• Title/Summary/Keyword: 증축(增築)

Search Result 180, Processing Time 0.021 seconds

A Study on Vitalizing Plans of Extension Remodeling for Apartment Housings (공동주택 증축 리모델링 활성화 방안에 관한 연구)

  • Cho, Jae-Yong;Lee, Kuen-Woo;Yoo, Hyun-Seok;Kim, Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.4
    • /
    • pp.33-47
    • /
    • 2012
  • 548 thousand apartment houses of Seoul has been used over 15 years and remodeling is available. It is 42% of the overall apartment houses currently and it is assumed to increase to 800 thousand in 2015. The maintenance work is divided to reconstruction and remodeling. Due to the regulations of the government, expansion remodelling has been the most considered alternative. However, 75% of the extension remodelling, yet, are in the preliminary phases. Thus, this study suggests factors hampering the vitalization of extension remodelling and solutions for each factor by means of Delphi analysis method.

The Optimal Isolation Period of Vertically Story-added Remodeling Apartment Building with Seismic Isolation System (면진시스템을 적용한 수직증축 리모델링 공동주택의 최적 면진주기 산정)

  • Hur, Moo-Won;Lee, Yong-Hun;Lee, Sang-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.65-74
    • /
    • 2019
  • This study presents the optimal isolation period according to the number of vertically expended stories in order to provide the basic data for the application of the seismic isolation system in the vertically expended remodeling of the aged apartment. As a result of the structural analysis, the isolation period should be at least twice the primary structure in three-story vertical expansion, three times in two-story expansion, and four times in one-story expansion for the effective application of the isolation system. On the basis of the result, the efficacy of an isolation system for the actual apartment structure, which is three-story vertically expended, was analytically verified. The maximal acceleration response on the top floor reduced by 70% and 65% of the non-isolated structure in the X and Y directions respectively. Additionally, the base shear force decreased by 30% in the both directions, compared to the non-isolated structure.

A study on Underground and Above-ground Extensions of Buildings using Jack-piles (잭파일을 활용한 건축물의 지하 및 지상증축에 관한 연구)

  • Kang, Seong-Jin;Byun, hang Yong;Hwang, Tae-il;Sho, Kwang-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.23-24
    • /
    • 2022
  • There are many demands for vertical extension construction method in domestic large cities. In this paper, we analyzed and presented the results of examining the cases of ground floor extension and basement extension using the jack pile method. Since the Jack Pile method presses in all the piles without excavating the ground, the bearing capacity of the all the piles can be checked. It was investigated as a safe construction method unlike other small-diameter pile construction methods during underground extension.

  • PDF

A Study on the Optimization of Field Sampling Number of the Durability Evaluation Method for the Extension Remodeling of the Apartment Housing (공동주택의 증축형 리모델링 안전진단 내구성 평가의 표본 수 최적화 방안 연구)

  • Shin, Heechul;Choi, Kibong;Yoon, Sangchun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.60-68
    • /
    • 2018
  • The Housing Act amended allows vertical extension up to three floors and increases the units of housing (or total floor area) to site up to 15%. Currently, the feasibility of performing vertical extension is evaluated based on safety diagnosis provisions and manuals with preliminary investigations on slope, uneven settlement, load-bearing capacity, and durability. However, a need for more reasonable evaluation methodology for the preliminary investigation is still required because the current procedures are borrowed from safety diagnosis provisions and manuals for reconstruction without detailed examinations on evaluation criteria and sampling methods. Accordingly, this study is intended to suggest a method to obtain feasible sampling size for durability assessment by statistically analyzing the safety evaluation data sets on concrete carbonation and steel corrosion obtained from apartment complexes. The results of this study are expected to be beneficial for establishing more reasonable field sampling size, and in turn, more reliable durability assessment protocol for vertical extension.

The Seepage Behaviour and Stability of Extension Embankment by Unsteady State Seepage (비정상침투에 의한 증축제체의 침투거동과 안정성)

  • Shin, Bang-Woong;Bae, Woo-Seok;Lee, Jong-Kyu;Kang, Jong-Beom
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • In this study, the seepage behavior and the stability of the extension embankment were estimated for three cases the permeability coefficient of an extension part and the rising velocity due to the rainfall of flood period. In parallel flow condition, the unstability of the slope due to embankment erosion was examined by analyzing the variation of seepage line by the seepage modeling tests and FEM analysis, and the stability of the embankment slope accompanied by the sudden rise of the water level after the flood. The seepage behavior of extension embankment indicates that the larger permeability of the extension part the longer initial seepage distance, and the exit point from embankment slope is gradually increased, and then shows unstable seepage behavior that occurs a partial collapse as safety factor decreases with time. It is because of the increment of exit points due to variation of seepage line and rising velocities of water level. Also, the collapse aspect of embankment slope shows that the increment rising velocities of water level causes the increment collapse height and depth.

  • PDF

Study on the Effectiveness of Preloading Method on Reinforcement of the Pile Foundation by 3D FEM Analysis (3차원 수치해석을 이용한 공동주택 수직증축용 기초 보강 선재하공법 효과 분석)

  • Wang, Cheng-Can;Han, Jin-Tae;Jang, Young-Eun;Ha, Ik-Soo;Kim, Seok-Jung
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.1
    • /
    • pp.47-57
    • /
    • 2018
  • In recent years, vertical extension remodeling of apartment building is considered as one of the efficient ways to broaden and enhance the utilization of existing buildings due to the rapid development of population and decrement of land resources. The reinforcement of foundation is of great importance to bearing the additional load caused by the added floors. However, because of the additional load, the carried load by the existing piles would be in excess of its allowable bearing capacity. In this study, a conceptual construction method called preloading method was presented. The preloading method applies force onto the reinforcing pile before vertical extension construction. The purpose of preloading is to transfer partial load applied on the existing piles to reinforcing piles in order to keep each pile not exceeding the allowable capacity and to mobilize resistance of reinforcing pile by developing relative settlement. The feasibility and effect of preloading method was investigated by using finite numerical method. Two simulation models, foundation reinforcement with preloading and without preloading, were developed through PLAXIS 3D program. Numerical results showed that the presented preloading method is capable of sharing partial carried load of existing pile and develops the mobilization of reinforcing pile's frictional resistance.

Environmental Changes and Embankment Addition of Reservoir Gonggeomji, Sangju City between Late Silla- and Early Goryeo dynasty (나말여초 상주 공검지의 환경 변화와 제방 증축)

  • Hwang, Sangill;Kim, Jeong-yun;Yoon, Soon-Ock
    • Journal of The Geomorphological Association of Korea
    • /
    • v.21 no.4
    • /
    • pp.165-180
    • /
    • 2014
  • Embankment of reservoir Gonggeomji in Sangju has been continuously added since the construction. After approximately 1220 yr BP of late Unified Silla dynasty when the embankment was firstly constructed, there were piled up four times with an interval of approximately 50 years until ca. 980 yr BP of late Goryeo dynasty. The first two times were relatively piled up high, while another two times were made slightly high. After addition of embankment, water level gradually became low and the quality also bad with increase of benthic- and epipitic diatoms than planktonic ones. Shoaling of reservoir was probably resulted from severe vegetation destructions on the small river basins flowing into Gonggeomji. After approximately 980 yr BP, water level rose during approximately 50 years due to precipitation increase.

A Study on Weight for Capability Evaluation in the Safety Inspection for Vertical Extension Remodeling of the Apartment Housing (증축형 리모델링 안전진단 내하력 평가의 가중치에 대한 연구)

  • Lim, Chi-Sung;Karl, Kyoung-Wan;Oh, Dae-Jin;Lee, Seok-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.51-58
    • /
    • 2021
  • As vertical extension remodeling policy was implemented in 2014, Safety Inspection Manual was established to ensure structural safety during the vertical extension remodeling. In the manual, the story weight for capability evaluation was based on the Safety Inspection Manual for Reconstruction. Although capability evaluation in the vertical extension remodeling is more important than reconstruction, engineering basis for the story weight is insufficient. Therefore it is necessary to improve the method of calculating the story weight. In this study, story importance and story weight were defined through the case analysis of capability evaluation in order to provide engineering basis for story weight. Also, new story weight equation was presented considering the load-bearing ratio of structural members.

A Study on the Durability Evaluation Criteria for the Vertical Extension Remodeling of Apartment (수직 중축형 리모델링 안전진단 내구성 평가기준 합리화에 관한 연구)

  • Yoon, Sang-Chun;Shin, Dong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.197-205
    • /
    • 2020
  • In 2014, The Housing Act amended to allows vertical extension and increases the units of housing (or total floor area) to site. Currently, the feasibility of performing vertical extension is evaluated based on safety diagnosis provisions and manuals with 1st investigation stage on slope, uneven settlement, load-bearing capacity, and durability. However, a need for more reasonable evaluation criteria for the investigation is still required because there had not been any other case study on the diagnosis for the vertical extension, and the engineering basis on evaluation criteria were not suggested. Accordingly, this study is intended to suggest feasible evaluation criteria on the carbonation, chloride ion contents, corrosion of reinforcements, crack and surface deterioration of concrete for durability assessment by codes and standards of domestic and foreign countries. The results of this study are expected to be beneficial for establishing more reasonable durability evaluation criteria, and in turn, more reliable assessment protocol for vertical extension.

소통+섬기는 마음 - 우리 사업장 탐방 - 새롭게 증축된 한국건강관리협회 서울서부지부 개인맞춤형 검진시스템과 함께 고객 앞으로!

  • Kim, Eun-Seop
    • 건강소식
    • /
    • v.35 no.1
    • /
    • pp.40-41
    • /
    • 2011
  • 한국건강관리협회 서울서부지부가 지난해 11월, 장장 6개월 동안의 증축공사기간을 거쳐 한층 달라진 위용을 일반에 공개했다. 가장 큰 특징은 내부구조변경을 통한 건강검진시스템의 개선과 고객의 입장을 배려한 동선배치로 고객만족을 실현한 것이다.

  • PDF