• Title/Summary/Keyword: 지지와 저항

Search Result 314, Processing Time 0.027 seconds

Effect of Support on the Performance and Electrochemical Durability of Membrane in PEMFC (PEMFC의 고분자막에서 지지체가 고분자전해질 막 성능 및 전기화학적 내구성에 미치는 영향)

  • Oh, Sohyung;Lim, Dae Hyun;Lee, Daewoong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.524-529
    • /
    • 2020
  • To increase the mechanical durability of the proton exchange membrane fuel cells, a reinforced membrane in which a support is placed in the polymer membrane is used. The support mainly uses e-PTFE, which is hydrophobic and does not transfer ions, which may cause performance degradation. In this study, we investigated the effect of e-PTFE support on PEMFC performance and electrochemical durability. In this study, the reinforced membrane with the support was compared with the single membrane (non-reinforced membrane). Due to the hydrophobicity of the support, the water diffusion coefficient of the reinforced membrane was lower than that of the single membrane. The reinforced membrane had a lower water diffusion coefficient, resulting in higher HFR, which is the membrane migration resistance of ions, than that of a single membrane. Due to the low hydrogen permeability of the support, the OCV of the reinforced membrane was higher than that of the single membrane. The support was shown to reduce the hydrogen permeability, thereby reducing the rate of radical generation, thereby improving the electrochemical durability of the reinforced membrane.

Load-Bearing Capacity of Subsea Pipeline with Variation of Sea Water Depth and Buried Depth (수심과 퇴적 깊이 변화에 따른 해저배관의 하중지지능력 평가)

  • Baek, Jong-Hyun;Kim, Young-Pyo;Kim, Woo-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1131-1137
    • /
    • 2012
  • Subsea pipelines have been operated with buried depths of 1.2-4m underneath the seabed to prevent buoyancy and external impacts. Therefore, they have to show resistance to both the soil load and the hydrostatic pressure. In this study, the structural integrity of a subsea pipeline subjected to soil load and hydrostatic pressure was evaluated by using FE analyses. A parametric study showed that the internal pressure increased the plastic collapse depth by increasing the resistance to plastic collapse. The hoop stress increased with an increase in the buried depth for the same water depth; however, the hoop stress decreased with an increase in the water depth for the same buried depth.

Power Generating Characteristics and Long Term Stability of the Anode Supporting Type SOFC (음극지지형 SOFC 단전지의 출력특성 및 장기 안정성)

  • 이종호;김구대;손용배;이해원;김상우;송휴섭;김긍호
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.9
    • /
    • pp.847-855
    • /
    • 2000
  • 80$0^{\circ}C$에서 작동하는 중온형 SOFC(Solid Oxide Fuel Cell) 단전지의 제조공정을 확립하고 그 출력특성을 평가하였다. 중온형 SOFC에서 문제가 되는 전해질 성분에 의한 출력 감소를 최소화하기 위해 음극기판 위에 7-15$\mu\textrm{m}$ 두께의 얇은 YSZ막을 입히는 음극지지형 SOFC를 구성하였다. 산화, 환원 반응이 일어나는 전극에서는 전극반응에 필요한 유효면적을 최대화하여 분극 저항을 줄일 수 있도록 음극으로는 Ni-YSZ 복합체를, 양극으로는 LSM-YSZ 복합체를 사용하였다. 출력특성 평가를 위한 단전지 홀더는 Inconnel을 가공하여 사용하였으며 80$0^{\circ}C$에서 최적의 밀봉효과를 나타낼 유리밀봉재를 개발하여 사용하였다. 제조한 단전지의 단면적은 5$\times$5$\textrm{cm}^2$, 10$\times$10$\textrm{cm}^2$ 두 종류였으며 운전 시험결과 5$\times$5 단전지의 경우는 최고 0.2W/$\textrm{cm}^2$, 10$\times$10 단전지의 경우는 0.12W/$\textrm{cm}^2$ 정도의 출력밀도를 나타내었다. 단전지의 출력 및 장기 안정성은 전극구조의 변화 및 단전지 홀더의 산화에 따른 접촉 저항 변화에 크게 영향을 받는 것으로 나타났으며 운전중의 연료공급 및 작동온도 변화 등에 의한 영향도 큰 것으로 나타났다.

  • PDF

Comparison of Safety Margin of Shallow Foundation on Weathered Soil Layer According to Design Methods (설계법에 따른 풍화토 지반 얕은기초의 안전여유 비교)

  • Kim, Donggun;Hwang, Huiseok;Yoo, Namjae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.12
    • /
    • pp.55-64
    • /
    • 2016
  • In this paper bearing capacity and safety margin of shallow foundation on weathered soil ground against shear failure by using current design method of allowable stress design (ASD), load resistance factor design (LRFD) based on reliability analysis and partial safety factor design (PSFD) in Eurocode were estimated and compared to each other. Results of the plate loading test used in construction and design were collected and analysis of probability statistics on soil parameters affecting the bearing capacity of shallow foundation was performed to quantify the uncertainty of them and to investigate the resistance bias factor and covalence of ultimate bearing capacity. For the typical sections of shallow foundation in domestic field as examples, reliability index was obtained by reliability analysis (FORM) and the sensitivity analysis on soil parameters of probability variables was performed to investigate the effect of probability variable on shear failure. From stability analysis for these sections by ASD, LRFD with the target reiability index corresponding to the safety factor used in ASD and PSDF, safety margins were estimated respectively and compared.

Experimental Analysis of Fretting Wear Behaviors in Elastic Deformable Contacts (탄성변형 접촉에서 프레팅 마멸거동의 실험적 분석)

  • Lee, Young-Ho;Kim, Hyung-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.49-54
    • /
    • 2010
  • Fretting wear behavior under elastic deformable contacts was experimentally examined by using a simulated dual cooled fuel rod and its supporting structure. As this fuel rod has larger outer diameter than the typical solid rod to accommodate sufficient internal flow, new supporting structure geometries should be designed and their reliabilities (i.e. vibration characteristics, fretting wear resistance, etc.) are also examined with both analytical and experimental methods. In this study, the supporting structure characteristics and fretting wear behaviors are analyzed and examined by using one of the supporting structure candidates which has an embossing shape. The supporting structure characteristics were examined by using a specially designed test rig and their results were compared with that of analytical method. Based on the test results, the relationship between the supporting structure characteristics and their fretting wear behaviors was discussed in detail.

Evaluation on Degree of Interference Based on Installation Characteristics of Transverse Members Installed in Steel Strip Reinforcement (띠형 강보강재에 설치된 수동저항부재의 설치 특성에 따른 상호간섭계수 평가)

  • Jung, Sunggyu;Hong, Kikwon;Han, Jung-Geun;Lee, Kwang-Wu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.3
    • /
    • pp.11-19
    • /
    • 2014
  • This paper describes interference effect analysis of transverse member based on large-scale pullout test results of steel strip reinforcement with '${\sqcap}$' type transverse member. The maximum passive resistance has a difference according to the installed location of transverse member, and the total pullout resistance is increased, when transverse member was closed to the wall facing. The degree of interference confirmed that the install location of transverse member cannot reflect the pullout force differential, if S/B is equal. However, The interference factor based on maximum passive resistance reflected the differential of maximum passive resistance and install location of transverse member.

A Study on Essential Concepts, Tools, Techniques and Methods of Stock Market Trading: A Guide to Traders and Investors (주식 거래의 필수 개념, 도구, 기법 및 방법에 관한 연구: 거래자와 투자자를 위한 안내서)

  • Sukhendu Mohan Patnaik;Debahuti Mishra
    • Advanced Industrial SCIence
    • /
    • v.2 no.1
    • /
    • pp.21-38
    • /
    • 2023
  • An attempt has been made in this article to discuss the fundamentals of technical analysis of the stock market. A retail investor or trader may not have the wherewithal to source that kind of information. Technical analysis requires a candlestick chart only. Most of the brokers in India provide charting solutions as well. Studying the price action of a security or commodity or Forex generally indicates a price pattern. Prices react at certain levels and widely known as support and resistance levels. Since whatever is happening with the price of the security is considered to be a part of a pattern or cycle which has already played out sometime in the past, these studies help a keen technical analyst to identify with certain probability, the future movement of the price. Study of the candlestick patterns, price action, volumes and indicators offer the opportunities to identify a high probability trade with probable target and a stop loss. A trader or investor can take high probability trade or position and control only her losses.

Constructing Database and Probabilistic Analysis for Ultimate Bearing Capacity of Aggregate Pier (쇄석다짐말뚝의 극한지지력 데이터베이스 구축 및 통계학적 분석)

  • Park, Joon-Mo;Kim, Bum-Joo;Jang, Yeon-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.8
    • /
    • pp.25-37
    • /
    • 2014
  • In load and resistance factor design (LRFD) method, resistance factors are typically calibrated using resistance bias factors obtained from either only the data within ${\pm}2{\sigma}$ or the data except the tail values of an assumed probability distribution to increase the reliability of the database. However, the data selection approach has a shortcoming that any low-quality data inadvertently included in the database may not be removed. In this study, a data quality evaluation method, developed based on the quality of static load test results, the engineering characteristics of in-situ soil, and the dimension of aggregate piers, is proposed for use in constructing database. For the evaluation of the method, a total 65 static load test results collected from various literatures, including static load test reports, were analyzed. Depending on the quality of the database, the comparison between bias factors, coefficients of variation, and resistance factors showed that uncertainty in estimating bias factors can be reduced by using the proposed data quality evaluation method when constructing database.

Geophysical exploration for the Site Charcteristics of Iljumun Gate in Hwanseongsa Temple (지구물리탐사를 이용한 경산시 환성사 일주문 지반조사)

  • Kim, Ki-Hyun;Suh, Man-Cheol
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.131-136
    • /
    • 2008
  • We performed a non-destructive geophysical survey such as an elastic wave survey, electric specific resistance survey, plate loading test, etc. in order to grasp the structure and status of the ground around the pillar gate and to provide the directions and design data for preservation and maintenance during reconstruction. The result of electric specific resistance survey shows 50-1300 ohm-m range of general electric specific resistance distribution. Besides, the positions around 1m south of stone pillars, between stone pillar No.3 and 4, and 1m north of stone pillar No.2 and 3 show abnormality of relatively lower electric specific resistance than their surroundings. The abnormality of low electric specific resistance appearing between stone pillar No.3 and 4 shows consistency with the abnormal section appearing from the result of elastic wave reflection survey. The result of a plate loading test shows that allowable bearing force is over $10.70tf/m^2$, and the settlement amount at this time was calculated as 19.635mm. The design load during reconstruction of pillar gates was calculated as $16.37t/m^2$ by applying assumption values, which is far more than the allowable bearing force, so it is judged that a measure to strengthen the foundation ground is necessary.

  • PDF