• Title/Summary/Keyword: 차단계수

Search Result 163, Processing Time 0.027 seconds

Tension calculation on trash curtain in current (흐름중 부유쓰레기 차단막에 작용하는 장력계산)

  • Cho I.H;Choi H.S.;Yu J.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.3
    • /
    • pp.65-73
    • /
    • 2001
  • Herein, a theoretical method based on the catenary model Is applied to obtain the tension and drag forces acting on the trash curtain which is deployed at river for the prevention of floating debris inflow into the ocean. Under the assumption that fluid drag is perpendicular to the trash curtain, the tension and drag forces are uniform along the trash curtain. As a numerical model, the trash curtain is moored both symmetrically and asymmetrically with respect to the flow. The tension and drag forces on the trash curtain are investigated according to the change of Bap ratio and inclined angle of the trash curtain. Numerical results show that tension parameter is increased as the gap ratio is increased. It is found that tension parameter is reduced as the inclined angle is increased in the case of asymmetric deployment. The numerical model is applied to the specific problem for the trash curtain (200m) deployed at the Tancheon on the Han river. The maximum inflow velocity that anchor system can endure is 2m/sec.

  • PDF

Studies on the evaluation of efficacy of functional cosmetics(I) -Studies on the in vitro SPF test method of sunscreen products (기능성화장품의 기능성평가에 관한 연구(I) -자위선차단화장품의 in vitro 시험법 연구)

  • 손경훈;김영옥;이정표;양성준;백옥진;김원희;김종갑;허문영;최상숙
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.28 no.3
    • /
    • pp.171-184
    • /
    • 2002
  • The present study was undertaken to develop the in vitro sunprotection factor(SPF) measurement method having good correlation with in vivo method. As in vitro method, 8% homomentyl salicylate, P3 reference standard and sunscreens on market were measured using SPF 290 analyzer and were compared the SPF with labed value. In vitro SPF of 8% HMS and P3 reference standard were 4.59 $\pm$ 0.12 and 14.94 $\pm$ 0.83. There are good correlation, correlation factor were 0.9506 and 0.9769 respectively, between the in vitro and in vivo SPF for the sunscreen creams and lotions examined. Correlation factors of makeup base & liquid goundation, lotion labled with “shake before use”, compact powder were 0.8812, 0.8632 and 0.5984. The best sample applied method of compact powder was 1:0.8 mixture with cream base. These results suggest that the in vitro test method could be used as an alternative method for SPF.

Computation Reduction in Designing an FIR LPF with Very Low Cutoff Frequency (아주 낮은 차단주파수를 가지는 FIR LPF의 계산량 감소기법)

  • 최영하
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06e
    • /
    • pp.7-10
    • /
    • 1998
  • 일반적으로 매우 낮은 차단주파수를 가지는 FIR 저역통과 필터의 경우 그 과도영역의 폭이 상대적으로 매우 좁기 때문에 긴 임펄스 응답을 가지게 되며, 따라서 많은 계산량을 필요로 하게 된다. 본 논문에서는, FIR 필터의 계수를 서브샘플링(subsampling)하여 계산량의 현저한 감소를 도모하고, 그로 인하여 발생하는 주파수 영역의 이미지를 IIR 필터를 사용하여 제거하는 기법을 제안한다. IIR 필터로 인하여 발생하는 위상의 왜곡은 앞단의 FIR 필터의 계수를 조절함으로써 상쇄시킬 수 있다. 제안된 알고리듬을 채택할 경우, 동일한 성능의 일반 FIR 필터에 비하여 사용하는 메모리의 양은 거의 같으나, 계산량은 수십분의 일까지 감소시킬 수 있다.

  • PDF

Wave Screening Performance Using Floating and Submerged Breakwaters (부유식방파제와 잠제를 이용한 파랑 차단 성능 연구)

  • Won Chul Cho;Jin Won Lee
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.15 no.4
    • /
    • pp.224-231
    • /
    • 2003
  • In this study, the hybrid breakwater system - a breakwater system combining the floating breakwater with the submerged breakwater - is used to improve the wave screening performance that may not be achieved by using the floating breakwater or the submerged breakwater, separately. Two-dimensional finite element method is used for numerical analysis and the wave reflection ratio and the wave transmission ratio are analyzed for the proposed case. In case of using the hybrid breakwater system, wave screening performance is more effective than in case of using the floating breakwater or the submerged breakwater, separately. It also shows an effective wave screening on the long wave period and an advanced wave screening performance with low height of the submerged breakwater.

Numerical Analysis on Effect of Semi-permeable Subsurface Barrier to Mitigate Seawater Intrusion (해수침입 저감을 위한 반투수성 지하 차단벽 효과의 수치적 분석)

  • Woo Chang Jeong;Hee Jae Yoon;Jae Hyun Bae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.509-509
    • /
    • 2023
  • 해수침입은 해안지역에서 각종 용수공급 특히 생활용수의 원활하고 지속적인 공급을 저해하는 가장 근본적인 원인이라 할 수 있다. 이러한 해수 침입의 정도를 저감하기 위해 수리학적 및 물리학적 다양한 방법들이 사용되고 있으며, 그중에서 불투성의 지하 차단벽이 가장 효과적으로 해수침입을 저감시키는 방법으로 알려져 있으며, 전 세계적으로 가장 빈번하게 사용되고 있다. 그러나 불투수성 지하 차단벽의 경우 해수위 변동에 따른 해수와 담수의 원활한 흐름에 지장을 초래하게 되며, 차단벽 좌우 양측 하단부에 장시간에 걸쳐 오염물질 퇴적 및 염분의 축적이 발생될 수 있다. 본 연구에서는 가정된 해안대수층 양끝단에 설치된 담수 저류조와 염수 저류조 사이의 수심차 변화에 따른 염수침입의 거동에 대해 모의 및 분석을 수행한 후 불투수성 지하 차단벽의 높이를 변화시키면서 염수침입의 차단 정도를 분석하였다. 또한 불투수성 지하 차단벽에 대한 모의분석결과를 이용하여 반투수성 지하 차단벽의 유효폭 및 투수계수 변화에 따른 염수침입의 거동을 비교 분석하였다.

  • PDF

Control of Wave Screening Performance of Floating Breakwaters (부유식 방파에의 파랑 차단 성능 제어)

  • 양우석;조원철;박우선
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.3
    • /
    • pp.230-236
    • /
    • 2001
  • The numerical investigations on the wave-screening characteristics of floating breakwaters are presented. The fluid motion is idealized as linearized, two dimensional potential flow. A finite element model is adopted to analyze the performance of floating breakwaters. Numerical experiments are carried out for two type floating breakwater. One is a conventional pontoon type breakwater with rectangular cross-section, and the other is a side float breakwater which consists of two rectangular shaped floats connected to each other by a frame. To improve the performance of the floating breakwaters, especially for long-period wave conditions, numerical experiments are carried out for the cases attaching the thin plates at the bottom of folats in the vertical direction.

  • PDF

A Study on the Interaction with Preservatives and UV-Filters, Packaging Materials for Sunscreen Preservation (자외선차단제품의 방부력 확보를 위한 방부제와 자외선 차단제, 제품 포장재의 상관성 연구)

  • Park, Tae-Hun;Kwack, Il-Young;Jeon, Gi-Boong;Kim, Hyun-Hee;Kim, Han-Kon;Shin, Kye-Ho
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.36 no.4
    • /
    • pp.259-263
    • /
    • 2010
  • We measured and compared the partition coefficients and absorption levels of preservative phenoxyethanol (PE), antimicrobial ethylhexylglycerin (EG) and UV-filters widely used in cosmetic products and more specifically evaluated the relative absorption level of PE depending on various packaging materials. The resulting partition coefficients of 11 UV filters in relation to PE and EG displayed EG with a relatively higher partition coefficients. The partition coefficients of Tinsorb M and Solaveil CT434 were also high. Among the UV-filter ingredients with EG absorption levels exceeding 40 % were Gransil PSQ, UV Titan M 160 and Micro $TiO_2$ MT 100 TV, whereas Gransil PSQ and Scadder showed PE absorption levels above 40 %. In addition, we confirmed that PE had displayed an absorption level of 7 ~ 8 % as a result of 1 month-long exposure to packaging material polyoxymethylene. This extensive research illustrates the possibility of producing the most potent preservative contents based on studying the relative compatibility between UV-filters and preservatives and selecting the adequate preservatives to be used. Furthermore, preservative level can also decline with passage of time depending on the type of packaging material used.

Overall Heat Transfer Coefficient Measurement of Covering Materials with Thermal Screens for Greenhouse using the Hot Box Method (핫박스를 이용한 온실 피복재 및 보온재의 조합에 따른 관류열전달계수 측정)

  • Diop, Souleymane;Lee, Jong-Won;Na, Wook-Ho;Lee, Hyun-Woo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.5
    • /
    • pp.1-7
    • /
    • 2012
  • 본 연구의 목적은 국내에서 상용되고 있는 온실 피복재 및 보온재의 조합에 따른 관류열전달계수를 핫박스를 이용하여 평가하는 것이다. 온실용 일중 및 이중 피복재와 이중 보온재의 조합에 대하여 야간천공복사 차단여부에 따른 관류열전달계수를 핫박스를 이용하여 실외에서 측정하였다. 처리조건은 일중피복, 이중피복, 이중피복과 이중 마트보온재 및 이중피복과 이중 다겹보온재의 조합조건과 천공복사 유무에 따른 조건이며 총 8가지이다. 제작된 핫박스는 상시 변화하는 외부의 기상조건하에서도 내부온도를 설정된 온도로 일정하게 잘 유지할 수 있었다. 온실 피복재 및 보온재의 관류열전달계수를 측정하는 실내용 측정장치는 반드시 야간천공복사를 모의할 수 있는 측정장치가 되어야 할 것이다. 야간복사를 차단함으로서 온실의 열 손실을 줄여 보온효과를 얻을 수 있을 것으로 분석되었다. 모든 피복방식에 대해 야간복사 차단장치 유무에 관계없이 높은 풍속에서의 관류열전달계수가 낮은 풍속에서보다 더 큰 것으로 나타났다. 본 연구에서 사용된 측정기법을 사용하면 국내에서 생산되는 피복재 및 보온재의 관류열전달 특성을 정량적으로 비교할 수 있을 것으로 기대된다.

Contamination of Chinese Cabbage with $^{85}Sr$, $^{103}Ru$ and $^{134}Cs$ Related to Time of Foliar Application ($^{85}Sr$, $^{103}Ru$, $^{134}Cs$의 엽면처리 시기에 따른 배추의 방사능 오염)

  • Choi, Yong-Ho;Lim, Kwang-Muk;Park, Hyo-Guk;Lee, Won-Yun;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.219-227
    • /
    • 1998
  • A solution containing $^{85}Sr$, $^{103}Ru$ and $^{134}Cs$ was applied to Chinese cabbage in a greenhouse via foliar spraying at 5 different times during its growth. Interception of the applied activity by plant showed no difference among radionuclides and increased with decreasing time interval between application and harvest. The maximum interception factor observed was 0.87. Percentages of the intercepted activity remaining in the whole leaves at harvest varied $16{\sim}58%$ for $^{85}Sr$, $15{\sim}73%$ for $^{103}Ru$ and $33{\sim}64%$ for $^{134}Cs$, with application time and those for the inner leaves (without 6 outmost leaves) varied $2{\sim}35%$, $0.4{\sim}46%$ and $14{\sim}40%$, respectively. It was demonstrated that rain plays an important role in weathering loss of the activity. Tying the upper end of the plant prior to the last application lowered interception and remaining activity in the inner leaves by factors of $3{\sim}4$. Present results can be referred to in predicting the radionuclide concentration in Chinese cabbage and deciding counter-measures at the time of an accidental release from the nuclear installation.

  • PDF