• Title/Summary/Keyword: 증발 현상

Search Result 351, Processing Time 0.028 seconds

Basic Study of Evaporative Characteristics of Emulsified Fuels (에멀젼연료 증발특성에 관한 기초 연구)

  • Yeom, Jeong Kuk;Yoon, Jeong Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.917-922
    • /
    • 2015
  • The goal of this study is to consider the application of alternative blended fuel to diesel engine. In this study, as the test fuels, we use a blended fuel mix of diesel and hydrogen peroxide. As the primary variable, we vary the mixing ratio of diesel and hydrogen peroxide in the experimental and numerical analysis. We perform an evaporative behavior characteristics analysis of the emulsified fuel using the Schlieren method. The numerical analysis was carried out based on results obtained from the experimental analysis using the commercial code(ANSYS CFX). Consequently, we found that the micro-explosion depends on the fraction of hydrogen peroxide, and we propose a numerical method for the quantitative evaporation analysis of emulsified fuel droplets using the calculation of the volume fraction in the oil domain.

Analysis on the Change in the Pan Evaporation Rate in the Coastal Zone (우리나라 연안의 팬증발량 변화 양상 분석)

  • Lee, Khil-Ha;Oh, Nam-Sun;Jeong, Shin-Taek
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.3
    • /
    • pp.244-252
    • /
    • 2007
  • A long-term change in the evaporation rate have an influence on the hydrologic processes at the interface between the land surface-air and crop yield. Several previous studies have reported declines in pan evaporation rate, while actual evaporation rate is expected to increase due to anthropogenic global change in the future. The decreasing trend of pan evaporation rate might be involved with global warming and accordingly the trend of annual pan evaporation rate also needs to be checked here in Korea. In this study, 14 points of pan evaporation observation are intensively studied to investigate the trend of pan evaporation for the time period of 1970-2000. Annual pan evaporation is decreasing at the rate of 1.6mm/yr, which corresponds to approximately 50mm for 30 years. Annual pan evaporation rate is larger by $\sim10%$ at the coastal area and decreasing rate is faster as -2.46 mm/yr per year, while that is -0.82 mm/yr per year at the in-land area. The results of the Mann-Kendall trend test shows 4 points are decreasing and 10 points are unchanged with 95% confidence interval. But national annual average values show the decreasing trend of pan evaporation rate as a whole, which corresponds to general trend all over the world. This study will contribute to a variety of studies on water resources, hydrology, agricultural engineering, meteorology, and coastal engineering in association with future global climate change.

Study on the Gelling Formation and Anti-gelling Properties of Liquid Detergent Based on Sodium Lauryl Ethoxy Sulfate (SLES) (소듐 라우릴 에톡시 설페이트(SLES) 베이스 액체세정제의 겔링성 및 겔링방지 특성에 대한 연구)

  • Chi, Gyeong-Yup
    • Applied Chemistry for Engineering
    • /
    • v.29 no.5
    • /
    • pp.620-625
    • /
    • 2018
  • Liquid detergent based on sodium lauryl ethoxy sulfate (SLES) as main ingredient sometimes met gelling film on the surface when it is opened in the air. It was assumed because of the change of phase diagram of micelle by concentration change of surfactant, major ingredient of detergent when the water of detergent is evaporated. SLES showed strong hexagonal liquid crystal (LC) in 30~60 wt%, and lamellar LC over 60 wt%. In this research surface gelling formation of liquid detergent which is based on SLES as main ingredient was because of water evaporation. As water of detergent was evaporated, concentration of surfactant became higher. It was checked that surface gelling was LC of mixed surfactant system. Conclusionally we applied alpha olefin sulfonate (AOS) having good solubility, Sodium secondary alkane sulfonate (SAS) preventing hexagonal LC and hydrotrope sodium xylene sulfonate (SXS) and PEG1500 in order to prevent gelling film in SLES based liquid detergent. Like this, improved formula 4 and 5 can prevent the formation of gelling film on the surface of liquid detergent when it is opened in the air.

Evaluation of ECMWF subseasonal-to-seasonal (S2S) hydrometeorological forecast across Australia (호주에서의 ECMWF 계절내-계절 수문기상 예측치 평가)

  • Jongmin Park
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.268-268
    • /
    • 2023
  • 전 지구적 급격한 기후변화로 인해 수문기상인자들의 비선형적 변동성이 발생함과 동시에 가뭄, 홍수와 같은 수재해의 발생빈도 및 강도가 증가하고 있는 추세이다. 이에 따라, 세계의 유수기관 (NASA, ESA 등)에서는 대기모형과 해양 모형의 결합 및 수치해석적 접근법을 활용하여 계절내-계절 (Subseasonal to seasonal; S2S) 예측치를 생산하여 제공하고 있다. 이에 따라, 본 연구에서는 European Centre for Medium-Range Weather Forecast (ECMWF)에서 산정되는 수문기상인자 (강수량, 증발산량 및 유출량)에 대한 정확도를 평가하고자 한다. 연구지역으로는 다양한 기후대 및 토지 피복으로 구성되어 있으며, El-Nino-Southern Oscillation (ENSO), Indian Ocean Diapole (IOD)와 같은 기후 현상이 빈번히 발생하는 호주지역을 대상으로 연구를 수행하였다. ECMWF S2S 자료에 대한 통계적 검증은 1) 지점 기반 관측치와 더불어 2) 물수지 모델 기반 수문 추정치 (The Australian Water Resources Assessment Landscape Model; AWRA-L)와 비교하였다. 연구 결과 S2S 강우 및 증발산량 산정치의 경우 비교적 짧은 예측기간(약 2주)에서 상대적으로 높은 상관관계 (R=0.5~0.6)와 낮은 편차 (강수량 = 0.10 mm/day, 증발산량 = 0.21 mm/day)를 나타내었다. 유출량의 경우, 강우 및 증발산량에 비해 상대적으로 낮은 정확도를 나타내었으며, 예측 기간이 길어짐에 따라 불확실성이 상당히 높아지는 것으로 확인되었다. 이는, S2S 계산과정에서 강우 및 증발산량 뿐만아니라 지표 유출로 도달하기 전까지의 수문기상인자들의 불확실성이 모두 모여 유출량의 불확실성이 높아진 것으로 확인할 수 있었다. 계절적 검증에서는, 강우 및 증발산량 모두 여름철에 높은 상관관계를 나타내었지만 불확실성은 상대적으로 큰 값을 나타내었다. 자세한 분석을 위해, 공간적인 불확실성을 분석해본 결과 ECMWF S2S가 매우 습윤하거나 건조한 지역에서 수문기상인자를 예측하는데 있어 한계성이 나타난 것을 확인하였다. 본 연구를 토대로, 추후 S2S 예측치에 대한 보정과 더불어 미래의 수재해 발생 위험도에 대한 정보를 획득하는데 적용될 수 있을 것으로 판단된다.

  • PDF

Investigation of the Cryogenic Oxidizer Tank Inner Phenomena of Pump-fed Liquid Rocket Engine Propulsion System (터보펌프식 액체추진기관에서의 극저온 산화제 탱크 내부 현상 고찰)

  • 조남경;권오성;정용갑;조인현;김영목;조기주;정영석
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.238-241
    • /
    • 2003
  • In case of liquid rocket using turbopump, the inner pressure of liquid oxygen tank is maintained low, so vaporization of LOX is generally occurred. This vaporization tendency increases as the inlet helium gas temperature is higher. For estimating the amount of helium in the rocket system, the LOX vaporization phenomena should be carefully considered. In this paper, Inner process of LOX tank is analyzed by two phase flow modeling. the vaporization rate and required Helium mass is investigated with varying inlet helium temperature and heat transfer coefficient.

  • PDF

A Study on Effects of Baffle on Impinging Water Jet with wall jet inlet flow (벽면제트류가 유입되는 충돌수분류유동에 배플이 미치는 효과에 관한 연구)

  • Choi, Jung-Sik;Oh, Woo-Jun;Cho, Dae-Hwan
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2009.06a
    • /
    • pp.87-88
    • /
    • 2009
  • In evaporating distillation plant velocity characteristic of fluid to flow in a evaporator have great influence on flash phenomenon. In This experimental study about impinging water jet region having the inflow of wall jet flow and effect of baffle height to flow velocity in after baffle region, making a application by PIV.

  • PDF

Evaporation Cooling Phenomena of Droplets Containing Fire Suppression Agents (화제 억제제가 첨가된 수용액 액적의 증발냉각 현상)

  • 유갑종;방창훈;김현우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.895-903
    • /
    • 2001
  • Evaporation cooling phenomena of droplets containing fire suppression agents on a hot metal surface were experimentally investigated. Solution of water containing potassium acetate (30-50% by weight) and sodium bromide (10-30% by weight) were used in the experiments, and surface temperatures were ranged from 70-116$^{\circ}C$. The evaporation time of the droplet on the heated surface was determined by using frame-by-frame analysis of the video records. It is found that the apparent evaporation time is shorter in turns of pure water, sodium bromide solution and potassium acetate solution. However, the time averaged heat flux is higher in turns of pure water, sodium bromide solution and potassium acetate solution. In-depth temperature variation of the hot metal does not occur significantly by the kinds of additive.

  • PDF

Estimation of evaporation from water surface in Yongdam Dam using the empirical evaporation equaion (경험적 증발량 공식을 적용한 용담댐 시험유역의 수면증발량 추정)

  • Park, Minwoo;Lee, Joo-Heon;Lim, Yong-kyu;Kwon, Hyun-Han
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.2
    • /
    • pp.139-150
    • /
    • 2024
  • This study introduced a method of estimating water surface evaporation using the physical-based Penman combination equation (PCE) and the Penman wind function (PWF). A set of regression parameters in the PCE and PWF models were optimized by using the observed evaporation data for the period 2016-2017 in the Yongdam Dam watershed, and their effectiveness was explored. The estimated evaporation over the Deokyu Mountain flux tower demonstrated that the PWF method appears to have more improved results in terms of correlation, but both methods showed overestimation. Further, the PWF method was applied to the observed hydro-meteorological data on the surface of Yongdam Lake. The PWF method outperformed the PCE in the estimation of water surface evaporation in terms of goodness-of-fit measure and visual evaluation. Future studies will focus on a regionalization process which can be effective in estimating water surface evaporation for the ungauged area by linking hydrometeorological characteristics and regression parameters.

A Numerical Study on Evaporation and Combustion of Liquid Spray (액체분무의 증발 및 연소에 관한 수치적 연구)

  • 정인철;이상용;백승욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2073-2082
    • /
    • 1991
  • The vaporization and combustion of liquid spray in a cylindrical shape combustor was studied numerically. Mixture of liquid drops and air was assumed to be ejected from the center-hole and assisting air from the concentric annulus with swirling. Eulerian-Lagrangian scheme was adopted for the two phase calculation, and the interactions between the phases were considered with the PSIC model. Also adopted were the infinite conductivity model for drop vaporization, the equation of Arrhenius and the eddy break-up model for reaction rate, and the k-epsilon model for turbulence calculations. Gas flow patterns, drop trajectories and contours of temperature and mass fractions of the gas species were predicted with swirl number, drop diameter, and equivalence ratio taken as parameters. Calculations show that the vaporization and the consequent combustion efficiency enhance with the increase of the swirl number and/or with the decrease of drop size, and the higher maximum temperature is attained with the higher equivalence ratio.

Analysis of Concepts Related to Explanations of Evaporation and Boiling in Secondary School Science Textbooks (중등 과학교과서에서 증발, 끓음의 설명에 제시된 개념간의 관련 정도 분석)

  • Paik, Seong-Hey;Jeong, Ae-Kyung;Ko, Young-Hwan
    • Journal of The Korean Association For Science Education
    • /
    • v.24 no.3
    • /
    • pp.429-441
    • /
    • 2004
  • This study was to examine the concepts using to explain evaporation and boiling in secondary school science textbooks developed in 6th and 7th science curriculum. The types of explanations were compared with maps represented the concepts relationships divided into middle and high schools, 6th and 7th curriculum, and subjects and chapters to find explanation diversity. The difference of explanations related to evaporation and boiling concepts was found in the school levels and subjects. There were few relationships between the main concepts of evaporation phenomena and those of boiling phenomena.