• Title/Summary/Keyword: 진동대 실험

Search Result 372, Processing Time 0.026 seconds

Harmonic Excitation of Shear Building with Force-Controlled Shaking Table (힘-제어 진동대를 이용한 전단건물의 조화진동)

  • Lee, Sang Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.853-859
    • /
    • 2015
  • 1-DOF shear building was designed, built and tested to investigate the interactions between the shear building and the shaking table excited harmonically by the electro-magnetic forces. In the experiments horizontal accelerations of the shaking table and the shear building were measured. To understand the experimental results experimental setting was modeled as an unconstrained 2-DOF system under the hormonic forces. The responses of the shear building and the shaking table of the unconstrained 2-DOF system were found with the equations of motions. The magnification factors of the table and the shear building with respect to the amplitude of the harmonic forces and the transmission of the shear building with respect to the table excitations were found and compared with the experimental results.

Survey of Experimental Research Performed using Shaking Table Tests for Buildings in Korea (건축물의 진동대 실험을 이용한 국내 연구의 현황조사)

  • Lee, Han-Seon;Jung, Dong-Wook;Lee, Bo-Kyung;Kim, Hee-Cheul;Lee, Young-Hak;Lee, Ki-Hak
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.1-4
    • /
    • 2008
  • This study serveys the state of research performed using the shaking tables available in Korea for buildings. First, the parameters to describe the capacity of shaking tables are introduced. Then major shaking tables available in Korea, the size of which is larger than 2m ${\times}$ 2m, are summarised. Finally, the papers published in Korea which used these shaking tables are introduced. It is expected that this servey could contribute to the more active use of shaking tables in the future seismic engineering research.

  • PDF

Real-Time Hybrid Shaking Table Test of a Soil-Structure Interaction System with Dynamic Soil Stiffness (동적 지반강성을 갖는 지반-구조물계의 실시간 하이브리드 진동대 실험)

  • Lee, Sung-Kyung;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.2
    • /
    • pp.217-225
    • /
    • 2007
  • This paper proposes the real-time hybrid shaking table testing methods to simulate the dynamic behavior of a soil-structure interaction system with dynamic soil stiffness by using only a structure model as the physical specimen and verifies their effectiveness for experimental implementation. Experimental methodologies proposed in this paper adopt such a way that absolute accelerations measured from the superstructure and shaking table are feedback to the shaking table controller, and then the shaking table is driven by the calculated motion of the absolute acceleration (acceleration feedback method) or the absolute velocity (velocity feedback method) of foundation that is required to simulate the dynamic behavior of a whole soil-structure interaction system. The shaking table test is implemented by reflecting the dynamic soil stiffness, which are differently approximated from the theoretical one depending on the feedback methods, on the shaking table controller to calculate soil part. The effectiveness of the proposed experimental methods is verified by comparing the response measured from the test on a foundation-fixed structural model and that obtained from the experiment of a soil-interaction system under the consideration in this paper and by matching the dynamic soil stiffness reflected on the shaking table controller with that identified using the experimentally measured data.

Experimental Techniques for Evaluating Seismic Performance of Base-Isolated Structure (기초격리된 구조물의 내진성능평가를 위한 실험기법)

  • 윤정방;정우정;김남식;김두훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.4
    • /
    • pp.45-58
    • /
    • 1997
  • This paper describes a series of shaking table and pseudodynamic tests for evaluation of seismic performance of base-isolated structures subjected to various seismic earthquake inputs. The main objectives of this study are : (1) evaluation of the effectiveness of base-isolation systems for low-rise structures against severe seismic loads through shaking table tests, (2) verification of the substructuring pseudodynamic test method for the base-isolated structures in comparison with the shaking table test results. In the shaking table test, a quarter scaled three-story structure base-isolated by laminated rubber bearings is tested. In the pseudodynamic test, only the laminated rubber bearing s are tested using the substructuring technique, while the concurrent seismic responses of the superstructure are computed using on-line numerical integration. Comparison with the shaking table test results indicates that the substructuring pseudodynamic test method is very effective for determining the dynamic responses of the base-isolated structure.

  • PDF

Shaking Table Test for an Evaluation of the Limit State Capacity of an Anchor Foundation in the case of a Seismic Event (지진시 앵커기초의 한계성능 평가를 위한 진동대 실험)

  • Kim, Min-Kyu;Choi, In-Kil;Kwon, Hyung-O
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.23-31
    • /
    • 2010
  • In this study, a shaking table test was performed for the evaluation of the failure capacity of an anchor foundation system in the case of an aged condition. For the shaking table test, three kinds of specimens were manufactured as follows: 1) a non-damaged anchor; 2) a specimen with cracks running through the anchor; and 3) a specimen with cracks along the expected corn-shape fracture away from the anchor. A dynamic characteristic was determined through a measurement of the frequency response function (FRF), and the seismic capacity was evaluated by using a shaking table test. Failure capacities were calculated using an acceleration response and it was compared with the anchor design code.

Dynamic Characteristic of the Seismic Performance of Uninterruptible Power Supply with Combined Isolator Using Shaking Table Test (복합면진장치를 적용한 무정전전원장치의 1축 진동대실험 기반 동적특성 분석)

  • Lee, Ji-Eon;Lee, Seung-Jae;Park, Won-Il;Choi, Kyoung-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.19-28
    • /
    • 2022
  • In this study, three types of combined isolator consisting of High Damping Rubber Bearing (HDRB) and wire isolator were developed for Uninterruptible Power Supply system (UPS). The dynamic characteristics of the combined isolator were investigated through one-axis shaking table test. The input acceleration were generated in accordance with ICC-ES AC156 code. Scale factors of the input acceleration were designed to be 0.5-2 times the required response spectrum defined in ICC-ES AC156. Based on the test results, damage and dynamic characteristics of the UPS were investigated: including natural frequency, damping ratio, acceleration time history response, dynamic amplification factor and relative displacement. Based on that, it was found that the combined isolator developed in this study could improve the seismic behavior of the UPS, in particular, the response acceleration.

Estimation of Aseismatic Performance of Laminated Rubber Bearing Through Shaking Table Tests (진동대 실험을 통한 적층고무받침의 내진성능 평가)

  • Park, Seong-Kyu
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.4
    • /
    • pp.440-446
    • /
    • 2010
  • This paper was investigated on the laminated rubber bearing, which mitigates damages of bridges from threat of earthquakes. Laminated rubber bearing can bear large loads for long periods of time and be capable of large deformations during an earthquake. To evaluate seismic isolation with laminated rubber bearing on several earthquake waves, we performed a shaking table test. In this test, deck acceleration was measured by accelerometers and shear force on piers was surveyed by load cells. Furthermore, seismic capacity of isolated systems with laminated rubber bearing was compared with non-isolated systems through shaking table test. The results show that deck acceleration and shear force were relatively reduced by laminated rubber bearing.

Numerical Simulation on the Shaking Table Test considering Soil Structure Interaction (구조물과 지반의 동적 상호작용을 고려한 진동대 시험에 관한 수치 시뮬레이션)

  • Lee, Sung-Kyung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.5 s.45
    • /
    • pp.21-28
    • /
    • 2005
  • This paper proposes a shaking table test considering the dynamic soil strcuture interaction (SSI) by using the accelerations measured from superstructure and shaking table. The proposed method based on the substructure method is that only superstructure is used as an experimental model and dynamic soil stiffness is reflected on the controller of shaking table for soil model. At the moment, an experimental superstructure is excited by a shaking table with the motion required to emulate the dynamic behavior of total SSI system. First, the validity of the proposed method is verified by the verification model of numerical simulation, which is derived from the equation of motion of SSI system under consideration. Also, the applicability of the proposed method to shaking table test is numerically verified from the simulation model incorporating the transfer function of shaking table.

Shaking Table Tests of a 1/4-Scaled Steel Frame with Base Isolators (1/4축소 철골구조물을 이용한 건물 기초분리장치의 진동대실험)

  • 송영훈;김진구
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.39-48
    • /
    • 1997
  • New form of base isolators made of steel spring coated with both natural and artficial rubber were manufactured and tested for material properties. Shaking table experiments were performed using a model structure attached with the bearings. The model structure used in the test is a 1/4 scaled steel structure, and earthquake records were used to check the lateral and vertical stability and effectiveness of the isolators. According to the results all three types of isolators turned out to be effective in reducing the acceleration induced by the earthquake vibration.

  • PDF

Analytical Study on the Seismic Behavior of RC Bridge Columns Using Shaking Table Tests (진동대 실험을 통한 철근콘크리트 교각의 지진거동에 관한 해석적 연구)

  • Kim, Tae-Hoon;Park, Chang-Young;Chung, Young-Soo;Shin, Hyun-Mock
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.49-59
    • /
    • 2007
  • The purpose of this study is to investigate the seismic behavior of reinforced concrete bridge columns using shaking table tests. A computer program, named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), for the analysis of reinforced concrete structures was used. Material nonlinearity is taken into account by comprising tensile, compressive and shear models of cracked concrete and a model of reinforcing steel. Solution of the equations of motion is obtained by numerical integration using Hither-Hughes-Taylor (HMT) algorithm. The proposed numerical method for the seismic behavior of reinforced concrete bridge columns using shaking table tests is verified by comparison with reliable experimental results.