• Title/Summary/Keyword: 집적 영상 시스템

Search Result 76, Processing Time 0.023 seconds

Optical implementation of 3D image correlator using integral imaging technique (집적영상 기술을 이용한 3D 영상 상관기의 광학적 구현)

  • Piao, Yongri;Kim, Seok-Tae;Kim, Eun-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.8
    • /
    • pp.1659-1665
    • /
    • 2009
  • In this paper, we propose an implementation method of 3D image correlator using integral imaging technique. In the proposed method, elemental images of the reference and signal 3D objects are recorded by lenslet arrays and then reference and signal output plane images with high resolution are optically reconstructed on the output plane by displaying these elemental images into a display panel. Through cross-correlations between the reconstructed reference and the single plane images, 3D object recognition is performed. The proposed method can provide a precise 3D object recognition by using the high-resolution output plane images compared with the previous methods and implement all-optical structure for real-time 3D object recognition system. To show the feasibility of the proposed method, optical experiments are carried out and the results are presented.

Generation of High Resolution Elemental Images using Expanded Depth Image (깊이영상 확장을 이용한 고해상도 요소영상 생성)

  • Song, Min-Ho;Lim, Byung-Muk;Jeong, Ji-Seong;Yoo, Kwan-Hee
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2016.05a
    • /
    • pp.343-344
    • /
    • 2016
  • 최근 3D 기술의 이슈는 안경을 사용하지 않고 고화질 3D를 볼 수 있도록 하는 것이며, 그 기술로 집적영상시스템이 대표적으로 사용된다. 본 논문에서는 고화질의 3D 영상 생성에 대한 기법의 하나로 저해상도의 깊이영상을 고해상도로 확장시켜 고해상도 요소영상을 생성하는 기법을 제안한다. 제안 기법을 적용한 결과 질 좋은 요소 영상을 생성하였다.

  • PDF

Studies on the millimeter-wave Passive Imaging System II (밀리미터파 수동 이미징 시스템 연구 II)

  • Jung, Min-Kyoo;Chae, Yeon-Sik;Kim, Soon-Koo;Yoo, Jin-Seob;Koji, Mizuno;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.3 s.357
    • /
    • pp.105-110
    • /
    • 2007
  • We have built the millimeter-wave passive imaging system with a lens and mechanical scan antenna. The lens was designed based on optical theory in order to focus millimeter-wane. A full image was taken from image points scanned by Placing antenna at the representative focal plane selectively. An integrated antenna array device for low-loss and low-noise with the array of 4 by 1, where components such as antenna, balun, MMIC, and detector were assembled on a sin91e substrate, and a fermi tapered slot antenna with high-gain and low-side lobe were used for elements of this millimeter-wave passive imaging system. Two dimensional antenna arrangement on focal plane was achieved in this imaging system.

A Reconfigurable Analog Front-end Integrated Circuit for Medical Ultrasound Imaging Systems (초음파 의료 영상 시스템을 위한 재구성 가능한 아날로그 집적회로)

  • Cha, Hyouk-Kyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.66-71
    • /
    • 2014
  • This paper presents an analog front-end integrated circuit (IC) for medical ultrasound imaging systems using standard $0.18-{\mu}m$ CMOS process. The proposed front-end circuit includes the transmit part which consists of 15-V high-voltage pulser operating at 2.6 MHz, and the receive part which consists of switch and a low-power low-noise preamplifier. Depending on the operation mode, the output driver in the transmit pulser can be reconfigured as the switch in the receive path and thus the area of the overall front-end IC is reduced by over 70% in comparison to previous work. The designed single-channel front-end prototype consumes less than $0.045mm^2$ of core area and can be utilized as a key building block in highly-integrated multi-array ultrasound medical imaging systems.

SoC Platform기반 Design Methodology

  • Jang, Jun-Yeong;Han, Jin-Ho;Bae, Yeong-Hwan;Jo, Han-Jin
    • IT SoC Magazine
    • /
    • s.2
    • /
    • pp.34-38
    • /
    • 2004
  • 실리콘 처리 기술의 고속화 요구와 유무선 환경에서 동영상 통신이 가능한 비디오 폰, 영상 회의 시스템, 이동 통신용 단말기 등의 전자 제품 사용자의 급증은 시스템을 하나의 칩에 집적화하는 SoC(System-On-a-Chip) 설계 기술을 요구하고 있다. 칩의 복잡도와 SoC 제품의 생산성 차이가 계속적으로 증가함에 따라 현재의 IC 설계 방법으로는 SoC 제품의 성능과 요구의 변화를 만족시킬 수 없다. 칩의 면적을 최소화하고 성능을 최대화하며 게이트 수준의 최적화를 통한 기존의 셀 기반 설계 방법으로는 설계의 생산성 문제를 해결할 수 없다. 이러한 문제를 해결 위한 새로운 설계 방법인 IP 재사용을 기반으로 한 플랫폼 기반 설계가 제시되었다. 플랫폼 기반 설계는 SoC 제품을 빠르게 개발하기 위한 응용 기반 통합 플랫폼과 재사용이 가능한 IP(Intellectual Property) 이용한 플랫폼 기반 설계(Platform-Based Design) 방법이다. 새로운 설계 방법은 90% 이상의 IP 재사용을 통해서 설계 시간을 단축하며, 시스템 수준에서의 최적화를 통해서 제품의 시장 경쟁력(Time-to-Market)의 문제를 해결하기 위한 방법이다.

  • PDF

Measurement of Wax Appearance Temperature Using Image Processing (영상 처리기법을 이용한 오일의 왁스생성온도 측정)

  • Hwang, Soon-Hye;Kang, Pan-Sang;Lim, Jong-Se
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • When the oil is produced in the low temperature environment, wax can be accumulated in petroleum production system(pipeline, riser) and causes problems such as pipeline stucking, disturbance of the oil production. These problems can be lead to time-consuming and economic losses for flow assurance. For prediction and mitigation of wax deposition, it is necessary to measure the Wax Appearance Temperature(WAT) which is a temperature when the wax crystals start to be formed. WAT standard measurement method of transparent oil has to determine the cloud point of sample to the naked eye and cannot be applied to continuous change of the temperature. In this study, wax behavior of transparent oil samples are recorded depending on temperature using Visualized WAT Measurement System. Also, WATs of transparent oil samples are measured by image processing and compared with the result of the standard method.

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

A study on memory structure of real time video magnifyng chip (실시간 영상확대 칩의 메모리 구조에 관한 연구)

  • 여경현;박인규
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.1109-1112
    • /
    • 1999
  • 본 논문에서는 영상확대 chip의 video 입력부에 부분화면을 저장할 frame memory의 구조를 개선하고자 하였다. 영상확대 video scaler인 gm833×2는 입력단 측에 frame buffer memory가 필요하게 되지만, 이를 외부에 장착하려면 일반적으로 대용량의 FIFO 메모리를 사용하게 된다. 이것은 dualport SRAM으로 구성이 되며, 메모리 제어를 고가의 FIFO칩에 의존하는 결과를 가져온다. 또한 기존의 scaler chip은 단순히 확대처리만을 하며, 입력 전, 후에 data의 변경 또는 이미지처리가 불가능한 구조가 된다. 본 논문에서는 외부에 필요한 메모리를 내장한 새로운 기능의 chip을 설계하는 데에 있어 필수적인 메모리제어 로직을 제안하고자 한다. 여기서는 더 나은 기능의 향상된 메모리 제어회로를 제시하고 이를 One-chip에 집적할 수 있도록 하였다 이를 사용한 Video Scaler Processor chip은 SDRAM을 별도의 제어회로 없이 외부에 장착할 수 있도록 하여 scaler의 기능을 향상시키면서 전체 시스템의 구조를 간단히 할 수 있을 것으로 기대된다. 본 논문에서는 먼저 메모리 제어회로를 포함한 Video Scaler Processor chip의 메모리제어 하드웨어의 구조를 제시하고, 메모리 access model과 제어로직을 소개하고자 한다.

  • PDF

Computer-generated integral imaging system used in virtual reality (가상현실에 이용할 수 있는 컴퓨터 생성 집적 영상 시스템)

  • Seok, Myeong-Hun;Min, Seong-Uk
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.07a
    • /
    • pp.158-159
    • /
    • 2005
  • Three-dimensional(3D) integral imaging system which can be used in a virtual reality system is proposed. The proposed system uses a new image mapping algorithm which can achieve the real time processing, which is indispensable for the virtual reality system. 3D images generated by the advanced graphic software such as OpenGL API can be directly used without complex adaptation. Therefore, the computer-generated integral imaging system using the proposed mapping algorithm can be successfully applied to virtual reality.

  • PDF

Study about aperture ratio of projection-type integral imaging system (투사형 집적 영상 시스템의 개구율에 관한 연구)

  • Min, Seong-Uk
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.02a
    • /
    • pp.81-82
    • /
    • 2008
  • The projection-type integral imaging system using mirror array is studied at the viewpoint of the aperture ratio of system. The aperture ratio which is determined by the relation of the specifications of the projection lens and the elemental mirrors affects the viewing quality of integral imaging system. This factors play an important role in the system design.

  • PDF