• Title/Summary/Keyword: 직선이동

Search Result 426, Processing Time 0.035 seconds

Accuracy Analysis of Velocity and Water Depth Measurement in the Straight Channel using ADCP (ADCP를 이용한 직선 하천의 유속 및 수심 측정 정확도 분석)

  • Kim, Jongmin;Kim, Dongsu;Son, Geunsoo;Kim, Seojun
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.5
    • /
    • pp.367-377
    • /
    • 2015
  • ADCPs have been highlighted so far for measuring steramflow discharge in terms of their high-order of accuracy, relatively low cost and less field operators driven by their easy in-situ operation. While ADCPs become increasingly dominant in hydrometric area, their actual measurement accuracy for velocity and bathymetry measurement has not been sufficiently validated due to the lack of reliable bench-mark data, and subsequently there are still many uncertain aspects for using ADCPs in the field. This research aimed at analyzing inter-comparison results between ADCP measurements with respect to the detailed ADV measurement in a specified field environment. Overall, 184 ADV points were collected for densely designed grids for the given cross-section that has 6 m of width, 1 m of depth, and 0.7 m/s of averaged mean flow velocity. Concurrently, ADCP fixed-points measurements were conducted for each 0.2m and 0.02m of horizontal and vertical spacing respectively. The inter-comparison results indicated that ADCP matched ADV velocity very accurately for 0.4~0.8 of relative depth (y/h), but noticeable deviation occurred between them in near surface and bottom region. For evaluating the capacity of measuring bathymetry of ADCPs, bottom tracking bathymetry based on oblique beams showed better performance than vertical beam approach, and similar results were shown for fixed and moving-boat method as well. Error analysis for velocity and bathymetry measurements of ADCP can be potentially able to be utilized for the more detailed uncertainty analysis of the ADCP discharge measurement.

Numerical Simulation for Behavior of Debris Flow according to the Variances of Slope Angle (비탈면 경사 변화에 따른 토석류 거동의 수치모의)

  • Kim, Sungduk;Yoon, Ilro;Oh, Sewook;Lee, Hojin;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.6
    • /
    • pp.59-66
    • /
    • 2012
  • The purpose of this study is to estimate the behavior and the mechanism of debris flow on the slope, which has specially various gradient plane. The numerical simulation was performed by using the Finite Differential Element method (FDM) based on the equation for the mass conservation and momentum conservation. The mechanism of flow type for debris flow is divided into three flow types which are stony debris flow, immature debris flow, and turbulent water flow, respectively. First, flow discharge, water flow depth, sediment volume concentration was investigated by variable input of flow discharge at the straight slope angle and two step inclined plane. As the input of flow discharge was decrease, flow discharge and water flow depth was increased, after the first coming debris flow only reached at the downstream. As the input of flow discharge was increased, the curve of flow discharge and flow depth was highly fluctuated. As the results of RMS ratio, the flow discharge and flow depth was lower two step slope angle than the straight slope angle. Second, the behavior of debris flow was investigated by the four cases of gradient degree at the downstream of slope angle. The band width of flow discharge and flow depth for $14^{\circ}$ between $16^{\circ}$ was higher than other gradient degree, and fluctuation curve was continuously high after 10 seconds.

The Effect of Electrode Pattern on the Humidity-sensing Properties of the Resistive Humidity Sensor Based on All-printing Process (인쇄공정으로 제조된 저항형 습도센서의 감습특성에 대한 전극패턴의 영향 연구)

  • Ahn, Hee-Yong;Gong, Myoung-Seon
    • Polymer(Korea)
    • /
    • v.36 no.2
    • /
    • pp.169-176
    • /
    • 2012
  • Based on our experience in developing resistive humidity sensor, interdigital gold electrodes with different fingers and gaps have been fabricated on a glass epoxy (GE) substrate using screen printing techniques. The basic structure of the electrode consisted of a 3-, 4- and 5-fingers with gaps of 310 and 460 ${\mu}m$. Gold electrode/GE was prepared by first printing silver nanopaste, followed by consecutive electroless plating of Cu, Ni and then Au. Copolymer of [2-(methacryloyloxy)ethyl] dimethyl benzyl ammonium chloride (MDBAC) and methyl methacrylate (MMA) was used as a humidity-sensing polyelectrolyte, which was fabricated by a screen printing method on the Au electrode/GE substrate. The flexible humidity sensor showed acceptable linearity between logarithmic impedance and relative humidity in the range of 20-95%RH, low hysteresis of 1.5%RH, good response and recovery time of 75 sec at 1 V, 1 kHz, and $25^{\circ}C$. Electrode construction had a significant influence on the humidity-sensing characteristics of polymeric humidity sensors. The activation energy between electrode and ion conducting polyelectrolyte plays an important role in explaining the differences of humidity sensing characteristics such as temperature dependence, sensitivity, linearity and hysteresis.

Analytical Method Development of (-)-Epicatechin gallate in Penthorum chinense Pursh Extract using HPLC (HPLC를 이용한 낙지다리 추출물의 (-)-­Epicatechin gallate 분석법 개발)

  • Kwon, Jin Gwan;Jung, Yeon Woo;Seo, Changon;Hong, Seong Su;Choi, Chun Whan;Lee, Ji Eun;Shin, Hyun Tak;Jung, Su Young;Kim, Jin Kyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.1
    • /
    • pp.87-93
    • /
    • 2019
  • This study attempted to eatablish a High Performance Liquid Chromatography (HPLC) analysis method for the determination of (-)-epicatechin gallate as a part of the quality control for the development of functional cosmetic materials from Penthorum chinense Pursh. HPLC was performed on a Unison $US-C_{18}$ column ($4.6{\times}250mm$, $5{\mu}m$) with a gradient elution of 0.05% (v/v) trifluoroacetic acid (TFA) and methyl alcohol at a flow rate of 1.0 mL/min at $30^{\circ}C$. The analyte was detected at 280 nm. The HPLC method was performed in accordance with the International Conference on Harmonization (ICH) guideline (version 4, 2005) of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limits of detection and quantitation were 0.11 and 0.33 mg/mL, respectively. Calibration curves showed good linearity ($r^2$ > 0.9999), and the precision of analysis was satisfied (less than 0.6%). Recoveries of quantified compounds ranged from 99.51 to 101.92%. This result indicates that the established HPLC method is very useful for the determination of marker compound in P. chinense Pursh extracts.

Analysis of Cadaverine and Its Worker Honeybee Venom Content (Apis mellifera L.) (꿀벌(Apis mellifera L.) 일벌독의 생체아민 cadaverine 함량 및 분석법)

  • Choi, Hong Min;Kim, Hyo Young;Kim, Se Gun;Han, Sang Mi
    • Journal of Life Science
    • /
    • v.31 no.2
    • /
    • pp.144-148
    • /
    • 2021
  • This study aimed to analyze the content and composition of a biological amine, cadaverine, isolated from the venom of worker honeybees (Apis mellifera L.). This biological amine―which has diverse functionality, such as anti-inflammatory and antibacterial effects―has not been previously reported in bee venom. An assay completed in 13 minutes was developed for the cadaverine present in the bee venom using an ultra-performance liquid chromatograph and a Halo C18 column with acetonitrile and water as the mobile phase. The specificity, accuracy, and precision of the assay were verified, and the assay was validated. The linearity for cadaverine in the bee venom was R2=0.99 or above, indicating a moderate level. The limit of detection and limit of quantification were both 0.3 ㎍/ml, and the rate of recovery was 97.6%-99.1%. The relative standard deviation (RSD) of the intra-day precision and inter-day precision for cadaverine was 0.25%-0.44% and 0.25%-1.25%, respectively, with an RSD that fell within 5% indicating excellent precision. Through this novel assay, it was found that the mean content of cadaverine was 1.10±0.05 mg/g. Our results indicated that the linearity, limit of detection, limit of quantification, and rate of recovery of the cadaverine assay were of a satisfactory level, and the cadaverine content of the bee venom was ably determined. This study provides basic data on cadaverine in bee venom, which will prove useful in further studies on the bioactivity of this component.

Analytical Method Development of Isoscoparin in Silene seoulensis Extract Using HPLC (HPLC 를 이용한 가는장구채 추출물의 Isoscoparin 분석법 개발)

  • Kwon, Jin Gwan;Seo, Changon;Jung, Yeon Woo;Choi, Yongmun;Shin, Hyun Tak;Jung, Su Young;Choi, Jeong June;Kim, Jin Kyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.1
    • /
    • pp.57-63
    • /
    • 2021
  • In this study, isoscoparin was selected as an indicator component to develop Silene seoulensis extract as a functional cosmetic material, and we developed an analysis method using high performance liquid chromatography (HPLC) for quality control. HPLC was performed on a Unison US-C18 with a gradient elution of 0.05% (v/v) trifluoroacetic acid (TFA) and methanol at a flow rate of 1.0 mL/min at 35 ℃, and the detection wavelength was 330 nm. The HPLC method was performed in accordance with the international conference on harmonization (ICH) guideline (version 4, 2005) of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limits of detection and quantitation were 0.02 and 0.07 mg/mL respectively. Calibration curves showed good linearity (R2 > 0.99988), and the precision of analysis was satisfied (less than 0.46%). In addition, the recovery rate was in the range of 99.10 to 101.61%, it was shown to be accurate. This result indicated that the established HPLC method is very useful for the determination of marker compounds in Silene seoulensis extracts.

Lunar Exploration Employing a Quadruped Robot on the Fault of the Rupes Recta for Investigating the Geological Formation History of the Mare Nubium (4족 보행 로봇을 활용한 달의 직선절벽(Rupes Recta)의 단층면 탐사를 통한 구름의 바다(Mare Nubium) 지역의 지질학적 형성 연구)

  • Hong, Ik-Seon;Yi, Yu;Ju, Gwanghyeok
    • Journal of Space Technology and Applications
    • /
    • v.1 no.1
    • /
    • pp.64-75
    • /
    • 2021
  • On the moon as well as the earth, one of the easiest ways to understand geological formation history of any region is to observe the stratigraphy if it is available, the order in which the strata build up. By analyzing stratigraphy, it is possible to infer what geological events have occurred in the past. Mare Nubium also has an unique normal fault called Rupes Recta that shows stratigraphy. However, a rover moving with wheels is incompetent to explore the cliff since the Rupes Recta has an inclination of 10° - 30°. Therefore, a quadruped walking robot must be employed for stable expedition. To exploration a fault with a four-legged walking robot, it is necessary to design an expedition route by taking account of whether the stratigraphy is well displayed, whether the slope of the terrain is moderate, and whether there are obstacles and rough texture in the terrain based on the remote sensing data from the previous lunar missions. For the payloads required for fault surface exploration we propose an optical camera to grasp the actual appearance, a spectrometer to analyze the composition, and a drill to obtain samples that are not exposed outward.

Rapid and simultaneous determination of metabolites of organic solvents in human urine by high-performance liquid chromatography using a monolithic column (Monolithic 칼럼을 이용한 뇨 중 유기용매 대사체의 신속한 HPLC 동시 분석)

  • Han, Sang Beom;Lee, Sang-Ju;Lee, Cheol-Woo;Yoon, Seo Hyun;Joung, Sun Kyung;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.433-440
    • /
    • 2006
  • A HPLC/UV method was developed and validated for the rapid and simultaneous determination of urinary metabolites of organic solvents, mandelic acid, hippuric acid, phenylglyoxylic acid, ortho-, meta- and para-methylhippuric acid, using a monolithic column. The mobile phase was composed of tetrabutylammonium bromide as ion-pairing reagent with a flow rate of 2.4 mL/min. The total run time was less than 2.5 min for all six analytes. Good linearities were obtained for all the metabolites with correlation coefficients above 0.9993. Intra-day precision, accuracy and inter-day precision was 0.01~7.32%, 83.9~116.3% and 0.01~7.16%, respectively. The method was validated and confirmed by quantification of the quality assurance samples of Industrial Safety and Health Research Institute, Korea Occupational Safety and Health Agency.

Generation Method of Expression Space for Realtime Facial Expression Control of 3D Avatar (3차원 아바타의 실시간 얼굴표정제어를 위한 표정공간의 생성방법)

  • Kim Sung-Ho
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.06a
    • /
    • pp.109-111
    • /
    • 2006
  • 본 논문은 애니메이터로 하여금 얼굴 표정들의 공간으로부터 일련의 표정을 선택하게 함으로써 3차원 아바타의 표정을 실시간적으로 제어할 수 있도록 하기 위한 표정공간의 생성방법에 관하여 기술한다. 본 시스템에서는 약 2400여개의 얼굴 표정 프레임을 이용하여 표정공간을 구성하였다. 본 기법에서는 한 표정을 표시하는 상태표현으로 얼굴특징 점들 간의 상호거리를 표시하는 거리행렬을 사용한다. 이 거리행렬의 집합을 표정공간으로 한다. 그러나 이 표정공간은 한 표정이 다른 표정까지 이동할 때 두 표정간의 직선경로를 통해 이동할 수 있는 그런 공간이 아니다. 본 기법에서는 한 표정에서 다른 표정까지 거쳐 갈 수 있는 경로를 캡쳐된 표정 데이터로부터 근사적으로 유추한다. 우선, 각 표정상태를 표현하는 거리행렬간의 거리가 일정 값 이하인 경우 두 표정을 인접해 있다고 간주한다. 임의의 두 표정 상태가 일련의 인접표정들의 집합으로 연결되어 있으면 두 표정간에 경로가 존재한다고 간주한다. 한 표정에서 다른 표정으로 변화할 때 두 표정간의 최단경로를 통해 이동한다고 가정한다. 두 표정간의 최단거리를 구하기 위해 다이내믹 프로그래밍 기법을 이용한다. 이 거리행렬의 집합인 표정공간은 다차원 공간이다. 3차원 아바타의 얼굴 표정 제어는 애니메이터들이 표정공간을 항해할 때 실시간적으로 수행된다. 이를 도와주기 위해 표정공간을 차원 스케일링 기법을 이용하여 2차원 공간으로 가시화하였고, 애니메이터들로 하여금 본 시스템을 사용하여 실시간 표정 제어를 수행하게 했는데, 본 논문은 그 결과를 평가한다.참여하는 빈들 간의 관계를 분석하여 워크플로우에 대한 성능 측정이 가능하도록 한다. 또한 제안된 메트릭을 통하여 EJB 어플리케이션의 성능 향상을 도모할 수 있도록 한다.로 표면 위로 자라났고, 부종은 창상 밑 조직까지 감소하였으며, 육아조직은 교원질 섬유로 대체되었다. 창상 유발 21일 후, 다른 창상에 비해, HG 처치창은 유의적으로 창상 표면이 거의 재생성 상피로 덮였으며, 육아조직은 창상 유발 14일 후와 비교해서 유의적으로 교원질 섬유로 대체되었다. 위의 모든 결과에서 보듯이, 개에서 전층피부 창상의 처치 시 HG의 사용은 HC와 생리 식염수에 비해 창상치유 복구기의 치유 속도를 촉진하는 것으로 사료된다.시범학교의 자녀를 들 부모들은 환경관련문제에 대한 의식 및 환경관련 제품에 대한 구매행동의 변화가 두드러지게 나타났다.EX>$d^{2+}$ + SA처리구는 두 화합물의 이중 효과에 의해 전반적인 생리 활성을 억제하여, 결국에는 식물의 고사를 유도하는 것으로 사료된다.목에 대한 보안'이 가장 중요한 것으로 나타났다. 본 연구에서는 솔루션 선정요인에 관한 중요도를 e-마켓플레이스의 유형과 산업 별로 평가해보았는데, 여기에서 밝혀진 중요도를 통해 e 마켓플레이스를 구축하고 자 하는 기업은 솔루션을 자체 개발하거나 구입할 때 올바른 의사결정을 할 수 있다. 그리고 솔루션을 제공하려는 기업측면에서는 e-마켓플레이스를 구축하고자 하는 기업에게 유형과 산업별로 적절한 솔루션을 제공할 수 있다.순환이 뇌대사 및 수술 후 신경학적 결과에 보다 유익한 효과를 제공해 줄 수 있음

  • PDF

Retention Behavior and Separation of Phenol Derivatives through Cyclodextrin Complexes in Reversed-Phase Liquid Chromatography (역상 액체 크로마토그래피에서 씨클로덱스트린 착물을 이용한 페놀유도체들의 머무름 거동 및 분리)

  • Moon, Young-Ja;Kang, Sam-Woo
    • Analytical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.179-188
    • /
    • 1998
  • The capacity factor of fifteen phenol derivatives was determined with respect to the concentration of ${\alpha}$- or ${\beta}$-cyclodextrin [CD], the type as well as the content of organic solvent in the mobile phase, and the temperature. The effect of the inclusion complex formation between solutes and ${\alpha}$- or ${\beta}$-cyclodextrin on their retention and selectivity has been investigated. The inclusion effect of ${\beta}$-cyclodextrin was the most effective in aqueous methanol, whereas only a poor effect was observed in aqueous tetrahydrofuran and aqueous acetonitrile. A plot of the reciprocal of the capacity factor against $[CD]_T$ gives a straight line and the dissociation constant, $K_D$ of the inclusion complex can be calculated from the slope. It was possible to estimate the $k_D$ values in 100% water from a linear plot of $pK_D$ vs. water content in the solution by extrapolation. The separation factor, ${\alpha}$, of two compounds has been found to be affected not only by the $[CD]_T$ but also by their $K_D$ values. Under optimum conditions, some mixtures of phenol derivatives were able to separate successfully.

  • PDF