal Corridor (스프링클러와 배연설비의 통합작동이 수평통로의 연기제어에 미치는 영향)

  • Jeon Heung-Kyun;Choi Young-Sang;Choo Hong-Lok;Jang Jun-Young
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.70-89
    • /
    • 2005
  • Fire scenarios in a space $20.0m\;\times\;4.0m$ floor and 3.0m high were simulated by using computational fluid dynamics program (FDS 4.0.3) to investigate the effect of the combined operation of both sprinkler and vent systems, which are installed for cooling and blocking smoke which propagates beneath the ceiling of a horizontal corridor, on the temperature and smoke density of it. It was shown that the combined operation both sprinkler and vent systems was more effective than each operation for cooling and blocking smoke, the number of operating sprinklers was two because of corner effect of wall, and over-installed sprinklers deteriorated the effect of cooling and blocking smoke. This study showed that the case of two sprinklers and vent flow rate $3.0m^3/s$ in fire scenario was the most effective for cooling and blocking smoke. It was confirmed that the smoke downdrag occurs in operating sprinkler system, and the more smoke droplets produced by increasing fire size, the greater smoke downdrag occurred.

The Characteristics of $CO_2 $ Extinguishant Transfer According to the Nozzle Conditions of a Fixed Eire System (고정식 소화장치 노즐조건에 따른 $CO_2 $전달특성)

  • 박찬수;최주석;전철균
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.41-48
    • /
    • 2004
  • We have conducted a numerical simulation under three-dimensional unsteady conditions in order to analyze the characteristics of $CO_2 $;, extinguishant transfer by varying the location of the injection nozzle, which affects the effect of a $CO_2 $;, fire fighting system used in the form of fixed systems for the marine engine room. Flow fields and $CO_2 $;, concentration fields were measured according to the location of the injection nozzle. In the case of arranging the injection nozzle on the center of the ceiling, the low-normal concentration distribution was developed along the $CO_2 $;, jet due to the downward flow created by impinging ceiling jets in the symmetric plane. The concentration line reaches its peak due to the mass transfer of $CO_2 $;, at the comer.

Analysis of the End-Effect of Permanent Magnet Linear Synchronous Motor Energized by Partially Excited Primary Current (부분여자된 영구자석형 선형동기전동기의 단부효과 해석)

  • Jung, Sang-Yong;Chun, Jang-Sung;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.306-308
    • /
    • 2000
  • 부분여자된 영구자석형 선형동기전동기(PMLSM)의 단부효과를 고려한 특성을 나타낸다. 선형동기전동기의 고효율 운전을 위하여 전기자 권선을 가동자의 위치별 부분여자하였으며, 이와 더불어 양단부의 제한된 자석길이에 의한 단부효과를 나타낸다.

  • PDF

A study on the design of ensemble reflector in a concert hall (콘서트홀 무대반사판의 설계에 관한 연구)

  • Kim, Min Ae;Oh, Yang Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.356-362
    • /
    • 2018
  • Stage in classical shoebox type concert hall is placed and occupy one side of the hall and have much early reflections from surrounded walls and ceiling nearby. On the other hand stage in vinyard terrace concert hall, which is surrounded by terrace seats instead of walls and ceiling, has lack of early reflections which may cause lack of communications among the players. Vinyard hall stage is enclosed with terrace seats front walls, while the players located on the stage riser keep the walls off as the walls have limited heights. Ensemble reflector installed above the stage is an effective way for the players to monitor the sound produced on the stage. That may help achieving a good ensemble of the performance. Ensemble reflector over the stage of a large vinyard terrace hall of 2,000 seats was designed with the variables of the location, the shape and the area. The effectiveness of the ensemble reflector is verified with the parameter of stage support.

Vibration isolation effect of floor impact sound by ceiling structure (바닥충격음에서의 천장구조에 따른 진동절연 효과)

  • Lee, S.H.;Jeong, G.C.;Chung, J.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.257-260
    • /
    • 2004
  • This study aims to evaluate factors of ceiling structure influencing to the floor impact sound. For this reasons, we measured the vibration of ceiling and the floor impact sound by ceiling structure. The main results from this study are that ceiling structure makes worse to non-ceiling structure for an effect of air layer in heavy-weight floor impact sound. But it has an effect on light-weight floor impact sound about $2\sim8dB$.

  • PDF

Effects of Different Ventilation Systems on Rearing Growing-finisher and Indoor Environment in a High Rise Hog Building (고상식 돈사내에서 환기시스템별 환경조사 및 육성비육돈 사육 효과)

  • Yoo, Y.H.;Jeong, J.W.;Park, K.H.;Song, J.I.;Ko, Y.G.;Kim, S.W.;Lee, I.B.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.193-204
    • /
    • 2010
  • The goal of this study was to develop a high-rise hog building(HRHB) for growing-fattening stages. HRHB was two story building and was suitable for specific environment in Korea. Manure was treated in a first floor and pigs were raised on the slatted second floor. Three ventilation systems - 1) duct inlet to wall exhaust system(V1), 2) eave inlet to wall exhaust system(V2), and 3) ceiling inlet to wall exhaust system(V3) - were used. This experiment was conducted during winter and from summer to fall. Air temperature, air speed, ammonia, hydrogen sulfide in HRHB, and swine growth rate were measured. During winter, air temperature in V1 system tended to be slightly high without any effect of outside air temperature. Maximum temperature from summer to fall was between 33.4 and $33.8^{\circ}C$ and there was no significant difference among systems. Continuously measured daily temperature was lower in V2 system than other systems and the fluctuation of air temperature was high. Air speed in V1 and V2 systems were similar (0.02~0.21 m/s), and was 0.04~0.15 m/s in V3 during winter. From summer to fall, air speed in V1, V2, and V3 systems were 0.10~0.41 m/s, 0.10~0.83 m/s, and 0.11~0.26 m/s, respectively. V2 system showed bigger fluctuation of air speed than other systems. During winter, the highest concentrations of ammonia in V1, V2, and V3 systems were 7.0, 3.5, and 8.7 ppm, respectively. Hydrogen sulfide was not detected. The highest concentrations of ammonia from summer to winter in V1, V2, and V3 systems were 6.1, 2.8, and 5.6 ppm, respectively. Swine growth showed no statistical significance among systems. However, daily weight gain was approximately 4% higher in V1 and V3 than in V2. Feed intake/daily weight gain was approximately 4% higher in V1 than other systems. From summer to fall, daily weight gain in V1 and V3 tended to approximately 3% higher than other systems, and feed intake/daily weight gain was approximately 2% higher in V1 than other systems. Hence, V2 system for the ventilation system of HRHB should not be utilized.