Overall Heat Transfer Coefficient Measurement of Covering Materials with Thermal Screens for Greenhouse using the Hot Box Method  

Diop, Souleymane (Department of Agricultural Engineering, Kyungpook National University)
Lee, Jong-Won (Department of Agricultural Engineering, Kyungpook National University)
Na, Wook-Ho (Department of Agricultural Engineering, Kyungpook National University)
Lee, Hyun-Woo (Department of Agricultural Engineering, Kyungpook National University)
Publication Information
Journal of The Korean Society of Agricultural Engineers / v.54, no.5, 2012 , pp. 1-7 More about this Journal
Keywords
matt screens; multi layers screens; outside experiment; polyethylene film; shelter from sky radiation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Plaisier, H., 1996. The use of thermal screens in greenhouses in mild climates. Plasticulture 96(3): 43-48.
2 Seginer, I., D. Kantz, U. M. Peiper, and N. Levav, 1988. Transfer coefficients of several polyethylene greenhouse covers. J. Agric. Engng Res. 39: 19-37.   DOI
3 Zabeltitz, C., 1992. Energy-efficient greenhouse designs for Mediterranean countries. Plasticulture 94(4): 43-48.
4 Pirard, G., J. Deltour, and J. Nijskens, 1994. Controlled operation of thermal screens in greenhouses. Plasticulture 94(3): 11-22.
5 Asdrubali, F., and G. Baldinelli, 2011. Thermal transmittance measurements with the hot box method: Calibration, experimental procedures, and uncertainty analyses of three different approaches. Energy and buildings 43: 1618-1626.   DOI
6 ASTM, 1993. Standard test method for steady-state thermal performance of building assemblies by means of a guarded hot box. ASTM standards C 236-89: 52-62.
7 Feuilloley, P., and G. Issanchou, 1996. Greenhouse covering materials measurement and modelling of thermal properties using the hot box method, and condensation effects. J. Agri. Engng Res. 65: 129-142.   DOI
8 Geoola, F., Y. Kashti, A. Levi, and R. Brickman, 2009. A study of the overall heat transfer coefficient of greenhouse cladding materials with thermal screen using the hot box method. Polymer Testing 28: 470-474.   DOI
9 Giacomelli, G. A., and W.J. Roberts, 1993. Greenhouse covering systems. HortTechnology 3(1): 50-58.
10 Kittas, C., 1994. Determination du coefficient global de transmission de chaleur a travers la paroi d'une serre. [Overall heat transfer coefficient of the greenhouse cover]. Agricultural and Meteorolgy 69: 205-221.   DOI
11 Nijskens, J., J. Deltour, S. Coutisse, and A. Nisen, 1984. Heat transfer through covering materials of greenhouses. Agricultural and Forest Meteorology 33: 193-214.   DOI
12 Ozturk. H. H., 2005. Experimental determination of the overall heat loss coefficient for energy requirement of greenhouse heating. Int. J. Energy Res. 29: 937-944.   DOI
13 Papadakis, G., D. Briassoulis, G. S. Mugnozza, G. Vox, P. Feuilloley, and J. A. Stoffers, 2000. Radiometric and thermal properties of, and testing methods for, greenhouse covering materials. J. Agric. Engng. Res. 77(1): 7-38.   DOI
14 Abdel-Ghany, A. M., 2011. Solar energy conversions in the greenhouses. Sustainable Cities and Society 1: 219-226.   DOI