• Title/Summary/Keyword: 진동기초

Search Result 741, Processing Time 0.028 seconds

Shaking Table Test for an Evaluation of the Limit State Capacity of an Anchor Foundation in the case of a Seismic Event (지진시 앵커기초의 한계성능 평가를 위한 진동대 실험)

  • Kim, Min-Kyu;Choi, In-Kil;Kwon, Hyung-O
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.23-31
    • /
    • 2010
  • In this study, a shaking table test was performed for the evaluation of the failure capacity of an anchor foundation system in the case of an aged condition. For the shaking table test, three kinds of specimens were manufactured as follows: 1) a non-damaged anchor; 2) a specimen with cracks running through the anchor; and 3) a specimen with cracks along the expected corn-shape fracture away from the anchor. A dynamic characteristic was determined through a measurement of the frequency response function (FRF), and the seismic capacity was evaluated by using a shaking table test. Failure capacities were calculated using an acceleration response and it was compared with the anchor design code.

압전션트감쇠 기초이론

  • 김재환
    • Journal of KSNVE
    • /
    • v.14 no.2
    • /
    • pp.46-53
    • /
    • 2004
  • 압전션트감쇠란 압전재료를 구조물에 부착시키고 간단한 션트회로를 연결시켜 구조물의 진동에너지를 압전재료에서 전기적 에너지로 변환시킨 후 연결된 회로에서 전기에너지를 열 에너지로 소산시킴으로서 구조물의 진동 및 소음을 저감시키는 방법이다. 이 방법은 공진주파수에서 간단한 회로를 사용하여 효과적으로 진동 및 소음을 저감시킬 수 있으며 구조가 간단하고 가격이 저렴하므로 소음진동의 여러분야에 응용이 가능하다. 본 글에서는 압전션트 감쇠의 원리와 단일모드, 다중모드의 감쇠 기법의 이론을 소개한다.(중략)

A example study on monitoring near field vibration in the rock mass adjacent blast hole (발파공 주변의 인접거리 진동계측 사례연구)

  • Lee, Hyo;Won, Yeon-Ho;Kim, Jin-Soo;Ju, Young-Og
    • Proceedings of the KSEE Conference
    • /
    • 2006.10a
    • /
    • pp.153-166
    • /
    • 2006
  • 종래의 발파진동의 분석은 주로 대상 지장물에 대한 피해한계를 정립시키고자 하는 관점에서 발파공에서 비교적 원거리의 진동특성을 이해하기 위해 수행되어져 왔으나, 최근의 추이는 발파공 주변 암반의 손상의 정도를 평가하고자 하는 관점에서 그 분석영역의 범위가 근거리 진동특성 연구분야로 확대되고 있는 실정이다. 특히, 터널 발파작업시 여굴의 발생, 암반사면의 안정성 검토 등의 목적으로 암반의 손상영역을 평가하는데 있어서, 기초자료로 활용하고자 많은 연구가 이루어지고 있다. 암반손상의 평가를 위한 손상권 예측방법에는 여러 가지가 있으나, 그 중에서 대부분이 발파진동속도에 근거하고 있으며, 평가를 위한 진동의 예측은 기존에는 원거리 진동특성을 이용하여 근거리 진동을 예측하는 방법으로 그 손상의 정도를 평가하였으나, 최근의 추세는 계측기의 발달로 수m 이내의 진동특성의 계측이 가능하게 되었다. 이와 관련하여 국외에서는 수차례의 실험결과가 여러 문헌에서 보고되고 있으나, 실험장비의 선택 및 측정방법의 어려움 등의 연유로 국내에서는 아직까지 실시되지 못하고 있는 상황이다. 따라서, 본 연구에서는 실제 발파공 근접진동(near field vibration) 계측을 실시하고 그 결과를 분석하여 추후 지속적인 근거리 진동측정 방법 및 평가방법에 대한 기초자료를 제공하고자 하였으며, 무엇보다도 어떻게 계측할 것인가 하는 계측방법 및 그 계측결과의 분석방법에 대해 문제점 파악 및 향후 보완점에 대해 비중을 두어 수행하였다.

  • PDF

A Study on the Vibration Characteristics of Elastically Restrained Beams (탄성지지된 보의 진동특성에 관한 연구)

  • 이규섭;조창기;류봉조;윤영식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.116-120
    • /
    • 1995
  • 본 연구의 목적은 탄성 스프링 지지된 외팔보 모델의 고유진동수를 엄밀해, 유한요소법의 근사해, 실험 값을 비교하여 해의 타당성을 검토하고, 진동 특성을 분석함으로서 이러한 보 모델에 대한 유용한 설계 기초자료를 얻는데 있다.

  • PDF

자기변형 기초강좌 (1)

  • Lee, Ho-Cheol
    • Journal of KSNVE
    • /
    • v.21 no.2
    • /
    • pp.29-34
    • /
    • 2011
  • 이번 기초강좌 코너에서는 앞으로 4회 혹은 5회에 걸쳐서 소위 영어로 'magnetostriction' 한국말로는 '자기변형 혹은 자왜현상'(이하 자기변형 현상으로 통일하여 지칭함)이라고 불리는 현상에 대한 연재를 진행할 예정이다. 지능형 물질에 대한 관심이 어느 때보다 높아진 요즘에 독자들의 요구에 부합하는 시의적절한 연재물이 되기를 기대하며 때때로 필자의 근거 없는 사견이 포함되더라도 독자 여러분들의 많은 양해를 부탁드린다.

Development and Shaking Table Tests of a Base Isolator for Controling Subway Train-Induced Vibration of a Steel Building (지하철 진동에 대한 철골건물 기초진동 절연장치의 개발 및 진동대 실험)

  • Kim, Jin-Koo;Song, Young-Hoon;Kwun, Hyong-Oh;Huh, Young
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.789-796
    • /
    • 1997
  • In this study a conventional rubber mount and a new form of base isolator made of steel spring coated with natural and articial rubber were manufactured and tested on a shaking table to investigate the capacity of reducing the vertical vibration of a building induced by subway train. The model structure used in the test is a 1/4 scaled steel structure, and a white noise input and train vibration records were used to check the effectiveness of the isolators. According to the results all three types of isolators turned out to perform effectively in reducing the acceleration and the natural rubber-coated one is ranked best among the isolators. However the vertical displacement of the model is increased due to the instolation of the bearings, and the safty against the lateral load induced by earthquake ground motion should be provided to be able to apply the system to the real buildings.

  • PDF

The Study on the Vibration Characteristic of Electronic Subrack System (전자통신장비 서브랙 진동특성연구)

  • 허남일;김원태;김형섭;한재섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.62-66
    • /
    • 1994
  • 본 연구에서는 실제 사용되고 있는 TDX-10 교환기의 subrack과 보드에 대한 진동 특성과 이 보드가 subrack에 실장되었을 때 진동 특성을 연구하였으며, subrack이 rack에 실장되는 조건을 갖는 진동 시험용 jig를 제작하여 보드와 subrack을 실장한 후 강제 진동시의 진동 전달 특성을 알아보았다. 본 연구의 결과는 내진동 특성이 우수한 전자통신 시스템 설계와 CDMA 이동통신 시스템의 HINA subrack 구조설계와 같은 개발장비 환경시험의 기초 자료로 활용될 수 있을 것이다.

  • PDF

Response of Open-ended Pipe Pile Foundation at Offshore Sites to Seaquake Induced by the Vertical Seismic Excitation of the Seafloor (해저면의 수직 지진 진동에 의해 유발된 해진에 대한 해상 개단 강관 말뚝 기초의 거동)

  • 최용규;남문석
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • During an earthquake, there are three main components of excitation : horizontal excitation of the ground, vertical excitation of the pile due to superstructure feedback produced by vertical excitation of the ground, and the seawater excitation induced by the vertical ground shaking, that is, "the seaquake." These excitations could have effects on the soil plugs in open-ended pie piles installed at offshore sites. In this study, seaquake excitation induced by the vertical ground shaking was simulated by pulsing the water pressure at the seabed. During a seaquake, due to the induced excess porewater pressure and pressure gradients in the soil, the capacity of open-ended pipe piles installed in a simulated sea depth of greate than 220 m was reduced serevely and the soil plugging resistance was degraded by more than 80% The soil plug was failed because of eh upward seepage forces that developed in the soil plug due to excess pore water pressure produced in the bottom of the soil plug during the seaquake, The compressive capacity of ar open-ended pile in a simulated sea depth of less than 220 m was reduced only by about 10% and the soil plug resistance was degraded by less than 5%.s than 5%.

  • PDF

Free Vibrations of Circular Strip Foundations with Variable Breadth (변화폭 원호형 띠기초의 자유진동)

  • Lee, Byong-Koo;Huh, Young;Lee, Jong-Kook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.3
    • /
    • pp.230-235
    • /
    • 2004
  • This paper deals with the free vibration analysis of circular strip foundations with the variable breadth. Taking into account effects of both rotatory inertia and shear deformation, differential equations governing free vibrations of such foundations are derived. The Winkler foundation is chosen as the model of soil foundation. The breadth of strip foundation is assumed to be a linear function. The differential equations are solved numerically to calculate natural frequencies. In numerical examples, the strip foundations with the hinged-hinged, hinged-clamped. clamped-hinged and clamped-clamped end constraints are considered. The parametric studies are conducted and the lowest four frequency parameters are reported in figures as the non-dimensional forms.