• Title/Summary/Keyword: 착용성

Search Result 943, Processing Time 0.023 seconds

Risk Factors for Hearing Loss in Very Low Birth Weight Infants: Results of Hearing Test in Infants <1,500 g (극소 저체중 출생아에서 청력 손상에 영향을 미치는 요인: 1,500 g미만의 청력 검사 결과)

  • Sung, Min-Jung;Han, Young-Mi;Park, Kyung-Hee;Lee, Il-Woo;Byun, Shin-Yun
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.328-336
    • /
    • 2011
  • Purpose: An association between very low birth weight infants(VLBWI) and hearing loss has long been recognized. Early identification and intervention for hearing loss benefits language and speech/cognitive development. We investigated the risk factors and clinical outcomes of hearing loss among VLBWI. Methods: We analyzed the results of auditory brainstem response (ABR) testing of VLBWI. These infants were admitted to the neonatal intensive care unit (NICU) of Pusan National University Yangsan Hospital between December 2008 and February 2011. A follow-up was conducted subsequently. Results: ABR evaluations were performed on 65 infants, and 31 showed abnormal results (47.7%). Among the 31 infants, 10 were classified with moderate/severe/profound hearing loss (15.4%). The infants with abnormal ABR had a higher incidence of low birth weight, prolonged ventilator care, cumulative dose of furosemide, and the lowest $PaO_2$ (P<0.05). Those with moderate/severe/profound hearing loss had a higher incidence of low Apgar scores at 5 minutes (odds ratio[OR],0.34; 95% confidence interval[CI],0.13-0.89), prolonged ventilator care (OR,1.06; 95% CI,1.01-1.12), and mild hearing loss compared to those without profound hearing loss. Follow-up evaluations on eight infants with ABR reveled improvements 5.6${\pm}$3.9 months later. One infant, who had profound hearing loss in both ears, used a hearing aid. Conclusion: Factors influencing hearing loss at the first VLBWI hearing screening test included lower Apgar scores at 5 min and prolonged use of a ventilator. Most VLBWI with hearing losses were expected to recover after several months of follow-up.

Evaluation of Radiation Exposure to Medical Staff except Nuclear Medicine Department (핵의학 검사 시행하는 환자에 의한 병원 종사자 피폭선량 평가)

  • Lim, Jung Jin;Kim, Ha Kyoon;Kim, Jong Pil;Jo, Sung Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.32-35
    • /
    • 2016
  • Purpose The goal for this study is to figure out that medical staff except Nuclear Medicine Department could be exposed to radiation from the patients who take Nuclear Medicine examination. Materials and Methods Total 250 patients (Bone scan 100, Myocardial SPECT 100, PET/CT 50) were involved from July to October in 2015, and we measured patient dose rate two times for every patients. First, we checked radiation dose rate right after injecting an isotope (radiopharmaceutical). Secondly, we measured radiation dose rate after each examination. Results In the case of Bone scan, dose rate were $0.0278{\pm}0.0036mSv/h$ after injection and $0.0060{\pm}0.0018mSv/h$ after examination (3 hrs 52 minutes after injection on average). For Myocardial SPECT, dose rate were $0.0245{\pm}0.0027mSv/h$ after injection and $0.0123{\pm}0.0041mSv/h$ after examination (2 hrs 09 minutes after injection on average). Lastly, for PET/CT, dose rate were $0.0439{\pm}0.0087mSv/h$ after examination (68 minutes after injection on average). Conclusion Compared to Nuclear Safety Commission Act, there was no significant harmful effect of the exposure from patients who have been administered radiopharmaceuticals. However, we should strive to keep ALARA(as low as reasonably achievable) principle for radiation protection.

  • PDF

Proposal of Modified Velpeau View as an Alternative Test Method of Velpeau View and the Visual Comparison (Velpeau view의 대체 검사법으로서 modified velpeau view의 제안 및 영상 비교평가)

  • Lee, Jae-Hyun;Kim, Sang-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.323-328
    • /
    • 2010
  • If a patient wearing arm sliding due to shoulder dislocation or fracture is impossible with abduction, the velpeau view is performed instead of superior-inferior axial projection view. However, it aggravates the patient's pain because it is difficult for the patient with dislocation or fracture to pull back the shoulders. Therefore, I suggest a new method of the 'modified velpeau view' that allows patients to lower their heads at examination. In order to investigate the easiness of fixing posture at examination and clinical utility, I conducted a study comparing the bone structures at the velpeau view and those at the modified velpeau view depending on wall-bucky and the patients' leaning forward angle ($30^{\circ},\;45^{\circ},\;60^{\circ}\;and\;75^{\circ}$), with the subjects of 20 velpeau view-prescribed patients amongst who had come to my hospital suspected of dislocation of shoulder or fracture and 30 healthy people from October of 2009 to January of 2010. Department of radiologists and orthopedics specialists evaluated the pictures for scales 0 to 5(best grade) under the given criteria. As a result of comparison in bone structures depending on wall-bucky and the leaning-forward angle in the group of healthy people, the velpeau view and the modified velpeau showed a similar diagnostic utility at $45^{\circ}$ and $60^{\circ}$. The picture evaluation result for proving diagnostic value showed that the anterior and posterior of shoulder heads and the anterior and posterior of glenoid fossa could be observed in the velpeau view; on the other hand, besides these areas acromioclavicular joint and coracoid process could be viewed in the modified velpeau view. This result verified that the modified velpeau view could replace the velpeau view for its diagnostic value as an examination method. This result, moreover, suggests that the modified velpeau view needs to be studied and improved from a variety of perspectives not only for an alternative for patients having troubles with the velpeau view position but also for clinical application of new test method for diagnosis of shoulder disorders other than dislocation of shoulder or fracture.

A Study on Radiation Exposure Dose of Patients and Operator during Percutaneous Vertebroplasty (경피적 추체 성형술 시행 시 환자와 시술자의 방사선 피폭선량에 관한 연구)

  • Lee, Jae-Heon;Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.139-144
    • /
    • 2017
  • Percutaneous vertebroplasty (PVP) is increasingly used to treat osteoporotic vertebral fractures, myeloma and osteolytic vertebral metastases. The purpose of this study was to measure the absorbed radiation exposure dose and time during PVP and to assess the possibility of deterministic radiation effects to the operator and patient. The radiation dose and time measure by three pain physicians performed consecutive procedures using the twenty case PVP. Patient's dosimeter placed at the anteroposterior(AP) side was treatment of the vertebra body located in the upper level 2-3 and lateral(LAT) side was flank proximal to C-arm tube of back. Operator's dosimeter placed at the apron outside of upper sternum (thyroid), left chest, lower extremity and apron inside of left chest. Results: Radiation exposure times were $3.6{\pm}0.71min$. Measurements on the Patient radiation dose were AP $121.4{\pm}48.1{\mu}Sv$, LAT side $614.7{\pm}177.1{\mu}Sv$. Operator radiation dose were outside of the lead apron upper sternum $33.7{\pm}7.3{\mu}Sv$, outside of the lead apron chest $49.2{\pm}15.0{\mu}Sv$, outside of the lead apron lower extremity $12.8{\pm}3.8{\mu}Sv$ and inside of the lead apron chest $4.2{\pm}1.4{\mu}Sv$. To escape from the danger of radiation first long distance from the c-arm tube second exposure time reduced second lead apron used fluoroscopy during PVP is more safety patient and operation from the radiation exposure.

New maxillary anterior ridge classification according to ideal implant restorative position determined by CAT (전산화단층영상을 이용한 이상적 임플란트 수복 위치에 따른 상악 전치부 치조제의 새로운 분류)

  • Park, Young-Sang;Cho, Sang-Choon;Kim, Kyoung-Nam;Kim, Kwang-Mahn;Choi, Seong-Ho;Moon, Hong-Seok;Lee, Yong-Keun
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.sup2
    • /
    • pp.385-396
    • /
    • 2007
  • This study proposed a new classification system for maxillary anterior alveolar ridge deformities based on CAT-scan implant simulation as a useful concept in order to more precisely predict treatment outcomes and the necessity for ridge augmentation prior to implant placement. The results indicate that a high number of cases in the maxillary anterior area would require augmentation procedures in order to achieve ideal implant placement and restoration.

The Effects of Wearing Protective Devices among Residents and Volunteers Participating in the Cleanup of the Hebei Spirit Oil Spill (허베이스피릿호 유류유출사고 방제작업 참여자의 보호장비착용 효과)

  • Lee, Seung-Min;Ha, Mi-Na;Kim, Eun-Jung;Jeong, Woo-Chul;Hur, Jong-Il;Park, Seok-Gun;Kwon, Ho-Jang;Hong, Yun-Chul;Ha, Eun-Hee;Lee, Jong-Seung;Chung, Bong-Chul;Lee, Jeong-Ae;Im, Ho-Sub;Choi, Ye-Yong;Cho, Yong-Min;Cheong, Hae-Kwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Objectives : To assess the protective effects of wearing protective devices among the residents and volunteers who participated in the cleanup of the Hebei Spirit oil spill. Methods : A total of 288 residents and 724 volunteers were surveyed about symptoms, whether they were wearing protective devices and potential confounding variables. The questionnaires were administered from the second to the sixth week following the accident. Spot urine samples were collected and analyzed for metabolites of 4 volatile organic compounds(VOCs), 2 polycyclic aromatic hydrocarbons(PAHs), and 6 heavy metals. The association between the wearing of protective devices and various symptoms was assessed using a multiple logistic regression adjusted for confounding variables. A multiple generalized linear regression model adjusted for the covariates was used to test for a difference in least-square mean concentration of urinary biomarkers between residents who wore protective devices and those who did not. Results : Thirty nine to 98% of the residents and 62-98% of volunteers wore protective devices. Levels of fatigue and fever were higher among residents not wearing masks than among those who did wear masks(odds ratio 4.5; 95% confidence interval 1.23-19.86). Urinary mercury levels were found to be significantly higher among residents not wearing work clothes or boots(p<0.05). Conclusions : Because the survey was not performed during the initial high-exposure period, no significant difference was found in metabolite levels between people who wore protective devices and those who did not, except for mercury, whose biological half-life is more than 6 weeks.

Investigation of aerodynamic evaluation in female patients undergoing thyroidectomy (갑상선절제술을 받은 여성 환자의 공기역학 검사변수 조사)

  • Kang, Young Ae;Kwon, In Sun;Won, Ho-Ryun;Chang, Jae Won;Koo, Bon Seok
    • Phonetics and Speech Sciences
    • /
    • v.12 no.2
    • /
    • pp.73-80
    • /
    • 2020
  • Breathing is the voice's driving force and also acts as a regulator of larynx function and efficiency. Respiratory distress is a side effect of general anesthesia in thyroid surgery. Therefore, this study's objective was to provide practical and complementary information for voice recovery after thyroid surgery, based on aerodynamic evaluation pre- and post-thyroidectomy. From May 2014 to July 2015, aerodynamic evaluations were performed on 34 female patients diagnosed with thyroid papillary cancer one week before surgery (PRE), one month after surgery (P1), and three months after surgery (P3). The Phonatory Aerodynamic System (model 6600, KayPENTAX, USA) was employed for this purpose, and a total of 29 analysis parameters were selected. The results showed statistically significant differences in peak expiratory airflow (p=0.004), mean pitch (p<0.01), expiration airflow duration (p=0.001), and expiratory volume (p=0.018), based on time factors. In the comparison of time factors, peak expiratory airflow and mean pitch parameters were different in PRE-P1 and PRE-P3. Expiration airflow duration and expiratory volume parameters were different in PRE-P3 and P1-P3. The interaction effect of time and surgical range was significant only for expiratory volume (p=0.024). Female patients who undergo thyroidectomy require post-operative breathing training, and exhalation improvement is considered to reflect a positive lifestyle after surgery.

The Physiological Efficacy of Aloe Gel (Aloe Gel의 생리 효과에 대한 고찰 - Gel의 다당류와 미량 성분을 중심으로 -)

  • 서화중
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.6
    • /
    • pp.1026-1038
    • /
    • 1995
  • Although aloe lost a lot of its previous popularity in modern clinical uses as medicine numerous scientific researches still have claimed the beneficial properties(curing and general tonic effect) of aloe gel. Whereas considerable contradictory reports have helped to confuse the aloe gel issue and continually aroused controversy about aloe gel efficacy. However health food, cosmetic and medicinal products made from aloe gel are widely available in the world market especially in U.S.A. so the growing of Aloe plant and the processing of A. vera gel have become big industries in some countries. In some previous papers the salicylic acid, one of the common trace gel components, was thought to have an analgetic and antinflammatory effect. Large amount of Mg ion in the gel was suggested to act as anesthetic, Mg-lactate as antihistamic, and Aloctin A(a glycoprotein) as wound healer by promoting the cell growth. The carboxypeptidase and bradykinase activity in the gel were proposed to have the pain relieving and antiinflammatory effect. But any of thes etheories concerining the physiological action of the trace gel components has not been demonstrated by modern pharmacology, and failed to be supported by clinical research. It was suggested by some research workers that trace amount of anthraquinone compounds in the gel play an important role to act as false substrate inhibitors for PG and TX production(antiprostanoid effect), by which, they believed, inflammation, burn and frostbite, and infected wound could be healed. This hypothesis has not been substantiated. Butthe suggested antimicrobial action, antidiabetic, and antidotic effect of aloe gel are likely to be attributed to the trace anthraquinone compounds. In a lot of recent experimental reports it has been claimed that aloe gel polysaccharides(acetylglucomannan, acetylmannan, and glycoprotein) have the antimicrobial, antinflammatory, antitumour, and infected wound healing effect by immunoenhancement. It is hoped that these effects will be soon documented in clinical studies, then the controversy on aloe gel beneficial effect will cease. In the 30 days subchronic toxicity test the lowest observed adverse effect level of acemannan(acetylmannan) on dog was 5.0 mg/kg, IP. But the aloe gel is generally agreed to be harmless and non toxic even for the internal use such as health food. In the case of idiosynrasy one must keep the delayed type hypersensitivity reaction of aloe gel in mind. In conclusion it seem to be impossible to simply refuse a lot of evidences made by research workers who have claimed aloe gel's beneficial effects and to deny the fact that there had been long therapeutic histories of Aloe plants.

  • PDF

Improvement of the Elbow Function with Early Mobilization and Rigid Fixation of Coronoid Fracture by Tension Band Technique (압박 긴장대 방법을 이용한 구상 돌기 골절의 견고한 고정과 조기 운동을 통한 주관절 기능의 향상)

  • Rhyou, In-Hyeok;Suh, Bo-Gun;Kim, Hyung-Jin;Chung, Chae-Ik;Kim, Kyung-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.159-166
    • /
    • 2009
  • Purpose: We wanted to evaluate the surgical results of early mobilization after rigid fixation of small coronoid fracture using the tension band technique Materials and Methods: Eight cases of coronoid fracture were fixed with the tension band technique and using K-wire and wire through the medial approach. All the cases were Regan-Morrey type 2. According to O'Driscoll, they were classified as 5 cases of the tip type (subtype 2) and 3 cases of the anteromedial type (1 case of subtype 2, and 2 case of subtype 3). The associated collateral ligament injuries (6 cases) and radial head/neck fractures (4 cases) were managed simultaneously. After immobilization for 5~7 days, active ROM exercise with a fitted hinge brace started and continued till postoperative 6 weeks. The patients were assessed for pain, ROM and functional disability using the Mayo elbow performance score (MEPS) at an average of 11 months (range: 6~28 months). The ulnar nerve symptoms were also investigated. Results: We observed solid union in all the coronoid fractures without hardware failure. An average of 2.2 wires (range: 2~4) were used. The mean extension was $3^{\circ}$(range: $0^{\circ}\sim25^{\circ}$), the mean flexion was $137^{\circ}$(range: $130^{\circ}\sim140^{\circ}$), the mean pronation was $69^{\circ}$(range: $45^{\circ}\sim90^{\circ}$) and the mean supination was $78^{\circ}$(range: $45^{\circ}\sim90^{\circ}$). The mean MEPS was 96 (range: 65~100). Ulnar nerve symptoms occurred at postoperative one day and persisted in one patient with the terrible triad of taking radial head excision and residual medial instability. Conclusion: The tension band technique uses easily obtained, economic K-wires and the wire was strong enough to permit early elbow ROM exercise and the technique might improve the elbow function. It was especially useful for fixation of multiple small fragments.

A Proposal to Control System and the Problems of the Problems of the Report about Supply and Demand for Medical Technicians and Management Policy ("의료기사인력수급에 관한 보고서"의 문제점과 관리제도의 개선방안)

  • Kim, Sang-Hyun;Lim, Yongmoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.25-30
    • /
    • 2008
  • Purpose: In this paper, we have analyzed the problems of the Oh's report which is used to the basic data for supply and demand of medical technicians and studied a proposal for improvement to control system and supply and demand of korean optometrists. Methods: We have analyzed errors of Oh's report including supply and demand for medical technicians and management policy, expecting number for future optician, inaccurate estimation by limited data (employment rate, retirement rate, mortality rate) and an incorrect method of measurement for future supply and demand. Results: Oh's report showed the 18% error for estimation of supply which exclude the irregular entrance students. The estimation of supply was calculated by graduation rate 62.6% (college and University of Technology are 78.9% and 85.98% respectively), employment rate 65.8% (the average employment between 2002 and 2007 is 73.96%) and retirement rate is 2.3% (the retirement of pharmacists is 1.3%) but it showed the significant differences to objective data. For estimate the suitable ratio of optometrists to the population, the ratio use of medical facilities by an age group was used, and suggested spectacle wearers 1,280 persons (populations 2,928 persons) per optometrist but the different from reference of Germany (4,706 persons), America (1,789 persons) and Korea (1,825 persons/an optometrist) are applied to estimation on supply. This report applied the low employment rate and argued that maintain the present situation, but claimed that utilize unemployment persons. The above result has induced double weighting effect on estimation of supply. Conclusions: To solve the related problems of supply and demand, we have to make a search for exact data and optimum application model, have to take an example of nation similar job category as Germany and the research result of the job satisfaction into consideration. After we get the integrated research result, we must carried out the policy with fairness and balance for the estimation of supply and demand. Therefore exact research is required prior to beginning policy establishment, government and related group have to make a clear long-term plan and permanent organization for medical technician to establish supply and demand of medical technician.

  • PDF