• Title/Summary/Keyword: 증기온도

Search Result 482, Processing Time 0.023 seconds

Tasks for Development of Autogenous Pressurization System and Construction of Test Equipment (자가증기 가압시스템 개발과제 및 모사시험설비 구성)

  • Cheulwoong Kim;Jisung Yoo;Sangyeon Ji;Jae Sung Park
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.27 no.1
    • /
    • pp.49-57
    • /
    • 2023
  • The autogenous pressurization has been widely adopted for propulsion systems of next-generation reusable rockets due to its low cost and high reliability. The autogenous pressurization has a simple structure, but an understanding of the heat and mass transfer occurring inside the tank is essential. For this reason, a simulation test of the autogenous pressurization was conceived. The experiment equipment was constructed based on overseas pressurization test facilities cases and expert advice. Unlike the actual autogenous pressurization system, the propellant tank was insulated to exclude external influences. The pressurized gas supply line and the propellant pipe were separated. Using the manufactured autogenous pressure experiment equipment, it is possible to evaluate the condensation phenomenon of pressurants in cryogenic propellants, comparison of the efficiency of pressurization using helium and evaporated gas and the pressurization capacity according to the temperature of pressurant.

Performance Analysis of CHP(Combined Heat and Power) for Various Ambient Conditions (외기조건변화에 따른 CHP 성능 해석)

  • Jeon, Yong-Han;Kim, Jong-Yoon;Kim, Nam-Jin;Lim, Kyung-Bum;Seo, Young-Ho;Kim, Ki-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3353-3359
    • /
    • 2011
  • The co-generation system consisted of gas a turbine, a steam turbine, heat recovery steam generator and a heat exchangers for district heating was investigated in the present study. A back-pressure steam turbine (non-condensing type) was used. A partial load analysis according to the outdoor temperature in winter was conducted and optimal thermal load and power conditions was examined using the commercial computing software Thermoflex. As a result, under a constant thermal load, the power outputs of gas turbine and overall system increased as an outdoor temperature decreased. On the other hand, the reduction in exhaust gas temperature led to the decrease in output of steam turbine. Considering the portion of gas turbine in overall system in terms of the power output, it can be known that the tendency in power output of overall system was similar to that of the gas turbine.

Compressive Strength Properties of Steam-cured High Volume GGBFS Cement Concrete (증기양생한 고로슬래그 다량치환 시멘트 콘크리트의 압축강도 특성)

  • Hong, Seong-Hyun;Kim, Hyung-Suk;Choi, Seul-Woo;Lee, Kwang-Myong;Choi, Se-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Recently, lots of researches on concrete with high volume mineral admixture such as ground granulated blast furnace slag (GGBFS) have been carried out to reduce $CO_2$. It is known that the precast concrete has an advantage of high strength at early age due to steam curing, even if concrete has high replacement level of mineral admixture. However it demands the investigation of compressive strength properties according to steam curing regimens. In this study, concretes with water-binder ratio of 32, 35% and water content of 135, 150, $165kg/m^3$ were produced to investigate compressive strength properties of high volume (60% by mass) GGBFS cement concrete according to steam curing regimens. Then steam curing was implemented with the maximum temperature of 50, $60^{\circ}C$ and steaming time of 5, 6, 7 hours. From the test results, it was found that steam curing was effective to raise early strength of high volume GGBFS cement concrete, but 28 day compressive strengths of steam cured specimens were lower than those of water cured specimens. Thus, a further study would be needed for the optimum steam curing regimens to satisfy target demolded strength and specified strength for the application of high volume GGBFS cement concrete to precast concrete members.

Effect of Temperature on Dissolution and Adsorption of Iron Oxide (온도 변화에 따른 철산화물의 용해 및 흡착 특성)

  • 안현경;이인형
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.3
    • /
    • pp.198-202
    • /
    • 2002
  • Ethanolamine (ETA), instead of ammonia, increases pH in the secondary system water and inhibits the corrosion of iron, which improves the integrity of the steam generator tubes. The different physicochemical properties of ETA from ammonia provide the different effect on the dissolution and adsorption of corrosion products entering the steam generator and thus on the hideout returns of ionic impurities in the steam generator sludge pile. The objective of this study was to investigate those properties with increasing temperature. ETA is more adsorbed onto the iron oxides, which increases the solubility of them and also lowers the hideout returns due to the reduced impurities adsorbed.

  • PDF

The level control of Steam Generator in Nuclear Power Plant by Neural Network-PI Controller (PI-신경망 제어기를 이용한 원자력 발전소용 증기 발생기 수위제어)

  • 김동화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.6-13
    • /
    • 1998
  • It is difficult to control for the level of the steam generator in the nuclear power plant because there is swell and shrink, and many disturbance such as, feed water rate, feedwater temperature, main steam flow rte, coolant temperature effect steam generator level. If the conventional PI controller use in this system, we cannot have a stability in the control of the lower power, the rejection function of disturbance, and the load following effectively. In this paper, e study the application of the of neural network based Kp, Ti for Pi controller to the level control of the steam generator of nuclear power plant through the simulation and experimental on the steam generator. We are satisfied with the resulting against the inturrupt of the disturbance, the change of setpoint through the simulation and the swell and shrink, the response of controller on the experimental steam generator.

  • PDF

Experimental Investigation on the Vapor Explosions with Water/R22 (Water / R22 폭발실험수행을 통한 증기폭발에 관한 연구)

  • Park, I.K.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 1994
  • Experimental studies hate been peformed to investigate vapor explosion phenomena which may threaten the containment integrity during severe accidents in nuclear power plants. In this study, experimental equipment is constructed for vapor explosion experiments, and the vapor explosion experiments were conducted using water/R22. During the experiments, water/R22 interaction phenomena were observed using the high speed camera, and the explosion pressure and released mechanical energy were measured with pressure transducer and pressure relief tube. And the effects of some important parameters-hot liquid temperature, hot liquid injection velocity, hot liquid injection velocity, hot liquid injection time, and cold liquid depth-were investigated on the vapor explosion. Also, the experiment with grid was conducted to study reactor -vessel-lower-structure effect on fuel/coolant interaction. Water/R22 explosion conversion ratios were measured between 0.5∼1.6%.

  • PDF

Thermal Stress Analysis for Life Assessment of Small Steam Turbine Rotor (소형 기력발전용 터빈로터의 수명평가를 위한 열응력 해석)

  • 이진상;백운봉;윤기봉
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.184-191
    • /
    • 2000
  • 본 연구에서는 국내 10MW급 기력발전소의 소형 터빈 로터에 대한 응력 해석을 실시하였다. 터빈 로터의 기하학적 형상, 증기의 온도 및 압력 등의 기동조건 변화, 로터 재료의 온도에 따른 물성값 등을 고려하여 대류 열 전달계수를 계산하는 사용자 부프로그램을 구성하였으며, 이를 바탕으로 열해석을 실시하여 로터의 온도 분포를 결정하였다. 이 온도분포 조건에서 시간 경과에 따른 열응력 해석을 실시하여 로터의 응력 분포를 결정하였으며 그 결과 취약부위에서의 응력변동 범위 및 가동중 정상상태 응력수준을 결정하였다. 이 취약부위의 응력값과 운전이력을 이용하여 크리프 수명과 피로수명을 계산하고 로터의 잔여수명을 결정하는 방법을 논의하였다.

  • PDF

Fourier transform infrared spectroscopy과 Quadrupole mass spectrometer을 이용한 Cyclopentadienyl Tris (dimethylamino) Zirconium의 열분해 특성 연구

  • O, Nam-Geun;An, Jong-Gi;Gang, Go-Ru;Kim, So-Yeon;Kim, Jin-Tae;Yun, Ju-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.99.1-99.1
    • /
    • 2015
  • ALD와 CVD 공정을 진행 하는데 있어서 전구체의 평가 및 실시간 분해과정을 확인 하는 것은 매우 중요하다. 본 실험에서는 고유전 산화막에 쓰이는 Cyclopentadienyl Tris (dimethylamino) Zirconium, CpZr(NMe2)3 전구체의 증기압 특성과 FTIR, QMS를 활용하여 $250^{\circ}C$ 온도구간 에서의 분해과정을 실시간으로 측정 하였다. CpZr(NMe2)3의 Atomic mass 는 288 amu이며 증기압은 $60^{\circ}C$에서 0.075 Torr로 측정되었다. 온도가 증가 함에 따라 FTIR 에서 CH3 symmetric stretch (2776 cm-1), CH3 symmetric stretch (2865 cm-1) intensity가 줄어 들게 되었으며 QMS에서도 15 amu (Methyl)의 신호가 온도가 증가함에 따라 감소함을 확인 할수 있었다. QMS에서 Cp의 이온전류가 사라진 이유는 Cp가 모체인 CpZr에서 모두 다 분리되었고 신호가 없어 졌기 때문이다. 본 연구를 통해서 FTIR 단독으로는 얻을수 없는 온도에 따른 세부적인 분해과정을 QMS로 실시간 측정 함으로서 FTIR의 분석 결과와 산호보완 할수 있게 되었다.

  • PDF

Measurement of the Ar Recovery Time of a Cryopump and Analysis on the Ar Instability (크라이오펌프 알곤 회복시간 측정과 알곤 불안정성 분석)

  • In, Sang Ryul;Lee, Dong Ju
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.225-230
    • /
    • 2013
  • Cryopump removes gas molecules by condensation and adsorption. Therefore, cryo-surface temperature and corresponding vapor pressure influence directly the pumping performance. If the surface temperature of any part is neither low nor high, there occurs the desorption of gas molecules condensed or adsorbed, and the emitted molecules can be captured again, which leads to a time-consuming and fluctuating change of the pressure. Though every gas can show such a pressure instability at a specified temperature range, the instability generated in a sputter system using Ar as a working gas and operating with a cryopump is especially undesirable. In this paper the cause of the argon instability is analyzed and corrective is provided through the measurement of the Ar recovery time.

노출평가를 위한 TLV 근거 - PHOSPHORUS(YELLOW)

  • Kim, Chi-Nyeon
    • 월간산업보건
    • /
    • s.380
    • /
    • pp.8-15
    • /
    • 2019
  • 황색인(Yellow phosphorus)에 대한 직업적 노출기준 TLV-TWA는 0.1 mg/㎥(0.02ppm)으로 권고하였다. 이 수준은 보고된 간경변증을 포함하여 호흡기 자극, 급성 중독인 전해질 불균형, 심근 붕괴 및 신장 피질 괴사의 가능성을 최소화하기 위한 것이다. 그러나 제한된 자료로 인중독성괴저(phossy jaw)와 같은 만성적 영향에 대한 보호 한계 수준을 설정하기에는 불확실하다. 입자 상태의 인(phosphorus)에 대한 노출은 예상되지만 증기압 수준을 감안할 때 증기에 대한 직업적 노출의 유해성을 내포하고 있다. 황색인은 가장 독성이 강한 무기 물질 중에 하나이다. 또한, 결정체 고체(crystalline solid)는 30℃ 이상의 온도에서 공기 중에 자발적으로 발화될 수 있으며, 독성이 높은 흄도 방출될 수 있다.

  • PDF