• Title/Summary/Keyword: 진폭비

Search Result 726, Processing Time 0.024 seconds

Polarization Filters Using the Multicomponent Complex Trace Analysis (다성분 복소트레이스를 이용한 분극필터)

  • Kim, Ki-Young;Lee, So-Young
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.89-94
    • /
    • 2006
  • In order to increase the signal-to-noise ratio in multi-component seismic data, we developed new polarization filters based on the method of multicomponent complex trace analysis. Unlike the previous polarization filters, the present filters separately compute linear and elliptic components at each time sample using amplitude ratio of horizontal and vertical components of body waves and ellipticity of Rayleigh waves. The polarization filters work ideally even with low S/N data. Application of the filters to both synthetic and real seismic data shows that Rayleigh waves of elliptic motions are effectively eliminated and both P and S waves of linear motions are well separated each other.

  • PDF

Implementation of Nonlinear SVM for HD Projection TV (HD Projection TV를 위한 비선형 SVM 회로의 구현)

  • Lee, Gwang-Sun;Gwon, Yong-Dae;Lee, Geon-Il;Song, Gyu-Ik;Choe, Deok-Gyu;Han, Chan-Ho;Kim, Eun-Su
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.2
    • /
    • pp.191-198
    • /
    • 2001
  • As a method to compensate the deterioration of the picture quality which was caused by beam profile characteristic in the CRT and the projection screen of HD projection TV, a linear scan velocity modulation(SVM) method has been employed, whose modulation velocity is linearly proportional to the variation in the video signal amplitude. However, the effect of picture quality improvement is not uniform with video signal amplitude in the linear SVM. In this paper, for the optimum SVM effect, we analyze the beam profile characteristic on the HD projection screen and we analyze the SVM effect as function of the differentiated pulse width, the differentiated pulse amplitude and the input signal amplitude. Finally we confirm that the nonlinear SVM method is necessary to get uniform image compensation in the HD projection TV, and we implement the nonlinear SVM circuit. The performance of the realized SVM circuit with nonlinear amplitude transfer characteristic is confirmed as uniform improvements in picture quality.

  • PDF

An Experimental Evaluation on Vibration Serviceability of Existing Bridge by Non-contact Vibration Measurement Method (비부착식 진동측정방법에 의한 공용중 교량의 진동사용성에 대한 실험적 평가)

  • Shin, Hyun-Seop;Park, Ki-Tae;Lee, Kyu-Wan;Jun, Jin-Taek
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.254-262
    • /
    • 2010
  • In order to evaluate vibration serviceability by means of non-contact vibration meter, serviceability of existing bridge were experimentally evaluated by using laser vibration meter. Test results were analyzed and compared with evaluation results acquired by using accelerometer and LVDT. To testify accuracy of laser vibration meter measured natural frequency were compared with that acquired by using accelerometer. According to test and comparison results it is showed that serviceability can be evaluated properly enough from the tolerance curve of Reiher-Meister for the estimated acceleration that can be calculated by the numerical differentiation of measured velocity. But because of cumulative numerical error occurred during integration of measured velocity in the time domain serviceability grade could be different from the result acquired by LVDT.

Application of Amplitude Demodulation to Acquire High-sampling Data of Total Flux Leakage for Tendon Nondestructive Estimation (덴던 비파괴평가를 위한 Total Flux Leakage에서 높은 측정빈도의 데이터를 획득하기 위한 진폭복조의 응용)

  • Joo-Hyung Lee;Imjong Kwahk;Changbin Joh;Ji-Young Choi;Kwang-Yeun Park
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.17-24
    • /
    • 2023
  • A post-processing technique for the measurement signal of a solenoid-type sensor is introduced. The solenoid-type sensor nondestructively evaluates an external tendon of prestressed concrete using the total flux leakage (TFL) method. The TFL solenoid sensor consists of primary and secondary coils. AC electricity, with the shape of a sinusoidal function, is input in the primary coil. The signal proportional to the differential of the input is induced in the secondary coil. Because the amplitude of the induced signal is proportional to the cross-sectional area of the tendon, sectional loss of the tendon caused by ruptures or corrosion can be identified by the induced signal. Therefore, it is important to extract amplitude information from the measurement signal of the TFL sensor. Previously, the amplitude was extracted using local maxima, which is the simplest way to obtain amplitude information. However, because the sampling rate is dramatically decreased by amplitude extraction using the local maxima, the previous method places many restrictions on the direction of TFL sensor development, such as applying additional signal processing and/or artificial intelligence. Meanwhile, the proposed method uses amplitude demodulation to obtain the signal amplitude from the TFL sensor, and the sampling rate of the amplitude information is same to the raw TFL sensor data. The proposed method using amplitude demodulation provides ample freedom for development by eliminating restrictions on the first coil input frequency of the TFL sensor and the speed of applying the sensor to external tension. It also maintains a high measurement sampling rate, providing advantages for utilizing additional signal processing or artificial intelligence. The proposed method was validated through experiments, and the advantages were verified through comparison with the previous method. For example, in this study the amplitudes extracted by amplitude demodulation provided a sampling rate 100 times greater than those of the previous method. There may be differences depending on the given situation and specific equipment settings; however, in most cases, extracting amplitude information using amplitude demodulation yields more satisfactory results than previous methods.

Acoustic Nonlinearity of Narrow-Band Surface Wave Generated by Laser Beam with Line-Arrayed Slit Mask (선배열 슬릿마스크를 이용한 협대역 레이저 여기 표면파의 음향 비선형성)

  • Choi, Sung-Ho;Nam, Tae-Hyung;Lee, Tae-Hun;Kim, Chung-Seok;Jhang, Kyung-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1877-1883
    • /
    • 2010
  • We examined the mechanism of generation of higher harmonics by theoretically analyzing the frequency characteristics of a narrow-band surface wave generated by a laser beam with line-arrayed slit masks. We experimentally analyzed the effects of slit opening width and laser intensity on the acoustic nonlinearity of aluminum 6061-T6 alloy by using single-slit and line-arrayed slit masks. The magnitude of the harmonic wave depended on the slit opening width. In our experiment, we generated a 1.75-MHz surface wave by using an arrayed slit with intervals of 1.67 mm. The magnitude of the second harmonic component decreased about by 80% when the slit opening width was increased from 0.5 mm to 1.0 mm. In addition, the relationship between the magnitudes of the fundamental and the second harmonic wave showed good linearity, which agreed well with the typical behavior of acoustic nonlinearity.

A Study on Implemetation of Non-invasive Blood Pressure (비침습적 혈압 측정 시스템 구현에 관한 연구)

  • 노영아;이종수;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.451-454
    • /
    • 2000
  • Invasive methode and Non-invasive methode are used in blood pressure measurement. The Invasive methode can Set the correct measured blood pressure but, it has patient feels uncomfortable. So most of cases use Non-invasive methode. The Oscillometric method is commonly apply to modem electric sphygmomanometer and using various algorithm. In this paper describe about a algorithm it control and to determinate the cuff pressure, and filtering that data for measure the blood pressure. The communicating with personal computer can pressure deflation is by Solenoid valve and it uses RS-232 system in packet communication. The main using algorithm for blood pressure measurements are maximum amplitude algorithm and oscillometric algorithm. MAA(maximum amplitude algorithm) has various measured oscillation it depend on patient's age, height, weight and arm circumference size. In this paper, 1 studied the various measured oscillation apply to characteristic ratio and can get the result of systolic blood pressure, diastolic blood pressure, mean blood pressure. It was not used same ratio to measuring oscillation. In the MAA(maximum amplitude algorithm), we hope for reduce the difference with the real blood pressure and the measured blood pressure, when it applied with various specific ratio.

  • PDF

The Characteristics of Acoustic Emission Signal under Composite Destruction on GFRP Gas Cylinder (유리섬유강화 복합재료 가스실린더의 복합재료 파괴시 발생하는 음향방출 특성)

  • Jee, Hyun-Sup;Lee, Jong-O;Ju, No-Hoe;So, Cheal Ho;Lee, Jong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.430-435
    • /
    • 2013
  • This study is investigation of the characteristics for acoustic emission signal generated by destruction on glass fiber bundles and specimen that was machined composite materials surrounding the outside of GFRP cylinder. The Amplitude of acoustic emission signal gets bigger as the cutting angle of knife increases. Accordingly, the number of hits in destruction of composite materials specimen have more in longitudinal direction (longitudinal direction to the glass fiber) than in hoop direction (horizontal direction to the glass fiber) while the amplitude of signals were bigger in hoop direction than longitudinal direction. It was found out that the amplitude of the glass fiber breakage is more than 40 dB and that the amplitude of signal for matrix crack was less than 40 dB because matrix crack signal was not observed when threshold value is 40 dB and matrix crack signal suddenly appered when threshold value is 32 dB. The slope of the amplitude is related to the acoustic emission source and the slope of the amplitude of the horizontal and vertical directions are 0.16 and 0.08. In particular, The slope of the amplitude of longitudinal direction breakage appear similar to the glass fiber breakage and therefore Acoustic emission source of longitudinal direction breakage is estimated the glass fiber breakage.

IRF performance prediction by analyzing of amplitude and phase errors for the wideband Chirp signal (광대역 첩 신호의 진폭 및 위상오차 분석을 통한 IRF 성능 분석)

  • Kim, Dong-Sik;Kim, Jong-Pil;Lee, Jong-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.2
    • /
    • pp.131-138
    • /
    • 2016
  • In this paper, we studied the IRF performances of the chirp signal used in the SAR system. The most important factors that degrade IRF performances are amplitude and phase errors. Each factor can be represented to linear, quadratic, random and ripple terms. That can be extracted by a quadratic polynomial curve fitting of chirp waveform. We analyzed the IRF performances by the error terms and supposed the minimum value of RF non-linearity to meet the specification of the PSLR and ISLR.

Performance Improvement of OFDM Receivers by Using Rational Oversampling of the Received Signals (수신신호의 비정수배 과표본화를 이용한 OFDM 수신기의 성능 개선)

  • Lee, Young-Su;Seo, Bo-Seok
    • Journal of Digital Contents Society
    • /
    • v.10 no.2
    • /
    • pp.189-198
    • /
    • 2009
  • In this paper, we propose a method to improve the performance of orthogonal frequency division multiplexing (OFDM) receivers by using oversampling the received signals. Demodulation of the received OFDM signals is to detect the amplitude and phase components of the subcarriers. From the oversampled OFDM signals, we can get redundant informations in frequency domain for the data, which are different in phase but the same in amplitude. By using these properties, we can obtain signal to noise ratio (SNR) gain by the oversampling ratio compared to the receivers which sampled with symbol rate. In this paper, we propose oversampled receivers whose oversampling ratio is expanded from integer to general rational number. Through computer simulations, we show the validity of the proposed methods by comparing the performance of the receivers with nonideal band-limiting filters.

  • PDF

A Study of Non linear Acoustic Response from Defect in a Plate (평판에서 미세틈새에 의한 비선형 음향반응 연구)

  • Park Rae Buem;Jung Kyoung Il;Yoon Suk Wang
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.307-310
    • /
    • 2000
  • 평판에서 발생되는 램파가 물체 내에 존재할 수 있는 미세 결함과의 상호작용에 의해 비선형 음향효과를 발생시키는지 관찰하고 이로부터 결함의 존재 유$\cdot$무를 확인하고자 했다. 이차원의 판형 매질로서 $2000{\times}110{\times}2{\cal}mm^3$인 강철판을 사용했으며 결함은 강철판의 임의의 위치에 인위적으로 미세틈새를 형성하여 모델화시켰다. 488kHz의 저주파수 연속파와 톤버스트 형태의 1MHz 고주파수 음파를 입사시켰다. 결함의 유$\cdot$무에 따른 강철판에서의 수신음파에 대한 주파수 응답을 통하여 비선형 음향반응인 배진동 주파수와 합$\cdot$차 주파수의 발생을 관측함으로써 매질 내의 결함 유$\cdot$무를 판별하고자 했다. 결함이 존재할 경우, 존재하지 않을 경우와 비교했을 때 배진동 주파수는 진폭이 15dB, 합$\cdot$차주파수는 진폭이 18dB이상 증가됨을 관찰함으로써 평판에서의 결함의 존재 유$\cdot$무를 확인할 수 있었다.

  • PDF