• Title/Summary/Keyword: 진동 절연 장치

Search Result 38, Processing Time 0.026 seconds

Pyroshock Isolation Performance Test using Wiremesh Isolators (와이어메쉬 절연계의 파이로 충격 절연 성능 시험)

  • Youn, Se-Hyun;Jang, Young-Soon;Han, Jae-Hung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.9
    • /
    • pp.923-928
    • /
    • 2008
  • Pyrotechnic shock or pyroshock is characterized as a transient vibration phenomenon which shows large acceleration and high frequency range up to 10kHz during the operation of separation devices where explosives are used. During the flight of a launch vehicle, pyroshock is mainly generated at several events such as satellite separation, fairing separation and stage separation. In this paper, wiremesh isolators are introduced and several types of isolators are manufactured for the performance tests. For the investigation of typical characteristics of wiremesh isolators, compressive loading tests are basically performed and pyroshock tests are accomplished to confirm pyroshock isolation ability of each wiremesh isolator by using 4Kg dummy mass.

A Study on the Improvement of Voltage Measuring Method of 22.9 kV-y Distribution Lines (22.9 kV-y 배전선로의 전압계측방법 개선에 관한 연구)

  • Kil, Gyung-Suk;Song, Jae-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.293-299
    • /
    • 1998
  • An objective of this study is to develop a voltage measuring device that uses a gas-filled switch (GS) on 22.9 kV-y extra-high voltage distribution lines. The voltage measuring device proposed in this paper is a kind of capacitive divider which consists of a detecting electrode attached outside of the bushing of GS, an impedance matching circuit, and a voltage buffer. It can be easily installed in an established GS without changing the structure. For the calibration and application investigations, the voltage measuring device was set up in the 25.8 kV 400 A GS, and a step pulse generator having 5 ns rise time is used. As a result, it was found that the frequency bandwidth of the voltage measuring device ranges from 1.35 Hz to about 13 MHz. The error of voltage dividing ratio which is evaluated by the commercial frequency voltage of 60 Hz was less than 0.2%. In addition, voltage dividing ratio in the commercial frequency voltage and in a non-oscillating impulse voltage were compared, and their deviation were less than 0.7%.

  • PDF

신자재: 방진 및 내진용 배관 고정장치 개발 - 주헌건설(주)

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.247
    • /
    • pp.58-59
    • /
    • 2011
  • 주헌건설(주)은 지난해 6월 자체 개발한 내진 스프링가대가 특허(제10-0962993호)를 획득함에 따라 본격생산에 들어갔다. 내진 스프링가대는 펌프 등 실비기기의 자체진동을 방지하고 지진 발생시 충격을 흡수해 산재사고 예방 및 내진 안전성을 확보하는 장치이다. 이 제품은 지난 2010년 10월 "제4차 UN 재해위험 경감을 위한 아시아 각료회의"의 부대행사로 열린 재해경감 방재산업전에 출품해 호평을 받았다. 또한 배관의 신축 팽창을 자체 흡수하고 각종 슈 대신 절연 유볼트로 시공하므로 원가절감 효과가 있으며 타 공정과의 간섭 없이 시공할 수 있는 장점이 있다.

  • PDF

Dynamic Characteristics Analysis of Closing Resistors of Gas Insulated Switchgear (가스절연 개폐장치 투입저항의 동특성 해석)

  • Cho Hae-Yong;Lee Sung-Ho;Lim Sung-Sam;Lee Ki-Joung;Kim Min-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.104-110
    • /
    • 2005
  • GIS(Gas Insulated Switchgear) is used in electric power system, to insure non conductivity, breaking capacity and operating reliability. The commercial dynamic analysis code COSMOS MOTION and 3-D modeling program SOLID WORKS were used to simulate dynamic analysis of the closing resistors of the GIS in this paper. To reduce chatter vibration of closing resistors, the motion of moving and fixed parts of closing resistors were simulated by varying the spring constant, the damping coefficient and the mass of moving and fixed parts. The simulated results were compared with experimental results. As a result, chatter vibration of closing resistors of the GIS could be reduced by using the results. These data can be used to determine the spring constant, the damping coefficient and mass of a moving part to reduce chatter vibration when the next model is developed.

Vibration Reduction Device for Directional Moving Satellite Antenna (지향성을 가지고 동작하는 위성 안테나 진동저감 장치 )

  • SeokWeon Choi;Sang-Soon Yong
    • Journal of Space Technology and Applications
    • /
    • v.2 no.3
    • /
    • pp.187-194
    • /
    • 2022
  • Although the magnitude of the disturbance caused by the driving of the motor operated to secure the high-speed and precise directivity of the antenna is small, it acts as a major cause of impairing the image quality of the observation satellite, which requires precision directing performance. In order to acquire high-resolution image information through the improvement of the high-resolution observation satellite, proper vibration isolation and reduction design are required so that jitter generated when the directional antenna motor is driven is not transmitted to the main mission equipment. In this paper, the development process of the directional antenna vibration reduction device applied to real satellites and the effect of micro vibration reduction before and after application will be examined. This device was designed as a way to significantly improve the jitter problem by replacing only one gear in the directional antenna driving unit with a spring damper gear without any additional interface equipment. It was first applied and launched to a high-resolution earth observation satellite, and has been successfully operated so far.

Analysis of Isolation System for Impulsive Force Device with Recoil Mechanism (반동방식 충격기구의 완충시스템 해석)

  • Kim, HyoJun;Ryu, BongJo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.272-279
    • /
    • 2005
  • In this study the optimal isolation system for the prototype HIFD(high impulsive force device) is investigated. For this purpose, firstly, the dynamic behavior of a human body and a transmitted force under specific operation conditions are analyzed through a series of experimental works using the devised test setup. In order to design the optimal dynamic absorbing system, the parameter optimization process is performed using the simplified isolation system model based on the experimental results of linear impulse and transmitted force. Finally, under the parameters satisfying the constraints of the buffering displacement and the transmitted force, the performance of the designed isolation system for the prototype HIFD is evaluated by experiment.

Analysis of the Vibration Transmitting Characteristics of the Insulation-foam for Reducing Refrigerant-induced Noise of a Refrigerator (냉장고 냉매소음 저감을 위한 단열 발포재의 진동 전달특성 분석)

  • Han, Hyung-Suk;Kim, Min-Sung;Jeong, Weui-Bong;Seo, Min-Young;Lee, Soo-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.1
    • /
    • pp.45-50
    • /
    • 2010
  • In the refrigerator, the two-phase refrigerant-induced noise of the capillary tube in an evaporator-inlet pipe has been a great concern. The capillary tube is usually covered with insulation-foam packed in the space between inner and outer cabinets without any vibration isolation. Therefore, the refrigerant-induced vibration of the capillary tube can be easily transferred to the outer cabinet, which may increase the radiated noise. In this paper, the characteristics of transferred vibration through the insulation-foam are investigated experimentally by using the refrigerantsupplying equipment. The frequency characteristics, such as dynamic Young's modulus and loss factor, of the insulation-foam are also discussed.

Study on Seismic Analysis and Test for Seismic Qualification of 245kV GIS (245kV 가스절연개폐장치의 내진성능 실증을 위한 시험 및 해석)

  • Kim, Yu-Gyeong;Kwon, Tae-Hoon;Jeong, Yeong-Jin;Kim, Hong-Tae;Kim, Young-Joong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.5
    • /
    • pp.715-722
    • /
    • 2013
  • Gas insulated switchgear is large-sized electric equipment for providing a reliable supply of electric power. Recently, seismic tests of electric equipment using a shaking table have been mandated because seismic performance has become an increasingly important issue. However, basic analysis methods continue to be used because some electric equipment is too large for shaking table facilities. Thus, a reliable analysis method should be developed for large-scale electric equipment. This study aims to evaluate the seismic qualification of a 245kV GIS in accordance with IEEE-693 and to validate the analysis method by comparing it with test results. Both the test and the analysis showed that the 245kV GIS has proper seismic safety. Furthermore, the differences between the analysis and the test results are less than 10% for an accurately given mass, stiffness, and input acceleration. It is expected that this study can be used for the seismic qualification of large-scale electrical structures.

A Study on the improvement of damping and optimal design of beam flexure for the passive vibration isolator (수동형 음강성 저주파 제진기의 감쇠 성능 향상과 빔 유연체의 최적 설계에 관한 연구)

  • Lee, Gil-Yong;Chang, Hee-Doh;Park, Young-Ho;Park, In-Hwang;Han, Dong-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.189-195
    • /
    • 2008
  • The vibration isolator system(VIS) which has very low natural frequency could be designed by applying an axial compressive force to the beam-column flexure(BCF). In this paper a new shape of the BCF is suggested. It has stepwise axially varying properties by viscoelastic damping layer. So it has internal structural damping by damping layer during deformation. First the analytic solution is obtained for the BCF. And its critical load, buckling mode, stiffness and stress distributions are investigated. Also the dynamic properties of the VIS consist of the damping layered BCF are studied. Finally the optimal design procedure of damping layered BCF for the VIS is suggested. The improved performance of suggested VIS is verified by some experiments.

  • PDF

Development of Equipment to Measure Insulation Resistance and Evaluate the Lifetime of High-voltage Cable in Operation (운전 중인 고전압 케이블의 절연저항 측정 및 수명평가장치의 개발)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.237-242
    • /
    • 2014
  • In this paper, we find out the lifetime index in order to determine the time-dependent trend of deteriorating performance of 6.6kV high-voltage power cable in operation at a power station. The cable systems used in our study have been in operation for 13 years. With measurements for the 13 years, we analyzed the insulation resistances. By developing measuring equipment (comprized mainly of transformer, temperature sensor, and LPF) operating by the three-phase electric power, we analyzed the changing characteristics of insulation resistance of power cable. In contrast to 22kV cables, 6.6 kV cables have thicker insulation. Therefore the characteristics of 6.6kV cables are different from that of 22kV cables. The study found that as time passes, the insulation resistance does not decrease continuously; it decreases to a certain value, then does not decrease any more and shows properties of oscillation. We could not detect the process of deterioration in the preceding twelve years. The cable system showed great stability so that deterioration was not apparent. In this case, it is not possible to measure the future life indices of power cables because the lifetime indices are not predictable