Browse > Article
http://dx.doi.org/10.6109/JKIICE.2009.13.8.1659

Optical implementation of 3D image correlator using integral imaging technique  

Piao, Yongri (광운대학교 전자공학과 3DRC)
Kim, Seok-Tae (부경대학교 정보통신공학과)
Kim, Eun-Soo (광운대학교 전자공학과 3DRC)
Abstract
In this paper, we propose an implementation method of 3D image correlator using integral imaging technique. In the proposed method, elemental images of the reference and signal 3D objects are recorded by lenslet arrays and then reference and signal output plane images with high resolution are optically reconstructed on the output plane by displaying these elemental images into a display panel. Through cross-correlations between the reconstructed reference and the single plane images, 3D object recognition is performed. The proposed method can provide a precise 3D object recognition by using the high-resolution output plane images compared with the previous methods and implement all-optical structure for real-time 3D object recognition system. To show the feasibility of the proposed method, optical experiments are carried out and the results are presented.
Keywords
Integral imaging; Plane images; object recognition; 3D image correlator;
Citations & Related Records
연도 인용수 순위
  • Reference
1 G. Lippmann, "La photographic integrale," C.R. Acad. Sci. vol. 146, pp. 446-451, 1908
2 F. Okano, H. Hoshino, J. Arai, and I. Yuyama, 'Three-dimensional video system based on integral photography,' Opt. Eng. vol. 38, pp. 1072-1077, 1999   DOI
3 Y. Frauel and B. Javidi, "Digital three-dimensional image correlation by use of computer-reconstructed integral imaging," Appl. Opt. vol. 41, 2002, pp. 5488-5496   DOI   PUBMED
4 B. Lee, S. Y. Jung, S.-W. Min, and J.-H. Park, 'Three-dimensional display by use of integral photography with dynamically variable image planes,' Opt. Lett. vol. 26, pp. 1481-1482, 2001   DOI   ScienceOn
5 J. -H. Park, J. Kim, and B. Lee, "Three-dimensional optical correlator using a sub-image array," Opt. Express vol. 13, pp. 5116-5126, 2005   DOI   PUBMED
6 J.-S. Jang and B. Javidi, "Improved viewing resolution of three-dimensional integral imaging by use of nonstationary micro-optics," Opt. Lett. vol. 27, pp. 324-326, 2002   DOI   ScienceOn
7 S.-H. Hong, J.-S. Jang, and B. Javidi, "Three- dimensional volumetric object reconstruction using computational integral imaging," Opt. Express, vol. 12, pp. 483-491, 2004   DOI   PUBMED
8 S.-H. Hong and B. Javidi, 'Improved resolution 3D object reconstruction using computational integral imaging with time multiplexing,' Opt. Express vol. 12, pp. 4579-4588, 2004   DOI   PUBMED
9 N. Davies, M. McCormick, and L. Yang, "Three- dimensional imaging systems: a new development," Appl. Opt. vol. 27, pp. 4520-4528, 1988   DOI
10 D.-H. Shin, B. Lee and E.-S. Kim, "Improved viewing quality of 3-D images in computational integral imaging reconstruction based on lenslet array model," ETRI Journal, vol. 28, pp. 521-524, 2006   DOI   ScienceOn
11 O. Matoba, E. Tajahuerce, and B. Javidi, 'Real-time three-dimensional object recognition with multiple perspectives imaging,' Appl. Opt. vol. 40, pp. 3318-3325, 2001   DOI   ScienceOn
12 J.-S. Park, D.-C. Hwang, D.-H. Shin and E.-S. Kim, "Resolution-enhanced three-dimensional image correlator using computationally reconstructed integral images," Opt. Commun. Vol. 26, pp. 72-79, 2007   DOI   ScienceOn
13 M. Mart$\acute{i}$nez-Corral, B. Javidi, R. Mart$\acute{i}$nez-Cuenca, and G. Saavedra, "Multifacet structure of observed reconstructed integral images," J. Opt. Soc. Am. A vol. 22, pp. 597-603, 2005   DOI   ScienceOn
14 D. -H. Shin, B. Lee, and E. -S. Kim, "Multidirectional curved integral imaging with large depth by additional use of a large-aperture lens," Appl. Opt. vol. 45, pp. 7375-7381, 2006   DOI   PUBMED
15 D.-H. Shin and H. Yoo, "Image quality enhancement in 3D computational integral imaging by use of interpolation methods," Opt. Express vol. 15, pp. 12039-12049, 2007   DOI   PUBMED
16 H. Yoo and D.-H. Shin, "Improved analysis on the signal property of computational integral imaging system," Opt. Express vol. 15, pp. 14107-14114, 2007   DOI   PUBMED