• Title/Summary/Keyword: 질량감소량

Search Result 222, Processing Time 0.028 seconds

Design of Battery-Supporting Structure for Reducing Deflection of On-Line Electric Vehicles (OLEV의 처짐량 개선을 위한 배터리 지지구조물 설계)

  • Park, Hong-Ik;Yoo, Ji-Sue;Lee, Jun-Young;Lee, Sang-Beom;Yim, Hong-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.2
    • /
    • pp.211-216
    • /
    • 2012
  • This paper presents methods to reduce the deflection of the battery-supporting structure on on-line electric vehicles (OLEVs). First, by testing various battery locations, a location is found that increases the dynamic stiffness of the OLEV. Second, static analysis is conducted to analyze the maximum deflection caused by the battery weight. In order to reduce the amount of deflection, the contributions of the battery-supporting structures are analyzed, and reinforcements are inserted. Then, another static analysis is conducted to compare the results of the base model and modified model. Consequently, through the static analysis, both the base model and modified model are similarly improved in terms of deflection, but the modified model is better than the base model at reducing the mass.

Effects of the Geometry and Location of an Vertical Opening on the Fire Characteristics in the Under-Ventilated Compartment Fire (환기부족 구획화재에서 수직 개구부의 형상 및 위치가 화재특성에 미치는 영향)

  • Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.20-29
    • /
    • 2013
  • To investigate numerically the effects of geometry and location of vertical opening on the thermal and chemical fire characteristics in full-scale under-ventilated compartment fires, the ventilation factor ($A\sqrt{h}$) to estimate a theoretical maximum inflow of ambient air and the mass loss rate in a heptane pool fire were fixed for all cases. It was shown that variations in door geometry affected significantly the change in thermal and chemical characteristics inside the compartment. Variations in window location resulted in the complex change in additional fire characteristics including the fire duration time and recirculating flow structure. These results were analyzed in details by the multi-dimensional flow and fire characteristics including the vent flow and fuel/air mixing phenomena.

A Damage Assessment Technique for Bridges Using Static Displacements (정적변위를 이용한 교량의 손상도 평가기법)

  • Choi, Il Yoon;Cho, Hyo Nam
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.5 s.60
    • /
    • pp.641-646
    • /
    • 2002
  • A new damage detection technique using static displacement data was developed, in order to assess the structural integrity of bridge structures. In conventional damage assessment techniques using dynamic response, the variation of natural frequencies is intrinsically insensitive to the damage of the bridge: thus, it is usually difficult to obtain them from the measured data. The proposed detection method enables the estimation of the stiffness reduction of bridges using the static displacement data that are measured periodically, without requiring a specific loading test. Devices such as a laser displacement sensor can be used to measure static displacement data due to the dead load of the bridge structure. In this study, structural damage was represented by the reduction in the elastic modulus of the element. The damage factor of the element was introduced to estimate the stiffness reduction of the bridge under consideration. Likewise, the proposed algorithm was verified using various numerical simulations and compared with other damage detection methods. The effects of noise and number of damaged elements on damage detection were also investigated. Results showed that the proposed algorithm efficiently detects damage on the bridge.

Rapid Detection of Salmonella spp. by Antibody Immobilization with Gold-protein A Complex (Gold-protein A Complex 항체 고정화법을 이용한 Salmonella spp.의 신속 검출)

  • Park, In-Seon;Kim, Nam-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 1999
  • A piezoelectric (PZ) biosensor system detecting Salmonella spp. was developed. The system consisted of an oscillator, a frequency counter and an antibody-immobilized quartz crystal. An anti-Salmonella antibody was immobilized on one gold. surface of the quartz crystal with protein A. Salmonella detection was made by measuring resonant frequency shift owing to a mass change by specific binding of microbial cells to the gold surface of the PZ crystal. The PZ antibody sensor was operated optimally at 0.1M phosphate buffer, pH 7.2 and $35^{\circ}C$. The sensor was quite specific to Salmonella spp. The obtained frequency shift was correlated with the Salmonella concentration in the range of $10^5{\sim}10^6\;CFU/mL$. The frequency shift increased further by addition of polystyrene beads. The Salmonella detection which is indicated by a steady-state microbial adsorption to the quartz crystal was accomplished within 50min.

  • PDF

Spalling Resistance of High Strength Concrete Using Non-Stripping Form (비탈형 거푸집에 의한 고강도 콘크리트의 폭렬방지)

  • You, Ji-Young;Han, Chang-Pyung;Jee, Suk-Won;Han, Min-Cheol;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.865-868
    • /
    • 2008
  • As a part of a series of study, this study reviewed the fire proof characteristics of high performance concrete RC column members using non-stripping form that accompanied metal lath lateral confinement to prevent spalling of high performance concrete which is increasingly used recently, and the results are as follows. Flow and air amount both satisfied target range, and compressive strength, over 80MPa at age 28 days, showed high strength range. As for spalling characteristics, in the case of plain in which no fiber is mixed, severe spalling occurred, and in the case of 0.05% nylon("NY" hereinafter)+polypropylene("PP" hereinafter) fiber mixture, only surface area experienced partial spalling. Regarding non-stripping form changes, both non-stripping 25-20 and non-stripping 50-20 experienced spalling at finish material area, and non-stripping 50-20 showed better spalling proof performance than non-stripping 25-20. In the case of non-stripping 50-40, spalling was prevented, and while mass reduction rate was less than 10%, its temperature hysteresis showed the most excellent fire proof performance with base metal surface area maximum temperature $376.1^{\circ}C$.

  • PDF

Theoretical Model of Coaxial Twin-Fluid Spray In a Liquid Rocket Combustor (연소실 내 동축형 2-유체 분무의 이론적 모델)

  • 조용호;윤웅섭
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.2
    • /
    • pp.37-44
    • /
    • 2002
  • A theoretical study of spray and combustion characteristics due to coaxial twin-fluid injection is conducted to investigate the effects of liquid jet property, droplet size, contact length and liquid jet velocity. Model is properly validated with measurements and shows good agreement. Prediction of jet contact length, droplet size, liquid jet velocity reflects genuine features of coaxial injection in physical and practical aspects. Both the jet contact length and tile droplet size are reduced in a linear manner with an increase of injector diameter. Cross sectional area of liquid intact core is reduced with augmented jet splitting rate, thus the jet is accelerated to maintain the mass continuity and with an assistant of momentum diffusion by burnt gas.

Change of AMC due to Climatic Change (기후변화에 따른 선행토양함수조건(AMC)의 변화)

  • Yoo, Chulsang;Park, Cheong Hoon;Kim, Joong Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3B
    • /
    • pp.233-240
    • /
    • 2006
  • One of the main factor that effects on the CN's value in SCS Curve Number method for the estimation of direct runoff is the antecedent soil moisture condition (AMC). It is also common to use the AMC-III in hydrologic practice, which provides the largest runoff as possible. In this paper, AMC defending on the rainfall characteristics is analyzed using daily rainfall data at rainy season (June~September) of the Seoul station from 1961 to 2002. The probability mass function of AMC is also investigated to analyze the variation of AMC based on climate change, scenarios from several General Circulation Model (GCM) predictions. As a results we can find that the occurrence of AMC-I is reduced, and AMC-III is increased, whereas AMC-II does not change.

Changes of Body Composition and Aging-related Hormones by Rhythmic Exercise Program in Elderly Women (율동적 운동에 따른 여성 노인의 체구성 및 노화관련 호르몬 변화)

  • Cha, Kwang Suk;Sung, Dong Jun
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.933-946
    • /
    • 2010
  • The purpose of this study was to examine the changes of body composition and aging-related hormones by rhythmic exercise in elderly women. The subjects in this study were 20 olders living in a rural community, >60 years of age and were performed rhythmic exercise program during 12 weeks. The measurement of the body composition, body mass (t=3.125, p=.006), body mass index (t=3.225, p=0.004), body fat mass (t=3.782, p=0.001), waist-to-hip ratio (t=3.867, p=0.001) were significant difference after exercise program, but had no effect on lean body mass. Also, growth hormone (t=-2.221, p=0.039) and somatomedin-C (t=-9.186, p=0.000) were significantly increased after rhythmic exercise, however, rhythmic exercise had no effect on DHEA-S. These results suggest that rhythmic exercise appeared to effect of control on body composition and some aging-related hormones in elderly women.

Combustive Properties of Medium Density Fibreboard (MDF) Specimens Treated with Alkylenediaminoalkyl-Bis-Phosphonic Acid Derivatives (알킬렌디아미노알킬-비스-포스폰산 유도체에 의해 처리된 중밀도섬유판의 연소성)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.57-63
    • /
    • 2014
  • This study was performed to test the combustive properties of Medium Density Fibreboard (MDF) specimens treated with piperazinomethyl-bis-phosphonic acid (PIPEABP), methylpiperazinomethyl-bis-phosphonic acid (MPIPEABP), and N,N-dimethylethylenediaminomethyl-bis-phosphonic acid (MDEDAP). MDF Plates were painted in three times with 15 wt% solution of the alkylenediaminoalkyl-bis-phosphonic acids at the room temperature, respectively. After drying specimen treated with chemicals, combustive properties were examined by the cone calorimeter (ISO 5660-1). It was indicated that the specimens treated with chemicals showed the later time to peak mass loss rate ($TMLR_{peak}$) = (340475) s than that of virgin plate by reducing the burning rate. In adition, the specimens treated with chemicals showed the higher $CO_{mean}$ production (0.0883~0.0963) kg/kg than that of virgin plate. Especially, the specimens treated with chemicals showed the higher mean smoke extinction area ($SEA_{mean}$) ($5m^2/kg{\sim}21.5m^2/kg$) than that of virgin plate. Thus, It is supposed that the combustion-retardation properties were improved by the partial due to the treated alkylenediaminoalkyl-bis-phosphonic acids in the virgin MDF Plate. However, It gave a negative effect on smoke reduction.

The Thermal Conduction Property of Structural Concrete using Insulation Performance Improvement Materials (단열성능향상 재료를 사용한 구조용 콘크리트의 열전도 특성)

  • Park, Young-Shin;Kang, Min-Gi;Kim, Jung-Ho;Ji, Suk-Won;Jeon, Hyun-Kyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.1
    • /
    • pp.9-15
    • /
    • 2016
  • The part of a building with the biggest energy loss is the exterior and many studies are actively conducted to reduce the energy loss on that part. However, most studies consider the window frames and insulation materials, but many studies do not discuss the concrete that takes more than 70% of the exterior. In order to minimize the energy loss of buildings, it is necessary to enhance the concrete's insulation performance and studies need to be conducted on this. Therefore, this study used a micro foam cell admixture, calcined diatomite powder, and lightweight aggregates as a part of a study to develop a type of concrete with improved insulation performance that has twice higher thermal conductivity compared to concrete. It particularly secured the porosity inside concrete to lower thermal conductivity. As a result of the experiment, the slump and air capacity showed fair results, but all mixtures containing micro foaming agent showed 14.3~35.1% lower mass per unit of volume compared to regular concrete. Compressive strength decreased slightly due to the materials used to improve the insulating performance, but it all satisfied this study's target strength(24MPa). Thermal conductivity was up to twice higher than that of regular concrete.