• Title/Summary/Keyword: 지하철 화재

Search Result 179, Processing Time 0.037 seconds

Visualization of Smoke Flow in the Subway Fire (지하철 화재발생시 역사내 화재연기 거동 가시화 연구)

  • Choi Chang Jin;Jung Hae Gon;Kim Sang Moon;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.64-68
    • /
    • 2005
  • In this study, the smoke flows of the inner subway station were visualized through a numerical analysis and visualization experiment in the subway fire. A transparent acrylic model was designed and installed as 1:25th scale-down as the actual subway station by using geometrical similarity The properties of subway fire were reconstructed according to Densimetric Froude Similarity. The 47 to 53 ratio of the mixed air and Helium was inputted in the inner acrylic model to describe 1MW fire intensity with reference to the experiment paper. For the same time, the fire smoke from a smoke generator was inputted in the inner acrylic model with the mixture. At this time, the buoyancy effect of Helium gas went up the smoke to the acrylic model. When the sheet beam of Ar-lon laser was given out to the top and stair of subway model, the digital camcorder took the images of the scattered cluster of smoke particles when applying the smoke management system and PSD.

  • PDF

A Study on method to construct system for u-Safe fire management support (u-Safe 소방대응지원 시스템 구축방안에 관한 연구)

  • Jeon, Jai-Pil;Yang, Hae-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1201-1209
    • /
    • 2008
  • In Seoul, there are lots of skyscrapers that have above 60 stories and buildings that have more than 8 basement levels, as well as massive distribution complex region which is connected to subways, departments, malls, hotels, and exhibition halls. When an accident, such as fire and explosion, happens in these areas or structures, if we can't find where fire-fighters are, who go into the building to suppress the fire, we couldn't be sure of their safety as well as effective command. Actually, it may cause much more damage itself and restrict either fire suppression or lifesaving. To protect people's life and properties as much as possible, this study will show the method to construct system of disaster-management supports with effective operation of fire force and scientific fire strategy in the scene by using Ubiquitous technique to enormous disasters.

The Actual Condition of the Arson and Countermeasure (방화범죄의 실태와 대책방안)

  • Jung Gi-Sung
    • Fire Science and Engineering
    • /
    • v.19 no.2 s.58
    • /
    • pp.93-104
    • /
    • 2005
  • Nowadays, the arson is not common interest happening. the arson has been handled with a crime of violence along with murder, robbery and rape. because of being detrimental to the public clam. but the arson a has not been made award of a serious social problem. There is a rise in the control possibility according to a level of national concern. we have known that the last fire accident of the Deagu underground It took a heavy toll of lives and the property due to our no interest in arson. The government and regional self governing community have fully aware of the serious of the arson so that we can make arrangement for overall measures. The government should not only make up for legislation and systematize to correct a defect but also there is uniting the countermeasure system of the organs. The government establish particular research institution of the arson to consider a useful countermeasure. The investigation authorities should develop the investigation technique to arrest an arsonist. The relevant post strengthen the public relation to bring up a private organization of fire prevention in order to prevent the arson to try the government best.

How Phenolic Composites were chosen - In Case of England (7) (페놀 컴포지트 실용화의 길 - 영국의 경우 (CASE STUDY 7))

  • Nomaguchi Kanemasa;Forsdyke Ken L.
    • Composites Research
    • /
    • v.18 no.1
    • /
    • pp.55-66
    • /
    • 2005
  • Beside fire resistance, for Phenolic Composites(here-in-after PCs), in actual, moisture resistance are also needed when they are applied to components in wet uses such as in Naval vessels and in off-shore operations where direct water contact may be expected. PCs have so-called 'Micro-porous' when they are made by normal GRP manufacturing techniques, which causes much larger amounts of water absorption in them to higher level of around $7\%$. So, this figure, which indicate impending disaster in a polyester matrix laminate, has made some specifiers suspicious of the effect of the water on mechanical performance of PC in 'wet' service. To solve this problem, a large amount work has been carried out by workers in UK and US. This paper is an attempt to explain that the effect of the high water absorption of PCs is not the disaster that some 'prophets' may foretell. Let's open our next door fur better society much safetyfied by our own efforts with PCs. like in UK.

GIS-based Fire Evacuation Simulation using CA Model (CA 모델을 이용한 GIS 기반 화재 대피 시뮬레이션)

  • Park, In-Hye;Jun, Chul-Min;Lee, Ji-Yeong
    • Spatial Information Research
    • /
    • v.16 no.2
    • /
    • pp.157-171
    • /
    • 2008
  • With emerging technologies on wireless networks and mobile computing environment, a number of researches have been carried out for ubiquitous computing. An important functional requirement of ubiquitous computing is to handle location data with ease. With the increase of accidents in large complex buildings. move attention is being paid to indoor spaces and evacuation. However, most currently used evacuation-related applications are simulation based on hypothetical data. Also, since they use non-georeferenced CAD data, it is not easy to integrate them with indoor positioning devices. With the recent progress of indoor positioning systems, the simulators can be enhanced to real-time evacuation systems. As a preliminary stage to make such systems possible, this study proposes using a georeferenced data and evacuation simulation. This study used GIS data and Cellular Automata theory an the algorithm for the movement of the evacuee.

  • PDF

동물약계

  • 한국동물약품협회
    • 동물약계
    • /
    • no.88
    • /
    • pp.4-7
    • /
    • 2003
  • [ $\cdot$ ]긴급 이사회 개최 $\cdot$제1차 가축질병중앙예찰 협의회 참석 $\cdot$동물약사감시 행정처분 결과 홍보 $\cdot$제조$\cdot$수입관리자 불법 운영 근절 $\cdot$협회 제1차 이사회 개최 $\cdot$협회 제11차 정기총회 개최 $\cdot$구제역 발생국 여행시 유의사항 안내 $\cdot$농협중앙회 소독약품 긴급구매 입찰 실시 $\cdot$동물용의약품 GMP 확대 지정 추진 $\cdot$동물약사 업무 관련 설명회 개최 $\cdot$돼지콜레라 예방약 긴급 생산 협의회 개최 $\cdot$동물약사 제도개선을 위한 협의회 개최 $\cdot$동물약품 GMP 실무반 교육 실시 $\cdot$소독약품 계량용기 공급 $\cdot$동물약품 PL 단체보험 가입 현황 $\cdot$대구 지하철 화재 사고 위로금 기탁 현황

  • PDF

A study for risk analysis and disater prevention of the passengers when traincar fire on PSD Installed subway (지하철 승강장안전문 설치에 따른 열차 화재시 승객 위험성평가와 방재방안 연구)

  • Hwang, Cheol-Seung;Kim, Dong-Sung;Lee, Sang-Gon;Cho, Won-Cheol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.555-560
    • /
    • 2007
  • This paper focused on the ways of disater prevention and risk analysis of the passengers setting up the hypothesis when urban rapid transit broke out fire in subway tunnel which is PSD(Platform Screen Door) installed environment. compared the flud dynamic changes and evacuation specifications whether PSD being installed or not, tried to search the effective ways for sustaining passengers safety.

  • PDF

Numerical Prediction of the Heat and Smoke Propagations for a Passenger Train Fire in an Underground Subway Tunnel for Different Extraction Flowrate (지하철 터널 내 운행 중 객차에서 화재발생시 제연풍량에 따른 열 및 연기 확산 예측 연구)

  • Chang, Hee-Chul;Yoon, Kyung-Beom;Park, Lee-Jin;Kim, Tae-Kuk;Park, Won-Hee;Kim, Dong-Hyeon
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.250-253
    • /
    • 2007
  • The purpose of this research is focussed on the numerical predictions of the heat and smoke propagations for a passenger train fire in an underground subway tunnel for different air supply and extraction flowrates. The analysis is performed for one of the stations on subway line #5 in Seoul under the emergency operation mode for different air supply and extraction flowrates. Five different the air supply and extraction flowrates are considered for the numerical analyses. The numerical results show that the air supply and extraction flowrates affect the smoke control performance significantly by improving the smoke removal performance for the balanced control of air supply and smoke extraction and for the unbalanced control with lager smoke extraction than air supply.

  • PDF

A study of evacuation time in a subway carriage fire (지하철 객차 화재발생시 피난 시간에 대한 연구)

  • Kim, Seong-Ryul;Roh, Jae-Seong;Ro, Kyoung-Chul;Ryou, Hong-Sun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1313-1318
    • /
    • 2007
  • Recently, the terror frequently has taken place for unspecified individuals as modern society is complicated. Especially, in case of a subway carriage fire as Daegu subway fire, because smoke spread path usually coincide with passenger's evacuation path, it will reduce visibility and can cause fatalities by asphyxiation. This study performs not only fire simulation with CFAST V6 but also evacuation simulation with EXODUS V4 for the purpose of taking measures for passengers's life safety in subway fire. As a result of evacuation simulation without fire, evacuation times are 36 s for EXODUS V4 and simple hand calculation, and when fire is occurred fire, 101 persons evacuated in 32 s. Therefore, a countermeasure of evacuation in subway carriage fire is required to repression of fire and emergency exit.

  • PDF

Quantitative Fire Risk Assesment for the Subway Platform Types (지하철 승강장 형식에 따른 정량적 화재 위험성 평가)

  • Rie, Dong-Ho;Kim, Ha-Young
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.1-6
    • /
    • 2006
  • Subway platform is divided into Side-platform type and Center-platform type. In this study does quantitative fire risk assesment of subway platform types in numerical analysis by using CFD model. From the result of this study, 1) All exhaust mode was low-end result it seems most fire risk at Side-platform station. 2) All exhaust mode was low-end result it seems most fire risk at Center-Platform station. 3) When comparing same type exhaust mode of Side-platform and Center-platform that last thing was visible $9.1{\sim}72.34%$ low-end fire risk. Center-platform is more opera-tive than Side-platform that reduce fire risk when that was same dimension and external environment. Designer look upon a fire characteristic of subway platform types when he make smoke control air volume and platform area design.