• 제목/요약/키워드: 집적광학 바이오센서

검색결과 15건 처리시간 0.021초

SOI 슬롯 광도파로 기반 캐스케이드 링 공진기 바이오·케미컬 집적광학 센서의 효용성 해석 (Application Utility Analysis of Series-cascaded Ring Resonators Based on SOI Slot Optical Waveguides in Integrated Optical Biochemical Sensor)

  • 장재식;정홍식
    • 센서학회지
    • /
    • 제31권5호
    • /
    • pp.353-359
    • /
    • 2022
  • This study investigated via computational analysis the application utility of series-cascaded ring resonators based on silicon-on-insulator (SOI) slot optical waveguides in integrated optical biochemical sensors. The radii of the two rings in the series-cascaded ring resonators were 59.4 ㎛ and 77.6 ㎛ respectively, and the coupling distance was 0.5 ㎛. The series-cascaded ring resonators were computationally analyzed using FIMMProp and PICWave numerical software. The free spectral range (FSR), full width at half maximum (FWHM), sensitivity, and quality-factor (Q-factor) of the series-cascaded ring resonators were 12.2 nm, 0.134 nm, 4100 nm/RIU, and 11580, respectively, and the measurement range was calculated to be slightly smaller than 3×10-3 RIU. Although the measurement range was smaller than that of the single ring resonator, upon considering other characteristic parameters, the series-cascaded ring resonators are found to be more effective as integrated sensors than single ring resonators.

Si3N4 립-광도파로의 두-수평모드 파워결합과 소산파 기반 집적광학 바이오센서 설계 (Design of Integrated-Optic Biosensor Based on the Evanescent-Field and Two-Horizontal Mode Power Coupling of Si3N4 Rib-Optical Waveguide)

  • 정홍식
    • 센서학회지
    • /
    • 제29권3호
    • /
    • pp.172-179
    • /
    • 2020
  • We studied an integrated-optic biosensor configuration that operates at a wavelength of 0.63 ㎛ based on the evanescent-wave and two horizontal mode power coupling of Si3N4 rib-optical waveguides formed on a Si/SiO2/Si3N4/SiO2 multilayer thin films. The sensor consists of a single-mode input waveguide, followed by a two-mode section which acts as the sensing region, and a Y-branch output for separating the two output waveguides. The coupling between the two propagating modes in the sensing region produces a periodically repeated optical power exchanges along the propagation. A light power was steered from one output channel to the other due to the change in the cladding layer (bio-material) refractive index, which affected the effective refractive index (phase-shift) of two modes through evanescent-wave. Waveguide analyses based on the rib optical waveguide dimensions were performed using various numerical computational software. Sensitivity values of 12~23 and 65~165 au/RIU, respectively for the width and length of 4 ㎛, and 3841.46 and 26250 ㎛ of the two-mode region corresponding to the refractive index range 1.36~1.43 and 1.398~1.41, respectively, were obtained.

UV 임프린트 공정을 이용한 평면 광회로 기반 형광 산소 센서 프로브 모듈 제작 (Fabrication of Fluorescent Oxygen Sensor Probe Module Based on Planner Lightwave Circuits using UV Imprint Lithography)

  • 안기도;오승훈
    • 마이크로전자및패키징학회지
    • /
    • 제25권3호
    • /
    • pp.37-41
    • /
    • 2018
  • 본 논문에서는 UV 임프린트 기반의 평면 광 회로층을 이용한 산소농도 검출용 집적형 형광 프로브 모듈을 제안하였다. 제안된 형광 프로부 모듈은 광원과 형광 신호를 고효율로 전송할 수 있게 동일 광 경로를 가지는 비대칭 $1{\times}2$ 빔 분배기 형태로 설계되었으며, 이를 UV 임프린트 공정을 통해 제작하였다. 제작된 광 회로층의 끝단에 최적의 형광 염료 농도로 센서막을 코팅하여 산소 농도 검출용 광학 프로브 모듈을 구현하였다. 제작된 형광 프로부 모듈을 이용한 산소 농도 측정용 센서 시스템은 0%에서 20%의 가스 농도 범위에서 약 0.3%의 분해능까지 산소 농도를 검출 할 수 있었다. 이러한, 평면 광회로 기반의 형광 프로브 모듈은 저가의 집적형 산소 센서 검출 시스템을 가능하게 하여, 화학분야, 바이오 분야, 그리고 대기 및 수질 환경을 모니터링 하는 분야에 적용될 수 있을 것으로 기대된다.

집적광학 바이오케미컬 센서에 적합한 Si3N4/SiO2 슬롯 및 릿지-슬롯 광 도파로 제원 최적화 및 감지도 해석 (Specification optimization and sensitivity analysis of Si3N4/SiO2 slot and ridge-slot optical waveguides for integrated-optical biochemical sensors)

  • 장재식;정홍식
    • 센서학회지
    • /
    • 제30권3호
    • /
    • pp.139-147
    • /
    • 2021
  • Numerical analysis was performed using FIMMWAVE to optimize the specifications of Si3N4/SiO2 slot and ridge-slot optical waveguides based on confinement factor and effective mode area. The optimized specifications were confirmed based on sensitivity in terms of the refractive index of the analyte. The specifications of the slot optical waveguide, i.e., the width of the slot and the width and height of the rails, were optimized to 0.2 ㎛, 0.46 ㎛, and 0.5 ㎛ respectively. When the wavelength was 1.55 ㎛ and the refractive index of the slot was 1.3, the confinement factor and effective mode area of 0.2024 and 2.04 ㎛2, respectively, were obtained based on the optimized specifications. The thickness of the ridge and the refractive index of the slot were set to 0.04 ㎛ and 1.1, respectively, to optimize the ridge-slot optical waveguide, and the confinement factor and effective mode area were calculated as 0.1393 and 2.90 ㎛2, respectively. When the confinement coefficient and detection degree of the two structures were compared in the range of 1 to 1.3 of the analyte index, it was observed that the confinement coefficient and sensitivity were higher in the ridge-slot optical waveguide in the region with a refractive index less than 1.133, but the reverse situation occurred in the other region. Therefore, in the implementation of the integrated optical biochemical sensor, it is possible to propose a selection criterion for the two parameters depending on the value of the refractive index of the analyte.

SOI 슬롯 광 도파로를 활용한 2×2 Balanced-Bridge Mach-Zehnder 간섭형 집적광학 바이오케미컬 센서 설계 및 성능평가 (Design and Performance Evaluation on 2×2 Balanced-Bridge Mach-Zehnder Interferometric Integrated-Optical Biochemical Sensors using SOI Slot Optical Waveguides)

  • 정홍식
    • 센서학회지
    • /
    • 제32권4호
    • /
    • pp.223-231
    • /
    • 2023
  • An integrated-optical biochemical sensor structure that can perform homogeneous and surface sensing using a 2×2 balanced-bridge Mach-Zehnder interference structure based on the optimized SOI slot optical waveguide was described, and its performance and characteristics were evaluated. Equations for the two output optical powers were derived and examined using the transfer matrices of a 3-dB coupler and phase shifter (channel waveguide). The length of the 3-dB coupler was determined such that the two output optical powers were same using these formulas. In homogeneous sensing, the effect of the refractive index of an analyte in the range of 1.33-1.36 on the two output optical power distributions was numerically derived, and the sensitivity was calculated based on each output and the difference between the two outputs, the former and the latter being 7.5796-19.0305 [au/RIU] and 15.2601-38.1351 [au/RIU], respectively. In the case of surface sensing, the sensitivity range of the refractive index of 1.337 based on each of the two outputs was calculated as -2.2490--3.5854 [au/RIU] and 1.2194-3.8012 [au/RIU], and the sensitivity range of 4.8048-7.0694 [au/RIU] was confirmed based on the difference between the two outputs.